Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹22.4 L+₹4.4 L (24.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | L3₹23.5 L+₹5.5 L (30.3%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L3 | Rejected-Finance Rejected being other than L1 | |
| 4 | L4₹24.3 L+₹6.3 L (34.8%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L4 | Rejected-Finance Rejected being other than L1 | |
| 5 | L5₹25.8 L+₹7.8 L (43.4%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L5 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
6 May 2021, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT OF FILTERS V BELTS AND SERVICING OF DG SETS AT SECTOR C AND D UNDER GE 865 EWS
2021_MES_434792_1
865/EWS(NIT-04)/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹72,000
Yes
24 May 2021
6 Apr 2021
8 May 2021
6 Apr 2021
6 May 2021
22 Apr 2021
Amount
Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engg-in-Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following cap DG sets NOTE (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (4) Make of spare recommendation by auth service centre of manufacturer
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
M & L for changing /toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed Make:-Veedol/Valvolin/ Castrol/Servo
S&F in replacement of Oil filter element as per existing for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Mico/TVS
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of Air cleaner element (inner and outer) suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of Fuel filter elements(primary & secondary) for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets make: Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of Dynamo Assy for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
140 KVA DG Set
S&F in replacement of auotmatic voltage regulator(AVR) 240 volt suitable for following capacity of DG Set. Cat Part No F680902000 Make -Kirloskar
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
S&F in replacement of self starter for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
500 KVA DG Sets
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of water pump assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
140 KVA DG Set
S&F in replacement of Turbo charger assy.for following capacity DG sets make cummins complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
S&F in replacement of Fan Hub assembely for following capacity DG set make cummins/Kirloskar/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
M&L for disconnecting the U/S DC alternator of following capacity DG Set, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engr-in-Charge.
380 KVA DG Set
200 KVA DG Set
M&L for taking out burnt winding of exciter of following capaicity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed by Engr-in-Charge.
380 KVA DG Set
200 KVA DG Set
For item Sr. No 14 and 15 here in above -: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
S&F in replacement of lub oil pump suitable for following Capacity DG Sets,make :Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
200 KVA DG Set
140 KVA DG Set
S&F in replacement of thermostate valve suitable for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of Oil seal front and rear suitable side for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging. Make- Exide/Amron.all as specified and directed by Engr-in-Charge
M &L for Removing the fuel injection pump (FIP) & injectors from following capacity of DG sets and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note : Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assemble by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
200 KVA DG Set
160 KVA DG Set
140 KVA DG Set
110 KVA DG Set
S&F in replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed
S&F in replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as directed
Taking down old rusted unserviceable silencer single/double with exhaust pipe and M&L for new silencer with Exhaust pipe complete bends, coupling etc suitable for following capacity of DG set including fixing arrangements and painting with silver paint and insulating with suitable size and length of asbestos rope complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 200 AMP, TPN Havells cat part No : IHCFFE0200 or equivalent of Legrand/ABB/Schneider/ L&T complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 320 AMP, TPN Havells cat part No : IHCFFE0320 or equivalent of Legrand/ABB/Schneider/ L&T complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 400 AMP, TPN Havells cat part No : IHCFFE0400 or equivalent of Legrand/ABB/Schneider/ L&T complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Air pipe (Turbo to Radiator) for any capacity of DG Set
S&F in replacement of battery charging alternator (12 volt) with 2 wire system for any capacity of DG Set
S&F in replacement of Digital RPM meter with Hour meter for any capacity of DG Set Make : ABB/HPL/L & T/AE/IMP/Automatic Electrical/ Premier/ LMP/ Meco/Bentec Electrical
S&F in replacement Digital Ammeter (0-800 Amp) capacity Make : ABB/HPL/L & T/AE/IMP/Automatic Electrical/ Premier/ LMP/ Meco/Bentec Electrical
S&F in replacement Digital Voltmeter (0-500 Volt) capacity Make : ABB/HPL/L & T/AE/IMP/Automatic Electrical/ Premier/ LMP/ Meco/Bentec Electrical
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 630 sqmm 3.5 core complete all as specified and as directed. Make : Cable Corporation of India/Finolex Cable Co/Polycab/GlosterHavells/KEI/ RR Kabel
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 500 sqmm 3.5 core Make : Cable Corporation of India/Finolex Cable Co/Polycab/GlosterHavells/KEI/ RR Kabel
S&F in replacement Stainless steel, Grey colour anti-vibration support pads for isolating the DG Set engine and alternator from the mounting frame having weighing capacity upto 400 Kgs each for suitable capacity of DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement of battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
S&F in replacement battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
Supply & toping up of best quality anti freezing,Inhabitor Corrosion (Coolant ) liquid for DG set at varrious capacity and locations complete all as specified and directed. Make-Castrol/Veedol/Valoline
M & L for changing /toping up of best quality of engine oil 15W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed Make:-Castrol/Veedol/Valoline
Note :- Makes of spare parts to be replaced under this work and mentioend in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of DG sets and other equipments.
KONCHOK TSEWANG
M/S BETONG CONSTRUCTION CO
Horizon Construction Company
R B TRADERS
Feroz Engineering Works
PADMA ENTERPRISES
Hitech Erectors Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .