Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC DUE TO LOWEST BIDDER | |
| 2 | L2₹44.8 L+₹65,915.40 (1.49%)Rejected-Finance BOMDILA WEST KAMENG ARUNACHAL PRADESH PIN 790 001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L2 | Rejected-Finance REJECTED BIDDER DUE TO HIGHER BID VALUE | |
| 3 | L3₹45.3 L+₹1.1 L (2.60%)Rejected-Finance | L3 | Rejected-Finance REJECTED BIDDER DUE TO HIGHER BID VALUE | |
| 4 | L4₹45.4 L+₹1.2 L (2.76%)Rejected-Finance | L4 | Rejected-Finance REJECTED BIDDER DUE TO HIGHER BID VALUE | |
| 5 | L5₹45.9 L+₹1.8 L (4.03%)Rejected-Finance | L5 | Rejected-Finance REJECTED BIDDER DUE TO HIGHER BID VALUE |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
3 May 2021, 6:00 pmClosed
LT COL RAHUL KOUL
GE 859 EWS CARE OF 99 APO PIN 913859
SPL REPAIR TO BLDG NO B/TS/31 AND EXISTING PATHWAYS WITH CHEQUERED TILES AT 46 INF BDE CAMP, SPL REP TO BLDG NO B/TS/25 AND B/TS/26, SPL REP TO BLDG NO TG-4 (OR LIVING) AT 251 TRANSIT CAMP, DEMOLITION OF BLDG NO P/O/1 A TO B AT LOWER DAHUNG, PROVN OF
2021_MES_417502_3
8149/E8
Open Tender
Civil Works
Item Rate
180 days
BAISAKHI
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE 859 EWS
₹82,000
Yes
17 Jun 2021
12 Apr 2021
5 May 2021
12 Apr 2021
3 May 2021
19 Apr 2021
Amount
Demolition of cement concrete (un-reinforced) in ground floor and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (rienforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of brickwork built in cement mortar incl all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation and getting out in hard/dense soil complete all as specified and directed.
Add to Srl Item No 5 here in before for each additional 1.5m or part there of in depth beyond the first 1.5m upto 3m depth.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Returning filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm thick, in any type of soil complete all as specified and directed.
Removal of surplus soil of distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Hardcore of gauge exc. 63mm but n. exc. 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for plain cement concrete (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in surface channels and drains finishing the surface even and smooth w/o using extra cement including necessary form work complete all as specified and directed.
M&L for Reinforced Cement Concrete 1:2:4 (using 20 mm graded crushed stone aggregate) type B1 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. Note : Reinforcement and Formwork shall be measured and paid separately.
M&L for Reinforced Cement Concrete 1:2:4 (using 20 mm graded crushed stone aggregate) type B1 as in columns, pillars, piers, posts and struts complete all as specified and directed. Note : Reinforcement and Formwork shall be measured and paid separately.
Material and Labour for Reinforced Cement Concrete 1:2:4 (using 20 mm graded crushed stone aggregate) type B1, as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. Note : Reinforcement and Formwork shall be measured and paid separately
Material and Labour for Reinforced Cement Concrete 1:2:4 (using 20 mm graded crushed stone aggregate) type B1, slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. Note : Reinforcement and Formwork shall be measured and paid separately
S & F mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
All as per Srl Item No. 17 above but 6 to 8 mm TMT bars complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) as in plinth walls, cills, steps, parapet, etc including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (20 mm graded stone aggregate) precast cement concrete block masonary with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete including necessary formwork all as specified and directed.
Material and labour for providing pre-cast RCC (1:2:4) type 'B-1' using (20 mm graded crush stone aggregate) as in cover slabs of manholes and similar location including necessary form work and set in cement mortar (1:4) complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges, coping etc including necessary formwork complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat rough finished surfaces.
Formwork to sides of pillars, posts, struts, piers, columns and stanctions for rough finished flat surfaces of concrete complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (20 mm graded aggregate) precast cement concrete block masonary with solid blocks 10 cm thick and setting in CM 1:6 etc complete all as specified and directed.
M&L for Damp proof course to horizontal or vertical surfaces including necessary formwork in CM 1:2, 20 mm thick complete all as specified and directed.
M&L for applying two coats of colour wash of approved colour over a coat of whitewash including preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of cement base paint over a coat of chalk whiting primer including preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in levelling course of tiles complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in subbase for floorings complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring including finishing the surface even and smooth using extra cement complete all as specified and directed.
M & L for 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces finishing the surfaces even and smooth without using extra cement.
M & L for 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces finishing the surfaces even and smooth without using extra cement.
M & L for 20mm thick rendering in cement mortar 1:4 on brick or concrete surfaces with WPC @ 3% by weight of cement on internal wall surfaces, finishing the surfaces even & fair. Note : (WPC will be measured and paid separately)
M&L for rendering 15mm thick in CM 1:4 on concrete surfaces using WPC @ 3% by weight of cement finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI marked on packet.
M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in subbase complete all as specified and directed.
Extra for forming fair finished drain for channel 30 cm inner girth in cement concrete using extra cement incl forms, moulds , mitred/stopped ends etc.
M&L for rendering 10 mm thick in CM 1:4 on brick or concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:4 on brick or concrete wall surfaces finished rough complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non-skid ceramic tiles 7 to 8 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. Note : Screed bed shall be measured and paid separately.
M&L for Non-skid ceramic tiles 7 to 8 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. Note : Screed bed shall be measured and paid separately.
Material and labour for glazed ceramic coloured tiles of size (300x200mm) x 6 or 7mm thick on vertical surfaces such as in skirting, dados set and jointed in neat cement slurry and pointed in coloured cement to match.
M&L for chequered cement concrete tiles (20cmx20cmx25mm) thick, set jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed.
M&L for preprinted coloured chequered cement concrete tiles (20cmx20cmx25mm) thick, set jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed.
M&L for continuous PCC block edging, with 7.5cm thick PCC block (1:3:6) type C-1 using 20 mm graded aggregates block size (300x200x75mm) laid dry on edge vertically with width equal to blocks complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection surface finished even and smooth without extra cement complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B2 using 40 mm graded stone aggregate surface finished even and smooth without extra cement complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in subbase complete all as specified and directed.
M&L for screed bed or bedding layer 20 mm thick in cement mortar 1:4 finished rough for laying floor tiles etc complete all as specified and directed.
M&L for screed bed or bedding layer 15 mm thick in cement mortar 1:4 finished rough for laying floor tiles etc complete all as specified and directed.
M&L for screed bed or bedding layer 15 mm thick in cement mortar 1:6 finished rough for laying floor tiles etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for construction of septic tank in hard/dense soil, foundation in PCC 1:2:4, stone masonary wall in CM 1:4, RCC slab cover including RCC precast manhole cover having 6mm plate embedded all around/ fibre reinforced the cover with angle iron frame vent shaft and sludge chamber etc comlete all as specified for 10 users.
M&L for construction of 1.20 m dia x 3.00 m deep sokage well , excavation in hard/ dense soil, foundation PCC 1:3:6 wells of honey combed precast PCC block wall masonary including intercepting chambers, RCC cover slab, filling with brick bats complete all as specified in drawing and as directed.
M&L for 150mm dia SGSW pipes, exc in hard/ dense soil at average depth of 1.5m inclusive of manholes, RCC precast manhole cover etc including pipes laid on PCC bed, packing undr and haunching against sides complete all as specified and directed. Note : Earthwork, PCC bed and PCC haunchings shall be measured and paid separately.
M&L for SGSW drain pipes 150 mm dia Grade 'A' laid in trenches in CM 1:1 all as specified and directed.
S&F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes single socketed 75mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed.
Material and labour for providing plain cement concerete (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 110 mm on after they are laid and tested complete all as specified and directed.
Material and labour for providing plain cement concerete (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 150 mm on after they are laid and tested complete all as specified and directed.
S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches.
S&F 20mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches.
S&F 25mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches.
S&F Gun metal gate or globe valve for 20mm bore pipe with iron wheel head screwed both ends complete all as specified and directed.
S&F Gun metal gate or globe valve for 15mm bore pipe with iron wheel head screwed both ends complete all as specified and directed.
S&F vitreous china wash down water closet pan of padestal pattern, white, with P or S trap including connecting to trap and to flushing pipe etc and (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F vitreous china wash hand basin white flat back of size 550mmx400 mm including pipe chain and plug, CI brackets excluding PVC waste pipe complete all as specified and directed.
S&F fancy type, cast copper alloy, with capstan heads, chromium plated pillar tap for WHB screwed down for iron pipes of 15mm bore complete all as specified and directed.
S&F waste coupling of PTMT for 40mm bore discharge pipe (half or full threaded) . (Minimum weight 40mm-60 gms) complete all as specified and directed.
S&F PVC waste pipe 40 mm bore LDPE type, pressure rating 6 kgf/cm2 complete all as specified and directed.
S&F PVC connection pipe 450 mm long 15 mm bore complete all as specified and directed.
S&F 10 litres PVC, Syphonic action type, Flushing cistern low level, white with inlet ball valve float chain and pull and brackets complete all as specified and directed.
S&F ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia all as specified (Make : Jindal/Leader/Scico)
S&F bib tap chromium plated cast copper alloy, fancy type, 15mm dia with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed.
S&F Rotational mounded polythene water storage tank of 500 ltrs capacity, (multilayered, cylindrical, vertical with closed top) hoisted and fixed in position as specified in SSR Pt-I complete all as specified and directed.
S&F Rotational mounded polythene water storage tank of 1000 ltrs capacity, (multilayered, cylindrical, vertical with closed top) hoisted and fixed in position as specified in SSR Pt-I complete all as specified and directed.
S&F 15 mm bore angle valves fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 15 mm bore concealed type stop valves fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 15 mm bore stop valves fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 20 mm bore stop valves fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F EWC Seat Cover for Padestal pattern pan complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F waste fitting brass CP for 32 mm bore with long screwed shanks and flynuts including 32mm PVC waste pipe for WHB complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc 1.50 Sqm but not exceeding 4.00 Sqm.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm.
S&F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue , pinned at joints complete all as specified and directed.
S&F 2nd class hard wood in scantlings fixed with nails in any situation and butt joint as purlin and rafters etc. complete all as specified and directed.
S&F 50mm thick 2nd class hard wood boarding fixed with nails in any situation and butt joint, as purlin and rafters etc. complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/ spring clips all as specified and directed.
Preparing surfaces of wood or wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil etc complete all as specified and directed.
S&F 30 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc ; sizes of members of shutters as specified in SSR Part-I, section-8, clause 8.24(b) complete all as specified and directed.
Supply and fix 2nd class hard wood plain framed panelled shutters 30 mm thick (any number of panels) with panels of timber flat on both sides, feather edged or of veneered particle board medium density, wood particle board with commercial face veneer complete all as specified and directed.
S & F sheet glass 3mm thick ordinary quality and glazing with oil putty in squares n exc 0.50 Sqm in each pane.(Make: Trivani/Modi Float/Gold Fish) complete all as specified and directed.
S & F sheet glass 4mm thick ordinary quality and glazing with oil putty in squares n exc 0.50 Sqm in each pane.(Make: Trivani/Modi Float/Gold Fish) complete all as specified and directed.
Material and labour for preparation of new wood or wood based material over 10 cm in width or girth of any descriptions not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. Make:- Berger Luxol HI Gloss/Borolac (J&N) /Nerolac/Asian paints Apcolite/Superlac (Shalimar)/Dulux or equivalent.
S&F MS butt hinges, medium weight, cold rolled, 100 mm long.
S&F MS butt hinges, medium weight, cold rolled, 75 mm long.
S&F 150mm aluminium anodised barrel tower bolts of extruded section.
S&F 100mm aluminium anodised barrel tower bolts of extruded section.
S&F 150mm long aluminium anodised handles cast type.
S&F 100mm long aluminium anodised handles cast type.
S&F 75mm long aluminium anodised handles cast type.
S&F mild steel flat iron as in holdfasts complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and directed.
Dismantling plain or corrugated steel sheeting of any thickness as in roof covering complete all as specified and directed.
Supply and fix 0.63 mm thick galvanised corrugated steel sheeting with two corrugation side lap fixed with coach screws and washers with grade of zinc coating complete all as specified and directed.
S&F 0.80 mm thick plain galvanised mild steel sheeting (minimum 120 gsm), in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed) with grade of zinc coating fixed with L type or J type or cranked hooks , bolts and washer in roof complete all as specified and directed.
M&L for applying two coats of anticorrosive roof paint over one coat of red oxide primer including preparing new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc on steel surfaces of any description complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, over 10 cm width or girth not otherwise described and applying one coat of anticorrosive roof paint complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section in any position unframed work complete all as specified and directed.
Dismantling of wall or ceiling boards any thickness, including cover fillets complete all as specified and directed.
S&F 6mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to wall surface etc complete all as specified and directed.
S&F 4mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed.
M&L for 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area exc. 3 sqcm and n.exc 6 sqcm, complete all as specified and directed.
M&L for preparing new steel or iron surfaces to receive painting and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10 cm width or girth on steel surface complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. grade St.-240 complete all as specified and directed.
S&F Mild Steel work as in wind ties for roof inclduding securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc conforming to Fe-290 Gde E-165 complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturbed surface/ portion of the wall etc. complete all as specified and directed.
M&L for Point wiring with 1.50 sq mm (nominal area), PVC insulated unsheathed, FRLS grade, 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches (Make of box Prestoplast, Prestoteak), including PVC insulated unsheathed single core multi-stranded copper conductor, FRLS Grade cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one way switch complete all as specified and directed.
All as per Srl Item No 128 here-in-before but for one 5 pin socket outlet 15 Amp, 5 Amp multipurpose independent using 4.0 sqmm copper conductor cable, PVC insulated and unsheated cable and 4.0 sqmm (multi stranded) PVC insulated and unsheathed earth wire with terminal box of size 175mmx100mmx3.15mm complete all as specified and directed.
All as per Srl Item No 128 here-in-before but for one 5 pin socket outlet 15 Amp, 5 Amp multipurpose independent using 2.50 sqmm copper conductor cable, PVC insulated and unsheated cable and 2.50 sqmm (multi stranded) PVC insulated and unsheathed earth wire with terminal box of size 175mmx100mmx3.15mm complete all as specified and directed.
All as per Item No. 128 here in before but one 5 Amp socket outlet , 3 pin controlled by one switch on the independent board.
All as per Item No. 128 here in before but one 5 Amp socket outlet , 3 pin controlled by one switch on the same board.
S&F socket outlet 2 in 1, 3 pin, 5 A, flush type complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 15 A, flush type complete all as specified and directed.
Supply and fix switch piano flush type single pole one way 5 Amp 240 volts complete all as specified and directed.
Supply and fix switch piano flush type single pole one way 15 Amp 240 volts complete all as specified and directed.
S&F PVC rectangular block for mounting DBs with 3mm thick plastic laminated sheet cover of size 25cmx20cmx5cm complete all as specified and directed.
S&F PVC rectangular block for mounting switch, sockets and fan regulators with 3mm thick plastic laminated sheet cover of size 20cmx15cmx5cm complete all as specified and directed.
S&F PVC rectangular block for mounting switch and sockets with 3mm thick plastic laminated sheet cover of size 10cmx10cmx5cm complete all as specified and directed.
S&F PVC rectangular block for mounting DBs with 3mm thick plastic laminated sheet cover of size 35cmx30cmx5cm complete all as specified and directed.
Supply and fix sheet metal enclosures for DBs (Double door type) when MCBs to be used 240 volts, 4 way, with 200 A rated bus bar SPN duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
Supply and fix sheet metal enclosures for DBs (Double door type) when MCBs to be used 240 volts, 8 way, with 200 A rated bus bar SPN duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 240 volts, 'C' series, complete all as specified and directed.
S&F MCB SP, 40 Amps, 240 volts, 'C' series, complete all as specified and directed.
S&F MCB SP&N , 35 to 60 Amps, 240 volts, 'C' series, complete all as specified and directed.
S&F MCB SP&N , 63 Amps, 240 volts, 'C' series, complete all as specified and directed.
S&F ceiling rose surface bakelite 65 x 50 mm two to three terminals complete all as specified and directed.
S&F sub main wiring two runs of single core 6 sq mm stranded copper conductor of red & Black colour including 6 sq mm green colour stranded copper conductor as earth continuity conductor connected to common earth dolly including PVC casing and caping of suitable size for accomadating the wires including taking down old unsv wires complete all as specified and directed. Note : Two runs of copper conductor cable, One run of earth continuity conductor and One run of PVC casing caping shall be measured as a unit run.
S&F of 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cable flat or circular, size of cable 10 sqmm multistrandard conductor all as complete all as specified and directed by Engr in Charge.
S&F of 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cable flat or circular, size of cable 16 sqmm multistrandard conductor all as complete all as specified and directed by Engr in Charge.
S&F of 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cable flat or circular, size of cable 4 sqmm multistrandard conductor all as complete all as specified and directed by Engr in Charge.
S&F regel batten for LED Tube universal batten for G 13 T8 lamps including making electric connection from Ceiling Rose to tube light fitting complete all as directed by Engr in Charge. Cat No LHFYBYPNIA1W022 of Make Havells or equivalent model of Make Bajaj/ Phillips/C&G/ Wipro/ Eveready
S&F Photon ultra plus LED Tubelight 18W (single side connection) Ultra bright LED Polycarbonate Tubelight with 10% THD with very high efficiency suited for installation in existing T8 Tubelight with G13 lamp holders to give glare free light complete all as specified and directed by Engr in Charge. Cat No LHLDCLXNUL8X018 of Make Havells or equivalent model of Make Bajaj / Phillips/ C&G/ Eveready
S&F new generation, ultra modern energy saving surface mounted decorative hexagon LED bulk head 10 W including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable complete all as specified and directed. Make: Havells Cat Part No HEXAFT 10 W LED 857 SSYMBOPC or equivalent model of Make Bajaj / Phillips/ C&G/ Eveready
S&F LED lamp 15 watt, CDL, B-22 cap (Pin Type), 230 Volts, PF not less than 0.85 (min). Make Havells / Bajaj / Phillips/ C&G/ Eveready
S&F lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply, laying & testing of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 16 sqmm, 4 core complete all as specified and directed.
S&F in repair MCCB 63A (Current rating), four pole, AC 415 V, GS frame FP, Cat No: IHEGFP of Make Havells or equivalent model of Makes specified in PS here-in-after.
S&F accessories for MCCB enclosures, HSN Code : 8538, G frame FP, complete all as specified and diretced. Make Havells or equivalent model of Makes specified in PS here-in-after.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. Note : Only Punned down thickness shall be measured and paid.
M&L for laying precast concrete cable cover, Class LV, Type- I, flat, size 250mmx150mmx40mm including taking down old unsv one complete all as specified and directed.
S&F in repair On load changeover switch, AC 23 (side handle) in sheet enclosure conforming to IS/ IEC :60947-1 &3, 415 V, 50 Hz, HSN Code : 8536, Four pole, current rating 100 A, Cat No : IHBFFE0100 of Make Havells or equivalent model of Makes specified in PS here-in-after.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug,Cap, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) including applying two coats of black bituminous paint internally & externally upto planting depth & applying two coats of aluminium paint over a coat of aluminium primer (externally from top of coping) including writing MES pole NO with synthetic enamel paint first grade complete all as specified and directed. Note :- Earth work, PCC foundation coping shall be measured & paid seperately.
S&F security light bracket made out og galvanised street light grade pipe of 40mm dia 1.5mtr long, bend to an angle of 120 degree with 02 Nos of clamps made out of 50mmx5mm FI and 06 Nos set of nuts, bolts and wasshers painting with two coats of SEP over a coat of red oxide primer complete all as specified and directed.
S&F LED street light fitting 90 W, aerodynamically designed with better thermal management, new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP-66, road luminaire with high power LEDs as light source and electronic driver. Cat No : ENDURAPERALPLUSSL90WLED757PASYTOPCASTHO of Make Havells or equivalent model of Makes specified in PS here-in-after complete all as specified and directed.
S&F street light junction box of suitable size for three phase cable connection outdoor type, wearther proof, factory made out of PVC sheet 1.8mm thick with front side hunged opening having locking arrangement with nuts and bolts and arrangement for incoming and outgoing cable/ wire complete with the followings: (a) Bus bar with 04 aluminium strips, 100 Amps capacity insulated with insulators, including colour coding strip, including PVC cable of suitable size from bus bar to MCB. (b) MCB SPN 6 to 32 Amps--01 No (c) Clamp made out of 40mm x 5mm FI duly welded or fitted with nut and bolts complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion complete all as specified and directed.
M/S R N ENTERPRISES
M/S SUNRISE CONSTRUCTION AND CO
M/S YOGENDRA CONSTRUCTION CO
M/S MURPHEW ENTERPRISES
D.P. Traders
M/S ASHOK CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .