Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.1 LAccepted-AOC DEORA THANA WAIDHAN DISTT SINGRAULI M P | WAIDHAN | SINGRAULI | MADHYA PRADESH | 486887 | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹33.7 L+₹38,856 (1.17%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹33.8 L+₹53,986 (1.62%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹35.9 L+₹2.6 L (7.91%)Rejected-AOC H NO 177 GOVINDPURA SATWARI JAMMU CANTT 180003 J K | JAMMU | JAMMU AND KASHMIR | 180003 | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹36.0 L+₹2.7 L (8.00%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹41.8 L
EMD Value
₹83,560
Closing Date
7 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
SPECIAL REPAIR TO MD ACCN TYPE I, II, AND III (1 TO 4) BLOCKS AT CSD RESIDENTIAL COMPLEX AT BD BARI MIL STN UNDER GE KALUCHAK
2023_MES_613101_1
GE/KC/NIT-28/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹83,560
Yes
20 Nov 2023
10 Aug 2023
14 Sept 2023
10 Aug 2023
7 Sept 2023
24 Aug 2023
10 Aug 2023 - 17 Aug 2023
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 01 here-in-before, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto triple storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
10mm thick rendering in cement mortar 1:4 on concrete surfaces of chajjas, upward fascias, ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm on vertical surfaces such as skirting/dado etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 10mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Glazed ceramic coloured tiles of size 300mmx200mm thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Machine cut kota stone slab flooring, 18-20 mm thick as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 20mm screed layer in cement mortar 1:4, complete all as specified & directed.
Machine cut kota stone slab, 18-20 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed.
Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in back fill of chowkats and bed plate of holdfast and similar items, complete all as specified and as directed.
35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified & directed.
Factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet 5mm thick to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplied & fitted in the frame at site as per specification & drawings shown in SSR Part-II, complete as specified & directed.
Steel ventilator with top hung shutter including hinges, steel peg stay, complete including taking down old unserviceable ventilator, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
3mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Mild steel galvanised wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or 2nd class soft wood beading etc, complete all as specified & directed.
Butt hinges, medium weight, cold rolled, mild steel 100mm long, complete all as specified & directed.
Aluminium handle, cast type, anodised, 150mm long, complete all as specified & directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, 300mm long, complete all as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long, complete all as specified & directed.
Steel locking bolts with mild steel electrogalvanized plate and bright bolt not less than 10mm dia, 100mm size, complete all as specifed & directed.
300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel and fixed to pressed steel frame / MS frame/ wooden chowkhats including necessary welding work etc where-ever required, complete all as specified & directed.
18/19mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber framed work as in cup board shutters, shelves etc., fixed in repairs, complete all as specified & directed.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 40mm, complete all as specified & directed.
40mm dia, copboard knobs fixed with nut, screw and washer of mild steel, brass polished, complete all as specified & directed.
100mm size Hasp and staple, safety type, aluminium with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, laid in a stretch not exc 3m and joint at every turning/corners complete all as specified & directed.
25mm thick PCC 1:2:4 nominal mix, type B-1, using 20mm graded stone aggregate as in floors, finished even and fair to receive floor finishes, complete all as specified & directed.
Dismantling water tanks of capacity of 500 litres, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) triple layered, hoisted & fixed in position of capacity 500 ltrs including making necessary arrangements for fixing of inlet, outlet, over flow pipe, wash out pipe etc, complete all as specified & directed.
20mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), fixed in repairs, complete all as specified & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed.
Stop valves, cast copper alloy, 20mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Stop valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Brass chromium plated WHB mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15mm bore of pipe, fixed in repairs, complete all as specified & directed.
Brass chromium plated shower rose of 125mm size with or without swivel joints, fixed in repairs, complete all as specified & directed.
Stainless steel grating of 125mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, fixed in repairs, complete all as specified & directed.
Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified & directed.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs, complete all as specified & directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
Dismantling of cast iron or reinfored concrete drain pipes, jointed in cement mortar and taking out of trenches or fixed with walls, if required, internal dia of pipe 100mm, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, complete all as specified.
Dismantling of cast iron or reinfored concrete drain pipes, jointed in cement mortar and taking out of trenches or fixed with walls, if required, internal dia of pipe 75mm, complete all as specified & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius, complete all as specified & directed.
Stainless steel plate rack of size 1200x900x250mm made out of AISI 304 stainless steel 1 mm thick having partitions including brass/stainless steel screws for fixing of partitions, nuts, bolts, washers and fittings, complete all as specified & directed.
Complete removal of the existing sunken treatment including roughening and preparation old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and applying the following treatment :- (a) 15 thick rendering on fair faces of brick work or cement surfaces in cement mortar 1:4 with using integral water proofing compound as per manufacturer instructions by weight of cement to sunken portion including wall of sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement, finishing concrete including walls of sunken portion with proper slope. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. Note : Ponding shall be done in sunken portion area by filling water which shall be kept there for 48 Hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
50mm thick, PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in sub base of floor, hard standing, path, pavings etc, complete all as specified & directed.
Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing existing water tank of any capacity, refixing at same place after making necessary arrangements, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
25mm outer dia stainless steel decorative drapery rod (including necessary fittings) of thickness 20 gauge, for every 1 RM length provide 10 numbers stainless steel wings of 50mm dia and proportionate for part off with stainless steel brackets near to ends with stainless steel finials for 25mm dia drapery rod ar both ends, complete all as specified & directed. Note: The drapery rod shall be projected 150mm outer side from the closer opening of doors/windows.
Precast reinforced cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid seprately.
Preparation of new plastered or concrete surfaces of walls and applying two coats of exterior weather proof paint over a coat of primer, complete all as specified & directed.
Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
Preparation of old decorated wooden or wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of white wash, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer over 1 mm thick wall care putty, complete all as specified & directed.
Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified & directed.
Brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) triple layered, hoisted & fixed in position of capacity 1000 ltrs including making necessary arrangements for fixing of inlet, outlet, over flow pipe, wash out pipe etc, complete all as specified & directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc. 10cm girth in brick/stone walls, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 25mm, complete all as specified & directed.
Vitreous china, wash hand basin, flat back, white of size 550mmx400mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, waste pipe, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 110mm bore with oval access door , complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 75mm bore with oval access door , complete all as specified & directed.
PVC (SWR) vent cowl of size 110mm bore, complete all as specified & directed.
Complete removal of existing treatment of any description from wall surfaces by washing, rubbing down and stopping of distempered/painted wall surfaces and applying 1 mm thick wall care putty and painted with two coats of oil emulsion distemper over a coat of primer, complete all as specified & directed.
Complete removal of existing treatment of any description from wall surfaces by washing, rubbing down and stopping of distempered/painted wall surfaces and two coats of exterior weather proof paint over a coat of primer, complete all as specified & directed.
Mild steel framed work as in grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified & directed.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 104 above but for one 3/5 pin 6 Amps socket outlet on independent board.
All as per Srl item No. 104 here-in-before but for one 3/5 pin 6 Amps socket outlet on same board.
All as per Srl item No. 104 here-in-before but for one light point controlled by two numbers two way switches.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 4.0 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15/16 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 6 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch piano flush type 15/16 Amps 240 Volts single pole one way, complete all as specified & directed.
Switch piano flush button 6 Amp single pole, two way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5/6 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 6 & 15/16 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Bell push flush type, one way 6 Amps single pole one way, complete all as specified & directed.
Call bell, Ding Dong AC. 230 volts, single pole, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
PVC body exhaust fan, 250mm (10") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose & taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified & directed.
Supply, installation and testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard, complete all as spcified & directed.
Factory made epoxy powder coated distribution board vertical type, VTPN, 4 ways with metal double door (IP-43 protection) confirming to IS : 8623, fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar, cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one MCCB 63/100/160 Amp 4P as incomer and MCBs SP/TP as outgoing, complete all as specified & directed.
MCCB of capacity 63 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 12 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCB, TPN, 100 Amp, 50 Hz AC supply, 10 KA repturing capacity, 415 Volt, 'C' curve, complete all as specified & directed.
MCB, single pole & neutral, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6 sqmm and one run of 4 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire efficacy >110 Lumens per Watt, Secondary optics for better light distribution, having two nos Potted driver (OEM) (one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Cutting/ boring of road/hard standing to a size of 30cm in width and not exc 60 cm in depth for laying of protection pipe / water line/ cable including returning, filling in, spreading, romoval of surplus soil and providing 100mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate on top, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
Galvanised iron tube 50mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
M/s Des Raj and Sons
KAMAL CONSTRUCTION
M/S A TO Z ENGINEERS
M/S SUDAGAR MAL
M/s K.S. Constructions
M/S Vishwakarma Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .