Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | ₹27.5 L Quoted ₹28.9 L | L1 | Accepted-AOC Accepted being lowest bidder |
| 2 | L2₹30.0 L+₹1.1 L (3.89%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | ₹30.0 L+₹1.1 L (3.89%) | L2 | Rejected-Finance Not become lowest bidder |
| 3 | L3₹31.5 L+₹2.7 L (9.26%)Rejected-Finance | ₹31.5 L+₹2.7 L (9.26%) | L3 | Rejected-Finance Not become lowest bidder |
| 4 | L4₹31.7 L+₹2.8 L (9.80%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | ₹31.7 L+₹2.8 L (9.80%) | L4 | Rejected-Finance Not become lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
27 Oct 2020, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
REPAIR/MAINT/REPLACEMENT OF LT OH LINES, FEEDER PILLAR BOXES, LT PANELS, VARIOUS CABLES AND OTHER MISC WORKS UNDER AGE E/M AT GE JHANSI
2020_MES_380268_1
GE/JHA/TOK/44 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
₹80,000
Yes
29 Dec 2020
23 Sept 2020
2 Nov 2020
23 Sept 2020
27 Oct 2020
13 Oct 2020
Amount
Material & Labour for Power Cables, Aluminum Stranded Conductor 400 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Havells / Polycab / Universal / Gloster / KEI. (Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.)
All as per item No. 1.00 here-in-before but of size 300 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 240 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 185 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 120 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 95 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 50 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 25 sqmm, 4 core.
All as per item No. 1.00 here-in-before but of size 16 sqmm, 4 core.
All as per item No. 1.00 here-in-before but of size 10 sqmm, 2 core.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard / dense soil for laying of cables complete all as specified and directed by Engineer-in-Charge.
Supply and spread M-sand in trenches for cushioning of cable complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment)
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and lay in trenches, un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cutting of existing hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below hard standing will be measured and paid under relevant items.
Supply and fix in replacement of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. Make : Jindal / Tata / Zenith / Prakash Surya
All as per item No. 17.00 here-in-before but of size 80mm dia bore.
All as per item No. 17.00 here-in-before but of size 50mm dia bore.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Kisan / Prince / Tirupati /Supreme / Jain Irrigation Sys
Design, fabricate, supply, installation, testing and commissioning of outdoor type dust proof & vermin proof cubicle panel board compartmentalized with separate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1500mm x 1300mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexible cables and lugs of suitable grade/capacity complete all as specified and directed including taking down existing unserviceable LT panel of any description:- Note: (i) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations. Make of Panel builder: Universal Switchgear Control, New Delhi / United Engineering Services, Kanpur / Mclayers, Bhopal / BAFNA Electric Panel / SaB Engineers & Consultants, Kanpur
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed by Engineer-in-Charge. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, supply and filling in layers of charcoal and salt, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix in replacement of Thermoplastic cable junction box IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry) of size 205mm x 255mm x 112mm with provision of 63Amps rated four pole (3P+N) connector, one single pole MCB of 6 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables and PVC gland for copper control cable for light fitting including fixing on steel tubular poles / PCC poles with 20mm x 3mm MS clamps with fixing brackets (02 Nos), nuts, bolts, washers etc duly painted with two coats of aluminium paint over a coat of red oxide primer on steel clamps and brackets etc including taking down existing unserviceable street light junction box of any description complete all as specified and directed by Engineer-in-Charge. Make: Hensel/ Sintex / Gewiss
Making holes (02 Nos - one near cable junction box and other near street light bracket) on existing steel tubular poles of any type, thickness & height through drilling / gas welding work having smooth and chamber edge of hole, for drawing street light control cable through inside of pole complete all as specified and directed by Engineer-in-Charge.
Supply and connect in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, three core, 1.5 sqmm for connecting from junction box to street light fitting including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge. Make: Make: Finolex / Havells / Polycab / Universal / Gloster / KEI
Shutdown the power supply, disconnecting all incoming & outgoing cables carefully from outdoor type LT panel board, removing the burnt wiring, cleaning the bus bars, insulators and MCCBs with CTC, meggering the insulation value and replacing the bus bar supporting insulators wherever required to achieve required insulation resistance value, tightening all fasteners (renew if required), reconnecting back the incoming and outgoing cables with suitable cable Lugs, glands and wrapping the insulation tape on all bare conductors, supply and fixing EPDM rubber gasket for all doors for dust & vermin proof etc and testing on completion for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: (i) Replacement of unserviceable MCCBs shall be measured and paid separately. (ii) Replacement of broken/corroded metal sheets/ angle iron parts of panel boards shall be measured and paid separately.
Supply and fabrication of 2.0mm thick Mild steel, plain, black sheets as in housing/doors to existing LT panel boards, wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitered angles, etc. as required and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including cutting and removing corroded sheet complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work LT panel boards or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete in Fe 410 -W (Gde- E- 250) quality- A and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including cutting and removing corroded frames complete all as specified and directed by Engineer-in-Charge.
Preparation of old steel surfaces of outdoor type LT panel boards of any size and painting with synthetic enamel paint of approved colour over a coat of red oxide primer (both internally & externally) and fixing 02 Nos steel danger plates on panel board complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB, 500 A, 4 Pole, 50 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : L&T / Havells / C&S / Indo Asian
Supply and fix in replacement of MCCB, 400 A, 4 Pole, 50 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : L&T / Havells / C&S / Indo Asian
Supply and fix in replacement of MCCB, 250 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : L&T / Havells / C&S / Indo Asian
Supply and fix in replacement of MCCB, 200 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : L&T / Havells / C&S / Indo Asian
Supply and fix in replacement of MCCB, 160 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : L&T / Havells / C&S / Indo Asian
Supply and fix in replacement of MCCB, 125 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : L&T / Havells / C&S / Indo Asian
Material and labour for Surface dressing not exc 15cm deep in any type of soil and site clearance including cutting and removing of plants/bushes, leveling of surface area, throw wastage material out of fencing area/ compound wall up to 50m distance at sub station areas / pump House areas complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed by Engineer-in-Charge.
Supply and erection in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 meters long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole including taking down existing unserviceable pole of any description complete all as specified and directed by Engineer-in-Charge. (Note: Excavation and concrete shall be measured and paid separately under relevant items of this BOQ). Make : India Electric Poles / Bombay Tubes / National Tubing Company / Bharat Conduit and Steel / Kalinga Tubes /Quality Steel Products
Material and labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping of pole including necessary form work complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old painted surfaces of LT 9.0 meter long poles and painting with one coat of aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole including applying one coat of snow cem on pcc coping of pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for pruning of tree branches up to 2.0 meter clearance all around HT/LT overhead lines and depositing where directed at a distance not less than 50m complete all as specified directed by Engineer-in-Charge. Note: The item will be measured in span length between poles. The approx span length is 50m.
Unbinding the existing HT/LT overhead lines of any configuration and size of conductor by opening the binding wire from insulators and Re-stringing to the required tension and sag and binding with new aluminium binding wire of suitable gauge complete all as directed by Engineer-in-Charge.
Supply and fix replacement of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts for working pressure 1100 volts of size 75mm height and 90mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of ACSR conductor for HT/LT overhead line and proper stringing to required tension and sag including binding with new aluminium binding wire of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No. 1 complete all as specified and directed by Engineer-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately)
Supply and fix in replacement of Galvanized stay strand, 7/3.15mm including proper tightening to required tension complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil.
Material and labour for mild steel work as in replacement of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description not exc 10 cm in width or girth and painting with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed.
Supply and fix in replacement of Galvanized Steel Chain Link fencing of mesh size 50mm x 50mm and dia of wire 4.00mm with and including line wires fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
Material and labour for Framed work in replacement such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed and hung as gates, including pestle hinges, stops, hand-made sliding bolts, etc. conforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed by Engineer-in-Charge.
Material and labour for Mild steel bars in replacement, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc conforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil in the transformer yard complete all as specified and directed by Engineer-in-Charge.
Supply and spread graded coarse aggregate of 63mm nominal size around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ bricks on plan built in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed.
M&L for white / colour washing on walls double coat including preparation of old/new surfaces complete all as directed.
Supply and fix in replacement of MCCB 100A, 16KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosure including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : C&S / Indo Asian / L&T / Havells
Supply and fix in replacement of MCCB 200A, 25KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosure including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : C&S / Indo Asian / L&T / Havells
Supply and fix in replacement of on-load change over switch, 160A, 4 pole, 415V, 50 Hz in sheet steel enclosure with front operated handle including taking down existing unserviceable changeover switch of any description complete all as specified and directed by Engineer-in-Charge. Make : C&S / Indo Asian / L&T / Havells
Supply and fix in replacement of on-load change over switch, 200A, 4 pole, 415V, 50 Hz in sheet steel enclosure with front operated handle including taking down existing unserviceable changeover switch of any description complete all as specified and directed by Engineer-in-Charge. Make : C&S / Indo Asian / L&T / Havells
Material and labour for servicing of Gang Operated Device Air Break Switch, 11 KV, 3 pole, 200 Amps, Horizontal / Vertical mounted type including proper adjustment of male and female contacts, cleaning and applying petroleum jelly to the contacts complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Switch Air Break, gang operated, Triple pole, mechanically operated, vertical mounted on 09 insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps suitable for 11000 volts grade including taking down existing unserviceable GOD of any description complete all as specified and directed by Engineer-in-Charge. Make : Pactil / MEI / Jaipuria Brothers / Southern Switchgear / HEI / BHEL / ELPRO / Atlas /Rashtriya
Supply and fix in replacement of 11000 volts grade, expulsion type drop out fuse set mounted on 06 insulators and steel frame of current rating up to 50 Amps including taking down existing unserviceable drop out fuse set of any description complete all as specified and directed by Engineer-in-Charge. Make : Pactil / MEI / Jaipuria Brothers / Southern Switchgear / HEI / BHEL / ELPRO / Atlas /Rashtriya
Design, Fabricate, supply, installation and testing of outdoor type cubicle panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40mmx40mmx5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions) for accommodating and including provision of following switchgears complete:- Make of Panel builder: Universal Switchgear Control, New Delhi / United Engineering Serices, Kanpur / Mclayers, Bhopal / BAFNA Electric Panel / SaB Engineers & Consultants, Kanpur (i) TPN Aluminium bus bar of 40 x 5 mm provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands. (ii) MCCB, 200 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (Make : L&T / Havells / C&S / Indo Asian)
M/S Kumar Contractors
M/s Jagdish Chandra Arora
ROHIT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .