Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.9 LQualified E 11 SUSHANT LOK II NEAR FLORENCE CLUB SECTOR 56 GURUGRAM 122011 HARYANA | GURUGRAM | HARYANA | 122011 | ₹98.9 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹1.1 Cr+₹13.8 L (14.0%)Qualified | ₹1.1 Cr+₹13.8 L (14.0%) | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹1.2 Cr+₹21.5 L (21.8%)Qualified 1 11215 FIRST FLOOR STREET NO 13 SUBHASH PARK SHAHDARA EAST DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹1.2 Cr+₹21.5 L (21.8%) | L3 | Qualified MSE, MII, Category: General |
| 4 | L4₹1.3 Cr+₹29.1 L (29.4%)Qualified 201 A SHUBHAM CENTRE NO 1 CARDINAL GRACIOUS ROAD VILLAGE TOWN CHAKALA ANDHERI EAST CITY MUMBAI MUMBAI MAHARASHTRA 400099 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400099 | ₹1.3 Cr+₹29.1 L (29.4%) | L4 | Qualified MII |
| 5 | Disqualified GROUND FLOOR NO 44 APMC YARD APMC YARD KAMALANGAR BIDAR KARNATAKA 585417 | BIDAR | KARNATAKA | 585417 | - | - | Disqualified MSE, MII, Category: OBC |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
8 Nov 2024, 6:00 pmClosed
Replacement of Coils and AHUs of AAI preferred makes and
7040137
GEM/2024/B/5520680
Two Packet Bid
Dismantling of cooling coil from existing installed Air Handling Unit 1330 mm x 1680 mm, 60mm Stati
120 days
Goa; South Goa
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹3
40%
₹3.0 L
8 Nov 2024
18 Oct 2024
8 Nov 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Dismantling of cooling coil from existing installed Air Handling Unit 1330 mm x 1680 mm, 60mm Static Pressure suitable for AHUs | Dismantling of cooling coil from existing installed Air Handling Unit including dismantling of Air filter section Coil section disconecting the existing chilled water pipeline ducting etc as required and installing new cooling coil as per item No. 02 making piping connections alongwith insulation with 50 mm nitrile rubber making good any drainage etc including transportation of new coil to the site AHU Room unloading loading including shifting of the old dismantled coil to the store etc as required and as per direction of Engineer In Charge 1330 mm x 1680 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 1.1 page no 194 | 2 | Nos | goa@electrical | 120 |
| 2 | Dismantling of cooling coil from existing installed Air Handling Unit 1512 mm x 2035 mm, 60mm Static Pressure suitable for AHUs | Dismantling of cooling coil from existing installed Air Handling Unit including dismantling of Air filter section Coil section disconecting the existing chilled water pipeline ducting etc as required and installing new cooling coil as per item No. 02 making piping connections alongwith insulation with 50 mm nitrile rubber making good any drainage etc including transportation of new coil to the site AHU Room unloading loading including shifting of the old dismantled coil to the store etc as required and as per direction of Engineer In Charge 1512 mm x 2035 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 1.2 page no 194 | 1 | Nos | goa@electrical | 120 |
| 3 | Dismantling of cooling coil from existing installed Air Handling Unit 1010 mm x 2080 mm, 60mm Static Pressure suitable for AHUs | Dismantling of cooling coil from existing installed Air Handling Unit including dismantling of Air filter section Coil section disconecting the existing chilled water pipeline ducting etc as required and installing new cooling coil as per item No. 02 making piping connections alongwith insulation with 50 mm nitrile rubber making good any drainage etc including transportation of new coil to the site AHU Room unloading loading including shifting of the old dismantled coil to the store etc as required and as per direction of Engineer In Charge 1010 mm x 2080 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 1.3 page no 194 | 10 | Nos | goa@electrical | 120 |
| 4 | Dismantling of cooling coil from existing installed Air Handling Unit 889 mm x 1790 mm, 60mm Static Pressure suitable for AHUs | Dismantling of cooling coil from existing installed Air Handling Unit including dismantling of Air filter section Coil section disconecting the existing chilled water pipeline ducting etc as required and installing new cooling coil as per item No. 02 making piping connections alongwith insulation with 50 mm nitrile rubber making good any drainage etc including transportation of new coil to the site AHU Room unloading loading including shifting of the old dismantled coil to the store etc as required and as per direction of Engineer In Charge 889 mm x 1790 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 1.4 page no 194 | 2 | Nos | goa@electrical | 120 |
| 5 | Dismantling of cooling coil from existing installed Air Handling Unit 850 mm x 2085 mm, 60mm Static Pressure suitable for AHUs | Dismantling of cooling coil from existing installed Air Handling Unit including dismantling of Air filter section Coil section disconecting the existing chilled water pipeline ducting etc as required and installing new cooling coil as per item No. 02 making piping connections alongwith insulation with 50 mm nitrile rubber making good any drainage etc including transportation of new coil to the site AHU Room unloading loading including shifting of the old dismantled coil to the store etc as required and as per direction of Engineer In Charge 850 mm x 2085 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 1.5 page no 194 | 1 | Nos | goa@electrical | 120 |
| 6 | Supply of new coil of following sizes with chilled water coils having copper pipe 1330 mm x 1680 mm, 60mm Static Pressure suitable for AHUs | Supply of new coil of following sizes with chilled water coils having copper pipe 12 to 15 mm diameter OD with 0.4 mm minimum thickness with Hydrophilic coated aluminium fins firmly bonded to copper tubes assembled in zinc coated steel frame,fin spacing shall be 4-5 fins per cm,including transportation upto site etc as required 1330 mm x 1680 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 2.1 page no 194 | 2 | Nos | goa@electrical | 120 |
| 7 | Supply of new coil of following sizes with chilled water coils having copper pipe 1010 mm x 2080 mm, 60mm Static Pressure suitable for AHUs | Supply of new coil of following sizes with chilled water coils having copper pipe 12 to 15 mm diameter OD with 0.4 mm minimum thickness with Hydrophilic coated aluminium fins firmly bonded to copper tubes assembled in zinc coated steel frame,fin spacing shall be 4-5 fins per cm,including transportation upto site etc as required 1010 mm x 2080 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 2.2 page no 194 | 10 | Nos | goa@electrical | 120 |
| 8 | Supply of new coil of following sizes with chilled water coils having copper pipe 1205 mm x 1730 mm, 60mm Static Pressure suitable for AHUs | Supply of new coil of following sizes with chilled water coils having copper pipe 12 to 15 mm diameter OD with 0.4 mm minimum thickness with Hydrophilic coated aluminium fins firmly bonded to copper tubes assembled in zinc coated steel frame,fin spacing shall be 4-5 fins per cm,including transportation upto site etc as required 1205 mm x 1730 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 2.3 page no 194 | 1 | Nos | goa@electrical | 120 |
| 9 | Supply of new coil of following sizes with chilled water coils having copper pipe 1512 mm x 2035 mm, 60mm Static Pressure suitable for AHUs | Supply of new coil of following sizes with chilled water coils having copper pipe 12 to 15 mm diameter OD with 0.4 mm minimum thickness with Hydrophilic coated aluminium fins firmly bonded to copper tubes assembled in zinc coated steel frame,fin spacing shall be 4-5 fins per cm,including transportation upto site etc as required 1512 mm x 2035 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 2.4 page no 194 | 1 | Nos | goa@electrical | 120 |
| 10 | Supply of new coil of following sizes with chilled water coils having copper pipe 889 mm x 1790 mm, 60mm Static Pressure suitable for AHUs | Supply of new coil of following sizes with chilled water coils having copper pipe 12 to 15 mm diameter OD with 0.4 mm minimum thickness with Hydrophilic coated aluminium fins firmly bonded to copper tubes assembled in zinc coated steel frame,fin spacing shall be 4-5 fins per cm,including transportation upto site etc as required 889 mm x 1790 mm, 60mm Static Pressure suitable for AHUs as per SH 1 Item no 2.5 page no 195 | 2 | Nos | goa@electrical | 120 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7040137.pdf
GEM_BID
ahu_coil_tender_book_2024-10-18-17-19-40_372a2d7905a3e051eefd7f449288c440.pdf
BOQ
boq_of_replacement_of_coil___ahu_2024-10-18-17-19-41_a23c81036f6746b6453c0ffd7ef4b9d3.csv
BOQ
1729253086.xlsx
OTHER
TenderCoil_04bdec1d-c7c1-4748-b3c71729253419914_goa@electrical.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .