Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC 22A ASWINI DUTTA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹50.5 L+₹49,413 (0.99%)Rejected-Finance 52A 1A NAZIR LANE KIDDERPORE KOLKATA 700023 | KOLKATA | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹50.8 L+₹81,835 (1.64%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L3 | Rejected-Finance other than lowest |
Tender Value
₹39.9 L
EMD Value
₹79,800
Closing Date
5 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
ADDN/ALTN IN GROUND FLOOR AREA OF BLDG NO. OD - 4 INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2022_MES_556637_1
8916/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹79,800
1 Dec 2022
8 Oct 2022
7 Nov 2022
8 Oct 2022
5 Nov 2022
22 Oct 2022
Amount
Dismentling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and directed.
Dismentling Brick tiles or terracing tiles, single layer on roofs, complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick below or above GL complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and directed.
M&L for 40mm thick brick tiles laid or beddeded in cement mortar (1:6) and joints grouted flush in 15mm thick cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska , complete all as specified and directed.
M&L for 2nd class hard wood clean swan in scantlings etc., complete all as specified and directed.
M&L for PCC (1:5:10) type E2 (using 40mm graded crushed stone aggregate) as in fillins as mass concrete, complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation filling, fixing of post holes, support to flag pipe and mass concrete complete all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in floor, finished even and fair for flooring of tiles, complete all as specified and as directed
M & L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) as in sub base of floor, finished even and fair for flooring of tiles, complete all as specified and as directed
M&L for machine cut kota stone slab flooring 18-20 mm thick, laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
All as per item No.18 above, but in riser of steps, skirting, dados and pillers, laid over and including 10 mm thick cement plaster in cement mortar 1:4 and jointed etc complete all as specified and directed.
S&F Non-skid ceramic coloured tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, set and jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L glazed coloured digital ceramic tiles in vertical surface 300 X 450 X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L for Mirror polishing on Marble / Granite / Kota stone / any Stone work wherever required to give high gloss finish, complete all as specified and directed.
Cutting chases, pinning in, making good to facings of brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, all as specified and directed.
M&L mild steel rolled sections as in main and cross beams, angle, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors etc conforming to grade Fe-410-0 or Fe-310-0 made to required shape and size, welded at joints complete all as specified and directed
M&L Mild steel framed work such as grills of ornamental type, gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works incl portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc confirming to grade Fe-290. Gde-E-165 complete all as specified and directed.
M&L Expanded metal cut to length bent to shap required and tying with and including annealed mild steel wire not less than 0.9mm dia weight n exc 4 Kg/Sqm or fixing with galvanised steel staples fixed to wooden of steel frame including rebating etc complete all as specified and directed.
S&F 0.80mm thick mild steel black sheet in hearths, covering to door shut ters; covering to door chowkats (frames), chullah hoods; water tanks; water troughs, ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/SQM on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No. 28 above, but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
M&L for brick work using old size sub class 'B' fly-ash bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L Providing cement concrete type B1 (1:2:4) using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) with joints to match complete all as specified and as directed.
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required exc half brick but not exc one brick etc., complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/Paving etc, finished even and smooth using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair ( upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
Supply only liquid water proofing compound Make: Pidilite or equivalent, all as specified and directed.
M&L for rendering 15mm thick on brick or concrete walls in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on ceiling surfaces finishing even and smooth without using extra cement in cement mortar 1:3 including necessary scaffolding complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Complete removal of existing treatment on plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Complete removal of existing treatment on plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L Preparing new plastered surfaces of walls and applying Two Coats of Distemper Oil Emulsion over a coat of alkali resistant primer and applied over and including 1.5 mm thick wall putty complete all as specified and as directed.
M&L applying two coat of cement base paint over a coat of chalk whiting on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of exterior acrylic emulsion weather proof paint over a coat of primer to new wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufactuirer's isntructions, with and including 2mm thick exterior wall care putty complete all as specified and as directed complete all as specified and as directed.
M&L for preparation of old wood and wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, all as specified and directed.
Chipping of unsound/weak concrete materials including cover plaster from RCC stuctural member i.e slabs, lintal, chajja fin, facia etc. 50 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign material, loose concrete/ aggregate etc and disposal of all debris out side of MOD land and complete all as specified and directed.
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (Make of primer- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars upto 12 mm dia for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Quoted rate is deemed to be inclusive of the cost of reinforcement bars)
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth including formwork, scaffolding etc complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for dubbing out average 10mm thick cement plaster in CM (1:4), on irrugular faces of walls (when specifically ordered in writing) complete all as specified and directed.
S&F in repair Cast iron work grade FG 150, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles (weight n exc 5 kg each) complete all as specified and directed.
M&L for taking down plants/vegetaion from wall upto roof level by means of cutting holes into brick wall and making good the surfaces of dismantling portion n.exc 150 Sqcm superficial area and n.exc on brick deep by PCC 1:3:6 type C1 (using 20 mm graded stone aggregates) and plastering in cement mortar (1:4) of disturb portion and applying two coats of cement based paint over a coat of primer to match the existing surfaces height upto 4th floor incl necessary scaffolding etc complete all as specified and directed.
Surface Excavation not exc 30 Cm deep and averaging 15 Cm deep and getting out in soft/loose soils, complete all as specified and as directed.
Removing excavated material exc. 50 m but n exc. 1.5 km and depositing where directed complete all as specified and directed.
M & L for pre-polished Chequered cement concrete tiles (coloured) of size 30cmx30cmx25mm thick , set , jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
S&F in position, at or near ground level, factory made precast cement concrete kerb stone blocks, in M-25 grade cement concrete, fixed to the required line, level and curvature, jointed in cement mortar 1:3, including making joints with or without grooves (thickness of joints, except at sharp curves shall not be more than 5 mm) including making drainage opening wherever required complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
M&L for Anodized aluminum frame for doors, windows, ventilators and partition with one or more rebate including joining cleat for fixing etc complete all as specified and directed..
M&L for anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and directed. (NOTE: Glass shall be measured and paid seperately)
S&F 4.8 mm thick sheet glass frosted on one side, area in squares exc 0.5 sqm in each pane and glazing with rubber gasket fixed to aluminium frame work / snap beading complete all as specified and as directed by the Engineer-in-Charge
S&F 0.90 mm thick laminate, fixed to ply wood or blockboard with suitable adhesive as per manufacturer's instructions, complete all as specified and directed.
S&F Door closer hydraulically regulated, designation No. 3, universal type, aluminium (die cast) body, suitable for door shutters of 851 to 1000 mm in width & weight between 61 to 80 kg complete all as specified and directed.
S&F 4 lever mild steel type Mortice lock vertical type size 100mm complete all as specified and directed.
Taking down carefully copper/aluminium point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc., (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to MES Store for keeping in safe custody for re-use and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including galvanised mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 67 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 67 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 67 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
Labour only for concealed type point wiring (retrived from taking down here and before) with existing 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit with accessories, fixed to walls/ceiling, including galvanised mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and existing 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 71 above, but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 71 above, but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 71 above, but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S & F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S & F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Bell push 6 Amps, 1 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet, non-shuttered, 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 15/16 Amp one way complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete with all necessary electrical connection all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 100 watts, 5 Speed Control, 230/240 Volts complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
S&F Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F MCB (premium range), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB (Premium Range), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Labour only for re-fixing of Old serviceable (Obtained from taking down) MCB DB any type any size and any toyr with common busbar, complete all as specified and directed.
Labour only for fixing of MCB (premium range), 'C' series, SPN, 32 Amps, breaking capacity 10KA (Obtained from taking down), complete all as specified and directed.
Labour only for fixing of MCB (Premium Range), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA (Obtained from taking down), complete all as specified and directed.
M&L for sub main wiring with two run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Two run of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
Taking down and re-fixing of recess mounted LED luminaire in any capacity, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories etc., and connecting up with new three core flexible copper conductor wire of adequate size complete all as specified and directed.
S&F in repairs PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F Ceiling fan down rod of GI tubing "medium grade" of size 15 mm dia duly painted with two coats of synthetic enamel paint over a coat of primer and making hole for extension of fan hook in high roof ceiling, as in repairs, complete all as specified and directed.
Taking down carefully serviceable ceiling or exhaust fans, any size or type and depositing in MES store for re-use, complete all as specified and as directed by Engineer-in-Charge.
Hanging and fixing ceiling fan, any sweep or size (Obtained from taking down) and connecting up including provision of flexible copper wire from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Fixing only exhaust fan, any sweep or size (Obtained from taking down) and connecting up including provision of flexible copper wire from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
M/S S. K. SARKAR
DEB AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .