| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC L1 Bidder and the offer is acceptable as per terms and conditions of e-NIT | |
| 2 | Rejected-Technical AT P O BACHRA P S PIPARWAR PIN 829201 | CHATRA | JHARKHAND | 829201 | - | Rejected-Technical The offer is not acceptable as per terms and conditions of e-NIT | |
| 3 | Rejected-Technical 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | - | Rejected-Technical The offer is not acceptable as per terms and conditions of e-NIT |
Tender Value
₹14.4 L
EMD Value
₹18,100
Closing Date
18 Nov 2024, 5:00 pmClosed
Staff Officer (EnM), A-C Area
Office of the General Manager, Amrapali- Chandragupta Area, Honhe, Tandwa, Chatra, Jharkhand, 825321
Provision of separate power supply line for air conditioners with control circuit and protection devices at GM office building, Pre-fab House, canteens and Area Quality/ Sales Dept. under Amrapali OCP and GM Unit, A-C Area
2024_CCL_320723_1
GM(A-C)/SO(EnM)/eNIT/24-25/29
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
Amrapali OCP, A-C Area
Please refer Tender documents.
3 documents required · 3 mandatory
₹18,100
21 Dec 2024
7 Nov 2024
19 Nov 2024
8 Nov 2024
18 Nov 2024
8 Nov 2024
8 Nov 2024 - 15 Nov 2024
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying, installing, testing and commissioning of following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 100 A
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.). 12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply of 25 sq.mm 4 core armoured copper cable 650V/1100V Grade as ISI Marked
Supply of 16 sq.mm 4 core armoured copper cable 650V/1100V Grade as ISI Marked
Supply of MCCB, 250A, 38KA, 4-Pole
Supply of MCCB, 160A, 38KA, 4-Pole
200 Amp Busbar 6- Way
Erection cost/ overhead profit 15% ot item no. 08 to 12
Total impact of GST for the purpose of CTC
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .