Tender Value
₹45.2 L
EMD Value
₹90,360
Closing Date
3 Sept 2024, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINT OF 33 KV MRS NOFRA INDOOR AND OUTDOOR SUBSTATIONS AND VCBS CONNECTED WORKS UNDER AGE EM II OF GE(NW) VASCO
2024_MES_662161_1
85795/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) VASCO
₹90,360
Yes
4 Nov 2024
26 Jun 2024
5 Sept 2024
26 Jun 2024
3 Sept 2024
10 Jul 2024
Amount
M & L for disc type insulator, single disc assembly, heavy polymeric insulator to suit 11 KV HT working pressure of size 145 mm height, 255 mm dia, including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insualtor from position all as specified and as directed.
M&L for pin type heavy polymer insulator to suitable 11 KV HT of working pressure of size 150 mm height, 150 mm dia, including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete including dismantling existing old insulator from position all as specified and as directed.
M&L for Post type heavy polymer insulator suitable for 11 KV HT working pressure including dismantling existing old insulator from position, all as specified and as directed.
Replacement of ACSR type jumpers(appx 1.5 RM in length) of suitable dia incl aluminium lugs of suitable size for HT structures and yards including PVC insulation ppe and cleaning of carbon deposited on joints, applying jelly to each dismantling old jumpers complete all as directed.
Dismantling/Taking down 11 KV HT drop out fuse assembly with DO Fuse unit and Triple pole Air break switch mechanism complete all as directed.
Material & Labour for HT Drop out fuse assembly of 11 KV current Rating of 200 Amps with 2 post type heavy polymer insulator per phase, double stack channel type incl steel base mounting frame, MS Nuts and bolts complete all as specifed and directed.
Material & Labour for outdoor type Gang operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level with GI pipe medium grade,for current rating upto 200 Amps suitable for vertical mounting fixed type complete with 09 Nos HT insulators suitable for HT 11 KV complete all as specified and directed.
All as per Item No.7 above but for current rating upto 400 Amps complete all as specified and directed.
Material & Labour for Lighting Arrestor (LA) Zinc oxide type complete with all fittings transmission class, discharge capacity 10 KA, suitable for 12 KV complete all as specified and directed.
Repairing/Servicing the Air break isolating switch 11 KV 200 Amps by replacing the defective major spares including provn of worn out bolts nuts etc, applying petrollium jelly on moving/fixed contacts all as specified Note :- Major spare will be measured & priced seperately under relevant item of Sch item No. 11
Supply only Airbreak switch spares
(a) Male contact/moving contact blade
(b) Female contact/Fix contact Jaw
(c) Tinned copper Flexible jumper 200A/400A
(d) Ms jumper carrier
(e) Back connector plate
(f) Petroleum Jelly
Supply only in repair HT Fuse element of following rating :-
(a) HT 11 KV, 10 Amp to 25 Amp rating
(b) HT 11KV, 30 Amp rating
(c) HT 11 KV, 40 Amp to 50 Amp rating
(d) HT 11 KV, 60 Amp rating
(e) HT 33 KV, 10 Amp to 25 Amp rating
(f) HT 33 KV, 30 Amp rating
(g) HT 33 KV, 40 Amp to 50 Amp rating
(h) HT 33 KV, 60 Amp rating
Supply and fix cable joiting kit for 11 KV grade cable for Outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium condutor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for Indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for Staright through joint heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L for coarse aggregate taking out old coarse aggregate(broken stone or boulders) of any size and M&L for graded coarse aggegrate of size 40 mm for spreading and levelling at substation yard all as direted and specified
Surface dressing for removing of creepers on stay wires/poles not exc 15 cm deep of soft and loose soil complete all as specified and directed.
M&L for preparation of old cement coated surface, cleaning the surface of the RCC HT/LT pole above the ground level incl coping area with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole and pole number in red when paint all as directed.
Excavation in trenches n.exc 1.5M wide & n.exc 1.5m iin depth for laying & removing of cable any sizes and getting out in hard/dense soil all as specified.
All as per Item No. 19 above but in soft disintegrated rock/laterite rock complete all as specified and directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5 M above the starting point complete all as specified and directed.
Supply Lay dry river sand in trenches for cable protection All as SSR Part I complete all as specified and directed. NOTE : Punned thickness only will be measured & Paid separately
Supply and lay precast concrete cable covers, class HV, type-I flat size 300 x 180 x 40 mm, all as specified and direted.
Supply & Lay, testing and commissioning HT 11KV XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches/floor/duct/fixed on poles/through GI tubing including brass cable glands complete
M&L preparation of old painted external surfaces of HT 2 pole structures consisting of cross arms, GOD assy with pipe, DO fuse assy, clamps etc., of any description and applying one coat of Aluminium paint by mannualy (Except PCC/RCC Pole) all as directed.
Note for Item No 25 to 26 :- This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned inthe structures & Each job will be measured and paid.
Ditto all as per item No 26 here in before but for 4 pole structure all as directed.
M&L preparation of old painted surfaces of HT 11 KV substation Varunapuri consisting of RCC poles / ISMBs, cross arms, GOD pipe, clamps etc., having of any description and applying one coat of Aluminium paint by mannualy (incl structure) except PCC/RCC pole all as directed. The approx particulars are as under :- (a) Angle Iron cross support 75 x 75 x 6mm - 80 RM (b) MS Flat 50 x 4 mm - 24 Rm (c) Channels of size 100 x 50 x 6 mm - 110 RM (d) Channels of size 75 x 75 x 6mm - 220 RM Note :- (a) This rate inclusive of painting all minors items such as clamps, brackets, nuts, bolts and washers which is not particullarly mentioned inthis item. (b) This painting work will be carried out during Holidays only to avoid elect shut down.
M & L preparation of old painted surfaces of HT 33 including ring men/11 KV Feeder MRS at NOFRA consisting of steel poles / ISMBs, cross arms, GOD pipe, clamps etc., having og any description and applying one coat of Aluminium paint by mannually (incl structure) all as directed.
The approx particulars are as under :- (a) ISMB 200 X 100 x 6 mm 12 mtr height as pole - 12 Nos (b) ISMB 200 X 100 x 6mm 5 mtr height as pole - 12 Nos (c) ISMB 200 X 100 x 6mm 2.5 to 3.5 mts height as pole - 15 Nos (d) Angle Iron cross support 75 x 75 x 6 mm - 380 RM (e) MS Flat 50 x 4 mm -24 Rm (f) Channels of size 75 x 75 x 6 mm - 170 RM (g) Channels of size 100 x 50 x 6 mm - 330 RMr (h) Channels of Size 150 x 50 x 6 mm - 400 RMr Note :- (a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned inthis item. (b) This painting work will be carried out during Holidays only to avoid elect shut down.
Material & Labour for Lighting Arrestor (LA) Zinc oxide type complete with all fittings Station class, discharge capacity 10 KA, suitable for nominal system voltage 33 KV and rating 30 KV RMS complete all as specified and directed.
Supply and fix Drop out (DO) fuse unit Polymer insulator assembly expulsion type outdoor single pole 400 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame, GI nut bolts etc with 30 A, HT barrel type fuse complete.
M&L for single post insulator Polymer type, 33 KV with mounting spindle etc. complete all as specified and directed.
M&L for Pin insulator Polymer type, 33 KV with mounting spindle etc. complete all as specified and directed.
M & L for disc insulator Polymer type, 33 KV with hardware fittings etc. complete all as specified and directed.
Supply and fix Cable end termination kit Heat shrinkable type outdoor type, suitable for XLPE cable 3 core, 150 sqmm, 33 KV HT supply, complete all as specified and directed.
All as per Serial No. 35 above, but indoor type, suitable for XLPE cable, 3 core, 150 sqmm, 33 KV HT suppl complete all as specified.
M&L for straight through joint cold shrinkable type suitable for XLPE cable, 3 core, 150 sqmm, 33 KV HT supply complete all as specified.
Supply only HT type Insualting Tape non heat shrinkable type of 38 mm width and 10 Mtr length complete all as specified and directed.
Carryout Material/machinaries & labour for fault finding of 33 KV or 11 KV HT Under ground cable of length up to 1.5 KM in case of cable fault such as short circuit / burn out of earth fault etc including carryout necessary hypot test by injecting high voltage up to 50 KV, complete all as specified and directed. Note :- The contractor shall excavate the fault location and shall confirm the cable fault all as directed.
S&F in repair strip type space heater 110 V, 40/60 watt approx 4"/6" in length complete all as specified and directed.
M&L for Painting on surfaces of outdoor HT feeder pillar box by scrapping or with wire brush after preparing the surfaces by removing dust etc applying two coats of synthetic enamell paint over a coat of red oxide on the external surfaces of HT Feeder pillar box including writing " DANGER, HT 33 KV SUPPLY" all as directed.
Removing grass and bushes including its roots growing at subsation yard and keep the sub station yard neat and clean complete all as specified and as directed. Note :- one length measured in six months.
Supply and fix in repair for mounting indoor type epoxy insulator with nut bolts suitable for 11 KV HT Supply complete all as specified and directed by engr-in-charge.
All as per SI No.43 abov but suitable for 33 Kv HT supply
Taking down old unserviceable/burnt & supply, fix, testing, and commissioning of gang operated rotating type with Earth Switch Polymer insulator air break switch horizontal type mounting complete, double break and operation rod of suitable length 400 A capacity and suitable for 33 KV HT supply, complete all as specifed and directed.
Taking down old unserviceable/burnt & supply, Fixing and testing of metering & protection type current Transformer (CT) resin cast dry type/oil filled type 33 KV outdoor type, oil cooled , wound primary current ration 400-200/5-5A, Accuracy class 0.5 s-5P 10, HSV 36 KV, IL:36/70/170 KVp, STc 25 KA for 1 sec, duly tested, sealed & certified by MRT, Electricity Department, Govt. of Goa together with bimetallic terminal connected for protection including dismantling old existing CT of make :Goa Electric Company complete all as specified and directed.
Taking down old unserviceable/burnt & supply, Fixing and testing of metering & protection type current Transformer (CT) resin cast dry type/oil filled type 33 KV outdoor type, oil cooled , wound primary current transformers(CT) conforming to IS:16227/2016 (Part 1&2) of ratio 200-100/5A, Burden 15-15VA, Accuracy class 0.5s-5P 10, HSV 36 KV, IL:36/70/170 kVp.STC 25 KA for 1 sec., duly tested, sealed & certified by MRT, Electricity Department, Govt. of Goa together with bimetallic terminal connectors for protection including dismantling old existing CT of make :Goa Electric Company complete all as specified and directed.
Taking down old unserviceable/burnt & supply, fixing and testing of metering & 33 KV protection type Potential Transformer (PT), Outdoor Oil Cooled Type, Single Phase, Single Pole, Earth Type, Conforming to IS 16227 : Part 1 (2016) & part 3 (2015), ratio 33 KV/110 V, HSV: 36 KV IL:36/70/170KVP, burden:200VA,accuracy class:0.5, VF :1.2 cont. & 1.5 for 30 Seconds, freq:50HZ insualtion class : A as per approved design by GSEB duly tested. sealed & certified by MRT, Electricity Department, Government of Goa. including dismantling old existing PT of make :Goa Electric Company complete all as specified and directed.
Taking down old unserviceable/burnt & supply, fixing and testing of metering & protection Current Transformer (CT) resin cast dry type indoor type of 11 KV capacity dual ratio 100-50/5 Amps, 15 VA burden class I accuracy for metering and 15 VA/5P-10 for protection including dismantling old existing CT.
Taking down old unserviceable/burnt & supply, fixing and testing of metering & protection Potential Transformer (PT) resin cast dry type indoor type of 11 KV capacity ratio 11 KV/110 V, 200 VA burden including dismantling old existing PT
M & L for overhauling, servicing and preventive maintenance of 33 KV VCB 7 Nos at Nofra substation, 400/630 Amp outdoor type and controlling panel and indoor and including remote and manual operating panels after disconnecting the 33 KV including earthings the entire system properly and cleaning the isolating contacts, removing dust particle from bus bar chamber spout gear mechanism including greasing of the moving parts, cleaning of the moving/stationary contact with CTC. Removing of moisture by menas of hot air blower, renewal of gaskets, nut/bolts etc entire trolly components and replacement of all unserviceable spares, providing the necessary packing material at incoming and outgoing cable entry, inserting in trolly, testing commissioning and putting on the supply on load complete all as required at site and as directed. Scope of works consist of following, the spares required shall be measured follows on items no 53. Note : Unit rate including two preventive maintenance (interval of three months) during the contact period of contract and replacement of HRc fuse, AC and DC MCB of SP/DP at control circuit in each VCB as required at site to make system functional.
M&L for replacement of the following for outdoor VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 make : Crompton Greaves/as approved by GE and all as directed including dismantling old unserviceable one.
(a) Closing coil 30V DC
(b) Tripping coil 30V DC
(c) Spring Charging motor 30V DC
(d) 33KV procelain bushing for VCB Top
(e) 33KV procelain bushing for VCB bottom
(f) LED type indicator lamp assembly
M&L for servicing of 11 KV VCB at Nofra & Varunapuri substation, Map Phase 1, Kirti Enclave and P 404 dismantling cleaning greasing the complete VCB with attached numerical relays, bus bar etc insultion tetsing setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking repairing the current circuit panel wiring, relay testing and commissioning and provision of minor spares as required complete including operational testing and commissoning all as specified and directed.
M&L for replacement of the following for HT VCB 11 KV 800 A 25 KA 250 MVA make: Crompton Greaves/MEI as approved by GE and all as directed including dismantling old unserviceable one.
(a) Closing coil 30V DC
(b) Tripping coil 30V DC
(C) Control Relay 30V DC
(d) LED type indicator lamp assembly
(e) Vaccum Interupter for indoor VCB
(f) Spout incoming side
(g) Spout outgoing side
M&L for primary injection test of 33 KV current transformer and checking the electrical circuits for fault condition and proper functioning and also submitting the test report all as directed by engr in charge.
M&L for primary injection test of 11 KV current transformer and checking the electrical circuits for fault condition and proper functioning and also submitting the test report all as directed by engr in charge.
M&L for primary injection test of 11 KV or 33 KV Potential transformer by applying low voltage on HV Side including testing of secondary wiring for its healthiness. Note :- For item SI No.46 to 57, Testing and calibration of Relays, CTs, PTs etc shall be carried through OEM approved agencies and original test results shall be submitted in triplicate.
Material & Labour for steel cross arms, angles, bracing supports, clamps and back plates fabricated from structual steel sections including nut bolts washers wielding bending cold or hot drilling hole for bolts in any shapes or size as indicated or directed and inclusive of one primer coat and one finishing coat of silver paint.
Material & Labour for ACSR Condutor as per reqd of side for LT/HT connection all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cmx 6 mm thick burried directly in ground earth pit n. Less than 3 mtr deep below the ground level with top edge of the plate n. Less than 1.5m below ground level and filing with cotton soil of volume 0.5 CUM brought from outside and Magnesium sulphate of 100 kg, salt of 100 kg and charcoal of 100 kg and connected to GI Strip 32 x 6 mm by means of bolts, nuts, checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber RCC cover and light grade GI pipe 50 mm dia of required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No.3 of SSR Part -I and as directed including connections and testing on completion.
Taking out old concrete poles of 11M long embedded in concrete unto bottom of foundation and supply & Erect Prestressed concrete pole, 11 m long, 152 X 152 mm at top and 152 x 260 mm at bottom, class-9, erected in position all as directed complete
PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation.
PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping.
Supply, Fixing and testing of Aluminium Tube 1 Inch 3.6M length including dismantling old existing Aluminium Tube
Supply, Fixing and testing of Tee clamp for Aluminium Tube 1 Inch including dismantling old existing Aluminium Tee clamp
Supply, Fixing and testing of Isolator clamp for Aluminium Tube 1 Inch including dismantling old existing Aluminium Isolator clamp
Supply, Fixing and testing of DO clamp for Aluminium Tube 1 Inch including dismantling old existing Aluminium DO clamp
Supply, Fixing and testing of L clamp for Aluminium Tube 1 Inch including dismantling old existing Aluminium L clamp
Supply, Fixing and testing of staright clamp for Aluminium Tube 1 Inch Tube to Tube including dismantling old existing Aluminium straight clamp
Supply, Fixing and testing of Post clamp for Aluminium Tube 1 Inch Tube to Tube including dismantling old existing Aluminium Post clamp
Supply only Lugs of 25 sqmm to 75 sqmm
Supply only Lugs of 95 sqmm to 150 sqmm made up of GI
Supply only halogens bulbs of 500 watts
Supply only halogens bulbs of 1000 watts
Supply only distill water with funnel and droper.
Supply only WD-40 spray of 420 ml for cleaning.
Supply only CRC spray of 500 ml for penetrates, lubricates and prevents corrosion from the metal.
Supply only helmet complete all as specified and directed.
Supply only electrical rubber hand gloves suitable on working pressure of 11 KV all as specified and directed.
Supply only electrical rubber hand gloves suitable on working pressure of 33 KV all as specified and directed.
Supply only fibre glass discharge rod 20 ft long in three section made from best quality suitable for 11 KV working pressure including all accessories all as specified and directed.
Supply only fibre glass discharge rod 20 ft long in three section made from best quality suitable for 33 KV working pressure including all accessories all as specified and directed.
Taking down old NGR (Neutral grounding resistance) and Supply, installation,testing & commisioning of NGR ( Neutral grounding Resistane) for gounding the 3.15 MVA 33/11 KV transformer to make the 11 KV system as neutral insulated ( NGR 11 KV , 63.5 Ohms, 100 Amps , 10 seconds for 33/11 KV , 3.15 MVA transformer.
Taking down/removing of old faulty/ burnt 33 KV pole unit (old type) of capacaity 1250 A round base unit of outdoor VCB at outdoor yard at main incoming VCB & supply ,fixing, installation & commisioning of new 33 KV pole uit assembly of capacity 1250 A pole unit complete all as specified & directed by Engineer-in-Charge.
Dismantling of power transformer outdoor 33 KV of capacity 3.15 MVA's old corroded leaked transformer radiators/fins/stips and replacing the corroded transformer strips/fins radiator 01Nos, after draining out the transformer oil /or by operating radiator valvesand afetr replacement of the corroded/leaked radiators the filling of transformer oil including dehumidifying the transformer oil, commissioning and testing complete including cork sheet a per existing MM thick and main nuts, bolts, washers, drain plug and other minor parts including placing on its original position complete all as specified & directed by Engr-in-Charge.
Taking down of old unserviceable/burnt 33 KV SF6 gas circuit breaker and suplly & installation of new 33 KV SF6 gas circuit breaker – outdoor porcelain clad type. Make :- CG, Siemens, ABB mnufacturer's type designation 40 SFM-40AA standard applicable IEc62271-100,Rated Voltage KV(rms) 40.5, Rated Current (i) Under normal condition at 40 degree celciusambeint Amp upto 3150 , (ii) under site condition at 50 degree celcius ambeint Amp 3150,Rated frequency -50/60 Hz,Number of poles -03, Electrically and manuualy operateed with live tanksuitable for outdoor installationNos of breaks per pole-01Latching current kAp 100, , Rated synmetterical breaking capcity at rated voltage MVA 2806,rated asymmetrical breaking capacity MVA 3347, Closing time ms,/=75, opening time ms,/=35,Arching time ms,/=25, first pole to clear factor 1.5,rated close open time ms,/=60ms,Rated supply voltage and pickup range for trip coil VDC110 or 125 or 220, (70 to 110%),Rated supply voltage and pickup range for close coil VDC110 or 125 or 220, (85 to 110%) etc complete all as specified & directed by Engr-in-Charge.
DURGAI ELECTRICALS (BID ID -3064402)
M/S SANTOSH CONSTRUCTION CO (BID ID -3064220)
OM SAI POWER SYSTEMS (BID ID -3063712)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .