Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.2 L+₹2.5 L (6.50%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹42.3 L+₹4.6 L (12.1%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹43.3 L+₹5.6 L (14.8%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹46.4 L+₹8.7 L (23.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
27 Jun 2023, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT OF STREET LIGHT IN AREA 1 AND REPAIR/MAINT OF MISC E/M SERVICE AND MECHANICAL LAUNDARY , INCINATOR AND BOILER AND CONNECTED ALLIED WORK AT AF STN JAISALMER
2023_MES_599332_1
8922/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender docccumetns
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹99,000
Yes
3 Aug 2023
29 May 2023
29 Jun 2023
29 May 2023
27 Jun 2023
13 Jun 2023
30 May 2023 - 1 Jun 2023
Amount
Taking down of existing u/s street light of any type/ Bollard light/Perimeter light /high mast light and building security lights of any type any make from pole , hangers, buildings/Highmast poles at any height etc any type complete after removing from existing mounting arrangements/ street light bracket etc and re-fixing the same after necessary repair / replacement of unserviceable light with new fittings /component etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under relivent items as supply only. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items as supply only. (iii) Any type of Ladder required for dismantling of light from pole/ from hanger/high mast pole shall be arranged by the contractor.
Supply only electronic driver suitable for LED street lights of capacity 25 to 45 watt as per existing complete all as required at site
Supply only electronic driver suitable for LED flood lights of capacity 60 to 90 watt as per existing complete all as required at site
Supply only electronic driver suitable for LED flood lights of capacity 120 watt to 150 watts as per existing complete all as required at site
Supply only electronic driver suitable for LED flood lights of capacity 200 watt to 250 watts as per existing complete all as required at site
Supply only electronic driver suitable for LED bollard/garden lights of capacity 8 watt to 10 watts as per existing complete all as required at site
Supply only surge protection device 10 KV, suitable for LED street lights of capacity 45 watt to 250 watts, single phase, 230 volts, 50 hz complete all as specified and directed
PVC elastomer insulated and fire retardant PVC sheathed, round or flat cable size 1.5 sqmm, 3 core multicore, industrial flexible cable with bright annealed, copper conductor, 1100 volts grade confirming to IS-694-1990 including taking down old unserviceable cable complete all as specified and directed.
Cable Junction box made out of polycarbonate with IP 55/IP 65 protection of size 200mm x 160mm x 98mm, 5 way having terminals for termination of cable with necessary nuts and bolts including 02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and including MCB, 6 Amps, Single Pole, rupturing capacity 10 kA, and including fixing clamp of FI 25x3mm with necessary nuts and bolts including taking down old unserviceable complete all as specified and directed.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor cable 10 sqmm, twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire including taking down old unserviceable cable complete all as specified and directed.
Polypropylene random copolymer concealed (PPR) Pipes, 3 Layer, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing Flat Iron clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from Junction box to light fittings complete for outer dia 20mm (PN-16), including taking up or down old unserviceable pipe complete all as specified and directed.
Energy efficient LED street light fittings of capacity not less than 25 watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections fixed as in repair complete all as specified and directed. Note :- Driver should be BIS registered with "R" marking.
Energy efficient LED street light fittings of capacity not less than 45 watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections fixed as in repair complete all as specified and directed. Note :- Driver should be BIS registered with "R" marking.
Energy efficient LED street light fittings of capacity not less than 60 watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections fixed as in repair complete all as specified and directed. Note :- Driver should be BIS registered with "R" marking.
Energy efficient LED street light fittings of capacity not less than 70 watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections fixed as in repair complete all as specified and directed. Note :- Driver should be BIS registered with "R" marking.
LED flood light of capacity 150 watt, aesthtically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection high output emitter LED for better thermal management of capacity 150 watt (5700 K CCT), system luminous efficacy Im/w grater than or equal to 100 Im/w, high efficiency long life LED module with SMD LED package mounted on MCCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos, integral, isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other safety test as per IS-1985 part-2/sec 13, the LED flood light should be LM-79 report and IES file including taking down old unserviceable LED light fittings complete all as specified and directed.
Supply and fixing in repair energy efficient LED street light fittings of capacity not less than 60 Watt intelligent smart sensor based auto dimmable LED street light with dimming options of 100% to 30% of the rated wattaege on sensing of movement /occupancy within 8 mtr radius, IP 66 Thd<10%, with >100 lumns/watt, housing made from cast aluminium pressure die cast, clear toughened glass and secondary optics, high power LEDs , 140-280 volts 4 KV surge protector inbuilt in driver for maximised protections, driver should be potted type for viberation proof performance & includings making electrical connections complete all as specified and directed.
LED bollard light (Flute decorative type in cylinderical shape with opel acylic diffuser and IP 66 protection with reflector 8-9 watt having fixing arrangements at bottom with necessary nuts, bolts, washers complete, including taking down old unserviceable LED bollard fittings complete all as specified and directed.
LED bollard light inverted Pyramid Tripod type with reflactor 10 watt with soft 360 degree light distribution having fixing arrangement at bottom with neccesary nuts, bolts, washers complete including taking down old unserviceable LED bollard fittings complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out any type of soil complete all as specified and directed.
Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry tibba sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Jodhpur stone rough dressed slab, 40 mm to 50 mm thick, 25 cm to 35 cm wide and not less than 60 cm long dry abuttting each other for protection to under groung cable , complete all as specified and directed .
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking out old unservceable cable complete all as specified and directed.Note for item No. 25.00 to 29.00 : Excavation, sand cushioning, cable protection & GI pipe where usged shall be measured & paid for seperately under relevant items.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking out old unservceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking out old unservceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking out old unservceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 70 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking out old unservceable cable complete all as specified and directed.
Galvanized steel water tubing light grade of 40mm bore with & including all fittings with clamp of 25x3mm flat iron welded to pipe fixed to wall/pole/ceiling or laid in floor or under road including taking out old unservceable pipe complete all as specified and directed.
Galvanized steel water tubing light grade of 50mm bore with & including all fittings with clamp of 25x3mm flat iron welded to pipe fixed to wall/pole/ceiling or laid in floor or under road including taking out old unservceable pipe complete all as specified and directed.
Steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410 SP 31 of 9 mtr long including painting of pole with one coat of red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint including dismantling of existing pole complete all as specified and directed , in and including the following specifications:-(i) Excavation in any types of soil upto 1.7,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding for 200 mm base and casing of pole 600 x600mm upto GL level complete all as specified and directed . (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate of size 600x600x450mm from GL level upto coping complete all as directed at site (iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed .
MS Cross arms , bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer in and including taking down of old cross arms complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of red oxide primer only.
Dismantling/taking down of old existing street light switching system an Supply, fixing, connecting and testing of Automatic street light switch using infrared sensor based nature switch for automatic switching of street lights, nature switch operation should be based on natural light lux level. Required illumination level for switching on is <30 lux and for switching off >10 lux. The sensor should also have part night operation facility for 4-12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54. The circuit should be suitable enough to take 8 KW 3 Phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 and incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10 sqmm copper conductor wire and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete all as specified and directed. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of Enclouser :-Sintex or Equivalent
Cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 3-cm from top of the road surface complete all as specified and directed .
Plain cement concrete (1:2:4) Type B-1 (using 20 mm graded granite stone aggregate) as in copping of poles, path to LT panels, bollard light (bollard lights to be refixed after repair to base) and other indicated work including necessary form work and finished the surface and including dismantling of old PCC complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
Bracket made out of 40mm bore galvanized steel tubing medium grade 1.50m long including bending if required as direct, 02 Nos clamps made out of MS flat iron 40x6mm of including suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts including taking down old unserviceable complete all as specified and directed.
Taking down gear assembly of EOT cranes of capacity 1 to 3 Ton, connected induction motor, servicing, greasing of motors etc complete and dismantling gear box assembly taking out gear and other worn out parts, replacement of worn out parts refilling of gear oil, over hauling, oil seal replacement including lathe work as required at site re-assembly, re-fixing the same and testing including repair of EOT cranes installed above the height of 5.0m from working level, thoroughly cleaned of all dirt, grease, scale and rust by shot blasting or chemical cleaning methods, removing old paint from EOT cranes and attachments parts such as double girders, motors, crane rail, Gearbox cabinet, LT panel board and all moving parts. A single coat of primer shall be given to all parts exposed to the weathering effects and two coats of paint as approved by GE for indoor/outdoor cranes shall be given on all primer painted surface. The bright exposed parts of the crane shall be given one coat of rust inhibitor. Interior of all gear boxes shall be painted with one coat of oil resisting paint. Writing the technical details of respective crane as per existing data available on each cranes with paint as approved by GE, complete all as directed . The capacity of Crans with their locations are as under :- Note : (Spare parts shall be measured and paid seprately)
All as srl item No 39.00 here in above but 5 Ton 10 Ton
Supply & fix only Spares/Components after approval and as directed by Engineer-in-Charge for Cranes/Hoists of Capacity 01 TON TO 3 TON :
Magnetic Coil.
Over load relay 0.6 to 1 Amps Make- L&T/Siemensor other equivalent make as approved.
TP Contactor 25 Amps,ML 1.5, 110 Volts, Coil Voltage Make- L&T/Siemensor or other equivalent make as approved.
Brake Pads.
Push Button with auxiliary contacts Make- L&T/Siemensor or other equivalent make as approved.
Limit Switch with two contacts in oil tight die cast aluminium housing Make- L&T/Siemensor or other equivalent make as approved.
Drive as per existing
Supply & fix only Spares/Components after approval and as directed for Cranes/Hoists of Capacity 5 to 10 TON :-
Oil Seal
Gasket
Brake for CT/LT Coil.
Pedant Push Button Make –Make- L&T/Siemensor or other equivalent make as approved.
Pedant Push Button with auxiliary contacts Make – Make- L&T/Siemens or other equivalent make as approved.
No Volt Coil 1100 volts Make L&T suitable for contactor ML-4. ke- L&T/Siemens or other equivalent make as approved.
Carbon Brushes.
Over Load Relay 42 Amps ke- L&T or other equivalent make as approved.
Contactor 45 Amps, 110 volts, ML-4 Make – ke- L&T or other equivalent make as approved.
Drive as per existing
Load Testing of capacity 01 TON to 03 TON HOT cranes/EOT Cranes with full load and 25% over load all as specified in IS No 301 of 1977 and 3177 of 1977 and writing the date of load testing all as directed for the following capacity :-(Note :- Load will be provided by the Department except EP shop the Contractor will be responsible for provision of load materials in EP shop.
All as srl item No 43.00 here in above but capacity 10 Ton
Supply, fixing and connecting conventional optical smoke Detectors Complying with and type certified complete with standard base for conventional detector complete all as specified and directed
Supply, installation, commisioning and testing 02 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, installation, commisioning and testing 04 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, fixing and connecting conventional type manual call point resettable complete all as specified and directed
Supply, fixing, connecting and testing conventional wall sounder complete all as specified and directed
Supply and fix Remote response indicators complete all as specified and directed
Supply, fixing and connecting in replacement analog addressable type smoke detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed
Supply, fixing and connecting in replacement analog addressable type multi criteria combination of (smoke & heat) heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed
Supply, fixing and connecting in replacement analog addressable type heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed .
Supply installation, testing & commissioning in replacement one Loop Fire Alarm control Panel (CFX-Plus), expandable upto 4 Loop as per site requirement complete with all connected accessories required for making functional of the fire alarm control panel, networkable, Graphic LCD, display complete all as specified and directed.
2x1.5 sq. mm +1x1.0 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through existing conduit/casing caping of any type or size in surface/recessed including taking down existing wiring complete all as specified and directed.
2x2.5 sq. mm +1x1.5 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through existing conduit/casing caping of any type or size in surface/recessed including taking down existing wiring complete all as specified and directed.
Supply, fixing, connecting and testing copper control cable 12 core, 1.5 sqmm, PVC insulated, PVC sheathed, 1100 volts grade complete all as specified and directed
Supply, fixing, connecting and testing copper control cable 10 core, 1.5 sqmm, PVC insulated, PVC sheathed, 1100 volts grade complete all as specified and directed
Air termination, single pointed copper rod 12 mm dia and 300 mm long all as including taking down existing specified and as directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw including taking down existing specified and as directed.
Copper strip 20x3.0 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down existing specified and as directed.
Porceiline insulator suitable for fixing earthing strip to the wall / floor etc all as specified and as directed .
General service including repairs required for electrically operated barrier heavy duty metal with remote by pass arrangement (length 6.0 metre), operating capacity 300 NM Torque and motor capacity 130 watt Single pole including overhauling of complete assembly, replacement of worn out/ unserviceable parts complete including greasing/ cleaning all as directed
Supply installation , commissioning and testing of tripode ring earthing system to construct earthing of resistance not more than 01 ohm mainly consisting of 250 micron copper bonded high tensile low carbon steel rod earth electrode of minimum 3.0 m length , 17 mm dia with copper strip of size 20 x 3.15mm for inter connection to earth electrode and for connected to equipment as per required length, with set of steel nut and bolts, earth enhancement material of mainly consisting of Jamfill compound 50 kg (25 x 2 bags in each pit) jam fill to provide maximum contact between the electrode and jam fill compound. Back fill compound. Jam fill compound shall be eco friendly having RDSO certification, Earthing shall be maintenance free and does not require regular manual addition of water and PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) earth chamber and Earth Pit cover 300 x 300mm . Note: Copper strip of size 20 x 3.15mmrequired to connect the electrode shall be passed through GI pipe of suitable size. Note :- (i) Quoted rate deemed to include the cost of excavation and earth work, PCC pit, funnel and cover etc. (ii) copper strip beyond earth test point shall be mearued and paid seperately
Repair /maintenance/servicing of oil fired incinerator installed at 15 AFH, havind 20 Kg/hours brning capacity horizontal/vertical type comprising of primary chamber, secondary chamber designed on "controlled air" incineration principle and provided with minimum temperature of 100 degree centigrade in the primary chamber and 1200 degree in secondary chamber , one fully automatic pressure jet type burner for each chamber chamber of mild steel plate of adequate thickness (minimum 5mm thick ) 30 metre high chimney exhuast system high pressure ventury scrubber, PLC base control panel droplet separator etc including all other accessories and piping equipments and civil works required for installation of incinerator chimney complete all as specified and directed.Notes :1. The entire incinator plant is required to be kept serviceable during the entire period of CA, 2. 30 days duration of months shall be considered as one job ie from the date of work order plus 30 days will be measured as one job and so on upto ten months. 3. The Cost of spare parts (except the spare considered in CA as supply only), labour charges shall be deemed to be included in unit quoted rates, All repair work shall be carried out by rep of OEM/Authorised service centre of OEM
Supply only Spares/Components after approval and as directed for the following :-
PLC based control panel droplet separator
Fuel pump suitable size
Emergency stack push button of power failure.
Interconnection piping
Valves
Dampers and fiittings etc
Garbage dumping jaali made out of stainless steel rod, steel grade 410(Melting range1480-1530 degree centigrade) not less 8mm dia stain less steel rod complete all as specified and directed.
Repair/maintenance/serving of laundry plant consisting of under mentioned plant/machinery/equipments including replacement of spare parts such as nuts, bolts, washers, oil, greaseing, PVC pressure pipe, PVC pipe connector etc and any other parts necessrily required for keeping the plant functionalother than major parts as mentioned in subsequent items for the following equipments installed at AFH Jaisalmer. (a) Industrial washer extractor, heavy duty high spin, Model AXS 30 of capacity 30 Kg (steam heated) - 02 Nos (Fabcare) (b) Drying tumbler, front loading type, open pocket SS inner cyliner, reversible, double walled out drum Model DS300 of capacity 30 Kg (steam heated) (Fabcare) - 01 Nos (c ) Flat work roatry drying ironer, chest heated, front feed front return penumatically operated ironing chest, adjustable ironing pressure, varriable freqency, inverter drive, conveyer belt feed, 530 dia x 3000L Model FRS53-300 (Steam heated) Fabcare- 01 Nos (d ) Vacuum finishing table Model VF 120, table top size 1200x750mm electric steam iron model ERS220, teflon shoe Model TF220 Fabcare- 02 Nos (e ) Dry linen trolley, overall size 850x650x1670mm heigh Model DTR50 Fabcare- 02 Nos (f) Air compressor reciprocating type, tank capacity 100 litre, 8kg/sqcm, fully automatic complete with driving mechanisim, Elgi -01 Nos (g) Steam boiler of capacity 200 Kg with all accessories, including plumbing work, Thermax - 01 Nos :.Notes :(a). The entire laundry plant is required to be kept serviceable during the entire period of CA, (b). 30 days duration of months shall be considered as one job ie from the date of work order plus 30 days will be measured as one job and so on upto ten months. (c) . The Cost of spare parts (except the spare considered in CA as supply only), labour charges shall be deemed to be included in unit quoted rates, All repair work shall be carried out by rep of OEM/Authorised service centre of OEM
Supply only Spares/Components after approval and as directed for the following :-
Transformer suitable for 30kg laundry machine
Sequence Controller RBL (Oil Burrner Part)
Temperature 101 controller
Solenoid vlave
Rubber
Single piston water pump with safety valve and vessel.
Steam glove/gate valve 25mm IBR
Steam glove/gate valve 20mm IBR
Ball valve 15mm
Water limit switch
Steam pressure switch
Blow down switch
Steam pressure guage 4 inch
Fuel pressure guage 2.5 inch
Hose pipe high pressure 1 inch
Hose pipe high pressure 3/8 inch
Steem heating coils stainless steel tube as per sample for boiler of 200 kg Thermax
Burner suitable for 200 kg thermax boiler as per sample
V belt as per sample
Pnumatic pipes & fittings suitable for FABCARE make drying tumbler as per sample
Heater suitable for FABCARE flat bed press as per existing
GIC timer suitable for FABCARE make flat bed press as per existing
Glasss with rubber packing and ss screw suitable for Fabcare make drying tumbler as per existing
Ball valve 25mm IBR
Gate valve 50mm dia
Spring flat bed press main for flat bed press suitable for fabcare falt bed press as per existing
Supply, fixing, connecting to the equipment/plant and testing MS flanged pipe, 150mm dia heavy duty in and including all fittings like bend elbow, flange of size not less than 8mm thick nut bolts, washers for steam supply in and including providing rock wool all around the MS pipe of 50 mm thick and providing aluminium cladding over glass wool to protectect heat loss of steam, density of glass wool should not be less than 100kg/cum complete all as specified and directe. Note : 1. All MS pipe is required to be connected properly with all necessary connecting material to the laundry plant to make it functional. The cost of the same is deemed to be included in unit quoted rates.
All as srl item No 71.00 here in above but 65mm dia
All as srl item No 71.00 here in above but 40mm dia
All as srl item No 71.00 here in above but 32mm dia
All as srl item No 71.00 here in above but 20mm dia
All as srl item No 71.00 here in above but 15mm dia
SANJOLI CONSTRUCTION COMPANY
M/s Shree Construction Company
S.D. And Company
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .