THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
OFFICE OF THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
Annual rate contract for Repairs and Maintenance of 33/11KV Receiving stations (District Budgam) falling under the jurisdiction of Sub Transmission Division-II, Rajbagh,Srinagar for the year 2024-25 or till next rate contract
2024_PDD_249665_1
eNIT No. STD-II / 07 of 2024-25 Dated 07-06-2024
Open Tender
Electrical and Maintenance Works
Item Rate
1 days
BUDGAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
₹30,000
20 Jul 2024
11 Jun 2024
16 Jul 2024
11 Jun 2024
15 Jul 2024
11 Jun 2024
Amount
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of fresh breaker contacts for 11kV VCB by way of Replacement of Damaged/Burnt Out breaker contacts of same composition,type,make and class already installed in 11KV VCB panel of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of fresh clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) by way of replacement of Damaged/Burnt Out one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing,commissioning of Tripping coils (30V/36V/110V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing,commissioning of Closing coils (30V/36V/110V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of make already installed at Receiving Stations including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T ,C.T ,Transformers(Both H.V & L.V Side, Pad Clamps) by way of Replacement of Damaged/Burnt Out one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type) (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of 11KV LV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type) (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one outdoor type including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3) confirming to IEC:185 and IS:2705 (part-1 to 4) standards outdoor type by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing,installation,testing and commissioning of fresh 33KV isolators 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards with earthing blade / without earthing blade by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,Testing and commissioning of 11KV G.O Set 800 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V) by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,Testing and commissioning of 11KV Isolators,800amps. conforming to IS 9921/IEC-129 standards with earthing blade/without earthing blade by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Oil Toping of 33/11 KV Power Transfromers including carriage/transportation of spared item to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation, testing and commissioning of WTI/OTI by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 33KV side including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 11KV side including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Supply, Installation,testing and commissioning of Bucholz relay by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers including carriage/transportation of damaged material/equipment to Divisional Stores. The job includes draining of oil and the topping of the same
Supply, Installation,testing and commissioning of MOG ( Magnetic Oil Level Guage) by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers including carriage/transportation of damaged material/equipment to Divisional Stores
Rectification/ arresting of leakage of power transformers of different ratings by way of replacement of damaged/worn out gaskets , suitable gas welding of radiator fins.(The job includes providing of set of Gaskets)
Supply, Installation,testing and commissioning of 30V,200 AH/150AH/ 100AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores
Supply, Installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores
Installation,testing and commissioning of 30V,200 AH/150AH/ 100AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Laying,Testing,commissioning of 11KV (E) grade armoured ,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
120mm^² 3-core
Laying,Testing,commissioning of 11KV (E) grade armoured ,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
400mm^² 1-core
300mm^² 1-core,
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any by way of replacing the damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
120mm^² 3-core
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) suitable for Xlpe Power Cable by way of replacing the damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
120mm^² 3-core
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any by way of replacing the damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
400mm^² 1-core
300mm^² 1-core,
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) suitable for1-core Xlpe Power Cable by way of replacing the damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
400mm^² 1-core
300mm^² 1-core,
Installation,testing and commissioning of copper Bus Bar (2ftx10mm) by way of replacing the damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Repairing of Re-Setting Links of 11 KV VCB Panel
Repairing of operating shaft of 11 KV VCB Panel
Repairing of Shower Contact of 11 KV VCB Panel
Repairing of Isolating Sockets of 11 KV VCB Panel
Repairing of High Tension Spring of 11 KV VCB Panel
Repairing of Tripping Shaft of 11 KV VCB Panel
Repairing of Rollers of 11 KV VCB Panel
Repairing of Latch Assembly of 11 KV VCB Panel
Repairing of Gear Assembly of 11 KV VCB Panel
Repairing of Tripping Mechanism of 11 KV VCB Panel
Repairing of Spring Charge Motor Assembly of 11 KV VCB Panel
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of make already installed at Receiving Station
Replacement of Re-Setting Links of 11 KV VCB Panel
Replacement of operating shaft of 11 KV VCB Panel
Replacement of Shower Contact of 11 KV VCB Panel
Replacement of Isolating Sockets of 11 KV VCB Panel
Replacement of High Tension Spring of 11 KV VCB Panel
Replacement of Tripping Shaft of 11 KV VCB Panel
Replacement of Rollers of 11 KV VCB Panel
Replacement of Latch Assembly of 11 KV VCB Panel
Replacement of Gear Assembly of 11 KV VCB Panel
Replacement of Tripping Mechanism of 11 KV VCB Panel
Replacement of Spring Charge Motor Assembly of 11 KV VCB Panel
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of make already installed at Receiving Station
Deco Spray Painting
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacing the damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Voltmeter 11KV/110V
Ammeter
LED panel Indicators
Push Button
HRC fuse with Base -16 Amps
10Amp MCB C type
Panel Control re-wiring with 2.5 sqmm multistranded copper wire FRHR 1.1KV grade flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc
Installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores)
Installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores).
Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel. including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores).
Fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different makes by way of replacement of damaged one including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores).
Installation,testing and commissioning of master trip relay 24-50 V by way of Replacement of Damaged/Burnt of same type,make and class already installed in 11KV VCB panel including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores).
Installation,testing and commissioning of Yard lights by way of Replacement of Damaged/Burnt of type already installed ncluding carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores).
Installation testing and commissioning of Trivector meter (RS 485) by way of Replacement of Damaged/Burnt out including carriage/transportation of damaged material/equipment to Divisional Stores (Material to be provided by the department and to be lifted from Divisional Stores).
Supply, Installation,testing and commissioning of 120 mm² 1 Core, PVC LT Cable
Supply, Installation, Testing & Commissioning of Outdoor type LT control panel of suitbale size made out of 2.0mm CRCA sheets including cleaning and finishing complete with powder coating in approved shade having AI-Bus Bar of rating 200A for both incoming and outgoing circuits, high conductivity connections, with necessary nuts and bolts, clamps, lugs, DMC Bus Bar supports etc housing 200 Amp 4P 36kA MCCB, with MICROPROCESSOR release of standard make (1No) and LT prodigy meter (0-100A). The LT Panel shall be mounted on angle iron pedestal 600mm height (50x50x6mm) angle frame duly painted. This also include GI Stand of suitable size along with Cement Grouting (Complete Job)
Supply, Installation,testing and commissioning of 1sqmm multistranded copper wire FRHR 1.1KV voltage grade
Supply, Installation,testing and commissioning of 4sqmm multistranded copper wire FRHR 1.1KV voltage grade
Supply, Installation,testing and commissioning of modular 16AMP SS combine
Supply, Installation,testing and commissioning ofof modular board 6/4 way
Supply, Installation,testing and commissioning of 10AMP Modular switches
Supply, Installation,testing and commissioning of of 32 AMP type C MCB
Supply, Installation,testing and commissioning of 16Amp Type C MCB
Supply, Installation,testing and commissioning of of 12 way double door MCB board
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Note: 1. The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off. 2.The material to be provided by the department shall have to be lifted from Divisional stores 3. The replaced/damaged/spared out material/equipment shall have to be transported to Divisional Stores
POWER TECH ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .