Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC Being Lowest Bidder. | |
| 2 | L2₹5.7 L+₹1.2 L (26.5%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | L2 | Rejected-Finance Not Being Lowest Bidder. | |
| 3 | L3₹6.0 L+₹1.6 L (34.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder. | |
| 4 | Rejected-Technical 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | - | Rejected-Technical Not meeting NIT criteria |
Tender Value
₹5.3 L
Closing Date
12 Jul 2021, 11:00 amClosed
JGM(E-E)-II
AAI, Operational Offices, Chennai Airport, Chennai-600016.
SITC of UPS and allied Electrical Works in Ceremony lounge at Chennai International Airport
2021_AAI_80543_1
AAI/CHE/AMED-IX/UPS/2021-22/1
Open Tender
Electrical Works
Item Rate
60 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,120
Exempted
25 Aug 2021
26 Jun 2021
13 Jul 2021
28 Jun 2021
12 Jul 2021
28 Jun 2021
28 Jun 2021 - 8 Jul 2021
Amount
SITC of 10KVA, 3Ph-3Ph IGBT based double conversion online UPS system with 12V 65Ah - 20 Nos SMF batteries for backup and with battery rack, etc compatible with DG Set & confirming to tender technical Specification. UPS OEM must have authorised service center at chennai.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted,inclusive of 100 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (TPN 4 (8+12) Way MCB DB double door)
Supplying of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (SPN 8 Way MCB DB double door)
Supplying and fixing following rating, 415 volts, MCB, C curve, 10KA in the existing MCB DB complete with connections, testing and commissioning etc., as required
20A FP MCB
16A TP MCB
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, "C" curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, "C" curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supply of Copper Conductor, XLPE insulated, PVC sheathed, armoured power cable of 1.1 KV grade of following Sizes conforming to IS 7098 (Part-1) as amended upto date as required. 4core 4 sqmm
Supply and Installation of 63A 4P ON Load Change Over switch operating on 3-PHASE, 415volt, 50HZ, with enclosure etc. as required.
Laying of 4 core 4 sqmm Copper armoured cable over existing false ceiling in cermony lounge with ceiling supports where ever possible;Including cutting of the false ceiling for entry and exit of the cable;carrying false ceiling work for the cut portion and any other portion damaged during laying of the cable, including applying putty and colour for the damaged false ceiling.
Laying of 4 core 4 sqmm Copper armoured cable in suitable dia 2mm thick PVC pipe and concealing the pipe in wall; including chipping the wall, plastering, applying putty and painting it matching with existing wall colour.
Installtion of SPN double door 8way DB by concealing it(flush mounting) in wall;including chipping the wall, plastering, applying putty and painting it matching with existing wall colour.
Removing the existing light point wiring from the existing DB and terminating the same in the newly installed SPN DB's adjacent to the existing DB'S. Routing of all the wires shall be through 2mm thick PVC PIPE of suitable dia concealed in wall;including chipping the wall, plastering, applying putty and painting it matching with existing wall colour.
Supplying and making end termination with brass compression gland and aluminium lugs for 4x4 sqmm of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.
DElite System Engineering (India) Pvt. Ltd.
SENTHIL ENGINEERING CONTRACTORS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .