Loading…
Loading…
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Sept 2026, 6:00 pm
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIRS / REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBs, DBs, LIGHTS, SUMMER AND WINTER APPLIANCES INCL ATTENDING DAY TO DAY PETTY COMPLAINTS AT OTM ACCN 35 INF BDE, 16 KUMAON, 18 JAK RIF AND OTHER OTM LOCATIONS UNDER AGE E/M
2026_MES_784684_1
GE/TOKEN-45/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹40,000
Yes
17 Aug 2026
17 Aug 2026
9 Sept 2026
17 Aug 2026
7 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | (iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge.
(v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account.QSupply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. e"0.95, IP2 | - | - | - | - |
| 2 | icate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy e"120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. èS&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed.£S&F in repair of sheet metal enclosures for DBs when MCBs to be used SPN-8 Way, 240V with busbar as per site requirement complete all as specified and as directed.ZS&F switch piano flush type 5/6 Amps SP two way complete all as specified and as directed.oS&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and as directed.\S&F switch piano flush type 15/16 Amps SP one way complete all as specified and as directed.~S&F universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type complete all as specified and as directed.
Per point ïS&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 12 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed.`S&F in repair 12 watt LED Recessed/ surface Down lighter (Round/ square/Rectangular) SMD type Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.e"0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy e"120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.²S&F in repair of PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring complete all as specified and as directed.ZS& F Switch modular type,1 module 6 Amp one way complete all as specified and as directed.SS& F Switch modular type,1 module 16 Amp complete all as specified and as directed.dS& F in repair Switch modular type,1 module 6 Amp one way complete all as specified and as directed.VS&F in repair bell push, flush type 5/6 Amp complete all as specified and as directed.ZS&F in repair ceiling fan capacitor of 2.5 mfd complete all as specified and as directed. [S&F in repair ceiling fan capacitor of 3.15 mfd complete all as specified and as directed. S&F in repair 12 Watt LED bulb having B-22 Cap, AC 230 V 50Hz suitable for batten holder/bulkhead complete all as specified and as directed.
dS&F in repair switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.yS&F in repair socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and as directed.fS&F in repair switch piano flush type 15/16 Amps SP one way complete all as specified and as directed.S&F in repair universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type complete all as specified and as directed.\S&F in repair plug top, 16 Amps, 230 Volts, 50 Hz complete all as specified and as directed.óS&F in repair of MCCB 125 Amps 3 pole 415 volts fixed type with breaking capacity 25 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc.complete all as specified and as directed.ÉS&F in repair of MCB SPN 40 Amp 240 Volt, 10 KA 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed.ÉS&F in repair of MCB SPN 63 Amp 240 Volt, 10 KA 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed.~S&F in repair switch socket combination 6 Amp with gang box complete as per sample complete all as specified and as directed.S&F in repair switch socket combination 16 Amp with gang box complete as per sample complete all as specified and as directed.S&F in repair fan regulator 120 W modular type electronic, stepped type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.S&F in repair 0-4, stepped type, electronic regulator suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.ZS&F switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.LS&F bell push, flush type 5/6 Amp complete all as specified and as directed.S&F 0-4, stepped type, electronic regulator suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.OS&F electric bell ding dong any type complete all as specified and as directed.\S& F Socket modular type,2 module, 2/3 pin, 6 Amp complete all as specified and as directed.VS& F Socket modular type,2 module, 6/16 Amp complete all as specified and as directed.RS&F in bell push, modular type 5/6 Amp complete all as specified and as directed.aS&F Electronic fan regulator, modular type 2M, 4 steps complete all as specified and as directed.ÊS&F in repair of MCB TPN 100 Amp 240 Volt, 10 KA 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed.OS & F modular AC Box with MCB 20 Amp complete all as specified and as directed.FS&F in repair modular AC box with MCB 20 Amp complete with metal box and 3 Pin top plug complete all as specified and as directed.
Note : Rates are inclusive of cutting/chases for mounting metal box on wall and making good the disturbed surfaces with OBD/Colour wash/ white wash and wall care putty etc, where ever required.ºM & L for sub main wiring using PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 10 Sqmm for Phase and neutral and 1 run of 10 Sqmm for earth wire drawn through existing PVC/MS conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement and complete all as specified and as directed.
Notes : (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour.
(b) Two runs of main cable and one run of earth cable all together shall be considered as one length.
(c) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.ÄËgS& F in repair Socket modular type, 2 module, 2/3 pin, 6 Amp complete all as specified and as directed.]S& F in repair Switch modular type,1 module 16 Amp complete all as specified and as directed.S& F in repair Socket modular type, 2 module, 2/3 pin combined shuttered type 16 Amp complete all as specified and as directed.dS&F in repair switch piano flush type 5/6 Amps SP two way complete all as specified and as directed.yS&F in replacement ceiling fan complete with blades,down rod , remote and all accessories, 230V, 1200MM sweep min air delivery 210 CFM with service valve 5.00 BEE. Five star rated coper winding with brushless direct current motor(BLDC) including taking down old ceiling fan complete all as specified and as directed.
Note:-Taking down old ceiling fan and deposite to MES Yard.>BÄS&F in replacement of steel body exhaust fan 300 mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with complete all as specified and directed.
Note:-Taking down old exhaust fan and deposite to MES Yard.ÌSupply and fixing in repair 1200mm sweep BLDC fan controller PCB with short circuit protection power 240V suitable for BLDC ceiling fan of existing make at site complete all as specified and as directed.Supply and fixing in repair frame of exhaust/fresh air fans of 230/300 mm sweep heavy duty complete all as specified and as directed.~Supply and fixing in repair frame of wall mounted fans of 450 mm sweep heavy duty complete all as specified and as directed.Supply and fixing in repair upper and lower Gun metal bush for ceiling fans as per existing complete all as specified and as directed.Supply and fixing in repair Canopy (set of 2) for Ceiling fans of 1200/1400mm swipe heavy duty complete all as specified and as directed.Supply and fixing in repair ball bearing for ceiling fan of suitable size & model as per existing complete all as specified and as directed.Supply and fixing in repair 'U' clamp with rubber real for hanging ceiling fans of 1200/1400 mm sweep as per sample complete all as specified and as directed.ÍSupply and fixing in repair down rod of 1.5 feet height fabricated out of MS pipe 12mm dia heavy duty, duly painted with one coat of white synthetic enamel paint complete all as specified and as directed.Supply and fixing in repair blade (set of 3 blades) of Ceiling fans 1200/1400mm sweep heavy duty as per existing complete all as specified and as directed.Supply and fixing in repair blade (set of 3/4 blades) of wall mounted fans of 450 mm sweep heavy duty complete all as specified and as directed.Supply and fixing in repair safety plug and nut for high pressure release as per existing complete all as specified and as directed.¦Supply and fixing in repair Rubber gasket for Water heater storage of any capacity fixed and suitable as per the existing, complete all as specified and as directed. hSupply and fixing in repair in PRCD 16 AMP, 30 mA plug Top , complete all as specified and as directed.ïSupply and fixing in repair MS top & bottom cover for geysers of 25 ltrs capacity any make as per sample duly painted with two coats of synthetic enamel spray paint (first quality) as per existing complete all as specified and as directed.¹Supply and fixing in repair MS outer cover for geyser made out of MS sheet suitable for upto 50 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed. Supply and fixing in repair indicating lamp round/flat type (Red & Green) 230 volts suitable for Geyser as per sample complete all as specified and as directed.Supply and fixing in repair non return valves 15mm dia made up of brass as per existing complete all as specified and as directed.Supply and fixing in repair thermostat 9/11" (ISI Marked) for 25/35/50 Litres capacity geyser as per sample complete all as specified and as directed.²Supply and fixing in repair PVC connection 15 mm x 600 mm for Hot & Cold water with brass nuts and washers at both ends as per existing complete all as specified and as directed.ÌM&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal having thickness 1.2mm boxes of required size and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed.
Note:- The rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.·M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes with modular steel terminal boxes having thickness 1.2mm including white cover modular plate with frame suitable for modular switch, socket etc screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed.
Note:- The rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.ëïName of Work: MAINT AND REPAIRS / REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBs, DBs, LIGHTS, SUMMER AND WINTER APPLIANCES INCL ATTENDING DAY TO DAY PETTY COMPLAINTS AT OTM ACCN 35 INF BDE, 16 KUMAON, 18 JAK RIF AND OTHER OTM LOCATIONS UNDER AGE E/M OF GE (SOUTH) DELHI CANTT.ËS&F in repair PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. ÌS&F in repair PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. ÍS&F in repair PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed. ÆS&F in repair PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed.ÆS&F in repair PVC insulated FRLS 2 core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed complete all as specified and as directed.£S&F in repair single phase motor AC 230V, 1500 RPM copper wounded suitable for fresh air fan 450mm sweep as per existing complete all as specified and as directed.&S&F in repair 30 watt Building security light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.e"0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy e"120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90C), complete all as specified and as directed.>S&F in repair of GI pipe's bracket suitable for fixing of bldg security LED light fitting of 45 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and as directed.
Note :- GI pipe should be 25 mm bore with medium grade and the same to be moulded in 45 degree angle at the 1m height to fix the building security light fitting.¡ÄS&F in replacement of steel body exhaust fan 450 mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with complete all as specified and directed.
Note:-Taking down old exhaust fan and deposite to MES Yard.*Supply and fix in repair LED garden light (Bollard) light fitting luminiaries of 8/9 D71W in Round Shape with 1 Mtr height of 3000K with IP 65, 70 Lm/watt, PF >0.90 complte with all accessories including necessary connection with suitable of copper cable connection all as specified and directed. Supply and fixing in repair frame of Fan/Fresh air fans of 450 mm sweep heavy duty complete all as specified and as directed.[M&L for Fabrication of aluminium frame opening cover suitable for exhaust fan 300 mm sweep opening with wiremesh sliding window including opening of hole through out the wall as suitable for exhaust fan of size 300 mm sweep and fixing of nut-bolts with 4" anchor fastner of suitable size and making good the disturbed surface and all as per site requirement complete all as specified and as directed.
Notes : (i) The quoted rates are inclusive for making hole opening civil work with MS fastner bolt of 8mm dia and 100 mm (minimum) long for fixing of exhaust fan and MS fastner clamps strip 38 mm wide and 5 mm thick (min) to hold exhaust fan.
(ii) Staircase/scaffolding arrangement for fixing of frame with wiremesh sliding window up to third floor shall be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Supply and fix in repair 36 W LED Recess mounting 2'x2' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo rLED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed.
Supply and fix in repair 36 W LED Recess mounting 4'x1' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240 | 750 | Each | - | - |
| 3 | 䄠灯牥瑥楡杮嘠汯慴敧删湡敧漠㐱ⴰ㜲嘰䴠湩畩湉整湲污匠牵敧倠潲整瑣潩″癋偉㈠‰䥂⁓散瑲晩捩瑡潩摩敲畱物摥映䱲䑅䐠楲敶…楌業慮物䕏⁍桳畯摬栠癡湩栠畯敳丠䉁⁌捁牣摥慩整♒⁄湡睯界業楮牡慭畮慦瑣牵湩慦楣楬祴琠牰癯摩䵌㜠‹敲潰瑲椠潨獵䅎䱂愠捣敲楤整慬…䵌〸爠灥牯⁴獩畳摥戠⁹䕌⁄慭畮慦瑣牵牥挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整ਠQ䄀汬愠数牓瑩浥丠㤵〮‰敨敲椭敢潦敲畢⁴硥慨獵⁴慦景㈠〳㌯〰洠睳敥M䄀汬愠数牓瑩浥丠㤵〮‰敨敲椭敢潦敲畢⁴硥慨獵⁴慦景㐠〵洠睳敥N䄀汬愠数牓瑩浥丠㤵〮‰敨敲椭敢潦敲慷汬洠畯瑮摥映湡漠㔴‰浭猠敷灥밮汁獡瀠牥椠整潎㤠⸳〰栠牥ⵥ湩戭晥牯畢⁴湯″楰潳正瑥漠瑵敬ⱴ㔠㘯䄠灭ⱳ椠摮灥湥敤瑮楷桴挠扡敬ㄠ㔮匠浱畳瑩扡敬挠湯散污摥倠䍖䴯⁓潣摮極⁴潣灭敬整愠汬愠灳捥晩敩湡獡搠物捥整z䄀汬愠数瑩浥丠㌹〮‰敨敲椭敢潦敲戠瑵㔠㘯䄠灭猠捯敫⁴畯汴瑥漠慳敭戠慯摲挠浯汰瑥污獡猠数楣楦摥愠摮愠楤敲瑣摥汁獡瀠牥椠整潎㤮⸳〰栠牥ⵥ湩戭晥牯畢⁴潦湯潳正瑥漠瑵敬⁴㔱䄠灭湯椠摮灥湥敤瑮戠慯摲眠瑩慣汢⸲‵煓浭猠穩潦桰獡湡敮瑵慲湡⸲‵煓浭映牯攠牡桴湩楷 | 150 | Each | - | - |
| 6 | h through existing PVC/MS conduit complete all as specified and as directed.ïAll as per item No 93.00 here-in-before but for one light controlled by 2 Way switch using cable 1.5 Sqmm size for phase and neutral and 1.5 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.½All as per item No 106.00 here-in-before but one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm suitable concealed PVC/MS conduit complete all as specified and as directed.{All as per item No.106.00 here-in-before but 5/6 Amp socket outlet on same board complete all as specified and as directed.øAll as per item No.106.00 here-in-before but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.ôAll as per item No.106.00 here-in-before but for one socket outlet 15 Amps on independent board with cable 4 Sqmm size for phase and neutral and 4 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed."Contract No: GE/TOKEN-45/2026-27 ÞM&L for comprehensive maint of regular induction type ceiling fan, exhaust fan of Md accn including proper checking of base connection, lock pin of U clamp fan blade, serviceability of down rod, gun metal bush, shaft, stater, ring, ceiling fan outer body, exhaust/ceiling fan blade and body where ever required complete with greasing/lubrication and cleaning of fan bearing complete all as specified and as directed.
Note :- 1. All material required/spare parts shall be measured and paid separately under respective item of BoQ.
2. The rated quoted by the contractor deemed to be including taking down of ceiling fan/exhaust fan, transportation to workshop for rewinding or machining work, and refixing the same after repair. ¦ªSupply and fixing in repair blade of exhaust/fresh air fans of 230/300 mm swipe heavy duty as per sample complete all as specified and as directed.Supply and fixing in repair blade (set of 3/4 blades) of exhaust/fresh air fans of 450 mm sweep heavy duty complete all as specified and as directed.Taking down carefully storage type water heater (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connection etc cleaning of the body inlet/outlet/vent pipes, stop valve, non return valves etc leakage arresting of inner copper/steel tank by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washers etc, refixing the same in position by replacing mounting bolts and nuts reconnecting alll inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning for geyser of capacity 25 liter capacity complete all as directed by Engr-in-charge.
Notes : (i) All material /spare part i.e. Non return valve, PVC connection /Copper connections cable , glass wool , element, thermostat , storage tank, indicator etc shall be measured separately.
(ii) The rate quoted by the contractor deemed to be including taking down of geyser and refixing the same after repair.ns¢Supply and fixing in repair heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.ÿSupply and fixing in repair storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) or as per sample for 25 litre capacity geysers with collar, duly tested at required pressurecomplete all as specified and directed.Supply and fixing in repair MS base plate assembly 20 SWG heavy duty suitable for 25 to 50 litre capacity geyser with complete inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site As per sample complete all as specified and directed. | 20 | Each | - | - |
| 22 | S&F in repairs rigid PVC conduit 20 mm dia including accessories tees, bends, reducer, cooption, riddles etc complete all as specified and directed. | 60 | RM | - | - |
| 23 | S&F in repair electric bell ding dong any type complete all as specified and as directed. | 50 | Each | - | - |
| 30 | S&F in repairs sheet metal enclosure V TPN 4 way Double door DB, IP-54 bus bar neutral link earth bar and din rail with gasket etc. complete all as specified and as directed. | 5 | Each | - | - |
| 32 | S&F in repair of sheet metal enclosures for DBs when MCBs to be used SPN-12 Way, 240V with busbar as per site requirement complete all as specified and as directed. | 4 | Each | - | - |
| 34 | S&F in repair of MCB SP 6 to 32 Amp 240 Volts, 10 KA, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed. | 150 | Each | - | - |
| 38 | S&F in repair plastic laminated sheet top cover 3 mm thick of size 8"x5" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed. | 10 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
TenderpagesT45.pdf
Tender Documents • 0.91 MB
SoCT45.pdf
Additional Documents • 0.38 MB
BOQ_879266.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].