Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹4.8 L
EMD Value
₹9,554
Closing Date
20 Jan 2026, 10:55 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer Electrical sub-Division-VI
Office of the Assistant Engineer Electrical Sub-Division No-V Sagarbhanga Durgapur -713211
Renovation and Repairing work of old unservicable Electrical installation work of Four A type, Three C type and one D type flat at Suri Lalkuthipara RHE under Durgapur Electrical Section H.D
2025_HSD_978643_1
WBHD/AE/ESD-V/e-NIT-08/25-26
Open Tender
ELECTRICAL WORKS ORG
Percentage
60 days
Lalkuthipara Housing
Same as refer tender document
3 documents required · 3 mandatory
₹9,554
82 Belgachia Road Kolkata
8 Jan 2026
8 Jan 2026
22 Jan 2026
8 Jan 2026
20 Jan 2026
10 Jan 2026
9 Jan 2026
Part I -A type flat. Dismantling the existing wiring and mending good the damages .(NS)
Supplying and fixing 240/415 V 40 A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection(Make- L&T/ABB/LEGRAND) ( PWD Schedule Vide Page No:D6 Item No-07)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way ( PWD Schedule Vide Page No:D9 Item No-11)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+6Way, Make- L&T/ABB/Seimens/ Havells. ( one for power point and one for inverter point ) ( PWD Schedule Vide Page No:D9 Item No-13)
Supplying and fixing 240/415 V40 A DP MCB Isolator on din rail of existing DBs and necessary connection. ( L&T/ABB/LEGRAND)( PWD Schedule Vide Page No:D6 Item No-5)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32 A, SP, Make- L&T/ABB/Seimens ( Vide Page No:D6 Item No-07)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand - Anchor) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 6 mtr ( Vide Page No:E25 Item No-4b)
Do----Do-----------On Board ( Vide Page No:E24 Item No-3a)
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. ( Vide Page No:D13 Item No-22)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand - Anchor) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. ( Vide Page No:E18 Item No-10)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand - Anchor) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Two for inverter connection Two for power point) ( Vide Page No:18 Item No-9b)
Supply & Fixing 240 V, 20 A Piano key type switch (Brand - Anchor) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( For geyser point ) ( Vide Page No:E-6 Item No-17b)
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module ( Vide Page No:E-17 Item No-1b)
Supply & Fixing 240 V 6 A Modular type switch (Brand - Anchor) on existing GI Modular type switch board having top cover plate and making necessary connections as required ( Vide Page No:E-17 Item No-3a)
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand - Anchor), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. ( Vide Page No:D9 Item No-11)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand - Anchor), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.( For Two no. AC point and one geyser point) ( Vide Page No:E-17 Item No-5a)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. ( Vide Page No:D3 Item No-20a)
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand - Anchor) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. ( For water purifier) ( Vide Page No:E-18 Item No-9a)
S & F 240V,25A, Modular type starter(Brand - North- West) 20A Modular.Switch type DP MCB (C-Curve) and 4 Modul GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S& F switch board and cover plate and make necy. Connections with PVC Cu wire and earth continuity wire etc. ( Vide Page No:E-19 Item No-117)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand - Finolex / Gloster/ KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required ( Vide Page No:E9 Item No-1) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (Main switch To SPN DB)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC ( For A.C. Point, geyser point & inverter point)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC ( For power Point)
3 x 22/0.3 (1.5 sqmm)
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 19 mm dia 3 mm thick polythene pipe without earth continuity wire ( Vide Page No:E2 Item No-3a)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 6 SWG ( Vide Page No:G2 Item No-5aii)
Excavation of soil for installation of Earth Electrode and filling & ramming ( Vide Page No:G-1 Item No-1b)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe ( Vide Page No:G-1 Item No-2a)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required ( Vide Page No:G-2 Item No-4a)
Part II -C type flat. Dismantling the existing wiring and mending good the damages as per G.S (N.S)
Supplying and fixing 240/415 V 40A, DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make- L&T/ABB/Simens)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+6Way, Make- L&T/ABB/Seimens/ Havells. ( one for power point and one for inverter point )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 40A, DP, L&T/ABB/Seimens
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32 A, SP, Make- L&T/ABB/Seimens
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand - Finolex/KEI/Gloster) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed (Anchor)on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed Average run 6 mtr
Do----Do-------On Board
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & Fixing Socket type fan regulator (Step type) (Brand - Anchor) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand - Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (two for inverter connection and two for power point)
Supply & Fixing 240 V, 20 A Piano key type switch (Brand - Anchor) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( For geyser point )
Supply & Fixing 240 V, 20 A plug socket (Brand -Anchor), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. ( one for geyser point & one for AC point )
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 100 mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 100 mm x 100 mm x 65 mm
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 175 mm x 100 mm x 65 mm
Supply & Fixing 240 V 6 A Piano key type switch (Brand - Anchor) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand -Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. ( For water purifier)
S & F 240V,25A, Modular type starter(Brand - North- West) 20A Modular.Switch type DP MCB (C-Curve) and 4 Modul GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S& F switch board and cover plate and make necy. Connections with PVC Cu wire and earth continuity wire etc.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand - Finolex / Gloster/ KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a)2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (Main switch To SPN DB)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC ( For A.C. Point, geyser point & inverter point)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC ( For power Point)
3 x 22/0.3 (1.5 sqmm)
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 19 mm dia 3 mm thick polythene pipe without earth continuity wire
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 6 SWG
Excavation of soil for installation of Earth Electrode and filling & ramming
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe ( for four nos Building)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Part III -D type flat. Dismantling the existing wiring and mending good the damages as per G.S
Supplying and fixing 240/415 V 40A, DP, Make- L&T/ABB/Legrand MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+6Way, Make- L&T/ABB/Seimens/ Havells. ( one for power point and one for inverter point )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 40A, DP, L&T/ABB/Seimens
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32 A, SP, Make- L&T/ABB/Seimens
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand - Finolex/KEI/Gloster) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed (Anchor)on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed Average run 6 mtr
Do----DO----------On Board
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bak
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand - Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (two for inverter connection and two for power point)
Supply & Fixing 240 V, 20 A Piano key type switch (Brand - Anchor) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( For geyser point )
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. ( one for geyser point & one AC point )
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 100 mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 100 mm x 100 mm x 65 mm
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 175 mm x 100 mm x 65 mm
Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. ( For water purifier)
S & F 240V,25A, Modular type starter(Brand - North- West) 20A Modular.Switch type DP MCB (C-Curve) and 4 Modul GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S& F switch board and cover plate and make necy. Connections with PVC Cu wire and earth continuity wire etc.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand - Finolex / Gloster/ KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (Main switch To SPN DB)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC ( For A.C. Point, geyser point & inverter point)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC ( For power Point)
3 x 22/0.3 (1.5 sqmm)
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 19 mm dia 3 mm thick polythene pipe without earth continuity wire
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 6 SWG
Excavation of soil for installation of Earth Electrode and filling & ramming
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe ( for four nos Building)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Add GST @18%
Add LW Cess @1%
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tendernotice_2.pdf
PDF • 1.48 MB
BOQ_2385053.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .