| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L1 | Accepted-AOC AOC GIVEN TO M/S HUMERS INFRATECH BEING LOWEST BIDDER | |
| 2 | L2₹52.9 L+₹7.6 L (16.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹53.3 L+₹8.0 L (17.7%)Rejected-Finance PO VIKRAMKHAND ROAD LANE NO 05 HOUSE NO 16 ASSAM 788007 | CACHAR | ASSAM | 788007 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹53.5 L+₹8.3 L (18.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹61.0 L+₹15.8 L (34.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
SPECIAL REPAIRS FOR OVERHEAD TO UNDERGROUND CABLING FROM MRS TO ROP HILLS AND ALLIED WORKS AT CIJW SCHOOL VAIRENGTE UNDER GE SILCHAR
2023_MES_633277_1
8847/E8
Open Tender
Civil Works
Item Rate
180 days
VAIRENGTE
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹94,000
29 Mar 2024
18 Dec 2023
17 Jan 2024
18 Dec 2023
15 Jan 2024
2 Jan 2024
25 Dec 2023 - 29 Dec 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations or for laying of cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in foundations, for fixing poles, stay assembly, etc. with or without champered angles and flat, splayed, rounded or mitred tops, etc. complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type B-1) using 20mm graded stone aggregate as in coping, collars, etc. to poles, stay assembly, etc. with or without champered angles and flat, splayed, rounded or mitred tops, etc. including all necessary formwork surfaces finished even and fair without using extra cement complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, 100mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing off old damaged tubing complete all as specified and as directed
Taking down cross-arms, MS channel, etc. of any type / size from any location / position after taking proper shut down, etc. and disposing off complete all as specified and as directed
Taking down aluminum conductor steel reinforced (ACSR) conductors of any type / size from any location / position after taking proper shut down, etc. and disposing off complete all as specified and as directed
Taking down earth/stay wire, cradles, service wire, etc. from any location / position after taking proper shut down, etc. and disposing off complete all as specified and as directed
Taking down insulators of any type / size from any location / position after taking proper shut down, etc. and disposing off complete all as specified and as directed
M&L for trenchless boring, suitable for passing 100mm bore protection pipe under road, hard standing, pavements, etc. for crossing / routing of cables, etc. complete all as specified and as directed
S&F in repairs GI strip of size 25x4mm with saddles and fixing screws, etc. for conductors above / below ground as earth continuity conductors for earthing or connection upto test point complete all as specified and as directed
M&L for stay assembly and accessories as shown in electrical plate No. 1 of SSR Part-I, using stay rod of 20mm dia, stay plate 6mm thick of size 300x300mm including stay wire 7/3.15mm dia of suitable length including taking down and disposing off old stay assembly complete all as specified and as directed Note: Cost of PCC for fixing shall be deemed to be included in the quoted rate
Supply , installation, testing and commissioning, entirely powder coated LT feeder pillar box/panel, CPRI approved, outdoor cubical type of size specified, with powder coated copper bus bar, platform mounted, dust and vermin proof, IP65 protection class, fabricated out of 3.15mm thick CRCA MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and suitable locking arrangement, internal wiring with 2.5sqmm PVC insulated, stranded copper conductor cable, IS-694 marked and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs, TPN bus bar and extension links duly insulated with colour code heat shrinkable sleeves and shall be mounted on epoxy resin insulator to contactor not less than 10sqmm single core copper cable stranded copper conductor cable, IS-694 marked including and housing the following switchgears and components complete all as specified and as directed as detailed hereinunder:
Notes for item No. 16: (a) The Contractor shall submit drawings from the approved OEM (as approved) for approval of the GE through the Engineer-in-charge (b) The feeder panel/pillar shall include 2Nos. danger notice plates made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 250x200mm with letter, figures and conventional skull bones in signal red colour duly fixed with nuts, bolts and washers, etc. with voltage and danger indicated both in Hindi and English (c) The feeder shall include bus bar with earth bar in 40x5mm GI strip and complete wiring (d) Excavation, earthwork in any type of soil, construction of PCC foundation for panel, grouting, etc. shall be deemed included in quoted rate. Foundation specifics shall be as per OEM of panel and height shall be kept above mean flood level. The Contractor shall submit foundation design drawings to attain approal of he GE (e) Foundation bed shall be in PCC 1:3:6 type C2 using 40mm graded stone aggregates with a depth of 15cm below ground level and 1.5m above ground level with stare and slot openings for I/C and O/G cables
item No. 16 contd. Panel (1000x800x500mm) with copper bus bar 600A (40x10mm) and with the following: Incoming (a) MCCB 4 pole, 415V AC grade, 250A, 36kA Ics = 100%Icu- 01No. (b) LED lamps for phases indication R-Y-B with toggle switch (set of 3)-01 set Outgoing Through bus bar
Supply , installation, testing and commissioning, entirely powder coated LT feeder pillar box/panel, CPRI approved, outdoor cubical type of size specifed, with powder coated aluminium bus bar, platform mounted, dust and vermin proof, IP65 protection class, fabricated out of 3.15mm thick CRCA MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and suitable locking arrangement, internal wiring with 2.5sqmm PVC insulated, stranded copper conductor cable, IS-694 marked and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs, TPN bus bar and extension links duly insulated with colour code heat shrinkable sleeves and shall be mounted on epoxy resin insulator to contactor not less than 10sqmm single core copper cable stranded copper conductor cable, IS-694 marked including and housing the following switchgears and components complete all as specified and as directed as detailed hereinunder:
Notes for item No. 21: (a) The Contractor shall submit drawings from the approved OEM (as approved) for approval of the GE through the Engineer-in-charge (b) The feeder panel/pillar shall include 2Nos. danger notice plates made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 250x200mm with letter, figures and conventional skull bones in signal red colour duly fixed with nuts, bolts and washers, etc. with voltage and danger indicated both in Hindi and English (c) The feeder shall include bus bar with earth bar in 40x5mm GI strip and complete wiring (d) Excavation, earthwork in any type of soil, construction of PCC foundation for panel, grouting, etc. shall be deemed included in quoted rate. Foundation specifics shall be as per OEM of panel and height shall be kept above mean flood level. The Contractor shall submit foundation desgn drawings to attain approal of he GE (e) Foundation bed shall be in PCC 1:3:6 type C2 using 40mm graded stone aggregates with a depth of 15cm below ground level and 1.5m above ground level with stare and slot openings for I/C and O/G cables
item No. 21 contd. Panel (1000x800x500mm) with aluminium bus bar 400A (40x10mm) and with the following: Incoming (a) MCCB 4 pole, 415V AC grade, 250A, 36kA Ics = 100%Icu- 01No. (b) LED lamps for phases indication R-Y-B with toggle switch (set of 3)-01 set Outgoing Through bus bar
S&F LED street light fitting 1x72W 230V AC, pressure die cast aluminium housing, having heat resistant toughened glass, IP-66 protection class, with all accessories pre-wired including 72W lamp, and all necessary fixing arrangements to existing pole, etc. and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
M&L for design, supply, connecting, testing and commissioning of Aerial Bunched Cable (ABC) [3 core 120sqmm + 1 core 95sqmm], ISI marked 1100V having XLPE insulated cable (three power core) with stranded compact circular aluminium conductors twisted over an insulated aluminium alloy messenger wire for use as overhead distribution feeders, with / without one street lighting core with stranded compacted circular aluminium conductor XLPE insulated suitable for use on 3-Phase AC system conforming to IS-14255/1985 (amended upto date) complete all as specified and as directed Notes: (a) Design drawing shall be made by Contractor and shall be submitted for approval of the GE (b) Rate quoted shall be inclusive of all accessories viz. MS flats, insulators, earth wires, suspension clamps, steel strap, pole brackets, connectors, caps, etc. as required complete (c) Tests shall be done as stipulated and reports are to be submitted alongwith claim of payments
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V grade, PVC bedded, galvanized steel strip or wire armoured electric power cable, heavy duty stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, covers, tubing, cushioning will be measured and paid separately under respective items herein
2 core 10sqmm
4 core 16sqmm
3.5 core 25sqmm
3.5 core 35sqmm
3.5 core 50sqmm
3.5 core 70sqmm
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V grade, PVC bedded, galvanized steel strip or wire armoured electric power cable, heavy duty stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, covers, tubing, cushioning will be measured and paid separately under respective items herein
3.5 core 120sqmm
3.5 core 240sqmm
3.5 core 300sqmm
M&L for cable jointing kit for 1100V grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core 16 to 50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1100V grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core 70 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1100V grade cable for end terminal heat shrink type joint with jointing material and accessories suitable for 3.5 core 240 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, pole caps, bolts, nuts and screws type 410 SP-31, 9m long, conforming to IS: 2713, with detachable bracket arms including painting with two coats of bituminous paint upto 1.5m from ground and two coats of aluminium paint over a shop coat of primer to remaining portions at any locations complete all as specified and as directed Note: Excavation / earthwork and PCC coping etc. will be measured and paid separately under respective items herein
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, pole caps, bolts, nuts and screws type 410 SP-55, 11m long, conforming to IS: 2713, with detachable bracket arms including painting with two coats of bituminous paint upto 1.5m from ground and two coats of aluminium paint over a shop coat of primer to remaining portions at any locations complete all as specified and as directed Note: Excavation / earthwork and PCC coping etc. will be measured and paid separately under respective items herein
&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 25x4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item Nos. 43: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
M/S TAPAN KUMAR RAY
M/S SUBHAM ENTERPRISE
NAGALAND AGENCIES CO
SURANA CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .