Loading…
Loading…
Tender Value
₹26.5 Cr
EMD Value
₹53.0 L
Closing Date
30 Jun 2026, 4:00 pmClosed
Supply, transportation, trenching, laying, backfilling, Horizontal directional drilling, HDPE pipe insertion, blowing, jointing & termination of Optical Fiber Cable for provision of 4x48(F) Optical Fibre Cable backbone in Champa-Jharsuguda section of SEC Railway.
102-SNT-PROJ-Tender-2026~SECR
102-SNT-PROJ-Tender-2026
Open
Works - General
12 Months
Jharsuguda, Odisha
₹0
₹53.0 L
30 Jun 2026
29 May 2026
8 Jun 2026
1-SOR-(Schedule-A)-Execution of Out Door Signalling work 25300695.00 Below/P
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 1 etc., including bailing out water and disposal of extra soil. All soils including soft rocky area-Depth 1.2 Mtr. & width 0.3 Mtr. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR- 2021 for S&T works- Sch 'A' item no. 1(i)(a)]
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 2 etc., including bailing out water and disposal of extra soil. All soils including soft rocky area-Depth 1.0 Mtr. & width 0.3 Mtr. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR- 2021 for S&T works- Sch 'A' item no. 1(i)(b)]
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. Hard rocky area including concreting- 3 Chase cutting and smoothening of inside surface of sizes 0.08 m deep and 0.17 m width at platform and cemented floor area. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR- 2021 for S&T works- Sch 'A' item no. 1(ii)(a)]
Laying of Signalling Cable/Power/Quad cable / PIJF cable in the excavated trench to Drg. No: CON/SK/T/5.Transportation, supply of 'U' clamps and anchoring of cable at every 10 Mtrs with 'U' clamp to Drg.No:CSTE/C/Cable/81 including back filling with excavated earth and ramming of trenches after cable laying. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR- 2021 for S&T works-Sch 'A' item no. 2(a)]
Laying of RCC pipe including supply of required quantity at site with collars (for jointing pipe) 150 mm nominal dia to Spec.No:IS-458 in excavated trench and laying of Signalling/ 5 Power cable/PIJF cable/ Quad cables/HDPE pipe through RCC pipe. Power cable shall be laid in the same trench alongwith signalling/Quad cables but in a separate pipe RCC pipe at track/pucca road/ Platform crossing/ level crossing gate etc. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned.[SOR-2021 for S&T works-Sch 'A' item no. 2(d)]
Cement Concrete of proportion 1:3:6 with graded aggregate of size 25mm. and below.[SOR-2021 for S&T works-Sch 'A' item no. 7]
Deployment of Prokline/ Hydra operation at site for exposing the burried cables or relocation the Location Box/ Signal Post with foundation as per the advice of Railway site engineer. [SOR-2021 for S&T worksSch 'A' item no. 28]
Physical tracing and opening/locating of existing working cables by precession 8 digging for diversion of cables in connection with cable clearance for engineering earth work without interfering the circuits as per the advice of Railway site engineer. [SOR-2021 for S&T works- Sch 'A' item no. 30]
Fixing of concrete cable route marker at 30-40 meter and at diversion point including 9 supply & transportation of cable route marker at site. Detail size & fixing of cable route marker should be followed as per drawing no. SDO/Cable laying/020.[SOR-2021 for S&T works-Sch 'A' item no. 32)]
Collecting, stacking with deployment of Man power, Hydra etc for Loading/ Unloading 10 and Transportation of Materials (Fresh/Released/ Unused) from (i) work site to GSD/Raipur, (ii) work site to the store of SSE(SIG)/CON,(iii) any store depot to any other store depot over Indian railways as decided by Railway Administration by suitable Trucks and stacking properly.[SOR-2021 for S&T works-Sch 'A' item no. 17]
Laying of Double Walled Corrogated Pipe length 6 meter, 120mm outer dia ,103.5mm 11 inner dia with couplers as per specification no. BSEN 50086-2-4 for under ground power/communication /signal cable protection and used for track/pucca road/ Platform crossing/ level crossing gate etc. [SOR-2021 for S&T works- Sch 'A' item no. 2(e)]
The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection,installation and wiring of steel apparatus case, fixing of terminals, fuse blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances,choke coils, Fuses, Relays, E type locks, termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case as required, testing, commissioning including subsequent alterations (if required), bunching of cables, earthing of cable, 12 armours etc.Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Aluminum paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. Steel apparatus case (Large) to Drg. No. CON/SK/T/8 with 4 Nos. of foundation bolts 20mm x 460mm to Drg. No. SA-112 A/M or latest.NOTE: - Payment can be released in a part for the above said work after completion of- (i) Foundation- 30%,(ii) Erection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% ,(iv) Commissioning - 10% of the rate.[SOR-2021 for S&T works-Sch 'A' item no. 4(a)]
Small value Engg. items, required if any, to be executed at site as per advise of DyCSTE, shall be paid as per prevailing SOR of Engg. deptt. of SECR at the time of execution.Per unit stands for lumpsum/site.[SOR-2021 for S&T works-Sch 'A' item no. 36]
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of HDPE pipe/DWC pipe(4 inch dia) Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works-Sch 'A' item no. 1(iii)(a)]
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil.Track crossing, Road Crossing by pushing 15 method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters) Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works-Sch 'A' item no. 1(iii)(b)] Above/
2-SOR-(Schedule-C)-Execution of Telecom work 21500540.00 Below/P
Location survey of cable route and preparation of tentative and final cable route plan 1 as per approved format in the section including supply of final route plan after the cables are laid and commissioned indicating clearly the exact position of the cable, joints and other critical items with reference to OHE mast & other fixed point, etc. in 12( twelve) Nos. hard bound copies on white bond paper of maximum A-3 size (well documented and bound with plastic covers).[SOR-2021 for S&T works- Sch 'C' item no. 1]
Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by 2 chiseling up to a depth of minimum 0.6 Mtr. and width 0.3 Mtr. at the bottom, supply and placing RCC hume pipe section as per drawing on sieved soil of 30mm over cable / HDPE pipe and concreting through - out the length upto a layer of 75mm. Then back filling the trench and then ramming of soil.[SOR-2021 for S&T works- Sch 'C' item no.2(b)]
Cutting the chase upto a depth of minimum 500 mm and smoothening of inside surface in concrete and beds of rocks, cable laying/ placing HDPE pipe & concreting upto the ground level. [SOR-2021 for S&T worksSch 'C' item no. 2(c)]
Transportation including loading/unloading of HDPE pipe from the stores of railway to the work site, laying of the same in excavated trench/already laid GI/RCC pipes/tubes, jointing, levelling and end sealing the pipes. [SOR-2021 for S&T works- Sch 'C' item no. 6]
Transportation, loading/unloading of OFC from the stores of railway to the work site with care,pushing/pulling OFC through the HDPE pipes, sealing of the duct by sealling /caps plugs. 5 The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually. This also includes testing of cable drums in the store premises before transportation and submissions of results thereof. Empty cable drums to be returned by the contractor. The cable drums with unused cable at site to be returned by the contractor to the stores depot of SSE/Tele-Works/BSP.[SOR-2021 for S&T works- Sch 'C' item no. 7]
Supply and placing of warning tape Orange colour of 100 mm wide printed in black 6 as "CAUTION OFC CABLE" at every 1 mtr. interval (minimum) and to be laid in the trench in station area and as directed by the representative of Railway.[SOR-2021 for S&T works- Sch 'C' item no. 9(a)]
Supply, transportation, placing and positioning breadth-wise of standard second class 7 bricks in excavated trench on the laid cable at the rate of 9 bricks per metre in the stations (Home signal to Home Signal) and colony area and at the locations as advised by site incharge of Railway. [SOR-2021 for S&T works- Sch 'C' item no.9(b)]
Transportation & Execution of following kinds of joints on Quad Cable using thermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling and ramming after jointing- straight through joint on Quad cable/10-20-50 pairs PIJF Cable [SOR-2021 for S&T works- Sch 'D' item no. 12(b)] Above/
3-SOR-Schedule-Supply of S&T Materials 1169530.00 Below/P
Supply of Universal Thermoshrink Jointing kit for derivation/transformer joint for Jelly filled Six quad cable conforming to RDSO Spec. No.: IRS-TC-77/2006 (Rev.-1) (with latest amendment). Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'D' item no. 3]
Supply of permanently lubricated HDPE pipe with outer dia 50mm, inner dia - 42mm 2 thickness -4mm with suitable couplers, plugs, end caps etc. as per technical specification No. G/CDS- 08/01 Dec. 1999 or latest TEC/RDSO specification. Supply to be made in length of 500 mtrs with + /- 10% tolerance. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works Sch 'D' item no. 6]
Steel Apparatus Case (Large) as per Drg. No. Con/SK/1/1/86, with E type lock on both side having ward No.32. Inspection by RITES. [SOR-2021 for S&T works-Sch 'B' item no. 14]
Supply of Double Walled Corrogated Pipe length 6 meter, 120mm outer dia ,103.5mm 4 inner dia with couplers as per specification no. BSEN 50086-2-4 for underground power/communication /signal cable protection. One six-meter pipe with collar at both end shall be counted a unit for the purpose of payment. Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works-Sch 'B2' item no. 26] Above/
4-Non-SOR-II (Supply of Telecom Cable) 60655956.00 Below/P
Supply of 48 Fibre armoured Optical Fiber Cable as per RDSO spec No. RDSO/SPN/TC/110/2020 rev. 0 or latest. Inspection by RDSO.
Supply of Underground Railway jelly filled 6 Quad cable with spec no. IRS:TC:30-2005 Ver 1 with amend. 1 to 5 or latest of size dia 0.9mm in drums of 1 km. Inspection by RDSO.
Supply of 24 Fibre armoured Optical Fibre Cable as per RDSO spec No . RDSO/SPN/TC/110/2020 or latest. Inspection by RDSO. Above/
5-Non-SOR-I (Supply of Telecom Materials) 75283169.40 Below/P
Supply of 40 mm diameter permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC. No. RDSO/SPN/TC/45/2013 Rev. 2.0 with latest amendment or Latest in length of 1000 mtrs/roll for each km. of HDPE duct following item are to be supplied (a) end plugs- 2 nos. (b) 1 cable sealing plugs -2 nos .(c) plastic couplers slip fit /pushfit type - 2 nos. (d) end caps to be provided along with drum- 2 nos. Colors advised for pipe is 50% bright Orange & 50% bright Green. The following materials are to be supplied with every lot of 10 km (i) Rotary duct cutter - 1no. (ii) C spanner - 1no. (iii) Chamfering tool - 1no. The duct pipes shall be in 5 different colours. Green - 22%, Blue - 22%, Orange - 22%, Grey - 22% & Yellow - 12%. Inspection by RITES.
Supply of Optical fibre Patch cords with SC-SC or suitable connectors on both ends as 2 per site requirement for interconnection between FMS to FMS or other device of length 10 Mtrs. Each as per TEC 0 240 Numbers 1232.00 At Par 295680.00 Specification No. G/OFJ-01/03 JUN 99 (With latest amendment). Max Permissible loss-0.2dB. Inspection by Representative of Railway Engineer.
Handheld OTDR of Model -930XC-20C or similar make with SC connector. Specifications as per tender document. Product supply should comprise as detailed in agreement. Representative of Railway Engineer.
Supply of Make: Fujikura Fusion Splicing Machine, Model No. 88s fully automatic (Latest). Inspection by Representative of Railway Engineer.
Optical power meter having following specification and accessories: Specification : Wave length 800- 1600nm, Range 45 to +10dBm , Auto offset nulling, Automatic wavelength 5 recognition, Tone detection- 270 Hz, 1 KHz & 2 KHz, OFC connector type-ST, Battery- 9V Rechargeable with AC adapter, Warranty-as per IRS term and condition or as per OEM whichever is more. Accessories : ST Adapter for connection of two OFC cables, Fiber optic connector cleaner box. Calibration certificate traceable to NABL or OEM standard. Test certificate, User Guide. Inspection by Representative of Railway Engineer.
Smart Class Lab items with all accessories as per Annexure-IV. Make model- 1)DLP 6 projector- BENQ or similar make model no. MX-560 P 2) 4 in 1 Speaker set make- INTEX or similar. (Warranty Period : Upto 30 months from the date of supply). Inspection by representative of Railway Engineer.
Supply Installation Testing & Commissioning of Fixed video call application with DCC crystal UHD signage Large Format Display Diagonal Size-75'' Resolution-UHD SAMSUNG QB75 or 7 similar Orientation-Land spec/Portrait Contrast Ratio-4000:1 Led Type- VA USB/HDMI/LAN-1 port or more in-built Signage software Inbuilt office 365 application Operation hr-16/9 Warranty-3yr on site with All Accessories & programming Charges for Integration with Telepresence systems. Make/Brand: - SAMSUNG QB 75 or similar (Warranty Period: Upto 36 months from the date of supply). Inspection by representative of Railway Engineer. 1820500.0
A Remote Terminal Unit for monitoring the dark fibre comprising of 2 to 8 port optical switch and capable of monitoring 2 to 8 fibers at a time respectively and covering a monitoring 8 distance of minimum 75 Km OFC network per optical Port. Equipment must be of 32 dB or more dynamic range with 2 to 8 port optical switch output. Powered from both DC 48V and AC 230V, 50Hz. RTU must be able to be fitted in existing 19" Rack. It should able to generate wavelength of 1310nm or 1550nm or 1625nm for monitoring of fibers. Insertion loss must not be more than 1.5db and MTBF must be better than 6 million cycles. It shall also be operated in temperature range of 0 deg C to 50 deg C. Inspection by RITES. 2920550.0
FMS (Fiber Monitoring Software / Application software for monitoring optical fiber network) server application with Google Conduit a) Basic Fault Management Module for detecting the fault in the optical fibre under surveillance and provide the optical distance and corresponding surface distance of the fault identified. b) Map Integration Module displaying fibre route in GIS / 9 Google map and display the visual indication of the faults on the map c) Network Analysis Module for analysis of the optical fibres under surveillance and provide trend analysis d) Report Generation Module for customizable report generation e) Modem Interface for sms based alarm escalation for escalation of alarms through sms to registered users as defined by admin f) Fibre Database Designer Module g) As Built Drawing / GIS Integrator Module h) Configuration Module i) Fault restoration Updating Module for tracking of restoration and updating of the restored fibres j) Interface with customer NOC for Trouble Ticketing k) Integration with Field Mobile Application Module
Server -RAID architecture + Database Server + Online UPS -1x Intel Xeon E5-4607 (2.2 GHz / 6 Core / 12MB / 95W) processor / 8GB memory / 5SFF Drive Cage/ No Standard HDD / HP 10 Smart Array P420 / 1GW FBWC Controller Raid / 1200W CS Platinum Hot Power Supply should support operating systems: Microsoft Windows server 2003/2008/2008 /2012 R2, - Support Ipv4 / Ipv6 - Database: MS SQL standard edition with 5 CAL - Antivirus should be installed and regular updates/ signature and support shall be provided up to warranty period - Must be supplied with online UPS + Battery for backup for 4 hours. Inspection by RITES.
Workstation Industrial grade Desktop computer for Control office - Processor Intel 11 Core,10Ghz,8GB RAM or more, 1 TB hard disk, DVD Drive - Operating System: Windows 10 or above - MS office included, licensed antivirus - Enhanced USB Keyboard, Optical Mouse - Must be supplied with colour inkjet printer - Suitable UPS for 30 minutes backup - Items shall be equivalent or superior to the specifications. Inspection by representative of Railway Engineer.
GSM Modem + SIM with 1 years- GSM modem with RS232 cable and antenna - Supports AT command - Powered by 12V adapter. Inspection by representative of railway.
Supply of channel (Injection-molded cable of size width int/ext) 240/340mm, height 13 (int/ext) 155/230mm, length 1 meter (+/- 10 mm), weight per meter 8 KG (Top and Bottom) Material Polyolefin Engineering Plastic with fire protection class K-1, following DIN-53438 part I, for laying Signalling/Telecom Cables. Kg (Top As per Technical Specification STS/Cable- Laying practices Vol. IV Dt. 09.05.2018 & DIN54348 parts -II RDSO (Inspection by RITES).
19" 42 U Rack (suitable for RTU fitting) with Accessories - Rack colour should be light gray / black / offwhite powder coated. Each equipped with AC 230V fan for ventilation. Inspection by representative of railway.
Supply of smart 55 " display as per Annexure-V. Inspection by representative of Railway Engineer. 1424280.0
Supply of GNSS based cable route tracer kit with receiver with built in mount for GNSS receiver, 12W or higher power transmitter with >= 130V Voltage boost, suitable for detecting & mapping underground cables with accuracy up to 2 5 cm, with current direction up/down arrows. 17 Supply shall include locating receiver with RTK receiver powered by locator receiver, transmitter, compatible dual Bluetooth android phone, mobile application pre-installed in android device with 5 years subscription & PC database software access for direct map generation & download including depth data, 3 years subscription for GNSS correction service & standard accessories, per specification attached. Make/Model: Rycom Pathfinder PLDL Route locator with Trimble DA2 GNSS receiver or similar [Detailed specification as per Annexure-II]. Inspection by representative of Railway Engineer.
Supply of 9U Rack with 19 inch standard dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organizer with wall fixing screws and all other complete accessories. Inspection by Rep. of Railway Engineer.
PC based Supervisory Console with all hardware and accessories. Inspection by:Representative of Railway Engineer. Note:This system should have following features: ALL IN ONE 19 DESKTOP COMPUTERS (Processor :- Intel core i5,Processor Number :- Intel core i5 10500, Windows 10 Professional, Recover:- CD from the OEM, RAM- DDR4, RAM size;- 16 GB or more, RAM Speed:- 2666, Type of Drivers:-HDD, SSD, HDD: -1000@ 7200rpm, SSD:- 512GB, Display 21.5 or more, with Webcam, speaker, wi-fi or with higher specifications and three year on site warranty. Make:ACER/DELL/HP/LENOVO.
Supply, installation, Testing and commissioning of L-2 manageable Switch (available 20 minimum port:24Nos.10/100/1000 Base-T port with 4 Nos.10/100/1000 Base-T/1000 Base-X ports). Make: Cisco, Extreme, Allied telesis, or Juniper. Inspection by Consignee. MAF have to be submitted along with tender document.
Supply of Router 4 WAN ports make: CISCO 2911 W/3 GE or ISR 4331, 04 WAN ports 21 with WAN cards (4 EHWIC slots), 2DSP, 1 SM, 256MB CF, 512MB DRAM, IPB with complete accessories for full functionality. (Make- CISCO 2911 or 4331 or similar model of Juniper network.) along with three years warranty from the date of supply. Inspection by Representative of Railway Engineer. MAF have to be submitted along with tender document.
Supply of Router 8 WAN ports make: CISCO 2911 W/3 GE or ISR 4331, 08 WAN ports 22 with WAN cards (4 EHWIC slots), 2DSP, 1 SM, 256MB CF, 512MB DRAM, IPB with complete accessories for full functionality. (Make- CISCO 2911 /4331 or similar model of Juniper network or latest.) along with three years warranty from the date of supply. Inspection by Representative of Railway Engineer. MAF have to be submitted along with tender document. Above/
6-Non-SOR-III (Execution of Telecom Materials) 81073175.00 Below/P
Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (48 fibres) and testing as per technical Specification No. GROJC- 2/02 sept 2003. Supply of splice enclosure (48 fiber) shall be as per RDSO specification No. RDSO/SPN/TC/68/2014 Amdt. 1.0 or latest. All materials including fusion splicing machine used for fiber splicing and OTDR for testing and other testing materials if any shall be arranged by the contractor.
Supply and installation of rack mounted 48F FMS fiber of Bestnet Make or similar of suitable connectors as per site requirement.
Excavation of jointing pit without damaging the fiber and provision of joint chamber of 1.2 mtr dia, 60 cm height and 50mm thickness with two piece top cover and bottom cover with 3 holes for drainage and cable entry (the reinforcement drawing will be as per technical specification). This includes back filling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by Railway Representative.
Supply Installation of OFC joint enclosure and splicing of Optic fiber cable (24 fibres) 4 and testing as per technical specification No. GR OJC- 2/02 Sept 2003. Supply of Splice Enclosure (24 fiber) shall be of TVS make or similar Part No.1500-L18X-XX as per RDSO specification No. RDSO/SPN/TC/68/2014 Amdt. 1.0 or latest. All materials including Fusion splicing machine used for splicing and OTDR for testing and other testing materials if any shall be arranged by the contractor.
Excavation of cable coil pit 1.5m length X 1.5m breadth in rear of relay room/AFTC huts.
Supply and Fixing of Perforated GI pipes of 100 mm dia for entry of cable on girder bridges, RCC bridges, drains, culverts, rocky places, tunnels/ deep cuttings or at places as advised by the engineer in charge of the work. This includes trenching up to the required depth as decided 6 by the Engineer at site and making holes of 5 mm dia(approx.) at 20 cm intervals on the GI pipe. The pipes are to be fixed on the girder bridge by suitable bridge fixtures at an interval of 1.0 mts. (min) or directives of Railway Engineer. On RCC/masonry bridges or in rocky places, if required the entire length of the pipe is to be concreted up to a height of 100mm above the pipe. GI pipe shall be TATA or Jindal make.
Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done of min. diameter 120mm & at the depth of minimum 1400 mm from the ground level. The ground level 7 shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos, of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after two nos. of DWC/HDPE(40 mm dia.)/GI pipe is laid in the bore.
Supply and installation of fully loaded rack mounted 24F FMS fiber of Bestnet Make or similar to suit connectivity for switches and FMS with 24 nos. 0dB adaptors connected with suitable pigtails.
Hiring of Skilled Labour assistance SE/JE in day to day works i.e. assisting for 9 supervising cable laying work, noting of daily work status, carrying the tools & equipments etc watch & ward during the course of execution of work as per the instructions of concerned SE/JE (c)(Chief Labour Commissioner(C) New Delhi Dated:e:25/09 / 2024)
Hiring of Unskilled Labour assistance SE/JE in day to day works i.e. giving marking of 10 cable route, cable laying, taking of measurements, noting of daily work status, carrying the tools & equipment etc., watch & ward during the course of execution of work as per the instructions of concerned SE/JE (Chief Labour Commissioner(C) New Delhi Dated:e:25/09 / 2024)
Laying of Polyolefin cable channels of all sizes by digging of the trench of the required size that top of the channel is not less than 0.3 Meter below earth/ground level and at the concrete surface to be laid with suitable fasteners with Contractor.
Installation and commissioning of 9U rack 19" size. All materials required are supplied by the contractor.
Onsite Training of "Monitoring of OFC equipment" and other subsystems at different locations. (Training Period 100 Mandays)
Installation & Commissioning (RTUs, FMS Server Application, Software loading in Server Machine, Mobile client units and EMS
Supply and Installation of 19 inch 42U 600mm Depth Telecom Rack with Standard Accessories (Closed type) Front Door Glass type, all doors should be removable type [Detailed Specification as per Annexure-I]. Inspection: Representative of Railway Engineer.
Route Survey works (Survey of Railway Fiber Route suing DGPS and Electronic Route Marker, capturing Geo and Fiber Data at every meter, manhole, splice points, LSCs and Other Termination points) for GIS mapping as per Annexure-III
Transportation, installation, testing and commissioning of Router 8 WAN ports. The 18 work to be executed as per directives of the Representative of Railway Engineer. Note: All the sundry materials required for the installation, wiring, testing and commissioning of above work will be supplied by contractor.
Transportation, installation, testing and commissioning of Router 4 WAN ports. The 19 work to be executed as per directives of the Representative of Railway Engineer. Note: All the sundry materials required for the installation, wiring, testing and commissioning of above work will be supplied by contractor.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .