Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Nov 2026, 6:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (East) Ferozepur cantt
GE (East) Ferozepur cantt
Repair/ maint to winter appliances solar water heater/ geysers under GE (East) Ferozepur Cantt
2026_MES_795837_1
8065/GE/E/FZR/2026-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (East) Ferozepur cantt
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (East) Ferozepur cantt
₹50,000
Yes
26 Oct 2026
26 Oct 2026
23 Nov 2026
26 Oct 2026
16 Nov 2026
9 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Disconnecting, dismantling of solar water heating system incl all water and electric connection of capacity 300/200/100 litres per day and refixing the same in existing position after the following repairs and testing complete all as specified and directed:-
(a) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convector sets thoroughly cleaning the complete solar panel of making the tube scale free and reassembling the panel.
(b) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete. | 22 | Each Job | - | - |
| 2 | M&L for Disconnecting, dismantling of solar water heating system incl all water and electric connection of capacity 1000/500 litres per day and refixing the same in existing position after the following repairs and testing complete all as specified and directed:-
(a) Replacement of the worn out/missing nuts bolts , washers, unions, sockets flanges and screw etc complete.
(b) Repair of collector fins incl required welding works etc complete.
(c) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects.
Note:- The Spare parts such as Solar energy collector panel, toughened glass, rubber gasket, hose pipe, insulation for hot water pipe, Assembly ,heating element, thermostat, Water Storage tank, gate valve/float valve, MS Clamp shall be measured & paid separately under respective items. | 10 | Each Job | - | - |
| 3 | Supply only in replacement of complete one solar energy collector panel (FPC) made of aluminium body with toughened glass complete with copper fins incl all accessories capable to heat 100 Litre water per day suitable to be fitted for1000LPD, 500 LPD, 300 LPD & 100 LPD Solar water heating system complete all as specified and directed by Engineer -in -charge.
Make:-Tata BP Solar/Sun Stellar/Inter Solar/RES.
Note: 1 Solar FPC collector can heat 100LPD water. | 18 | Each | - | - |
| 4 | Supply only in replacement of Rubber gaskets made out of fine rubber for existing Solar panel complete to make system air tight dust and water leak proof complete all as specified and directed by Engineer -in -charge. | 25 | RM | - | - |
| 5 | Supply only in replacement of Solar rubber hose pipe 1" (25 mm) inner Dia for hot/cold water for solar system of suitable length as existing size complete with 02 Nos clamps of required size complete all as directed by Engineer-in-charge. | 40 | RM | - | - |
| 6 | M&L for Legging to pipes used for Hot water supply or plumbing all around with 25mm min thick bonded material wool preformed, snap on pipe section of density of 144 Kg/cum confirming to IS 9842 for 15 mm Dia pipe complete all as specified and directed. | 25 | RM | - | - |
| 7 | Supply only Evacuated Tubes of 58×1800 MM or equivalent size as of existing complete all as specified and directed. | 10 | Each | - | - |
| 8 | Supply only Evacuated Tubes of 58×2100 MM or equivalent size as of existing complete all as specified and directed. | 10 | Each | - | - |
| 9 | Supply & fix in repair Hot Water tank Complete Suitable for 500 LPD capacity of Solar Water Heater with provision of electric backup supply incl all accessories, complete all as specified and directed. | 2 | Each Job | - | - |
| 10 | Supply & fix in repair Hot Water tank Suitable for 300 LPD capacity of Solar Water Heater with provision of electric backup supply incl all accessories, complete all as specified and directed. | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
CA8065.pdf
Tender Documents • 1.33 MB
BOQ_892603.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .