Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 3 KHATAU APARTMENT TILAK ROAD JOSHI LANE GHATKOPAR EAST MUMBAI 400 077 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.4 Cr+₹3.1 L (2.30%)Rejected-Finance | ₹1.4 Cr+₹3.1 L (2.30%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹1.4 Cr+₹3.7 L (2.73%)Rejected-Finance | ₹1.4 Cr+₹3.7 L (2.73%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹1.4 Cr+₹5.1 L (3.76%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.4 Cr+₹5.1 L (3.76%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹1.4 Cr+₹6.4 L (4.75%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.4 Cr+₹6.4 L (4.75%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
14 Mar 2024, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
SPECIAL REPAIR TO CERTAIN TECHNICAL BUILDING (WORKSHOP AND STORE HOUSE) AT NAD KARANJA
2024_MES_642504_1
84306-K/E8
Open Tender
Civil Works
Item Rate
180 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE (P) (NW) KARANJA
₹2.2 L
30 Mar 2024
15 Feb 2024
16 Mar 2024
15 Feb 2024
14 Mar 2024
7 Mar 2024
Amount
Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering and removal of debris outside MOD complete all as specified and as directed by Engr-in-charge. Note: Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work.
Material and labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and as directed by Engr-in-charge.
Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with waters to remove dusts etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for brushing neat cement slurry with 3 kg/sqm complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type B1 (Using 12.5mm graded stone aggregate) as in concrete padding laid to required slope including finishing the concrete surface fair and even without using extra cement complete all as specified and as directed by Engr-in-charge.
Material and labour for 10mm thick screed bed or bedding layer of mortar in cement mortar (1:3) for laying roof finish as padding finished with WPC 3% by weight of total cement complete all as specified and as directed by Engr-in-charge. Note: WPC shall be measured and paid separately.
Material and labour for applying oil bound bitumen primer @ 0.40 Litre/ Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface complete all as specified and as directed by Engr-in-charge.
Material and labour for APP polymeric membrane min weighting 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) laid on primed surfaces by torch application on method complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 kg/sqm membrane surfaces complete all as specified and as directed by Engr-in-charge.
Supply only integral water proofing compound.
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water etc., at any height using double scaffolding complete all as specified and as directed by Engr-in-charge.
Material and labour for applying ready to mix cement plaster with high quality polymer additives with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, at any height using double scaffolding etc., complete all as specified and as directed by Engr-in-charge.
For 20mm thickness (External)
For 15mm thickness (Internal)
For 5mm thickness (Ceiling)
Removing, chipping and cleaning of existing loose and damaged concrete carefully upto 60mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete including cleaning the surface by air jet and stacking and disposal of unserviceable materials outside the premises etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/ltr and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation works, etc., complete all as specified and as directed by Engr-in-charge.
Cleaning all existing reinforcement bars with wire brush/ rotary wire brush to make entire surface of bars free from rust scales, loose material, dirt etc., and applying alkaline rust converting primer on the existing rebars and allowing it to react with rust and form a corrosion resistant, insoluble protective layer, as per manufacturer’s instructions, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for drilling holes of 12mm dia upto 100mm deep in structural members at the interval of 300mm in staggered manner or along the crack line in RCC structural member including cleaning of the holes by air blower and inserting 12mm dia NRV nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix the nozzles inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 hrs before grouting; cut and remove nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for injecting two part, low viscous, high strength epoxy resin based moisture insensitive liquid using pressure injector with accessories till nozzle refuses to accept the grout including mixing of grout material components in adequate proportions as per manufacturer's instructions by weight batching and grouting the mixed material into the structural member by grouting gun, maintaining desired pressure in the gun by air compressor and maintaining pressure at exit about 2 to 3 kg/cm2 by monitoring pressure guage at exit. The mixed grout should have following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle complete all as specified and as directed by Engr-in-charge.
Material and labour for MS TMT bars for additional reinforcement and shear keys, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed by Engr-in-charge.
For bars above 12mm dia
For bars of 6mm to 8mm dia
Anchoring reinforcement bar (shear bar 150 mm length approximate) in existing RCC member in drilled holes and grouting in position with epoxy resin anchor grout of approved brand, including drilling of holes, cleaning etc., complete all as specified and as directed by Engr-in-charge. Note: Bar shall be measured and paid separately.
Material and labour for providing and applying zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in two coats to the entire circumference surface of bars. The product should confirm carbonation resistance of 2mm and bond strength > 1 N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete) complete all as specified and as directed by Engr-in-charge.
Material and labour for providing, mixing and applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc., the product should comply with ASTM C 881 Type II Grade 2 Class B+C complete all as specified and as directed by Engr-in-charge.
Material and labour for rebuilding the section of damaged RCC elements to its original size in thickness upto required thickness by providing and casting with ready to use non-shrink, cementitious free flow micro-concrete having compressive strength more than 35 N/sqmm (28 days) according to ASTM C 1107-99 including, drilling holes and fixing shear connectors, mixing the microconcrete with adequate quantity of water, placing, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any and curing complete all as specified and as directed by Engr-in-charge.
Material and labour for watertight formwork of timber planks so as to give a rough finish including centering, shuttering, strutting and propping etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for building up the profile of structural members by using polymer modified mortar thickness upto 40mm thickness including leveling profiling etc., complete. Each layer should not have a thickness more than 20mm with epoxy latex based bond coat before each layer complete all as specified and as directed by Engr-in-charge.
Material and labour for prepration of new or previously untreated plastered surfaces of wall and applying two coats of acrylic antifungal paint extiror grade paint over one coat of primer camouflaging patten at any height using double scaffolding complete all as specified and as directed by Engr-in-charge.
Material and labour for 3mm thick wall care putty on wall at any height using double scaffolding complete all as specified and as directed by Engr-in-charge.
Material and labour for 3mm thick wall care putty on ceiling at any height using double scaffolding complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper on walls over a coat of primer at any height using double scaffolding complete all as specified and as directed by Engr-in-charge.
Taking down rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc., including cleaning at any height using double scaffolding complete all as specified and as directed by Engr-in-charge.
Removal of vegetation to prevent free growth etc on external surface of walls at any height etc by taking all necessary precaution including digging out roots of vegetationan filling holes with PCC (1:2:4) type B1 (Using 20mm graded stone aggregate) after application of sutiable chemical using "break manufacutured by M/s denocil company" to avoid regrowth of the vegetation and removing the debris to a distance not exc 50m complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to wall/floors 110mm bore including suitable clamps etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC (SWR) bends any radius 110mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC (SWR) branch piece single (single 'Y') equal or unequal 110mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC (SWR) branch piece double (single 'Y') equal or unequal 110mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC(SWR) junction single (single T') equal or unequal 110mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC(SWR) junction double (double T') equal or unequal 110mm bore complete all as specified and as directed by Engr-in-charge.
Dismantling wall and celling boards (fibers pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed by Engr-in-charge.
Supply and fix for PVC false ceiling consisting of 600x600x5mm thick prelaminated self design PVC sheet of density 600 kg/Cum solid PVC panel including frame work made using aluminium 'T' section of size (25mmX25mm, 19 gauge or 1mm thick) in square pattern of grid size of 600x600mm. The aluminium frame work is supported from the ceiling with the help of GI wire /6mm dia GI (upto 1200mm length) adjusting and maintain for proper level to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasterners 12.5mm dia 40mm long complete etc., The aluminium frame work is supported on side wall with the use of aluminium 25x25mm angles complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) of any descriptionand in any position not otherwise specifically provided for and removing the debris out side MoD land complete all as specified and as directed by Engr-in-charge.
Material and labour for water proofing treatment to sunken floor of RCC slab as following steps complete all as specified and as directed by Engr-in-charge.
After cleanig the surface applying a coat of cement slurry @ 3kg/sqm and 20mm thick cement plaster in 1:4 with WPC @ weight of cement on bottom/sides of RCC.
Applying first coat of chemical pidifin 2K on cleaned plastered surfaces @ 0.86 kg/sqm (min) as recommended by manufacturers. Then provide a layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) over first coat of chemical pidifin 2K as manufactures recommendations. After apply second coat of chemical pidifin 2K @ 0.86 kg/sqm (min) layer glass fibre mesh as recommended by manufacturers.
Spouts of 40mm dia GI pipes light grade projecting at least by 150mm clear of face of the outer wall.
40mm thick PCC 1:2:4 type C1 (Using 20mm graded stone aggregate) mixed with WPC @ 3% by weight of cement shall be provided on bottom.
After laying of CI connections apply two coats of hot bitumen 85/25 grade @ 1.7 kg/sqm over vertical sides and floor of sunken portion.
The sunken portion shall be filled with PCC 1:7:12 type F2 (Using 40mm brick aggregate) after carrying out required test for joints/water proofing. Notes: (i) The treatment shall also be provided over side wall upto a height of 150mm above FFL. (ii) Water proofing treatment will be carried out through authorised applicators approved by GE and testing charges included in quoted rate.
Material and labour for PVC floor trap with hole 75mm dia of out let with grating including jointing to waste pipe with solvent cement fixed in cement concrete type B1 1:2:4 mixed with WPC including taking down the old one etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for PVC multifloor trap 100mm dia of out let with grating including jointing to waste pipe with solvent cement fixed in cement concrete type B1 1:2:4 mixed with WPC including taking down the old one etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for 40mm thick, cement concrete 1:2:4, type B1 (Using 20mm graded stone aggregate) as in floors finished even and smooth using extra cement complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair 15mm angle cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair wash hand basin flat back 550x400mm vitreous china (white) with cantilever CI/ angle iron brackets embedded in concrete block including brass chromium plated waste coupling 32mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair waste coupling 40mm brass chromium plated for glazed ware sinks, basins etc., with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair PVC connections 15mm size with brass nuts both side of length 450mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair PVC waste pipe 40mm low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair PVC waste pipe 32 to 40mm for WHB/sink upto floor trap and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs, 10 litres capacity PVC flushing tank, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, PVC flush pipe, float and handle incl brackets and waste pipe complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs vitreous white china europeon water closet (Pedestal Pattern) including seat cover with mild steel chromium plated or aluminised hinging devices complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs vitreous china urinal full stall type white complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair two in one 15mm bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair 15mm bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting etc., on brick or stone walls etc., including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified and as directed by Engr-in-charge.
Material and labour for fully vitrified ceramic tiles (light shade) 9 to 10mm thick (square/rectangle) polished, area of each tiles not exc 0.36 sqm in floors and skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM (1:6) complete all as specified and as directed by Engr-in-charge.
Material and labour for fully vitrified ceramic tiles (light shade) 9 to 10mm thick (square /rectangle) polished, area of each tiles not exc 0.36 sqm in skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick backing coat in CM (1:3) on fair face of brick or concrete surface complete all as specified and as directed by Engr-in-charge.
Material and labour for coloured non skid coloured ceramic tiles 7 to 8mm thick (square /rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM (1:6) complete all as specified and as directed by Engr-in-charge.
Material and labour for coloured glazed ceramic tiles in vertical surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick backing coat in CM (1:3) on fair face of brick or concrete surface complete all as specified and as directed by Engr-in-charge.
Dismantling of PVC flooring in main workshop area complete all as specified and as directed by Engr-in-charge.
Material and labour for PVC tiles /sheets laminated plain coloured marbled mosaic or mottled finish laid with aooroved rubber based adhesive in floors (3mm) complete all as specified and as directed by Engr-in-charge.
Taking up or down GI tubing 15mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and as directed by Engr-in-charge.
Taking up or down GI tubing 20mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and as directed by Engr-in-charge.
Material and labour for cutting in brick walls chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair GI tubing 15mm bore medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors, bore of pipe 15mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair GI tubing 20mm bore medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors, bore of pipe 20mm complete all as specified and as directed by Engr-in-charge.
Refixing 15mm dia old steel tubing and connections in new or old possition (wall, ceiling and floors etc) complete all as specified and as directed by Engr-in-charge.
Refixing 20mm dia old steel tubing and connections in new or old possition (wall, ceiling and floors etc) complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair brass chromium plated tubular towel rail, 20mm dia, D-type, 60 cm long between flanges complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair chromium plated soap tray any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engr-in-charge.
Dismantling water tanks and removing to store exc 1000 ltrs but not exc 2000 ltrs complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 20mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs urinal spreader of PTMT any colour for fixing with 15mm dia pipe (mimimum weight 60 gms) complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 2000 ltrs capacity rotatonal moulded polyethylene water storage tanks 'ISI marked' triple layer in white colour (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed by Engr-in-charge.
Demolition of brickwork of stone /boulder masonry, build in cement mortar including all quoins, arches, pillars etc., but excluding ashlars facings, dressed stonework and precast concrete articles and removing debris outside MD land complete all as specified and as directed by Engr-in-charge.
Material and labour for pre-cast cement concrete block masonry with solid blocks type C1 1:3:6, exc 10cm in width and setting in cement mortar (1:4) mortar complete all as specified and as directed by Engr-in-charge.
Material and labour for screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to receive tiles complete all as specified and as directed by Engr-in-charge.
Dismantling of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc., and removing the debris out side MD land complete all as specified and as directed by Engr-in-charge.
Material and labour for machine cut cudappah stone slab 45-50mm thick over cement screed base laid and jointed with grey cement slurry mixed pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removing debris outisde MD land complete all as specified and as directed by Engr-in-charge.
Material and labour for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engr-in-charge.
Material and labour for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rolled/ rammed to a true surface complete all as specified and as directed by Engr-in-charge.
Material and labour for 75mm thick, PCC 1:3:6, type C-2 (Using 20mm graded stone aggregate) finished even and smooth without using extra cement as in plinth protection complete all as specified and as directed by Engr-in-charge.
Material and labour for forming 'B' grade construction joint 30mm deep x 10mm wide filled with sealing compound complete all as specified and as directed by Engr-in-charge.
Taking down chowkats or frames (any type-wooden/steel/aluminium) including shutter (without taking off shutters from the frame) area not exc 1.5 sqm each complete all as specified and as directed by Engr-in-charge.
Taking down chowkats or frames (any type-wooden/ steel/ aluminium) including shutter (without taking off shutters from the frame) area exc 1.5 sqm each complete all as specified and as directed by Engr-in-charge.
Supply and fix for anodised and powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e at top, bottom and sides with required EDPM rubber/ neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, C.P brass/ stainless steel screws complete all as specified and as directed by Engr-in-charge.
Supply and fix for aluminium anodised sliding door bolts with hasp and staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts/ aldrops of extruded section or cast aluminium alloy, length of bolt 300mm complete all as specified and as directed by Engr-in-charge.
Supply and fix for butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 100mm size complete all as specified and as directed by Engr-in-charge.
Supply and fix for 150mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs aluminium anodised barrel tower bolt of extruded section of size 200mm length complete all as specified and as directed by Engr-in-charge.
Supply and fix for concealed star lock powder coated for aluminium window fixed as per manufacturers instructions complete all as specified and as directed by Engr-in-charge.
Material and labour for hacking out old broken glass (any thickness, size, quality or description) from wooden or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by Engr-in-charge.
Material and labour for 4mm thick plain glass sheets ordinary quality in any size, each pane fixed with rubber beading or oil putty for windows/ doors/ partition etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for rough cast wired glass 6.40mm thickness and glazing with rubber beading or oil putty in area not exc 0.50 sqm in each pane as in windows/ doors/ partition etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for anodised aluminium grill (DG 104) (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design /pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed by Engr-in-charge.
Material and labour for baroda green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed by Engr-in-charge.
Supply and fix for solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply and fixing in opening including making good the disturbed surface complete all as specified and as directed by Engr-in-charge.
Material and labour for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame madeout of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site complete all as specified and as directed by Engr-in-charge.
Supply and fix for galvanised iron sliding vertical shutters specified including side cover, anchoring rod, hasp and staple and one shop coat of primer erected in indicated, in sliding type complete all as specified and as directed by Engr-in-charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bar, top and bottom runners, brass handles etc., erected in position and securing runners with holdfasts and brackets complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described new or previously untreated surfaces/ aluminium red oxide two coats complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new steel surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zink chrome primer complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair for solid PVC wall lining consisting of 5mm thick plain/ design colour PVC sheet inclusive of solvent and fixing at site on PVC frame complete all as specified and as directed by Engr-in-charge.
Material and labour in repair for kota stone slab 20 to 25mm thick (polised kota stone slab in single piece, bull nosing /rounding to edges of stone slab one edge and two numbers grip line for staircase treads) in staircase, steps, skirting, dado and pillar laid over 20mm thick cement screed for tread in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polised complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair (1.25mm thick lath) steel rolling shutters, with ball bearing including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in indicated, gear operated type with bevel gear box and crank handle complete all as specified and as directed by Engr-in-charge.
Taking down copper /aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, light fitting etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc., complete all as specified and as directed by Engr-in-charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc., for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and as directed by Engr-in-charge.
Material and labour for point wiring in repairs using 1.1 kV grade single core FR-LSH flexible cable, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic unsheathed copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVC concealed conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 20mm NB, including cutting chases, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular coverplates and making good of disturbed surfaces of wall /ceiling /floor, etc., complete all as specified and as directed by Engr-in-charge.
One light point controlled by one switch, with cables 1.5 mm² size.
One additional light point on the same switch, with cables 1.5 mm² size.
One light point controlled by two 2-way switches, with cables 1.5 mm² size.
One fan point controlled by one switch, with cables 1.5 mm² size.
One 6 A socket outlet, on the same board with other switches, with cables 1.5 mm² size.
One 6 A socket outlet, independent, with cables 1.5 mm² size.
One 16 A socket outlet, independent, with cables 2.5 mm² size Notes: (i) Wiring from the DB (distribution box) to terminal boxes for power plugs, fan regulators, switches, socket outlets, etc. shall be deemed inclusive in the quoted rates. (ii) Sunken modular flush sheet metal enclosures shall be measured and paid for as a separate item. (iii) Modular cover plates shall be measured and paid separately.
Supply and fix for modular type 6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal conforming to IS 732:2019 complete all as specified and as directed by Engr-in-charge.
Supply and fix for modular type 6 A 2-way SP switch conforming to IS 3854: 2012 with finger-proof terminal conforming to IS 732:2019 complete all as specified and as directed by Engr-in-charge.
Supply and fix for modular type 16 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal conforming to IS 732:2019 complete all as specified and as directed by Engr-in-charge.
Supply and fix for modular type 2/3 pin combined shuttered type 6 A socket, conforming to IS 1293: 2005 complete all as specified and as directed by Engr-in-charge.
Supply and fix for modular type 2/3 pin combined shuttered type 16 A socket, conforming to IS 1293: 2005 complete all as specified and as directed by Engr-in-charge.
Supply and fix for factory made screwless, dust proof cover plates having superior finish, rounded corners, and solid strength supported by plastic frame behind with flexible wall alignment, horizontal adjustment facility complete all as specified and as directed by Engr-in-charge.
12 module
02 module
03 module
04 module
06 module
Supply and fix for factory made not less than 1.2mm thick sunken, modular flush sheet galvanized metal enclosure haing zinc coating not less than 120 GSM, conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular coverplates complete all as specified and as directed by Engr-in-charge.
1/2 module
03 module
04 module
06 module
Supply and fix in repairs LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs lamp/ angle holder insulated body with back plate for batten fitting complete all as specified and as directed by Engr-in-charge.
Supply and fix for LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sheet metal enclosure for MCB DB’s, phosphatised powder painted double door 200 Amp rated, triple pole and neutral link of 4 way 415 volt AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 415V, 10KA 'B' curve miniature circuit breaker (MCB) of TPN 40 to 100 Amps capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 Amps capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sheet metal enclouser double door for MCB DBs phosphatised powder painted with bus bar 200 Amps rated single pole and neutral link of 4 way 240 Volts AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sheet metal enclouser double door for MCB DBs phosphatised powder painted with bus bar 200 Amps rated single pole and neutral link of 8 way 240 Volts AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sheet metal enclouser double door for MCB DBs phosphatised powder painted with bus bar 200 Amps rated single pole and neutral link of 12 way 240 Volts AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32A capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32A capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs exhaust fan made of metalic body heavy duty complete with louvers shutter, voltage 230V, 50 Hz, RPM 1400, copper winding of sweep 300mm complete including taking down old unserviceable exhaust fan complete all as specified and as directed by Engr-in-charge. Note: The contractor shall deposit the old unserviceable exhaust fan to the store yard of GE (NW) Karanja.
Supply and fixing in repairs ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete including taking down old unserviceable ceiling fan complete all as specified and as directed by Engr-in-charge. Note: The contractor shall deposit the old unserviceable ceiling fan to the store yard of GE (NW) Karanja.
Taking down and refixing of wall mounted fan after minor repairs /finishing of any type and capacity alongwith all electric connections and provision of fixing arrangement i.e. nuts/bolts complete all as specified and as directed by Engr-in-charge.
Material and labour for point wiring in proper colour coding with 1100V grade 1.5 sqmm two single core PVC insulated FRLS, unsheathed cable with multistranded copper conductor conforming to IS-694 part-ll with ISI marked, of white /cream colour, FRLS grade in and including ERW steel conduit, 25mm bore, medium grade, with all accessories concealed in wall /ceiling/ floor /roof, etc., sunk pressed steel, not less than 2mm thick, 50mm terminal boxes with flame proof accessories including 1.5 sqmm PVC insulated, 1100V grade, FRLS, multistranded copper conductor, green colour as continuous earth wire connected to common earth dolly for the following complete all as specified and as directed by Engr-in-charge.
One light/fan point controlled by one flame proof switch.
One flame proof 16 A socket outlet, independent, with cables 1.5 mm² size.
One flame proof 25 A socket outlet, independent, with cables 2.5 mm² size.
Material and labour for point wiring in proper colour coding with 1100V grade 4.0 sqmm two single core PVC insulated FRLS, unsheathed cable with multistranded copper conductor conforming to IS-694 Part-Il with ISI marked, of white/ cream colour, FRLS grade in and including ERW steel conduit, 25mm bore, medium grade, with all accessories concealed in wall /ceiling/ floor /roof, etc., sunk pressed steel, not less than 2mm thick, 50mm deep terminal boxes with flame proof accessories including 4.0 sqmm PVC insufated, 1100V grade, FRLS, multistranded copper conductor, green colour as continuous earth wire connected to common earth dolly for 15 Amps, 3 pin socket outlet on independent board complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs switch flame proof rotary type with termination box in LM6, 16A, single pole 250V including all fitting arrangement complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs flame proof switch socket and plug combined in LM6 cable termination box in LM6, 3/5 pin with cover, 16A, 250V, 2P+earth including all fitting arrangement complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs flame proof switch socket and plug combined in LM6 cable termination box in LM6, 3/5 pin with cover, 25A, 250V, 2P+earth including all fitting arrangement complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc., complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge.
Supply and fix for flame proof exhaust fan size 12", 1440 RPM, 1250 CFM, single phase, 220 volts complete all as specified and as directed by Engr-in-charge.
Supply and fix for energy saving, environment friendly and robust highbay LED luminaire saucer type with high efficacy suitable for ceiling surface/suspended 120 watt fitting complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs FLP-WP MCB DB Double door TPN 4 way with 200 Amps rated copper busbar with incoming 100A MCB TP and outgoing MCB SP 5 to 32 Amps - 10 Nos, MCB SPN 40A- 1 No complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs FLP/WP sheet metal enclosure, double door, vertical type MCCB DB, TPN, 415 Volts, AC, 50 Hz, 06 way complete with 200 Amps rated bus bar, DIN channel and neutral link, suitable for mounting MCB SPN 32 to 63 Amps - 02 Nos, MCB SP 6 to 32 Amps - 16 Nos including fixing arrangement for mounting on wall with MS angle frame, including one MCCB 160 Amps rating 32 KA as incomer complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs on surface of wall /roof/ ceiling ERW rigid steel conduit of size 25mm dia with flame proof acessories with multi refer list stranded copper conductors, Gl wire armoured, heavy duty, ISI marked, FRLS, PVC insulated and sheathed, 1100 volts grade drawn flexible cable of size 2 x 6 sqmm and 1 x 6 sqmm earth wire, connecting and testing complete all as specified and as directed by Engr-in-charge. Notes: (i) The minimum size of ERW rigid steel conduit shall be 25mm. However, higher size shall be used as per the number of conductor to Schedule be passed through the conduit. Engineer-in-Charge shall ensure that proper size of steel conduit is used at site. (ii) Separate conduit shall be used for each submain wiring circuit irrespective of any number of wire. (iii) 3 runs of conductor and one run of conduit shali be measured as one unit viz one RM. (iv) The quoted rate for flame proof conduit accessories deemed to be included in unit rate of above items.
Supply and fix in repairs on surface of wall /roof/ ceiling ERW rigid steel conduit of size 32mm dia with flame proof acessories with multi refer list stranded copper conductors, Gl wire armoured, heavy duty, ISI marked, FRLS, PVC insulated and sheathed, 1100 volts grade drawn flexible cable of size 4 x 6 sqmm and 1 x 6 sqmm earth wire, connecting and testing complete all as specified and as directed by Engr-in-charge. Notes: (i) The minimum size of ERW rigid steel conduit shall be 32mm. However, higher size shall be used as per the number of conductor to Schedule be passed through the conduit. Engineer-in-Charge shall ensure that proper size of steel conduit is used at site. (ii) Separate conduit shall be used for each submain wiring circuit irrespective of any number of wire. (iii) 5 runs of conductor and one run of conduit shali be measured as one unit viz one RM. (iv) The quoted rate for flame proof conduit accessories deemed to be included in unit rate of above items.
Supplying, laying, jointing, inspection and testing in repairs of 1100 volts grade low tension cable with multistranded, H2 grade aluminium conductors, XLPE insulated colour coaded laid up, fillers and/or binder tape where necessary provided with extruded PVC inner sheathed galvanized steel strip armoured and provided with PVC outer sheathed, both inner and outer sheathed shall be of type ST 2 as per IS 5831 1984 and cable shall be confirming to IS 7098 (part-I) 1988 (ammended up to date) and bearing ISI marked size 16 sqmm 4 core complete all as specified and as directed by Engr-in-charge.
Material and labour for MS cable tray, perforated and painted with powder coated of size 250x50x1.6 mm (Thickness), with perforation not more than 17.5% in convenient section, joint with connectors, suspended from the ceiling with suspendors, including bolts, nuts painting suspendors etc., complete all as specified and as directed by Engr-in-charge.
Taking down MS cable tray of any size /type from wall /ceiling alongwith fixing arrangement and refixing the same after taking up minor welding joints duly painted two coats of Hi gloss enamel paint at same place or as directed including fixing arrangements i.e. nuts bolts etc., complete all as specified and as directed by Engr-in-charge.
Fixing only in repairs boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators of any type and size complete all as specified and as directed by Engr-in-charge.
Taking down and refixing of LT panel after repairing of panel box of MCB DBs by means of replacing the hinges and locking arrangement of the existing panel and cleaning all type dust, stains etc., painting with one coat of synthetic enamel paint by spraying complete all as specified and as directed by Engr-in-charge.
Taking down refixing of LT XLPE /PVC cable from wall /ceiling/ cable trenches/ cable trays and refixing at same place or as directed including all fixing arrangements duly fixed on wall /ceiling/ cable trenches/ cable trays using suitable size of sadles and connected to panel /DBs busbar by using suitable size of aluminium lugs/thimbles complete all as specified and as directed by Engr-in-charge.
Material and labour in repairs for submain wiring along with earth wire of size two run of 6 sqmm + one run of 6 sqmm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25mm rigid non-metalic PVC conduit concealed in wall /roof complete all as specified and as directed by Engr-in-charge. Note: Three run of 6 sqmm including one run of 25mm of size casing caping shall be measured as one unit length including taking down of old serviceable sub main wiring.
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete including back plate, heating element, inner copper tank etc, de-scaling back plate and heating element by cleaning with sulfuric acid/ de-scaling compound and painting re-assembling of geysers after repairs carrying out and re-fixing in same position including making good to disturbed portin of walls with CM (1:3) or PCC (1:2:4 Type B1) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc., complete all as specified and as directed by Engr-in-charge. Note: Any type of rubber gasket, rubber washer, screws, insulating tape required shall be deemed to be included in the quoted rate.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron strip 25×4mm by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI medium grade watering pipe 20mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1, 50mm thick precast RCC 1:2:4 type B-1 cover slab reinforced with 8mm dia deformed bar 15cm C/C and suitable handle of 10mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exc 50m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with copper plate 600×600×3.15mm thick electrode buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 20×3mm copper strip by means of steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI medium grade watering pipe 20mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1, 50mm thick precast RCC 1:2:4 type B-1 cover slab reinforced with 8mm dia deformed bar 15 cm C/C and suitable handle of 10mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exc 50m and necessary testing all as shown on electrical plate No.5 of MES SSR Part-I complete all as specified and as directed by Engr-in-charge.
Supply, installation, balancing and commissioning of galvanized steel sheet rectangular/ square shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc., including taking down existing duct of following sizes complete all as specified and as directed by Engr-in-charge.
18 Gauge
20 Gauge
22 Gauge
Taking down air conditioning GI sheet ducts from the wall/ roof including hanging arragement, keep aside for safe custody and refixing the same duly rectified minor bends/ wear tear of insulation at same place or as directed including all fixing arrangements/fasterners/angles complete all as specified and as directed by Engr-in-charge.
Material and labour for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 25mm and including the following complete all as specified and as directed by Engr-in-charge. (a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc., to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) M&L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12mm/ 50mm at maximum intervals of 1.2m.
Supply and fix for supply /return /exhaust air diffusers /grills /louvers (factory made) with gauge not less than 18 SWG (1.2 mm thick) of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removal core complete all as specified and as directed by Engr-in-charge.
Supply and fix for rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with all fitting such as tank nipple and locking arrangement all as specified in SSR Part-I of capacity 2000 ltr as water make up tank for condensor/chiller pipes including supply and fix brass valves with polythene float and fly nut complete scerwed for iron pipe of brass ferrule and fixed of size 40mm complete all as specified and as directed by Engr-in-charge.
Supply and fix for gun metal globe valve iron wheel screwed both end for iron pipe fixed all directed of size 40mm complete all as specified and as directed by Engr-in-charge.
Material and labour for underdeck insulation for RCC roof with bonded fibre glass wool of density 48 Kg/Cum, 75mm thick, suitably factory laminated with aluminium foil having flange on one side, backed up by scrim and kraft paper, comprising of the following (insulating material shall conform to BS-476, Part 4, 5, 6 & 7):- (a) S&F 50x50mm or 75x75mm slotted angles 50mm wide, fixed to the ceiling by means of rawl plug 600mm centre to centre. (b) Supply and draw GI tie wire 22 Gauge from vertical slots, for holding the insulating material in position with and including GI washer. (c) S&F aluminium foil, adhesive tape 50mm for sealing of aluminium foil flanges. (d) Providing additional support to the insulation with and including chicken wire mesh of size 12.5x0.51mm (24 SWG) hexagonal construction, stretched firmly over the insulation and fixed.
Supply and laying testing steel water tubing medium grade with all fitting fixed to wall/ceiling or laid in floor of size 40mm bore complete all as specified and as directed by Engr-in-charge.
Supply and fix for air termination, single pointed aluminium rod 12mm dia 300mm long complete all as specified and as directed by Engr-in-charge.
Material and labour for aluminium strip 25x3.15mm with saddles and fixing screws/mounted on porcelain insulator/laid in trenches for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-charge.
Supply and fix for GI strip 32X6mm complete and buried in ground complete all as specified and as directed by Engr-in-charge.
Supply and fix for test point terminal block made of gun metal or phosphorus bronzesize 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hexegonal headed screw complete all as specified and as directed by Engr-in-charge.
Material and labour for earhing complete with galvanized steel earth plate electrode 600X600X6mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to galvanized earth strip size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI light grade watering pipe 20mm bore, wire mesh charcoal and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1, 50mm thick precast RCC 1:2:4 type B1 cover slab reinforced with 8mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exc 50m and necessary testing all as shown on electrical plate no.5 of MES SSR Part-I complete all as specified and as directed by Engr-in-charge.
Supply and fix for porcelion insulators 15 BMD type T with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in foundation complete all as specified and as directed by Engr-in-charge.
Material and labour for 40mm dia GI tube light grade for passing through cables under the floor, along the wall or along the pole of following bore dia and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified and as directed by Engr-in-charge.
VARDHAMAN CONSTRUCTION COMPANY
jay enterprises
M.K Enterprises
M/s S.D Construction Co
pk Enterprises
Shri Krishna Trading Corporation
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .