Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.4 L+₹39,414 (2.07%)Rejected-Finance | L2 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | M/S HINA ELECTRICALS L2 | M/S WASEEM KHAN CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down Maintenance complete overhauling of 11 KV VCB of existing make/ type/mode/capacityl including disassembling of operating mechanism parts well cleaning with petrol and CRC-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete panel board,main busbar,decarbonizing all joints busbar CTS,PTS, spouts metal parts and making VCB perfect operating in manual and electric mode and calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented inservice by primary current injection method to ensure proper function of trip coil control circuit etc. during fault condition setting by expert complete all as specified and directed.Note:- Spare parts required to make VCB functional will be measured and paid separately under respective items. | 8 | Each Job | 40,000 ₹3,20,000 | 2,000 ₹16,000 Lowest |
| 1.01 | (a) S&F in replacement Current transformer (CT) of ratio 100-50/5-5, IL 12/28/75/KVP STC 13-1KA for 1 second confirming to IS-2705, IEC-60044 complete all as specified and as directed. | 2 | Set of three | 100 ₹200 Lowest | 8,000 ₹16,000 |
| 1.02 | (b) Replacement of 11 KV HT PT housing spout (Male/Female) complete all as specified and directed by Engr- in - Charge. | 3 | Each Job | 100 ₹300 Lowest | 8,000 ₹24,000 |
| 1.03 | (c) Replacement of bearing of 11 KV complete all as specified and directed. | 4 | Each Job | 100 ₹400 Lowest | 600 ₹2,400 |
| 1.04 | (d) S&F in replacement of unsv 3 phase over current, earth fault relay of CT rating 1A to 5A model MC-31A, Aux supply volt-20-110 volt AC/DC out put.complete all as specified and as directed. | 2 | Each Job | 16,000 ₹32,000 | 8,000 ₹16,000 Lowest |
| 1.05 | (e) Taking down existing unserviceable voltmeter and S&F new degital Volt meter suitable measuring 11000 volt with built in selector switch suitable for mounting on HT VCB complete all as specified and as directed. | 2 | Each | 100 ₹200 Lowest | 2,000 ₹4,000 |
| 2.00 | Testing of dielectric strength of transformer's oil installed at various locations by taking samples of oil from transformers for testing in the laborotary and submit detailed report of electrical parameters of oil testing complete all as directed. Note : Testing charges shall be born by the Contractor. | 24 | Each Job | 10 ₹240 Lowest | 300 ₹7,200 |
| 3.00 | M&L for dehydration of Existing transformer oil/Servo stabilizer oil with mobile transformer filteration plant at site with all required accessories connected to transformer and carrying out filteration of transformer oil for the desired dielectric strength. ie not less than 60 KV at 2.5 mm gap all as directed by Engineer-in-Charge. Note : Test certificate shall be submitted before and after filteration for dielectric strength. | 4,000 | Ltrs | 40 ₹1,60,000 Lowest | 100 ₹4,00,000 |
| 4.00 | Supply & filling for topping up new transformer oil in the transformer after dehydration with dehydration machine to achieve dielectric strengh of oil 60 KV at 2.5 mm gap complte all as specified and directed. . | 1,800 | Ltrs | 160 ₹2,88,000 | 25 ₹45,000 Lowest |
| 5.00 | M & L for Servicing of existing transformer after disconnecting of all incoming and outgoing electrical connections including opening of cover and tightening of all bushes and studs of transformer and top up of transformer oil including replacement of defective/unserviceable part and reconnection of all incoming and outgoing electrical connections complete for 50 to 400 KVA capacity transformer. Note:- Oil and spare part as reqd shall be measured and paid separately. | 15 | Each Job | 500 ₹7,500 Lowest | 1,200 ₹18,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 Sept 2025, 6:00 pmClosed
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (E)/67 OF 2025- 2026REPAIR/REPLACEMENT AND MAINT OF EXTERNAL ELECTRIFICATION, REPAIR OF TRANSFORMER ALONGWITH ALLIED SERVICES FOR HT DISTRIBUTION SYSTEM AT MIL STATION SHAJAHANPUR UNDER GE (EAST) BAREILLY
2025_MES_728964_1
8200/B/883/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Shajahanpur
As per NIT
7 documents required · 7 mandatory
₹500
GE (East) Bareilly
₹50,000
Yes
5 Dec 2025
2 Sept 2025
7 Oct 2025
2 Sept 2025
30 Sept 2025
16 Sept 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .