Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 CrAccepted-AOC N A | ₹32.3 Cr Quoted ₹33.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹33.6 CrRejected-AOC D 2 3 RAJAT APARTMENT SENAPATI BAPAT ROAD SHIVAJI NAGAR PUNE 411016 | PUNE | MAHARASHTRA | 411016 | ₹33.6 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹34.0 CrRejected-AOC OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | ₹34.0 Cr | L3 | Rejected-AOC L3 |
| 4 | L4₹34.4 CrRejected-AOC DURGA APT INDRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | ₹34.4 Cr | L4 | Rejected-AOC L4 |
| 5 | L5₹34.7 CrRejected-AOC 309 10 SURESHWAR TECHNO IT PARK PREMISES CO OP SOC LTD NEW LINK ROAD BORIVALI WEST MUMBAI 400092 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400092 | ₹34.7 Cr | L5 | Rejected-AOC L5 |
Tender Value
₹31.1 Cr
EMD Value
₹15.5 L
Closing Date
30 Aug 2024, 6:15 pmClosed
E.E.P.W.Division No. 2 Solapur
E.E.P.W.Division No. 2 Solapur
CONSTRUCTION OF 30 BEDDED RURAL HOSPITAL AND RESIDENTIAL QUARTERS AT ANAGAR TAL MOHOL DIST SOLAPUR
2024_PWDRP_1071084_1
PWD_SOL2_NOTICE_11_2024_25
Open Tender
Civil Works - Buildings
1095 days
CONSTRUCTION OF 30 BEDDED RURAL HOSPITAL AND RESID
as per booklet
3 documents required · 3 mandatory
₹3,540
₹15.5 L
C.E.P.W.Region Pune
21 Oct 2024
16 Aug 2024
3 Sept 2024
16 Aug 2024
30 Aug 2024
16 Aug 2024
16 Aug 2024 - 20 Aug 2024
20 Aug 2024
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meter beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ra millimetering, watering including shoring and strutting etcetra complete. for all leads and lifts By Mechanical Means Hospital
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meter beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ra millimetering, watering including shoring and strutting etcetra complete. for all leads and lifts By Mechanical Means Residential Quarters
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ra millimetering, watering including shoring and strutting etcetra complete. for all leads and lifts By Mechanical Means Hospital
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ra millimetering, watering including shoring and strutting etcetra complete. for all leads and lifts By Mechanical Means Residential Quarters
Filling in plinth and floors with approved excavated material in 15centimeter to 20centimeter Layers including watering and compacting etcetra complete. Hospital
Filling in plinth and floors with approved excavated material in 15centimeter to 20centimeter Layers including watering and compacting etcetra complete. Residential Quarters
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centimeter to 20 centimeter including watering and compaction etcetra complete. Hospital
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centimeter to 20 centimeter including watering and compaction etcetra complete. Residential Quarters
Providing preconstructional antitermite treatment as per Indian Standars 6313(Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Hospital
Providing preconstructional antitermite treatment as per Indian Standars 6313(Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Residential Quarters
Providing preconstructional antitermite treatment as per Indian Standars 6313(Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Hospital
Providing preconstructional antitermite treatment as per Indian Standars 6313(Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Residential Quarters
Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15 centimeter to 20 centimeter thick including hand packing and compacting etcetra complete. Hospital
Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15 centimeter to 20 centimeter thick including hand packing and compacting etcetra complete. Residential Quarters
Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15 centimeter to 20 centimeter thick including hand packing and compacting etcetra complete. CC Drain
Providing and laying in situ/ready mix/ready mix Mix 15 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etcetra complete.(with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled with concrete batch mix plant(pan mixer) with natural/artifical sand) Hospital
Providing and laying in situ/ready mix/ready mix Mix 15 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etcetra complete.(with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled with concrete batch mix plant(pan mixer) with natural/artifical sand) Residential Quarters
Providing and laying in situ/ready mix/ready mix Mix 15 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etcetra complete.(with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled with concrete batch mix plant(pan mixer) with natural/artifical sand) CC Drain
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetra columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetra columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) First Floor Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) First Floor Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Second Floor Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Second Floor Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Third Floor Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) First Floor Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) First Floor Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Second Floor Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Second Floor Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Third Floor Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital First Floor
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters First Floor
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetra complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/quartzite/granite/gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C. meter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetra complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetra) with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital First Floor
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters First Floor
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Hospital Second Floor
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters Second Floor
Providing and laying Cast in situ/Ready Mixcement concrete Mix 30 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) Residential Quarters Third Floor
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Hospital
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Residential Quarters
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. CC Drain
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Hospital
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Residential Quarters
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Hospital
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Residential Quarters
Providing and fixing in position Thermo Mechanically Treated-FE-500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetra as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Residential Quarters
Providing fly ash brick masonry with conventional/Indian Standards type fly ash bricks in Cement mortar 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etcetra complete. Hospital
Providing fly ash brick masonry with conventional/Indian Standards type fly ash bricks in Cement mortar 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etcetra complete. Residential Quarters
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Hospital
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Residential Quarters
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Hospital First Floor
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Residential Quarters First Floor
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Hospital Second Floor
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Residential Quarters Second Floor
Providing fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetra Complete Residential Quarters Third Floor
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Hospital
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Residential Quarters
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Hospital First Floor
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Residential Quarters First Floor
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Hospital Second Floor
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Residential Quarters Second Floor
Providing Second class fly ash brick masonry with conventional/Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimeter diameter/two hoop iron strips 25 millimeter x 1.60 millimeter at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etcetra complete. Residential Quarters Third Floor
Providing and fixing 20 to 25 millimeter thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete(RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 millimeter depth, filling the joints with 6 millimeter size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/-with ponding test etcetra complete.(excluding Cement concrete 1:3:6 base concrete)
Providing and fixing 20 to 25 millimeter thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete(RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 millimeter depth, filling the joints with 6 millimeter size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/-with ponding test etcetra complete.(excluding Cement concrete 1:3:6 base concrete) Hospital
Providing and fixing 20 to 25 millimeter thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete(RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 millimeter depth, filling the joints with 6 millimeter size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/-with ponding test etcetra complete.(excluding Cement concrete 1:3:6 base concrete) Residential Quarters
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Hospital
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Residential Quarters
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Hospital First Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Residential Quarters First Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Hospital Second Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Residential Quarters Second Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 millimeter bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in centimeter 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 millimeter thick brick bedding in centimeter mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetra complete. Residential Quarters Third Floor
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Hospital
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Residential Quarters
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Hospital First Floor
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Residential Quarters First Floor
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Hospital Second Floor
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Residential Quarters Second Floor
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete. Residential Quarters Third Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Hospital
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Residential Quarters
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Hospital First Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Residential Quarters First Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Hospital Second Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Residential Quarters Second Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetra complete. Residential Quarters Third Floor
Providing and laying vitrified mirror/glossy finish tiles having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete Hospital
Providing and laying vitrified mirror/glossy finish tiles having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete Hospital First Floor
Providing and laying vitrified mirror/glossy finish tiles having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standards 15622-2006(group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetra complete Hospital Second Floor
Providing and laying vitrified matt finish tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etcetra complete.Hospital
Providing and laying vitrified matt finish tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etcetra complete. Hospital First Floor
Providing and laying vitrified matt finish tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming Indian Standards 15622-2006(Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etcetra complete. Hospital Second Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimeter x 30 centimeter and confirming to Indian Standars 15622-2006(Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetra complete. Hospital
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimeter x 30 centimeter and confirming to Indian Standars 15622-2006(Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetra complete. Hospital First Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimeter x 30 centimeter and confirming to Indian Standars 15622-2006(Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetra complete. Hospital Second Floor
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete.Hospital
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete. Residential Quarters
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete.Hospital First Floor
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete. Residential Quarters First Floor
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete.Hospital Second Floor
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete. Residential Quarters Second Floor
Providing and laying ceramic tiles having size 30 centimeter x 60centimeter confirming to corresponding Indian Standars for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etcetra complete. Residential Quarters Third Floor
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Hospital
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Residential Quarters
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Hospital First Floor
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Residential Quarters First Floor
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Hospital Second Floor
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Residential Quarters Second Floor
Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20 millimeter thick for door frame/dado/window boxing etcetra On Cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetra complete.Residential Quarters Third Floor
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete.Hospital
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete. Residential Quarters
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete.Hospital First Floor
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete. Residential Quarters First Floor
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete.Hospital Second Floor
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete. Residential Quarters Second Floor
Providing and fixing machine cut machine polished 18 millimeter to 20 millimeter thick telephone black/Amba White/Cat bary brown/RBI red/Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetra complete. Residential Quarters Third Floor
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 millimeter thickness of having a strength of 400 Kilogram/Square centimeter of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including skirting joints and cleaning etcetra complete.(using 100 percent crushed sand) Hospital
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Hospital
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Residential Quarters
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Hospital First Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Residential Quarters First Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Hospital Second Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Residential Quarters Second Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimeter thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimeter thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetra complete.Residential Quarters Third Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Hospital
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Residential Quarters
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Hospital First Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Residential Quarters First Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Hospital Second Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Residential Quarters Second Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90meter x 2.40meter with aluminium door frame of powder coated section 101.60 x 44.75 millimeter, 3.18 millimeter thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimeter x 44.5 millimeter x 3.00 millimeter thick top rails 47.62 x 44.45 millimeter x 3.00 millimeter thick, vertical style 47.62 x 44.45 millimeter, 3.00 millimeter thick and for shutter plain glass panes 5 millimeter thick for top panels and 12 millimeter thick both side laminated phenol bonded particle board panels for bottom panels etcetra, Indian StandarsI. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Polyvenylchloride gaskets, 250 millimeter length tower bolts, 150 millimeter dia meter pad handle, etcetra as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etcetra complete Residential Quarters Third Floor
Providing and fixing ISI marked double swing flush door shutters conforming to Indian Standards :2202(Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimeter thick including ISI marked Stainless Steel L-hinges with necessary screws Fittings & Fixtures per leaf SS kick plates on both sides of the door of 300 millimeter height Heavy Duty satin finish butt SS Hinges(100 millimeter x 75 millimeter x 3 millimeter in size)-4 nos. SS finished lever handle with mortise lock-1 number Floor spring-1 number 100 millimeter x 100 millimeter safety glass at the specified location Hospital
Providing and fixing ISI marked double swing flush door shutters conforming to Indian Standards :2202(Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimeter thick including ISI marked Stainless Steel L-hinges with necessary screws Fittings & Fixtures per leaf SS kick plates on both sides of the door of 300 millimeter height Heavy Duty satin finish butt SS Hinges(100 millimeter x 75 millimeter x 3 millimeter in size)-4 nos. SS finished lever handle with mortise lock-1 number Floor spring-1 number 100 millimeter x 100 millimeter safety glass at the specified location Hospital First Floor
Providing and fixing ISI marked double swing flush door shutters conforming to Indian Standards :2202(Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimeter thick including ISI marked Stainless Steel L-hinges with necessary screws Fittings & Fixtures per leaf SS kick plates on both sides of the door of 300 millimeter height Heavy Duty satin finish butt SS Hinges(100 millimeter x 75 millimeter x 3 millimeter in size)-4 nos. SS finished lever handle with mortise lock-1 number Floor spring-1 number 100 millimeter x 100 millimeter safety glass at the specified location Hospital Second Floor
b)Shutter : Supplying & Fixing of 55 millimeter thick asbestos free "TUFWUD" criteria checked-fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance-FD 120 as per Indian Standars:3614(part-II) comprising of 2x8 millimeter Calcium Silicate boards over Chemically treated(with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15 percent as per IS:1141) internal timber(Malaysian Hard Wood, densified to 810 Kilogram/cubic meter) frame work of 100x32 millimeter with 32 millimeter thick infill of ceramic fiber(density 128 Kilogram/cubic meter), vermaculite mix faced with 3 millimeter Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush-Type intumescent strip of size 10 millimeterx4 millimeter affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Hospital
b)Shutter : Supplying & Fixing of 55 millimeter thick asbestos free "TUFWUD" criteria checked-fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance-FD 120 as per Indian Standars:3614(part-II) comprising of 2x8 millimeter Calcium Silicate boards over Chemically treated(with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15 percent as per IS:1141) internal timber(Malaysian Hard Wood, densified to 810 Kilogram/cubic meter) frame work of 100x32 millimeter with 32 millimeter thick infill of ceramic fiber(density 128 Kilogram/cubic meter), vermaculite mix faced with 3 millimeter Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush-Type intumescent strip of size 10 millimeterx4 millimeter affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Hospital First Floor
b)Shutter : Supplying & Fixing of 55 millimeter thick asbestos free "TUFWUD" criteria checked-fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance-FD 120 as per Indian Standars:3614(part-II) comprising of 2x8 millimeter Calcium Silicate boards over Chemically treated(with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15 percent as per IS:1141) internal timber(Malaysian Hard Wood, densified to 810 Kilogram/cubic meter) frame work of 100x32 millimeter with 32 millimeter thick infill of ceramic fiber(density 128 Kilogram/cubic meter), vermaculite mix faced with 3 millimeter Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush-Type intumescent strip of size 10 millimeterx4 millimeter affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Hospital Second Floor
Providing and fixing of factory made uPolyvenylchloride Sliding window & door(White Colour) complete, comprising uPolyvenylchloride multi-chambered frame having in-built uPolyvenylchloride roller track on top and uPolyvenylchloride sash with wall thickness of 2.3 millimeter(+-0.2 millimeter), duly reinforced with Galvanised Iron section 1.5 millimeter, wherever required. uPolyvenylchloride window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256-more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/ millimeter2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/ millimeter2(b) For the compression bending test Shall not be < 30N/ millimeter2 6 Heat Reversion Test Indian Standars :4985-2000 Shall not be > 2.0 percent 7 Surface Spread of flame BS : 476-Part 7 Classification 1 8 Ignitability Evaluation BS : 476-Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 millimeter Float Annealed glass in the sash, uPolyvenylchloride glazing bead, interlock, EPDM/TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window/Door will be fixed to the wall with 100 millimeter long and 8 millimeter diameter Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPolyvenylchloride Window and Door Profiles are warranted for a period of ten(10) years against non-uniform discoloration, wrapping and rotting under general use. :: 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash(Each sash shall be half of width of window)(Big Series) Window frame of size 122 x 54 millimeter & Sash of size 64 x 47m meter Hospital
Providing and fixing of factory made uPolyvenylchloride Sliding window & door(White Colour) complete, comprising uPolyvenylchloride multi-chambered frame having in-built uPolyvenylchloride roller track on top and uPolyvenylchloride sash with wall thickness of 2.3 millimeter(+-0.2 millimeter), duly reinforced with Galvanised Iron section 1.5 millimeter, wherever required. uPolyvenylchloride window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256-more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/ millimeter2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/ millimeter2(b) For the compression bending test Shall not be < 30N/ millimeter2 6 Heat Reversion Test Indian Standars :4985-2000 Shall not be > 2.0 percent 7 Surface Spread of flame BS : 476-Part 7 Classification 1 8 Ignitability Evaluation BS : 476-Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 millimeter Float Annealed glass in the sash, uPolyvenylchloride glazing bead, interlock, EPDM/TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window/Door will be fixed to the wall with 100 millimeter long and 8 millimeter diameter Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPolyvenylchloride Window and Door Profiles are warranted for a period of ten(10) years against non-uniform discoloration, wrapping and rotting under general use. :: 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash(Each sash shall be half of width of window)(Big Series) Window frame of size 122 x 54 millimeter & Sash of size 64 x 47m meter Hospital First Floor
Providing and fixing of factory made uPolyvenylchloride Sliding window & door(White Colour) complete, comprising uPolyvenylchloride multi-chambered frame having in-built uPolyvenylchloride roller track on top and uPolyvenylchloride sash with wall thickness of 2.3 millimeter(+-0.2 millimeter), duly reinforced with Galvanised Iron section 1.5 millimeter, wherever required. uPolyvenylchloride window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256-more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/ millimeter2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/ millimeter2(b) For the compression bending test Shall not be < 30N/ millimeter2 6 Heat Reversion Test Indian Standars :4985-2000 Shall not be > 2.0 percent 7 Surface Spread of flame BS : 476-Part 7 Classification 1 8 Ignitability Evaluation BS : 476-Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 millimeter Float Annealed glass in the sash, uPolyvenylchloride glazing bead, interlock, EPDM/TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window/Door will be fixed to the wall with 100 millimeter long and 8 millimeter diameter Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPolyvenylchloride Window and Door Profiles are warranted for a period of ten(10) years against non-uniform discoloration, wrapping and rotting under general use. :: 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash(Each sash shall be half of width of window)(Big Series) Window frame of size 122 x 54 millimeter & Sash of size 64 x 47m meter Hospital Second Floor
Providing and laying in situ cement concrete M30 with tremix treatment for 200 millimeter thickness for flooring with groove cutting of 4 millimeter wide and 20 millimeter deep with necessary refilling with bitumen etcetra complete.
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Hospital
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Residential Quarters
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Hospital First Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Residential Quarters First Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Hospital Second Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Residential Quarters Second Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimeter x 450 millimeter size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimeter thick supports with kadappah top 35 to 40 millimeter thick and polished granite 16 to 20 millimeter top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimeter height and top granite of 75 x 40 centimeter including cutting, opening for sink of required size in kadappah as well as granite etcetra complete.(Platform top size 5.00metet x 0.60meter and height is 0.75 meter) Residential Quarters Third Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 millimeter x 40 millimeter weighing 0.39 Kilogram/ meter at 60 centimeters c/c and fixed with(15 x 15 millimeter) flanges weighing 0.119 Kilogram/meter suspended on 6 millimeter diameter mild steel rod weighing 0.22 Kilogram/meter fixed on wall and beams including rounding of the edges with aluminium T of 50 millimeter x 40 millimeter weighing 0.39 Kilogram/meter etcetra including all labour etcetra complete. Hospital
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 millimeter x 40 millimeter weighing 0.39 Kilogram/ meter at 60 centimeters c/c and fixed with(15 x 15 millimeter) flanges weighing 0.119 Kilogram/meter suspended on 6 millimeter diameter mild steel rod weighing 0.22 Kilogram/meter fixed on wall and beams including rounding of the edges with aluminium T of 50 millimeter x 40 millimeter weighing 0.39 Kilogram/meter etcetra including all labour etcetra complete. Hospital First Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 millimeter x 40 millimeter weighing 0.39 Kilogram/ meter at 60 centimeters c/c and fixed with(15 x 15 millimeter) flanges weighing 0.119 Kilogram/meter suspended on 6 millimeter diameter mild steel rod weighing 0.22 Kilogram/meter fixed on wall and beams including rounding of the edges with aluminium T of 50 millimeter x 40 millimeter weighing 0.39 Kilogram/meter etcetra including all labour etcetra complete. Hospital Second Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed/fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etcetra all complete. Hospital
Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed/fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etcetra all complete. Hospital First Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed/fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etcetra all complete. Hospital Second Floor
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Hospital
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Residential Quarters
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Hospital First Floor
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Residential Quarters First Floor
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Hospital Second Floor
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Residential Quarters Second Floor
Providing and Fixing mat finish stainless steel(of 302 grade) railing with top pipe of 50 millimeter diameter and vertical pipe of 38 millimeter diameter at 0.60meter center/center or as required and horizontal pipes of 25 millimeter diameter in three rows, all pipes of 2 millimeter thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimeter dia above newel post of 75 millimeter diameter etcetra complete(Prior approval of sample and brand by Ex.Engineer is necessary before use) Residential Quarters Third Floor
Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etcetra complete.Hospital
Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etcetra complete.Hospital First Floor
Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etcetra complete.Hospital Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Hospital
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Residential Quarters
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Hospital First Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Residential Quarters First Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Hospital Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Residential Quarters Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimeter thick in cement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimeter thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetracomplete. Residential Quarters Third Floor
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Hospital
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Residential Quarters
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Hospital First Floor
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Residential Quarters First Floor
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Hospital Second Floor
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Residential Quarters Second Floor
Providing and applying plaster with plaster of paris in 6 millimeter thickness to previously plaster surface in all position including preparing the surface scaffolding etcetra complete. Residential Quarters Third Floor
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete. Hospital
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete.Residential Quarters
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete. Hospital First Floor
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete.Residential Quarters First Floor
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete. Hospital Second Floor
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete.Residential Quarters Second Floor
Providing and applying pearl/luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetra complete.Residential Quarters Third Floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Hospital
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Residential Quarters
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Hospital First Floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Residential Quarters First Floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Hospital Second Floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Residential Quarters Second Floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetra complete. NOTE: For Item number 15 to 18 prior approval of Superintending Engineer will be necessary Residential Quarters Third Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete. Hospital
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete.Residential Quarters
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete. Hospital First Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete.Residential Quarters First Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete. Hospital Second Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete.Residential Quarters Second Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etcetra complete.Residential Quarters Third Floor
Providing and fixing corrugated galvanised iron sheets of 0.63 millimeter thick(24 Birmingham Wire Gauge) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etcetra complete.(Weight of 5.5 Kilogram/square meter). (Second Floor) Hospital
Providing, fabricating and erecting at site of work the tubular steel structure(shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etcetra as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etcetra complete. Spec. number : As directed by Engineer-in-charge. (Third Floor)Hospital
Providing and fixing Orissa type Ivory Glazed earthenware 575 millimeter water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etcetra complete. Hospital
Providing and fixing Orissa type Ivory Glazed earthenware 575 millimeter water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etcetra complete. Hospital First Floor
Providing and fixing Orissa type Ivory Glazed earthenware 575 millimeter water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etcetra complete. Hospital Second Floor
Providing and applying one coat of thiazolinones(TZ) based Microbial Wall Wash and Anti-rooting Solution treatment as approved by Engineer in charge to entire surface of external wall. At the junction of chajja and wall and also on the parapet wall top, give a coat of anti fungal treatment. Cracks, if any, shall be filled with acrylic polymeric non-shrink crack filler putty as approved by Engineer in charge, before giving waterproofing treatment to the external surfaces. This is followed by one coat of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate(MPBP) based polymeric waterproofing solution as approved by Engineer in charge, having a non-toxic acrylic polymer liquid and white cement mix in proportion 1:1 by weight with coat interval as 24 hours. Air curing shall be done for 24 hours. Before giving this treatment the entire surface of wall shall be thoroughly cleaned to remove existing paint, dust, dirt, oil etcetra After the waterproofing treatment is cured, provide and apply two coats of titanium dioxide based 2-(methoxycarbonyl)-1-propene-butyl-2 propenoate(TMPBP) emulsion, heat insulating, waterproofing exterior coating as approved by Engineer in charge in the desired shade. The inter-coat gap to be 24 hours. The rate shall include complete treatment mentioned above. 100 percent Acrylic, Decorative, Waterproofing, Heat Insulating, Exterior Coating, Anticarbonation Coating should have following minimum properties: 1. Specific Gravity: 1.3 ± 0.1 at 25°C 2. pH: 7.0 to 10.00 3. Viscosity: 18 to 30 sec. at 25°C by Ford Cup No. B-4(Dilute 2 parts of product with 1 part of water)(If scaffolding is required, same shall be provided and will be paid under relevant item) (Second Floor) Hospital
Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger(Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 millimeter as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etcetra as per manufacturer specification. Cladding joints should be with open groove syste meter with prior approval of concerned Superitending Engineer.Hospital
Providing and fixing 900 millimeter high Stainless Steel304 Grade Stainless steel railing with 40 millimeter diameter and 1.5 millimeter thick at top, 40 millimeter diameter and 1.5 millimeter thick vertical supports spaced at 1.5meter center to center and 8 millimeter thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etcetra complete Hospital
Providing and fixing 900 millimeter high Stainless Steel304 Grade Stainless steel railing with 40 millimeter diameter and 1.5 millimeter thick at top, 40 millimeter diameter and 1.5 millimeter thick vertical supports spaced at 1.5meter center to center and 8 millimeter thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etcetra complete Hospital First Floor
Providing and fixing 900 millimeter high Stainless Steel304 Grade Stainless steel railing with 40 millimeter diameter and 1.5 millimeter thick at top, 40 millimeter diameter and 1.5 millimeter thick vertical supports spaced at 1.5meter center to center and 8 millimeter thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etcetra complete Hospital Second Floor
Stamp Concrete of 100 millimeter Thickness-Providing and Laying in-situ Mix 30 Grade unreinforced plain cement stamp concrete of 100 millimeter thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate(natural sand/Vertical Shaft Impactor grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant/non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM(on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast Ultra Voilet resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5 kilogram pe rsquare meter Including texturing, and covering with plastic sheet(min 200 micron thickness) and also applying two coats of Ultra Voilet-stable, 30 percent solids clear sealer @ 150 to 250 grams persqm using surface roller and protecting from falling dust, dirt and curring by curring compound/by providing cement vata in cement Mortor 1 :8 @ 0.6meter x 0.6meter center to center, admeasuring 80 millimeter at bottom and 40 millimeter at top with depth of 75 millimeter and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etcetra complete.(prior approval of superinteding Engineer will be necessary)Hospital
Providing and fixing collapsible steel gate in one/two leaves with hot rolled vertical channels of 18 x 9 x 3 millimeter minimum size, crossings of meterS. flats of size 18 x 5 millimeter T or E section for runner of minimum 40 x 6 millimeter size for flange, meterS. flat for top runner of minimum size 40 x 12 millimeter with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 millimeter max. spacing of vertical channels be 100 millimeter enclosed gate position and clear space of 150 millimeter between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etcetra complete.(Indian Standards 105211983).Hospital
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Hospital
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Residential Quarters
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Hospital First Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Residential Quarters First Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Hospital Second Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Residential Quarters Second Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimeter thick meterS. sheet fan hook box of size 180x100 millimeter with required depth with holes or notches as required, bottom and top sides of 1.6 millimeter meterS. sheet fixed with 3.5 millimeter diameter round headed screws together with 12 millimeter diameter meterS. bar bent to shape with hooked ends for fan hook and painting to exposed surface Residential Quarters Third Floor
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Hospital
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Residential Quarters
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Hospital First Floor
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Residential Quarters First Floor
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Hospital Second Floor
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Residential Quarters Second Floor
Providing and fixing Chrome Plated. a 2-Way BIB cock with wall flange of approved make including necessary sockets/union nut etcetra complete as directed by Engineer in charge. Residential Quarters Third Floor
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Hospital
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Residential Quarters
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Hospital First Floor
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Residential Quarters First Floor
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Hospital Second Floor
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Residential Quarters Second Floor
Providing and fixing European type wall-hung Ivory water closet of approved make with push valve concealed type with cover plate 32 millimeter size of approved make including soil pipe, vent pipe up to outside face of wall, 100 millimeter diameter Galvanised Iron plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetra complete.Residential Quarters Third Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Hospital
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Residential Quarters
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Hospital First Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Residential Quarters First Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Hospital Second Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Residential Quarters Second Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black/coloured granite of 180 millimeter thick stone black kadappa framework including chromium plated coupling bottle-Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etcetra complete.(Counter size 1.20meter x 0.60 meter) Residential Quarters Third Floor
Providing and fixing Ivory Glazed Earthenware full stall type Urinal with Poly Venyl Chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimeter diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall Hospital
Providing and fixing Ivory Glazed Earthenware full stall type Urinal with Poly Venyl Chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimeter diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall Hospital First Floor
Providing and fixing Ivory Glazed Earthenware full stall type Urinal with Poly Venyl Chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimeter diameter Poly Venyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall Hospital Second Floor
Providing and fixing Chrome Plated.Two way BIB cock of approved make continental including necessary sockets/union nut etcetra complete.Hospital
Providing and fixing Chrome Plated.Two way BIB cock of approved make continental including necessary sockets/union nut etcetra complete.Hospital First Floor
Providing and fixing Chrome Plated.Two way BIB cock of approved make continental including necessary sockets/union nut etcetra complete.Hospital Second Floor
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Hospital
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Residential Quarters
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Hospital First Floor
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Residential Quarters First Floor
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Hospital Second Floor
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Residential Quarters Second Floor
Providing and fixing 15 millimeter diameter Polyvenylchloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etcetra complete Residential Quarters Third Floor
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Hospital
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Residential Quarters
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Hospital First Floor
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Residential Quarters First Floor
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Hospital Second Floor
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Residential Quarters Second Floor
Providing and fixing wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etcetracomplete as directed by Engineer In Charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Residential Quarters Third Floor
Grab bars-Providing Stainless Steel grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar(1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR-700 millimeter and of DIA: 32 millimeter and thickness 1.5 millimeter of the roved brand and make. 27b) L Shaped grab bar(1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600 millimeter(H) X 600 millimeter(D) and 32 millimeter diameter and thickness millimeter of the approved brand and make. 27c) Straight grab bar(2 NOS) Providing S.STEEL 304 GRAB RAIL(600 millimeter), 32 millimeter diameter and thickness 1.5 millimeter of the approved brand and make.Hospital
Grab bars-Providing Stainless Steel grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar(1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR-700 millimeter and of DIA: 32 millimeter and thickness 1.5 millimeter of the roved brand and make. 27b) L Shaped grab bar(1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600 millimeter(H) X 600 millimeter(D) and 32 millimeter diameter and thickness millimeter of the approved brand and make. 27c) Straight grab bar(2 NOS) Providing S.STEEL 304 GRAB RAIL(600 millimeter), 32 millimeter diameter and thickness 1.5 millimeter of the approved brand and make.Hospital First Floor
Grab bars-Providing Stainless Steel grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar(1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR-700 millimeter and of DIA: 32 millimeter and thickness 1.5 millimeter of the roved brand and make. 27b) L Shaped grab bar(1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600 millimeter(H) X 600 millimeter(D) and 32 millimeter diameter and thickness millimeter of the approved brand and make. 27c) Straight grab bar(2 NOS) Providing S.STEEL 304 GRAB RAIL(600 millimeter), 32 millimeter diameter and thickness 1.5 millimeter of the approved brand and make.Hospital Second Floor
Providing and fixing 450 millimeter x 550 millimeter size superior type Belgium mirror with 16 millimeter diameter nickel plated towel rod etcetra complete. Hospital
Providing and fixing 450 millimeter x 550 millimeter size superior type Belgium mirror with 16 millimeter diameter nickel plated towel rod etcetra complete. Hospital First Floor
Providing and fixing 450 millimeter x 550 millimeter size superior type Belgium mirror with 16 millimeter diameter nickel plated towel rod etcetra complete. Hospital Second Floor
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Hospital
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Residential Quarters
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Hospital First Floor
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Residential Quarters First Floor
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Hospital Second Floor
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Residential Quarters Second Floor
Providing and fixing 15 centimeter rigid Polyvenylchloride Nahani trap including Polyvenylchloride grating, bend, connectingpiece of UPolyvenylchloride pipe up to the outside face of wall, making the good damaged surface and testing etcetra complete(Prior approval of sample and brand by Ex. Engr. is necessary before use) Residential Quarters Third Floor
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Residential Quarters
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital First Floor
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Residential Quarters First Floor
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital Second Floor
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Residential Quarters Second Floor
Providing and fixing on walls/ceiling/floor 15 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Residential Quarters Third Floor
Providing and fixing on walls/ceiling/floor 25 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital
Providing and fixing on walls/ceiling/floor 25 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital First Floor
Providing and fixing on walls/ceiling/floor 25 millimeter diameter CPolyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital Second Floor
Providing and fixing on walls/ceiling/floor 40 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital
Providing and fixing on walls/ceiling/floor 40 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital First Floor
Providing and fixing on walls/ceiling/floor 40 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Hospital Second Floor
Providing and constructing Brick Masonry inspection trap Chamber 90 centimeter x 45 centimeter including 1:4:8 Cement Concrete foundation, 1:2:4 Cement Concrete channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with Reinforced Cement Concrete Cover medium duty 140 Kilogram per meter etcetra complete Hospital
Providing and constructing Brick Masonry inspection trap Chamber 90 centimeter x 45 centimeter including 1:4:8 Cement Concrete foundation, 1:2:4 Cement Concrete channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with Reinforced Cement Concrete Cover medium duty 140 Kilogram per meter etcetra complete Residential Quarters
Providing and constructing Brick Masonry Inspection Chamber 60 centimeter x 45 centimeter With Reinforced Cement Concrete raft in Black Cotton soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 millimeter thick Reinforced Cement Concrete cover medium duty 100 Kilogram per meter etcetra complete. Hospital
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Hospital
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Residential Quarters
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Hospital First Floor
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Residential Quarters First Floor
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Hospital Second Floor
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Residential Quarters Second Floor
Providing and fixing 75 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete Residential Quarters Third Floor
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete. Hospital
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete.Residential Quarters
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete. Hospital First Floor
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete.Residential Quarters First Floor
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete. Hospital Second Floor
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete.Residential Quarters Second Floor
Providing and fixing 100 millimeter dia stabiliser pipe/Poly Venyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetra complete.Residential Quarters Third Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 millimeter incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etcetra complete. Hospital
Providing and fixing stainless steel sink of size 600 x 510 x 200 millimeter incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etcetra complete. Hospital First Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 millimeter incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etcetra complete. Hospital Second Floor
Providing and fixing sink cock with regular swinging spout(Wall/floor Mounted Model) with wall flange having flow rate up to 6.0 Liter/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make incluidng other necessary fitting, etcetra complete as directed by Engineer in charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Hospital
Providing and fixing sink cock with regular swinging spout(Wall/floor Mounted Model) with wall flange having flow rate up to 6.0 Liter/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make incluidng other necessary fitting, etcetra complete as directed by Engineer in charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Hospital First Floor
Providing and fixing sink cock with regular swinging spout(Wall/floor Mounted Model) with wall flange having flow rate up to 6.0 Liter/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make incluidng other necessary fitting, etcetra complete as directed by Engineer in charge.(Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Hospital Second Floor
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Hospital
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Residential Quarters
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Hospital First Floor
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Residential Quarters First Floor
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Hospital Second Floor
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Residential Quarters Second Floor
Providing and fixing chromium plated towel rod 16 millimeter diameter and 75 centimeter in length including all accessories complete. Residential Quarters Third Floor
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.Hospital
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.Residential Quarters
RWH-Recharge Pit Providing and constructing recharge pit of 2.0 meter deep and 1.0 meter diameter of pre-cast Reinforced Cement Concrete rings with 6.5" diameter x 25 meter deep borewell at the floor of recharge pit including installation of combination of solid/perforated Polyvenylchloride casing pipe wrapped around with netlon mesh including 300 millimeter thick sidefilling around outside of Reinforced Cement Concrete rings(annular space) with 40 millimeter size boulders including filling of recharge pit up to 0.5meter depth with 25-75 millimeter clean washed gravels from bottom up followed by 0.5 meter depth of 10-25 millimeter of clean washed stones followed by 0.5 meter of washed river fine aggregate(natural sand/crushed sand Vertical Shaft Impactor grade finely washed etcetra) including netlon mesh between each gravel/fine aggregate(natural sand/crushed sand Vertical Shaft Impactor grade finely washed etcetra) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Polyvenylchloride rungs, Polyvenylchloride end-caps, fittings etcetra including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
RWH-Shallow Percolation Pit providing, constructing 2.0 meter deep shallow depth percolation pit comprising of 1.0 meter diameter pre-cast Reinforced Cement Concrete rings, 300 millimeter thick side filling around outside of Reinforced Cement Concrete rings(annular space) with 40 millimeter size boulders including filling of percolation pit up to 0.5 meter depth(from bottom up) with 25-75 millimeter clean washed gravels followed by 0.5 meter depth of 10-25 millimeter of clean washed stones followed by 0.5 meter of washed river fine aggregate(natural sand/crushed sand Vertical Shaft Impactor grade finely washed etcetra) including netlon mesh between each gravel/fine aggregate(natural sand/crushed sand Vertical Shaft Impactor grade finely washed etcetra) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Polyvenylchloride rungs etcetra including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 meter and spreading for embankment or stacking as directed.Hospital- Internal Road
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 meter and spreading for embankment or stacking as directed.Residential Quarters- Internal Road
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 meter and spreading for embankment or stacking as directed. CC Drain
Supplying hard murum/kankar at the road site, including conveying and stacking complete.Hospital- Internal Road
Supplying hard murum/kankar at the road site, including conveying and stacking complete.Residential Quarters- Internal Road
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading-I Material Hospital- Internal Road
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading-I Material Residential Quarters- Internal Road
Spreading hard murum/soft murrum/gravel or kankar for side width complete Hospital- Internal Road
Spreading hard murum/soft murrum/gravel or kankar for side width complete Residential Quarters- Internal Road
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etcetra complete.Hospital- Internal Road
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etcetra complete.Residential Quarters- Internal Road
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate(natural sand/Vertical Shaft Impactor grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 millimeter, , cement content not to be less than 150kilogram /cubicmeter, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etcetra complete. with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer etcetra complete.Hospital- Internal Road
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate(natural sand/Vertical Shaft Impactor grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 millimeter, , cement content not to be less than 150kilogram /cubicmeter, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etcetra complete. with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer etcetra complete.Residential Quarters- Internal Road
Providing and laying in situ cement concrete Mix 30 with tremix treatment for 200 millimeter thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimeter wide and 20 millimeter deep with necessary refilling with polysuphide sealent(Pouring grade) confirming to BS : 5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(excluding reinforcement) with coarsen and fine aggregate Using Vertical Shaft Impactor Quality Artifitial Sand etcetra complete with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer etcetra complete.Hospital- Internal Road
Providing and laying in situ cement concrete Mix 30 with tremix treatment for 200 millimeter thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimeter wide and 20 millimeter deep with necessary refilling with polysuphide sealent(Pouring grade) confirming to BS : 5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(excluding reinforcement) with coarsen and fine aggregate Using Vertical Shaft Impactor Quality Artifitial Sand etcetra complete with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer etcetra complete.Residential Quarters- Internal Road
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 20 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade)CC Drain Hospital
Public Seating Chair.-3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
Public Seating Chair.-3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.First Floor Hospital
Public Seating Chair.-3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.Second Floor Hospital
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750m meter Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2m meter Thk. Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUT MOUSE TRAY) :-Metal Powder Coated-Black Color, CPU TROLLEY :-Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht.m meter with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimeter prelaminated particle board,
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750m meter Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2m meter Thk. Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUT MOUSE TRAY) :-Metal Powder Coated-Black Color, CPU TROLLEY :-Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht.m meter with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimeter prelaminated particle board,First Floor Hospital
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750m meter Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2m meter Thk. Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUT MOUSE TRAY) :-Metal Powder Coated-Black Color, CPU TROLLEY :-Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht.m meter with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimeter prelaminated particle board,Second Floor Hospital
Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25m meter thk additional Top on top of storage as as per drawing
Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25m meter thk additional Top on top of storage as as per drawing First Floor Hospital
Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25m meter thk additional Top on top of storage as as per drawing Second Floor Hospital
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750m meter Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2m meter Thk. Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUT MOUSE TRAY) :-Metal Powder Coated-Black Color, CPU TROLLEY :-Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht.m meter with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimeter prelaminated particle board,
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750m meter Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2m meter Thk. Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUT MOUSE TRAY) :-Metal Powder Coated-Black Color, CPU TROLLEY :-Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht.m meter with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimeter prelaminated particle board,First Floor Hospital
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750m meter Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2m meter Thk. Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter Polyvenylchloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUT MOUSE TRAY) :-Metal Powder Coated-Black Color, CPU TROLLEY :-Metal Powder Coated-Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht.m meter with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimeter prelaminated particle board,Second Floor Hospital
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.First Floor Hospital
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.Second Floor Hospital
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5( centimeters) Breadth( centimeters): 100( centimeters)Height( centimeters): 100( centimeters) Weight(Kilograms): 66(Kilogram) Seating Capacity: Five Seat
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5( centimeters) Breadth( centimeters): 100( centimeters)Height( centimeters): 100( centimeters) Weight(Kilograms): 66(Kilogram) Seating Capacity: Five Seat First Floor Hospital
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5( centimeters) Breadth( centimeters): 100( centimeters)Height( centimeters): 100( centimeters) Weight(Kilograms): 66(Kilogram) Seating Capacity: Five Seat Second Floor Hospital
Multiple Compartment Lockers @ 1140Lx 457D x 1830m meter Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830m meter Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.
Multiple Compartment Lockers @ 1140Lx 457D x 1830m meter Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830m meter Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.First Floor Hospital
Multiple Compartment Lockers @ 1140Lx 457D x 1830m meter Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830m meter Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.Second Floor Hospital
Stool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 millimeter Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge.
Stool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 millimeter Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge.First Floor Hospital
Stool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 millimeter Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge.Second Floor Hospital
Providing and applying gypsum plaster(with Gypsum material) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface(Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetracomplete.
Providing and applying gypsum plaster(with Gypsum material) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface(Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetracomplete.First Floor Residential Quarters
Providing and applying gypsum plaster(with Gypsum material) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface(Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetracomplete.Second Floor Residential Quarters
Providing and applying gypsum plaster(with Gypsum material) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface(Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetracomplete.Third Floor Residential Quarters
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering 9 to 10 Square Metre/Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etcetra complete.
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering 9 to 10 Square Metre/Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etcetra complete.Residential Quarters First Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering 9 to 10 Square Metre/Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etcetra complete. Residential Quarters Second Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering 9 to 10 Square Metre/Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etcetra complete.Residential Quarters Third Floor
Providing and laying in position flooring of telephone black/Amba White/Cat bary brown/Ruby red/Ocean Brown granite stone of approved shade and size 18 millimeter to 20 millimeter thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement mortar 1:3 curing and cleaning etcetra complete.
Providing and laying in position flooring of telephone black/Amba White/Cat bary brown/Ruby red/Ocean Brown granite stone of approved shade and size 18 millimeter to 20 millimeter thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement mortar 1:3 curing and cleaning etcetra complete.First Floor Residential Quarters
Providing and laying in position flooring of telephone black/Amba White/Cat bary brown/Ruby red/Ocean Brown granite stone of approved shade and size 18 millimeter to 20 millimeter thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement mortar 1:3 curing and cleaning etcetra complete.Second Floor Residential Quarters
Providing and laying in position flooring of telephone black/Amba White/Cat bary brown/Ruby red/Ocean Brown granite stone of approved shade and size 18 millimeter to 20 millimeter thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement mortar 1:3 curing and cleaning etcetra complete.Third Floor Residential Quarters
Providing and fixing in position(as per 1868/1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimeter at weight 0.637 Kilogram/running metre. with window frame bottom track section 92 x 31.75 x 1.30 millimeter at weight 1.070 Kilogram/running metre.. Top and side track section 92 x 31.75 x 1.30 millimeter at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/running metre. Inter locking section 40 x 18 x 1.10 millimeter at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimeter thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etcetra, complete. With colour Anodising without box
Providing and fixing in position(as per 1868/1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimeter at weight 0.637 Kilogram/running metre. with window frame bottom track section 92 x 31.75 x 1.30 millimeter at weight 1.070 Kilogram/running metre.. Top and side track section 92 x 31.75 x 1.30 millimeter at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/running metre. Inter locking section 40 x 18 x 1.10 millimeter at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimeter thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etcetra, complete. With colour Anodising without box First Floor Residential Quarters
Providing and fixing in position(as per 1868/1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimeter at weight 0.637 Kilogram/running metre. with window frame bottom track section 92 x 31.75 x 1.30 millimeter at weight 1.070 Kilogram/running metre.. Top and side track section 92 x 31.75 x 1.30 millimeter at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/running metre. Inter locking section 40 x 18 x 1.10 millimeter at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimeter thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etcetra, complete. With colour Anodising without box Second Floor Residential Quarters
Providing and fixing in position(as per 1868/1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimeter at weight 0.637 Kilogram/running metre. with window frame bottom track section 92 x 31.75 x 1.30 millimeter at weight 1.070 Kilogram/running metre.. Top and side track section 92 x 31.75 x 1.30 millimeter at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/running metre. Inter locking section 40 x 18 x 1.10 millimeter at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 millimeter at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimeter thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etcetra, complete. With colour Anodising without box Third Floor Residential Quarters
Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimeter x 1.22 millimeter box type, 5 millimeter thick sheet glass louvers, of approved quality etcetra complete.
Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimeter x 1.22 millimeter box type, 5 millimeter thick sheet glass louvers, of approved quality etcetra complete.First Floor Residential Quarters
Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimeter x 1.22 millimeter box type, 5 millimeter thick sheet glass louvers, of approved quality etcetra complete.Second Floor Residential Quarters
Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimeter x 1.22 millimeter box type, 5 millimeter thick sheet glass louvers, of approved quality etcetra complete.Third Floor Residential Quarters
Providing and fixing mild steel grill work for windows, ventilators, etcetra 15 Kilogram/square metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
Providing and fixing mild steel grill work for windows, ventilators, etcetra 15 Kilogram/square metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.First Floor Residential Quarters
Providing and fixing mild steel grill work for windows, ventilators, etcetra 15 Kilogram/square metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Second Floor Residential Quarters
Providing and fixing mild steel grill work for windows, ventilators, etcetra 15 Kilogram/square metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Third Floor Residential Quarters
Providing and fixing fly proof mesh shutter toventilator/window using Country Cut Teakwood members of size 45 x 22 millimeter for frame work and 35 x 22 millimeter for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 millimeter including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etcetra complete
Providing and fixing fly proof mesh shutter toventilator/window using Country Cut Teakwood members of size 45 x 22 millimeter for frame work and 35 x 22 millimeter for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 millimeter including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etcetra complete First Floor Residential Quarters
Providing and fixing fly proof mesh shutter toventilator/window using Country Cut Teakwood members of size 45 x 22 millimeter for frame work and 35 x 22 millimeter for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 millimeter including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etcetra complete Second Floor Residential Quarters
Providing and fixing fly proof mesh shutter toventilator/window using Country Cut Teakwood members of size 45 x 22 millimeter for frame work and 35 x 22 millimeter for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 millimeter including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etcetra complete Third Floor Residential Quarters
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 millimeter outer diameter and having wall thickness of 2.2 to 2.7 millimeter confirming to Indian Standars 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimeter to 40 millimeter from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetra complete.Residential Quarters
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 millimeter outer diameter and having wall thickness of 2.2 to 2.7 millimeter confirming to Indian Standars 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimeter to 40 millimeter from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetra complete. RWH
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 millimeter outer diameter and having wall thickness of 2.2 to 2.7 millimeter confirming to Indian Standars 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimeter to 40 millimeter from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetra complete.Residential Quarters First Floor
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 millimeter outer diameter and having wall thickness of 2.2 to 2.7 millimeter confirming to Indian Standars 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimeter to 40 millimeter from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetra complete.Residential Quarters Second Floor
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 millimeter outer diameter and having wall thickness of 2.2 to 2.7 millimeter confirming to Indian Standars 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimeter to 40 millimeter from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetra complete.Residential Quarters Third Floor
Providing and fixing 45 centimeter wide mild steel ladder of 40 millimeter x 6 millimeter mild steel flat stringers and steps of 18 millimeter diameter mild steel bar for water tank including fixing it in(1:2:4) Mix 15 cement concrete block 60 centimeter x 30 centimeter x 30 centimeter and painting the ladder complete.(Anti Corossive Paint)
Providing and fixing on walls/ceiling/floor 32 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.
Providing and fixing on walls/ceiling/floor 32 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.First Floor Residential Quarters
Providing and fixing on walls/ceiling/floor 32 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Second Floor Residential Quarters
Providing and fixing on walls/ceiling/floor 32 millimeter diameter Chlorinated Polyvenylchloride pipe with necessary fittings, remaking good the demolished portion etcetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetra complete.Third Floor Residential Quarters
Providing and fixing High Densiry Polyethylene container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20, 000 litres (Second Floor)
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 20 of trap/granite/quartzite/gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Progra millimeterable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etcetra complete. With fine aggregate(Crushed sand Vertical Shaft Impactor Grade) (Third Floor)
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (968 switch Board mainsAnd 560 Bell mains)
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator.
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting storage type water heater 50 litres capacity having standing loss <0.675 kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.AP-WH/STWH
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of one hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing, and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCBO
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 100 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. With additional 16 extension card
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/ GBS
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack or as directed as per specification No. WG-NWC/ADSL
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2
Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying & erecting pole bracket for OH conductor fabricated from ISM channel, 75x40x6mm 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OHPL/ BKT (for LA)
Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.
Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete
SITC of Main Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, MCCB -400 Amp FP for Electrical Interlock at two Places as per SLD having following items:- Main I/O 400 Amp TPN MCCB. 25 kA (Ics=100% of Icu) capacity; DG I/O 250 Amp TPN MCCB. 25 kA (Ics=100% of Icu) capacity ; Bus bar chamber TPN & E with aluminium bars 400 A. Outgoing- 250AFP MCCB -1 Nos. 200AFP MCCB -1 Nos. ; 100AFP MCCB -4 Nos.Spare; 120AFP MCCB -3 Nos.Spare; 40- 63A FP MCB C series -7Nos.; 6-32A DP MCB C Series- 4 Nos
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary claMp for erection on wall.
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP (Main Pump -1, Jocky Pump-1,Disel Eng Pump-2, Booster Pump -1)
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Air Cushion Tank (Air Vessel) (ACT) Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NR
Supplying and erecting 80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NR
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 150 MM dia with necessary fittings as per specification no. FF-PP
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 100 MM dia with necessary fittings as per specification No. FF-PP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 75/80 MM dia with necessary fittings coMplete as per specification no. FF-PP
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/AR
Pressure Gauge (PG) Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Pressure Switch(PS) Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200) mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating / powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Street Light Panel Foundation frame)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. ( for Street Light Cable - 167 + for Pump Cable - 38)
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) for 2 nos St. Light Panel + DG Set
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).(For Bollard Foundation), (0.25*0.25*0.45)*10
Supplying, erecting & marking FPMCB 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame
Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS
Supplying and erecting minimum Three & above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 0.75 KW/1HP for erection on open well, pump having delivery head from 30 to 15 m and discharge from 30 to 270 litres. per minute & pipe of Suction 32 mm/Delivery 25 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (1 working + 1 standby)-Domestic Pump Hospital-2Nos, Res Qtrs-2 Nos
Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP ( DG Set Neutral)
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (for DG Set control Cabeling)
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC ( MS Cabin - 1, Conferance - 2)
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
SupSupplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity :- 20 Passenger/1360Kg · Floors :-G+2 floor (3 Stops/3 Landings) · Travel :- 6.4 mtrs · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1100mm wide x 2000 mm high · Clear Car size of 1800mm wide x 1700mm deep x 2250mm high · Lift shaft available having clear size of 2300mm wide x 3340mm deep, 1800mm Pit depth, 4150 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) "• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. • COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings." "• Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. • ARD complete with necessary SMF VRLA batteries. • Fireman controller having fireman switch at fire Landing." "• CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20"" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength." "• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. • Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT." "• General: - Job includes entire procedure of obtaining all necessary erection permissions & ""License to Work the Lift"" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. • The above rate includes Fully Comprehensive AMC for one year from the date of commissioning."
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of one hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS (for CCTV)
Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD
Supplying & erecting 43" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.
Supplying, installing, testing & commissioning of 16/20 Ch. Network Video Recorder (NVR), suitable for 2 MP cameras only with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 160Mbps with minimum 2 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 4/1, RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, support multibrand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer. support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator.
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut-out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(25*5 I.e.0.590kg/mtr, so =90.86)+ for LA.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB
Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of two hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying & erecting inline D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits.Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire, D.P. Structure shall be erected in c.c. foundation complete
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) , with standard accessories complete with test certificate with losses below 475 Watts at 50% load, 1650 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG Note For section less than 1200 mm width, reduce rate by Rs 200/- per 100 mm or part thereof for reduction in width of 1200 mm.
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 2450 mm in height using B class GI pipe, hinges and angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation and painted complete as per specification no SS-AS/DLD
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
ABC powder type fire xtingusher
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Street Light Panel Foundation frame)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. ( for Street Light Cable - 167 + for Pump Cable - 38)
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete (St Light Panel - 5 Kg + Pump - 5 kg + DG Panel - 5 kg)
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame
Supplying and erecting minimum Three & above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 1.5 KW/2HP suitable for erection on open well, pump having delivery head from 29 to 7 m and discharge from 30 to 600 litres. . per minute & pipe of Suction 50 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP (1 working + 1 standby)- Borewell Pump
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
SITC of Electric Traction Passenger Lift with · Rated capacity :- 4 Passenger/272Kg· Floors :- G+2 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 700/800 mm wide x 2000 mm high· Clear Car size of 1600mm wide x 1750mm deep x 2250mm high · Lift shaft available having clear size of 1600mm wide x1750mm deep1500mm Pit depth, 4250mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames. The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). "Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. • COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings." "• Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. • ARD complete with necessary SMF VRLA batteries. • Fireman controller having fireman switch at fire Landing." "• CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength." "• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. • Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT." "• General: - Job includes entire procedure of obtaining all necessary erection permissions & ""License to Work the Lift"" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. • The above rate includes Fully Comprehensive AMC for one year from the date of commissioning."
SAURABH CONSTRUCTION
OMKAR CONSTRUCTION
Klassic Associates
Hirani Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid