Loading
Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAdmitted-Finance | ₹10.0 L | L1 | Admitted-Finance |
| 2 | L2₹10.0 LAdmitted-Finance | ₹10.0 L | L2 | Admitted-Finance |
| 3 | L3₹10.0 LAdmitted-Finance | ₹10.0 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 UDYAM UP 29 0007957 | GONDA | UTTAR PRADESH | 271001 | - | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | SAFELINE ELECTRICALS L2 | P. K. POWER SOLUTIONS L3 | PRITHVI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Testing of 33/11 KV incoming & outgoing feeder panels isntalled at different 33/11 KV sub-Stations under EDD-Mankapur, Gonda including testing of CTR both by primary injection. Works includes cleaning and adjustments of relay contacts and springs, checking of closing and tripping of breakers on remote/local and protection trip command through CT (by means of primary Injection). | 150 | Nos | 2,575 ₹3.9 L | 2,580 ₹3.9 L | 2,570 ₹3.9 L |
| 2.00 | Testing of 5/10 MVA Power Transformers installed at various sub-station under EDD-Mankapur, Gonda, including following test:-
(a) Open Circuit test.
(b) Short Circuit Test.
(c) Magnetization Balance test.
(d) Magnetic Balance test.
(e) Insulation test by megger.
(f) Buchholz, OTI/WTI Circuit test. | 30 | Nos | 16,500 ₹5.0 L | 16,490 ₹4.9 L | 16,480 ₹4.9 L |
| 3.00 | Providing 3 Phase DG set on vehicle for availability of 3 phase supply for testing of 33/11 KV sub-stations. Vehicle with DG set & Operator will be made available for 12 hrs in each job by the contractor. | 11 | Nos | 10,510 ₹1.2 L | 10,515 ₹1.2 L | 10,500 ₹1.2 L |
Tender Value
₹10.0 L
EMD Value
₹9,960
Closing Date
1 Apr 2026, 5:00 pmClosed
SE EDC GONDA
EDC GONDA
62/EDC(G)/2025-26
2026_MVVNL_1130489_8
NVS-55-62/EDC(G)/2025-26
Open Tender
Electrical Works
365 days
EDC GONDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
SE EDC GONDA
₹9,960
Yes
EDC GONDA
17 Apr 2026
26 Mar 2026
2 Apr 2026
26 Mar 2026
1 Apr 2026
26 Mar 2026
30 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Testing of 33/11 KV incoming & outgoing feeder panels isntalled at different 33/11 KV sub-Stations under EDD-Mankapur, Gonda including testing of CTR both by primary injection. Works includes cleaning and adjustments of relay contacts and springs, checking of closing and tripping of breakers on remote/local and protection trip command through CT (by means of primary Injection). | |||||
| 2Testing of 5/10 MVA Power Transformers installed at various sub-station under EDD-Mankapur, Gonda, including following test:- (a) Open Circuit test. (b) Short Circuit Test. (c) Magnetization Balance test. (d) Magnetic Balance test. (e) Insulation test by megger. (f) Buchholz, OTI/WTI Circuit test. | |||||
| 3Providing 3 Phase DG set on vehicle for availability of 3 phase supply for testing of 33/11 KV sub-stations. Vehicle with DG set & Operator will be made available for 12 hrs in each job by the contractor. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
BOQ_2108928.xls
BOQ • 0.25 MB
62.pdf
Tender Documents • 0.59 MB
Download all tender documents and submit your bid