REPAIR/REPLACEMENT OF VARIOUS HANGER LIGHTS AND FIXTURES IN TECH HANGARS AT AFS YELAHANKA
2026_MES_791745_1
8602/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹36,000
Yes
30 Sept 2026
30 Sept 2026
28 Oct 2026
30 Sept 2026
21 Oct 2026
14 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down the unserviceable light fitting complete all as specified and directed. | 259 | Each | - | - |
| 2 | Taking down old unserviceable sub main wiring of any size complete all as specified and directed. | 223 | RM | - | - |
| 3 | Supply and fix LED flood light 150 Watts, 230 V AC outdoor type with thermal management in multiple optics, powder coated pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts including testing commissioning and fixing upto 20 Mtr hight of hangar including necessary fixing arrangement of clamps nut bolts etc complete all as directed. | 25 | Each | - | - |
| 4 | Supply and fix LED flood light 200 Watts, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampCCT 5700K, lumen efficacy not less than 110 lumen/watts including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts, chain locking etc complete all as directed. | 40 | Each | - | - |
| 5 | All as per item No 4 here-in-before but 250 Watts. | 20 | Each | - | - |
| 6 | Supply and fixing industrial LED High Bay light fitting power range of 200 Watts, powder coated PDC aluminium body & PC optical lenses, Lumen efficiency of >110lm/W, 5700K CCT, Alluminum Die cast housing, IP66 with life of 50,000hrs with Eye bolt provided for mounting purpose for fixing on wall/ceiling mount available as accessory, flexible options to meet industrial lighting needs i.e. suspended/fixed to Hangar Ceiling, cool white light colour, material made out of die cast aluminum & extruded aluminum heat sink and finish powder coated complete connecting electrically including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts, chain locking etc complete all as directed. | 20 | Each | - | - |
| 7 | Supply and fix LED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. | 90 | Each | - | - |
| 8 | Supply and fix in repair driver suitable for 150 Watt LED flood light fittings and testing complete all as specified and directed. | 10 | Each | - | - |
| 9 | Supply and fix in repair driver suitable for 200/250 Watt LED Flood light fittings and testing complete all as specified and directed. | 14 | Each | - | - |
| 10 | Supply and fix LED Aviation light luminaries Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed. | 4 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Binder1.pdf
Tender Documents • 0.62 MB
BOQ_887681.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .