PROJECT MANAGER ( ELECTRICAL )
ELECTRICAL UNIT-1, RNN LTD, ASHOK MARK, LUCKNOW
SITC OF FIRE FIGHTING INERT GAS EXTINGUISHING SYSTEM AND FIRE ALARM SYSTEM AT DISTRICT COURT HARDOI
2020_UPRNN_508196_2
386/PM(E)/EU-1/ETENDER/RNN/20 DT. 31-08-2020
Open Tender
Electrical Works
Item Rate
90 days
HARDOI
AS PER TENDER
2 documents required · 2 mandatory
₹11,800
UPRNN LTD
₹3.7 L
28 Dec 2020
10 Oct 2020
24 Oct 2020
10 Oct 2020
24 Oct 2020
10 Oct 2020
Amount
FIRE FIGHTING INERT GAS EXTINGUISHING SYSTEM
SITC of MS Seamless Cylinder made by hot spinning process, CCOE/TPED Approved, confirming to IS: 7285 (Part 2) 2004.
SITC of 80 Liter capacity (Cylinder neck size - 25E – DIN EN ISO 11363-1), 300 bar working pressure along with CF-IG-541 Gas min. 22.90cum. Cylinder valve Cylinder valve assembly DN12, working pressure upto 300 Bar at 15 Deg.C, suitable for manual, pneumatic, pneumatic-manual and electrical activation, TPED (Directive 2010/35) CPR (Regulation 305/2011/EU) LPCB (DIN EN 12094-4) Test pressure - 450 Bar Valve outlet thread-M24 x 1.5
SITC of 24 VDC Electric Control Head operated from the Detection & Control System or locally with a manual lever on the control head.
SITC of Lever operated Reset Tool for Solenoid actuator
SITC of Pressure gauge with switch contact for 300bar, Pressure Range to 400bar, Switching Point 270bar
SITC of BRASS PNEUMATIC ACTUATOR, minimal pilot pressure- 8 bar suitable for 300 Bar system)
SITC of Manual Actuator with lever thread size M36x1.5
SITC of BRASS PNEUMATIC-MANUAL RELEASE DEVICE WITHOUT SCREW PLUG, minimal pilot pressure- 8 bar suitable for 300 Bar system)
SITC of Pilot hose, 4mm wide, working pressure 360 bar Flexible pilot/actuation hose is used in multiple cylinder systems. Pilot pressure is directed to a pressure operated control head on each cylinder valve using pilot/actuation hose. 600mm long
SITC of Pilot hose, 4mm wide, working pressure 360 bar Flexible pilot/actuation hose is used in multiple cylinder systems. Pilot pressure is directed to a pressure operated control head on each cylinder valve using pilot/actuation hose. 1000mm long
SITC of Adaptor for pilot line / Pilot Hose Adaptor
SITC of Non-Return Valve for pilot line
SITC of Bleed Valve Bleed valve for use in pilot lines of fixed fire extinguishing systems. The Bleed Valve avoids an incorrect pressurization owing to possible leakage from the cylinder Valve.
SITC of Screw Plug
SITC of Discharge Hose, Nominal Wide-16mm, burst Pressure 1080 Bar. Agent is routed from the cylinders to the discharge piping by a flexible discharge hose. The hose is connected to the discharge outlet of the Cylinder valve and terminates at the system piping or check valve of the discharge manifold. Thread Size- M24 x 1.5
SITC of Check Valves for discharge hose pipe Steel Check Valves are installed at the inlet of discharge manifold in a multiple cylinder arrangement to allow removal of any agent cylinder from the manifold while still retaining a closed system.
SITC of Discharge Nozzles are designed to provide the proper flow rate and distribution of Gas to total flood a hazard area : 180 deg. / 360 deg.
360 DEG, 25 NB
360 DEG, 40 NB
10 way - 2"BW x sch 160, ASTM A-106 Gr.B
ACTUATION SYSTEM
SITC of 2kg M.S. Seamless Cylinder filled with CO2 gas along with wall/structure mountings.
SITC of Cylinder valve for CO2 (DN12) actuation cylinder
SITC of Manual Activation including mechanical box(1no.), SS wire-12mtr, Aluminium sleeve-12mtr, corner pulley 6nos. And end of line 2nos.
PIPING & FITTINGS
SITC of MS Seamless pipe schedule 80 of pipe sizes 15NB to 100NB with fittings, nut bolts , U clamps etc…
Mild steel Supporting structure for Cylinder Bank, piping from cylinder location to protected area
CONVENTIONAL FIRE EXTINGUISHING PANEL (GAS RELEASE PANEL) & SWITCHES
SITC of 3 Zone Automatic Gas Extinguishing Panel, supports 3 conventional detection zones and 1 flooding zone, LCD display (128 x 64 resolution), providing clear status indication and programming routines, countdown timer displayed with large font on LCD display, on-board 4 programmable inputs, 1 manual trigger, and 6 release related inputs; fire, fault, and 2 programmable output relays. battery capacity 24V DC 7 Ah, 1000 event logs, EN 54-2, EN54-4, & EN 54-13, EN12094-1
SITC of Conventional Optical Smoke Detector with double dust trap chamber, internal algorithm processing for optimised performance, central LED for 360o view of detector status, Approved by LPCB for EN 54-7.
SITC of Conventional Class A1R Heat Detector, heat alarm threshold temperature 58oC, internal algorithm processing for optimised performance, central LED for 360o view of detector status, Approved by LPCB for EN 54-5.
SITC of Standard Base for Pro-Sense Conventional Detectors.
SITC of Manual Abort Switch compatible with 3 Zone Automatic Gas Extinguishing Panel provided above..
SITC of Manual Release Switch compatible with 3 Zone Automatic Gas Extinguishing Panel provided above.
SITC of Conventional Manual Call Point, with resettable type glass element, clearly visible alarm flag in activated state, provided with custom reset key, Approved by LPCB for EN 54-11.
SITC of LED Signage for providing visual notification in case of imminent agent release upon the activation of count down timer. The signage should display the following "AGENT GAS TO BE RELEASED PLEASE EVACUATE" / "AGENT GAS TO BE RELEASED DO NOT ENTER". Dimension of the signage 750mm(width) x 250mm(height).
SITC of 2C x 1.5 Sq.mm PVC insulated copper conductor armoured cable.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .