Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹19.2 L+₹1.1 L (6.05%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹19.4 L+₹1.3 L (6.97%)Rejected-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 4 | L4₹19.5 L+₹1.4 L (7.47%)Rejected-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L4 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 5 | L5₹19.8 L+₹1.7 L (9.15%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L5 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| Sl No | Description | Qty | Unit | C SRINIVASAN L4 | rc enterprises L1 | PSK Enterprises L2 | RK ENTERPRISES L5 | m/s SRI VALLI ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour for checking and identifying complaints of window / split type ACs of any make and capacity and making it 100% functional complete all as specified and as directed
Note:
(a )Spares required for replacement for the functioning of the AC shall be measured and paid separately (under relevant item) as supply only.
(b) Labour for rectifying water leakage from ACs also included in the quated rate. (c) Quoted rates includes labour cost for taking down old unserviceable items and fixing new one. | 540 | Each Job | 790 ₹4,26,600 | 745 ₹4,02,300 Lowest | 750 ₹4,05,000 | 825 ₹4,45,500 | 780 ₹4,21,200 |
| 2.00Taking out existing burnt/ unserviceable Compressor unit from the following Air conditioner rotary / reciprocating type and replacing the same with new factory built hermatically sealed Compressor unit including necessary accessories and mounting materials ,carry out leak test by charging with CO2 / dry nitrogen gas and arresting leakages if any by welding work etc., evacauting the system and charging of R-22 / R410 / R32 Refrigerant gas upto recommended level after ensuring leak proof condition and testing complete for the following Air conditioners all as specified and as directed. Make: LG/Hitachi/Highly/Voltas/Blue star/Sriram as per the site sample requirement. | ||||||||
| 2.01 | 1.5 TR capacity of Split / Window type Airconditioner | 3 | Each Job | 17,200 ₹51,600 | 16,500 ₹49,500 Lowest | 18,000 ₹54,000 | 18,000 ₹54,000 | 18,000 ₹54,000 |
| 2.02 | 2.0 TR capacity of Split / Window type Airconditioner | 3 | Each Job | 18,800 ₹56,400 | 18,000 ₹54,000 Lowest | 20,000 ₹60,000 | 19,500 ₹58,500 | 18,000 ₹54,000 Lowest |
| 3.00 | Servicing of Split / Window type AC 1.5/ 2 TR capacity of any make/ model by taking out the AC, Cleaning of evaporating coil, condensing coil with cleaning chemical and water by pressure washing pump and brush to remove dust including cleaning of filter, greasing/oiling of motors and checking of electric circuit for smooth functioning of AC including replacing damaged/unserviceable accessories/spare parts complete.
Note:
(a) Rate quoted deemed to include labour cost for taking down, repair and replacement of spares.
(b) The spare parts required for replacement shall be measured and paid Separately as supply only under relevant items of sch here-in-after.
(c) Once service the AC, contrctor shall be resposible for blockage of filter, condenser coil and evaporator coil complaints for next 3 months without any extra payment. | 360 | Each Job | 1,050 ₹3,78,000 Lowest | 1,080 ₹3,88,800 | 1,250 ₹4,50,000 | 1,150 ₹4,14,000 | 1,150 ₹4,14,000 |
| 4.00 | Supply only new Blower motor with mounting material single phase, 230V, 50Hz for 1.5 / 2.0 TR capacity of Split type AC complete. | 3 | Each | 2,750 ₹8,250 | 2,700 ₹8,100 Lowest | 2,750 ₹8,250 | 2,900 ₹8,700 | 2,800 ₹8,400 |
| 5.00 | Supply only new blower motor with mounting material single phase, 230V, 50Hz for 1.5 / 2.0 TR capacity of Window type AC complete. | 1 | Each | 3,100 ₹3,100 Lowest | 3,200 ₹3,200 | 3,200 ₹3,200 | 3,500 ₹3,500 | 3,400 ₹3,400 |
| 6.00 | Supply only Air filter pad of suitable size and specification as per existing filter for 1.5 TR /2.0 TR capacity AC complete. | 9 | Each | 330 ₹2,970 Lowest | 360 ₹3,240 | 670 ₹6,030 | 395 ₹3,555 | 385 ₹3,465 |
| 7.00 | Supply only running capacitor for 1.5 / 2.0 TR split type AC, 36 + 5 MFD / 40 + 6 MFD / 45 + 5 MFD / 50+5 MFD 230 V AC complete. Make : Hills/Concap/Dvm | 90 | Each | 880 ₹79,200 Lowest | 900 ₹81,000 | 1,000 ₹90,000 | 900 ₹81,000 | 920 ₹82,800 |
| 8.00 | Supply only metallic/ PVC fan blade for outdoor unit as required of existing size and type/model for 1.5 and 2.0 TR split type AC complete. | 3 | Each | 1,800 ₹5,400 Lowest | 1,800 ₹5,400 Lowest | 1,900 ₹5,700 | 2,000 ₹6,000 | 2,000 ₹6,000 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
4 Aug 2025, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIRS TO COOLING APPLIANCES SPLIT WINDOW TYPE AC WATER COOLERS REFRIGERATOR DEEP FREEZER AND VOLTAGE STABILIZERS AT INS RAJALI ARAKKONAM
2025_MES_719670_1
8479E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer M NAS Arakkonam
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹38,000
Yes
10 Sept 2025
10 Jul 2025
6 Aug 2025
10 Jul 2025
4 Aug 2025
24 Jul 2025
Amount
Labour for checking and identifying complaints of window / split type ACs of any make and capacity and making it 100% functional complete all as specified and as directed Note: (a )Spares required for replacement for the functioning of the AC shall be measured and paid separately (under relevant item) as supply only. (b) Labour for rectifying water leakage from ACs also included in the quated rate. (c) Quoted rates includes labour cost for taking down old unserviceable items and fixing new one.
Taking out existing burnt/ unserviceable Compressor unit from the following Air conditioner rotary / reciprocating type and replacing the same with new factory built hermatically sealed Compressor unit including necessary accessories and mounting materials ,carry out leak test by charging with CO2 / dry nitrogen gas and arresting leakages if any by welding work etc., evacauting the system and charging of R-22 / R410 / R32 Refrigerant gas upto recommended level after ensuring leak proof condition and testing complete for the following Air conditioners all as specified and as directed. Make: LG/Hitachi/Highly/Voltas/Blue star/Sriram as per the site sample requirement.
1.5 TR capacity of Split / Window type Airconditioner
2.0 TR capacity of Split / Window type Airconditioner
Servicing of Split / Window type AC 1.5/ 2 TR capacity of any make/ model by taking out the AC, Cleaning of evaporating coil, condensing coil with cleaning chemical and water by pressure washing pump and brush to remove dust including cleaning of filter, greasing/oiling of motors and checking of electric circuit for smooth functioning of AC including replacing damaged/unserviceable accessories/spare parts complete. Note: (a) Rate quoted deemed to include labour cost for taking down, repair and replacement of spares. (b) The spare parts required for replacement shall be measured and paid Separately as supply only under relevant items of sch here-in-after. (c) Once service the AC, contrctor shall be resposible for blockage of filter, condenser coil and evaporator coil complaints for next 3 months without any extra payment.
Supply only new Blower motor with mounting material single phase, 230V, 50Hz for 1.5 / 2.0 TR capacity of Split type AC complete.
Supply only new blower motor with mounting material single phase, 230V, 50Hz for 1.5 / 2.0 TR capacity of Window type AC complete.
Supply only Air filter pad of suitable size and specification as per existing filter for 1.5 TR /2.0 TR capacity AC complete.
Supply only running capacitor for 1.5 / 2.0 TR split type AC, 36 + 5 MFD / 40 + 6 MFD / 45 + 5 MFD / 50+5 MFD 230 V AC complete. Make : Hills/Concap/Dvm
Supply only metallic/ PVC fan blade for outdoor unit as required of existing size and type/model for 1.5 and 2.0 TR split type AC complete.
Supply only new suction / delivery line service valve of same size including welding of joints for 1.5 and 2.0 TR split type AC complete.
Supply only new PCB circuit board complete with remote control as per existing model/type for 1.5 / 2.0 TR split AC complete. Make : LG/Voltas/Hitachi/Blue Star/Tempair/Dykin as per the site sample
Supply only new PCB circuit board complete with remote control as per existing model/type for 1.5 / 2.0 TR Inverter type split AC complete. Make : LG/Voltas/Hitachi/Blue Star/Dykin as per the site sample
Supply only 3 core PVC sheathed copper cable of size 2.5 Sqmm suitable for 1.5 TR Split type AC complete all as specified and as directed by Engr-in-charge. Make : Polycab/Havells/Kei
Supply only 5 core PVC sheathed copper cable of size 4 Sqmm suitable for 2.0 ton Split type AC complete all as specified and as directed. Make : Polycab/Havells/Kei
Supply only standard flexible length drain pipe suitable for 1.5 / 2.0 TR split AC.
Supply only rigid / flexible drain pipe suitable for 1.5 / 2.0 TR split AC.
Supply only new Blower of existing size and make for any capacity Split Air Conditioner Indoor unit including taking down the existing one complete. Make : As per the site sample
Supply only Condensed water tray of existing size and make for split AC indoor unit including taking down the existing complete.
Supply only running Capacitor 2.5 MFD / 3.5 MFD / 4 MFD for fan motor including taking down the existing one complete all as specified and as directed. Make : Hills/Keltron/Dvm/Havells
Supply only Copper Condenser coil for 1.5 / 2TR split / Window type AC complete.
Supply only Condenser fan motor single phase for 1.5 / 2 TR split AC complete. Make : As per the site sample
Supply only Copper Evaporator coil suitable for 1.5 / 2 TR split ACcomplete. Make : As per the site sample
Supply only Magnetic contactor suitable for split / Window type AC suitable for 1.5/2 TR complete.
Supply only louver motor (swing motor) suitable for spit type ACs any capacity/model as per existing complete.
Supply only new Metal Plug top, 240 V including removal of old complete . Make: ABB / Schneider / Siemens / Legrand
Supply only Industrial new Plug and Socket for AC distribution box and MCB upto 25A / 32 A 'C' curve, 240 V including removal of old complete. Make: ABB / Schneider / Siemens / Legrand
Supply only Split AC outdoor unit plastic/ metalas protection grill per existing model and type
Note for Item Nos 04 to 26:Labour charges deemed to be included in the rate quoted for the item No.01 here in before
Material and labour dismantling of old unserviceable PCB and Repairing of PCB and refixing it in AC complete for 1.5 / 2.0 TR split AC complete.
Material and labour dismantling of old unserviceable PCB and Repairing of PCB and refixing it in AC complete for 1.5 / 2.0 TR inverter type split AC complete.
Material and labour for Charging of refrigerant R-22/R-410 A/R-32 including leak detection with nitrogen,welding and refitting the same in entire system, including replacing capillary tube for 1.5/ 2.0 TR split / Window AC including testing complete.
Material and labour for Painting of AC outdoor unit by cleaning and preparation of old painted surfaces of Split type AC out door unit and apply spray painting complete with two coats of synthetic enamel paint and marking SM/ MES Nos, re-fixing the out door unit of split type AC complete.
Material and labour for marking SM / MES Nos on the split type AC Window Type AC, Water cooler, Refrigerator, etc.with synthetic enamel paint of approved make and tint with letter size/type complete.
Supply and fix new Copper pipe of following size including taking out existing old damaged copper pipe complete.
Copper pipe "1/4" outer dia
Copper pipe "3/8" outer dia
Copper pipe "1/2" outer dia
Copper pipe "5/8" outer dia
Supply and fix split type AC indoor unit with remote suitable for following capacity of make/model as exists/required at site including taking down the existing damaged unserviceable one and depositing to MES complete. Make : Carrier/Voltas/LG/Blue star/Hitachi
Removing existing damaged stand with fixing kit of outdoor unit of split AC with stand and Supply and fix new stans with fixing kit complete.
Supply and fix split type AC out door unit with all accessories suitable for following capacity of make/model as exists/required at site including taking down the existing unserviceable one and depositing to MES complete. Make : Carrier/Voltas/LG/Blue star/Hitachi
M&L for Shifting of AC by Dismantling and taking down carefully the existing indoor and out door units of tonnage 1.5/2 TR from the existing positions for complete servicing, cleaning, greasing & maintenance and refixing the outdoor and indoor units after servicing / maintenance with necessary copper tubing with insulation including gas charging if required and connecting with stabilzer etc., and testing for its proper functioning complete. Note: (a) Spares required and gas shall be measured and paid under relevant items of schedule. (b) Labour charges for replacing spares/components is deemed to be included in the rate quote
Supply and fix MCBs SP 6-32 Amp, 240V 'C' curve 10KA. including taking down the existing onecomplete. .Make: ABB / Schneider / Siemens / Legrand
Supply and fix synthetic rubber tube insulation of thickness 9 mm and following internal diameter for insulating refrigerant copper piping of split AC units including taking down the existing complete.
Internal diameter 6.0 mm (1/4")
Internal diameter 9.0 mm (3/8").
Internal diameter 13.0 mm (1/2").
Internal diameter 16.0 mm (5/8").
Supply and fix new PCB complete with components of following capacity Voltage stabilizer including taking out defective PCB (Printed Circuit Board) complete with components of stabilizer and complete.
Voltage stabilizer of Capacity 4 KVA / 5 KVA
Voltage stabilizer of Capacity3 KVA.
Supply and fix new auto transformer for voltage stabilizer of following capacity including taking out defective / burnt auto transformer of stabilizer and complete all as specified and as directed
Voltage stabilizer of Capacity 4 KVA / 5 KVA
Voltage stabilizer of Capacity3 KVA.
Supply and fix new Relay for voltage stabilizer 3.0 KVA / 4.0 KVA / 5.0 KVA capacity complete all as specified and as directed, including taking out defective relay.
Supply and fix electric connector 20 Amps in Voltage stabilizer including taking out burnt connector, complete all as specified and as directed
Supply and fix 3 pin Plug top 15 Amps including taking down the existing unserviceable burnt one complete all as specified and as directed . Make: Anchor/Cona/ Leader
Servicing of water cooler 40/80 ltrs capacity , Cleaning of evaporating coil, condensing coil with water and brush to remove dust and checking of electric circuit for smooth functioning of Water coolers complete. Note: (a) Spares required shall be measured and paid under relevant items of schedule as supply only (b) Labour charges deemed to be included in the rate quoted for this item.
Supply only of suitable Compressor for water cooler 40/80 ltrs including M&L leak test and gas charging etc., with necessary connecting arrangements complete . Note :Labour charges deemed to be included in the rate quoted for the item No.46 here in before
Supply only of the following items for water cooler 40/80 ltrs with connecting and necessary arrangements complete all as specified and as directed by Engr-in-charge Note :Labour charges deemed to be included in the rate quoted for the item No.46 here in before
Supply only Relay and OLP for water cooler
Supply only Thermostat for water cooler
Supply only SS Drain tray for water cooler
Supply only Drain hose for water cooler
Supply only Float valve assembly size 15mm
Supply only condensor fan motor suitable for 40/80 Ltrs capacity water cooler
Supply only condensor fan motor blade suitable for 40/80 Ltrs capacity water cooler
Supply only capacitor 10 MFD, 230 V, 50 Hz
Supply and fix push cock steel made suitable for water cooler
Supply and fix in replacement of suitable Compressor for refrigerator 465 ltrs capacity including M&L leak test and gas charging etc, with necessary connecting arrangements all as specified and as directed
Supply and fix in replacement of Relay and OLP for Refrigerator of any capacity complete all as Specified and as directed
Supply and fix in replacement of PCB suitable for Refrigerator of any capacity complete all as Specified and as directed
Supply and fix in replacement of Evaporator fan motor suitable for Refrigerator of any capacity complete all as Specified and as directed
Supply and fix in replacement of suitable Compressor for Deep Freezer 400 ltrs capacity with gas Charging ,connecting and necessary arrangements all as specified and as directed.
Supply and fix condensor fan motor suitable for Deep Freezer 400 ltrs capacity
Supply and fix Thermostat switch for Deep freezer
Supply and fix Relay and OLP for deep freezer
Material and Labour for Charging of refrigerant R-134A including leak detection,welding and testing the same in entire system, including replacing of defective liquid strainer and capillary tube for following device complete.
For Water Cooler
For Refrigerator
For Deep Freezer
PSK Enterprises (BID ID -3381308)
m/s SRI VALLI ENTERPRISES (BID ID -3381173)
C SRINIVASAN (BID ID -3379498)
RK ENTERPRISES (BID ID -3381478)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .