| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.3 LAccepted-AOC CHENNAI | CHENNAI | TAMIL NADU | L1 | Accepted-AOC The lowest and negotiated tenderer | |
| 2 | L2₹69.6 L+₹30,045.27 (0.43%)Rejected-AOC NO 82 72 SANNATHI STREET THIRUVOTHUR CHEYYAR TOWN THIRUVOTHUR CHEYYAR TALUK 604 407 | RANIPET | TAMIL NADU | 604407 | L2 | Rejected-AOC High rate tenderer | |
| 3 | L3₹73.2 L+₹3.8 L (5.49%)Rejected-AOC NO 462 SATHIYAMOORTHI STREET CHEYYAR 604 407 THIRUVANNAMALAI DISTRICT | RANIPET | TAMIL NADU | 604407 | L3 | Rejected-AOC High rate tenderer |
Tender Value
Refer Docs
EMD Value
₹51,500
Closing Date
23 Feb 2024, 6:00 pmClosed
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Special repair works to existing 3 Nos. of Ins, 6 Nos. of SI and 86 Nos. of PC/HC Police Quarters at Pattabiram in Chennai city
2024_TNPHC_424491_1
SE/CC/DB/237/2024
Open Tender
Civil Works
Lump-sum
120 days
Pattabiram in Chennai city
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹51,500
11 Mar 2024
14 Feb 2024
26 Feb 2024
14 Feb 2024
23 Feb 2024
14 Feb 2024
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 m.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 m.
b) 2 to 3m depth
2.6) Supply and filling of 40 mm HBSJ
2.7) Supply and filling of 20 mm HBSJ
13.1) Filling with Excavated Earth
24) Manufacturing & supply of steel windows (Weight basis)
41) Painting - New "iron work"
47) Supplying and fixing of Alu Towel rail 75 cm long
51) Supplying and fixing of Water tank 700 litre capacity
52) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 a. 25mm dia
c.20 mm Dia
52.1) G.I Pipe 20mm dia for Hot water line (Fully Concealed in walls)
61.2) Supplying and laying and loose jointing the following dia stone ware pipes with ISI mark Superior variety (glazed) b)150mm dia SW pipe
78) Earthing Station IS3043 (Type I)
Annexure 1.5) Earth work excavation for Open foundation (excluding refilling) c) 3 to 4m depth
2.15) Supplying and filling stone dust
3.1.3) C.C.1:5:10 for Foundation & Basement
3.2.3) P.C.C. 1:2:4 for Foundation & Basement and other similar works
6.2.2) Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")
8.2.3.2) Standardised concrete Mix M20 Grade Concrete a. In Foundation and basement
10.2.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) d). In Second floor
16.6) Precast Jally ventilator 50mm tk.using standardised concrete mix M20 without vibrating charges a. In Ground Floor
b) In First Floor
18.1) Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raft beam, Raft slab etc.,
b. Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
21.5.2.2) Supply and Fixing Solid UPVC door Shutter with frame
23.2.1) Supplying and fixing of 4mm thick pin headed glass panels
28.1) Floor plastering in C.M. 1:4, 20 mm tk.
29.9.1) Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler). CM 1:3 20mm thick
32.1.1) Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick
32.1.2) Pointing the Pressed Tile over the roof with cement mortar 1:3
33.2.1) Plastering in C.M. 1:5, 12 mm thick
34.2.1) Plastering with CM 1:4 12mm thick
43.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.6) Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark confirming to IS 13952:1992- type 'A' for Rain water down fall pipe
50.6.1) Precast slab 50 mm tk.in C.C. 1:3:6 with fibre
51.8) Supplying and fixing of PVC water tank Lid
51.9) Supplying and fixing of Water tank nipple
52) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 d. 50mm dia Astm D schedule 40 threaded PVC pipe with necessary PVC/GI specials
54.1.1) Supplying and fixing of of 15mm dia half turn CP long body tap
54.2.1) Supplying and fixing of of 15mm dia half turn CP short body tap
56.3.1) S & F of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - in G.F.
56.4.1) Supply and fixing of of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap- Other than G.F.
57.1.1) Supply and fixing of of E.W.C.(White) 500 mm with PVC SWR grade "P" or "S" Trap
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B' a. 110 mm dia.
b. 75 mm dia.
58.5) PVC(SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl
59.2.1) Gully Trap using chamber burnt bricks of size 23x11.4x7.5cm
60.1) PVC Nahani trap (4way/2way)
61.3) UPVC Non Pressure pipe of SN8 SDR 34 ( S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
64.1.1) Wiring with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 K.V. grade cable 5 amps flush type switch [Open Wiring] a) Light point With Ceiling Rose
70.5.2) Supply and fixing of 4' long 18 W Crystal Glass LED tube Light with fitting
77.7.1) Run off mains with 2 wires of 2.5 Sqmm copper PVC insulated unsheathed single core 1.1KV cable(Open Wiring)
82.3.1)Supply and fixing of LED Street lighting luminaries suitable for fixing 30 watts LED lamp
93.1) Plastering with CM 1:3, 12mm with WPC
171.2.9) Supply and Delivery of Three phase Openwell Submersible motor Pumpset 50 LPM X 40m head
207.4.1.1) Painting the old walls with two coats of approved best exterior Emulsion paint in addition to one coat of approved primer paint including thorough scrapping
207.6) Painting the old iron work with two coats of ready mixed first class synthetic enamel paint including thorough scrapping the old paint
209.5.1) Clean removal of the old cement plastering both inside and outside from the existing walls of brick masonry
212.1) Dismantling the damaged Plain cement concrete in all floors
213) Dismantling the damaged brick works of cement mortar in all floors without affecting the adjacent structures
213.1) Supplying and fixing of SRFC cover slab a.60cm x 60cm
214.4) Labour charges for removing the 700 litres HDPE Water Tank
216) Dismantling the existing pressed tiles and weathering course without affecting the structure
221.1) Removing the damaged broken Steel window /ventilators
224.1) Dismantling the existing damaged RCC with out affecting the adjacent structures,
235.3.1) Attending the Crack by cutting the cracks for 3 to 5mm width and applying crack filler
254.1) Two legged scaffolding using 15cm dia casurna props upto 8 m ht
255.2) Supplying and fixing of LED Bulb for suitable for fixing it to pendent / bakelite battern holder b) 12 watts LED bulb
255.6) Supply and fixing of Bulk Head fitting suitable for 12W LED Bulb
451.3.2) Supplying and fixing of best approved quality of following CP water supply/Sanitary fittings a) CP two Way bib cock with health faucet
615.1) Supply and delivery of centrifugal Monobloc pumpset as per is 9079/2002 without panel board three phase 50 lpm x35m
615.2) Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/ Monoblock) in bore well/Open well Upto 3 HP
615.2.1)Labour charges for the erection of submersible pumpset in borewell/openwell a) Upto 5HP
619.2) Supplying and fixing of GM gate valves ISI mark a.50mm GM Gate valves
619.2.1) Supplying and fixing of following dia GM Non return Valve a.50mm dia GM Non-Return valve
619.5) Supplying and fixing of following dia GM Wheel Valve (Heavy duty) a.50mm dia GM Wheel Valve
Mughil Construction
R.SURESH BABU
Bidder Name
R.SURESH BABU
Mughil Construction
K.Saravanan
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_504661.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .