Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | ₹28.0 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹31.7 L+₹3.7 L (13.0%)Rejected-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | ₹31.7 L+₹3.7 L (13.0%) | L2 | Rejected-AOC Not L1 Bidders |
| 3 | L3₹31.8 L+₹3.8 L (13.5%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹31.8 L+₹3.8 L (13.5%) | L3 | Rejected-AOC Not L1 Bidders |
| 4 | L4₹32.4 L+₹4.4 L (15.6%)Rejected-AOC | ₹32.4 L+₹4.4 L (15.6%) | L4 | Rejected-AOC Not L1 Bidders |
| 5 | L5₹32.4 L+₹4.4 L (15.6%)Rejected-AOC H NO 28 FIRST FLOOR E BLOCK KARMPURA WEST DELHI 110015 | WEST DELHI | DELHI | 110015 | ₹32.4 L+₹4.4 L (15.6%) | L5 | Rejected-AOC Not L1 Bidders |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
18 Apr 2025, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR AND MAINTENANCE OF DG SETS RO PLANTS CONTROL PANEL EARTHING SYSTEM STREET LIGHT ALONGWITH CONNECTED ITEMS FOR WATER SUPPLY INSTALLATION UNDER AOR OF AGE U WATER SUPPLY NO 1 UNDER GE U WATER SUPPLY DELHI CANTT 10
2025_MES_702260_1
GE/WS/Token-27 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹96,000
Yes
20 Jun 2025
21 Mar 2025
21 Apr 2025
21 Mar 2025
18 Apr 2025
4 Apr 2025
Amount
M&L Periodical mainteneance of DG Sets for proper functioning as per manufacturer's recommendations of following capacities of Make : Kirloskar/Greaves/ Mahindra/Cummins/Ashok Leyland all as per existing site by replacing Filters (Fuel filter, Lube Oil Filter, By Pass Filter), Air Cleaner both inner and outer element, Water seperator, Engine oil of suitable grade as per OEM recommendation upto upper level, Checking for diesel leakage and Cleaning of Diesel Tank thoroughly, Cleaning of Radiator after removing of old coolant completely with water and suitable radiator Cleaning agent, Oiling and Greasing of Engine Parts, Checking of all hose pipes, tightening of all pipes, cable conncections, Cleaning and Servicing of alternator, Cleaning of Exhaust Pipe, Silencer including checking for leakage of smoke alongwith replacement of minor spare parts if any, complete all as specified and directed by Engr-in-charge. Note :- (i) Rate Quoted shall include the cost of distilled water for batteries and Fuel filters, Lube oil filters, By pass filter, Air filter and minor spares. (ii) Engine Oil and Coolant shall be measured and paid separately under respective items.
Note:- (i) Major Spares parts/oil/coolent etc required for maintenance will be measured and paid seprately under relevant items. (ii) Minor spare parts i.e. nut bolt, washer, petroleum jelly deemed to be included in the quoted unit rate of this item (iii) DHPP will be issued by dept for testing only and the same will be collected by contractor at his own arrangement. (iv) Servicing to be carried out as per manufacturer’s specifications/ instructions on OEM workshop only. Inventory will be prepaired by workshop of OEM authorities and the same will be signed by JE E/M & Engineer-in-Charge. (v) The work of maintenance , repair and overhauling shalll be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge. (vi) Proper record & test results of the same shall be maintained as directed. (vii) Work shall be carried out at site at different location (viii) OEM workshop will be approved by GE for servicing of DG Set after recommendation of EIC in writing. Transportation charges of DG Set upto workshop and back to site will deemed included in quoted unit rate. (ix) Installation, testing and commissioning of DG Set shall be carried out after over hauling from approved workshop repersentatives and satisfactorly test reports kept on record duly got verified by IEM of HQ CEDZ Delhi Zone.
DG Set 30 to 50 KVA Capacity
DG Set 62.5 to 82.5 KVA Capacity
DG Set 100 to 125 KVA Capacity
DG Set 160 to 200 KVA Capacity
DG Set 400 KVA Capacity
Supply and filling of genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and as directed. (Note:- Coolant shall be supplied in sealed container only & PV's & MTC will be submitted by contractor before payment in RAR).
Supply & filling of syenthetic Engine oil, multi grade premium Genuine oil type SAE 20W 40 grade as per manufacturer recommendations in DG sets complete all as specified and as directed. (Note:- Engine oil shall be supplied in sealed container and PV's & MTC will be submitted by contractor before payment in RAR.)
Supply only replacement of Fan Belt for following capacities DG Sets of existing make complete all as specified and directed by Engr-in-charge. (Note:- Old U/s fan belt material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
DG Set 30 to 50 KVA Capacity
DG Set 62.5 to 82.5 KVA Capacity
DG Set 100 to 125 KVA Capacity
DG Set 160 to 200 KVA Capacity
DG Set 400 KVA Capacity
Supply only replacement of V-Belt for following capacities DG Sets of existing make complete all as specified and directed by Engr-in-charge. (Note:- Old U/s V- belt material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
DG Set 30 to 50 KVA Capacity
DG Set 62.5 to 82.5 KVA Capacity
DG Set 100 to 125 KVA Capacity
DG Set 160 to 200 KVA Capacity
DG Set 400 KVA Capacity
M&L repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing u/s parts re-assembling the pump after repair/replacement of parts and testing by caliberation as per sample DG set of Cap 30-82.5 KVA complete all as specified and as directed.
M&L repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing u/s parts re-assembling the pump after repair/replacement of parts and testing by caliberation as per sample of DG Set Cap 100-180 KVA complete all as specified and as directed.
M&L repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing u/s parts re-assembling the pump after repair/replacement of parts and testing by caliberation as per sample of DG Set Cap 400 KVA complete all as specified and as directed. (Note for ser item No 6 to 8:- Old U/s FIP material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
M&L for taking down and servicing of radiator assembly and replacement of minor parts, de-scaling of tubes with chemical solution, welding/brazing leak testing including transportation to workshop and re-fixing after repairs and testing commissioning complete all as specified and directed by Engr-in-charge. (Note:- Old U/s radiator material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
DG Set 30 to 50 KVA Capacity
DG Set 62.5 to 82.5 KVA Capacity
DG Set 100 to 125 KVA Capacity
DG Set 160 to 200 KVA Capacity
DG Set 400 KVA Capacity
S&F in replacement of maintenance free Tubular Battery 12V, 180 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge.
S&F in replacement of maintenance free Tubular Battery 12V, 150 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge.
S&F in replacement of maintenance free Tubular Battery 12V, 115/120 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge.
S&F in replacement of maintenance free Tubular Battery 12V, 90/100 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge. (Note for ser item No 10 to 13:- (i) Old U/s tabular battery obtained from dismantling shall deposited in MES store yard at AGE (U) W/S-I and taken on demolition ledger charge in 'Each' for further disposal through auction. (ii) Maufacturer's test certificate and warranty certificate of batteries will kept on record duly signed by EIC.)
S&F in replacement of Battery lead copper conductor of size 50 Sqmm multistranded PVC insulated with suitable terminals at both ends of required length for each battery complete all as specified and directed. (Note:- Old U/s copper conductor material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill.)
M&L for repair of self starter with replacament of carbon bushes, pinion, rewinding of stator and rotor winding with approved quality of winding wire as per existing and replacement of defective parts to make the starter fully functional and commissioning and testing of DG set of any type and capacity complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s copper conductor material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply and Fixing of Battery Lugs/Connectors of suitable capacity as per the site complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Hose Pipe Set of suitable capacity for the following capacities of DG sets complete all as specified and directed:-
Up to 62.5 KVA DG Set
82.5 KVA to 180 KVA DG Set
200 KVA to 400 KVA DG Set
M&L preparing old rusted surface of DG sets upto 400KV capacity by thoroughly cleaning the surface to remove dust, rust flakes, paint flakes using wire brush or sand paper, primimg the affected surface with anti-corrosive primer and applying paint using suitable sprayer to get a smooth glossy surface finish and writing MES Number of DG Set (both Engine and Alternator) at site in Block capital letters as per existing sample complete all as specified and directed by Engr-in-Charge.
M&L in repair of DG Set Control Panel of capacity 30-82.5 KVA including replacement of defective sensors like AMF module, relay card/board, current transformer, Key switch, Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge.
M&L repair of DG Set Control Panel of capacity 100-400 KVA including replacement of defective sensors like AMF module, relay card/board, current transformer, Key switch, Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge. (Note:- Old U/s parts material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
M&L in replacement of "Coolant Tempetarure sensor" suitable for 30-400 KVA DG Set capacities of make Cummins/Kirloskar/Ashok Leyland/Mahindra including connection with circuit panel, starting and testing ON- load complete all as specified and directed by Engineer-in-Charge.
M&L in repair of old hinges and fixing new with fitting/welding as per existing size complete all as specified and as directed.
S&F in replacement of Aluminium Strip 25x3.15 mm as roof conductor or down conductor or along the pole/pipe complete with saddles/insulators made out of porcelain or fibre alongwith fixing screws complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s aluminium strip obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill.)
S&F in replacement of Battery Charger of 6 Amps rating of 12V Battery complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Battery Charger of 6 Amps rating of 24V Battery complete all as specified and directed by Engr-in-Charge. (Note for ser item No 24 & 25 :- Old U/s battery charger obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill.)
M&L complete fixing in repairs for DG set accoustic enclosure door Hinges / Aldrops / Locks with 02 Keys including carrying out necessary modifications complete all as specified and directed by Engr-in-Charge. (Note :- Old U/s hinges from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
M&L earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32x6 mm as earthing lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion & dismentling of existing pit & pit cover complete all as specified and as directed. (Note:- (a) Excavation & earth work shall be deemed included in quoted unit rate. (b) GI earth strip 32x6mm of length 7.5Rm from earth test point shall be deemed included in quoted unit rate. (c) Old U/s material demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply & fixing in replacement MCCB thermal relay range 200- 250 Amps, 4 pole 415V of breaking capacity 36 KA and and connecting to bus bars and cable end termination with suitable lugs complete all as specified and directed.
Supply & fixing in replacement MCCB thermal relay range MCCB 160-200 Amps, 4 pole, 415 V, breaking capacity 36 KA complete all as specified and directed.
Supply & fixing in replacement MCCB thermal relay range 4 pole MCCB 63-80 Amps,415 V, breaking capacity 18 KA complete all as specified and directed. (Note for ser item No 28 to 30:- Old U/s MCCB from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill).
Supply and fixing in replacement of burnt/ unsv 3 pole power contactor Type ML-1.5/MNX 25, 25 Amp ,415/220 volts ,50 Hz coil voltage 415 Volts alongwith NO/NC as applicable complete all as specified and directed.
Supply and fixing in replacement of burnt/unsv 3 pole power contactor Type ML-2.0/MNX 32, 32 Amp ,415/220 Volts ,50 Hz coil voltage 415 Volts alongwith NO/NC as applicable complete all as specified and directed.
Supply and fixing in replacement of burnt/unsv 3 pole power contactor Type ML-3/Suitable MNX Type, 40 Amp ,415/220 Volts ,50 Hz coil voltage 415 Volts alongwith NO/NC as applicable complete all as specified and directed.
Supply and fixing in replacement of burnt/unsv 3 pole power contactor Type ML-4/MNX Type, 70 Amp ,415/220 Volts ,50 Hz coil voltage 415 Volts alongwith NO/NC as applicable all as specified and directed.
Supply and fixing in replacement of burnt/unsv 3 pole power contactor Type ML-6/Suitable MNX Type, 110 Amp ,415/220 Volts, 50 Hz coil voltage 415 Volts alongwith NO/NC as applicable all as specified and directed.
Supply and fixing in replacement of thermal over load relay type ML-1.5/MNX type relay range 13-21 Amps complete all as specified and as directed.
Supply and fixing in replacement of thermal over load relay type ML-2.0/MNX type relay range 20-32 Amps complete all as specified and as directed.
Supply and fixing in replacement of thermal over load relay type ML-3.0/MNX type relay range 28-42 Amps complete all as specified and as directed.
Supply and fixing in replacement of thermal over load relay type ML-3.0/MNX type relay range 30-50 Amps complete all as specified and as directed.
Supply and fixing in replacement of thermal over load relay type ML-4.0/MNX type relay range 45-75 Amps complete all as specified and as directed.
Supply and fixing in replacement of thermal over load relay type ML-6.0/MNX type relay range 66-110 Amps complete all as specified and as directed. (Note for ser item No 31 to 41 :- Old U/s material demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in iron scrap in (KG) shall be taken into account and attach with RAR/F Bill).
M&L for comprehensive periodical maintenance of RO Plants for their proper functioning as per manufacturer's recommendations of following capacities of any make as per site by complete unit checkup incl electrical machinery, general cleaning, backwashing, chemical cleaning of cartridge and replacement of all type of filters on quarterly basis as per the complaint during the contract Period, testing and commissioning complete all as specified and directed. (Note :- (i) Membrane and other consumables as well as spare parts shall be measured and paid separately under respective items. (ii) Old U/s parts demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill. (iii) RO plant over hauling and maintenance shall be carried out by approved OEM workshop. Proper 'Inventory' of replaced spare parts shall be prepaired and submitted by contractor obtained from workshop duly seal & signed for record purpose. Guarantee of spare parts of at least one year will be gievn by contractor in their letter head and if any function of RO repaired not working in this period the same will be carried out by contractor 'Free of cost' to Govt.
RO Plant of 10 LPH Capacity
RO Plant of 100 LPH Capacity
RO Plant of 200 LPH Capacity
RO Plant of 3000 LPH Capacity
RO Plant of 10000 LPH Capacity
Supply only RO membranes including 2 (Two) years warantee of following capacities of approved make as per OEM in complete all as specified and directed.
RO Plant of 10 LPH Capacity
RO Plant of 100 LPH Capacity (Type : 4012)
RO Plant of 200 LPH Capacity (Type : 4040)
RO Plant of 3000 LPH Capacity (Type : 8040)
RO Plant of 10000 LPH Capacity (Type : 8040)
M&L for opening dual media FRP vessel of size existing at site by taking out old unserviceable items and refilling the vessel with filter media items complete all as specified and directed by Engr-in-Charge.
Supply only Filter media items of approved quality and make complete all as specified and directed. (Note:- Stack measurement of loose quantity shall be entered in MB for payment after deduction of 'VOIDS').
Carbon 1200 ID (For commercial water treatment plant)
Pebbles
Silex/Silica
Supply only following chemicals of approved make and quality as per OEM in sealed container :- (Note:- Perishable items shall be supplied in sealed container only.)
Antiscalant Chemical
Sodium Bicarbonate Solution for pH correction
Supply only following items and spares for RO plant of approved make and quality as per OEM:
Pressure Gauge
Pressure Switch
Level Switch
Flow Indicator
HDPE Dozing Tank of Cap-100 Litres best quality of same OEM.
M&L for repair to high pressure pump of rating upto 10 HP of discharge upto 15 Cum/Hr at 14.5 Kg square cm pressure, SS-304 impeller vertical centrifugal pipe all inclusive of replacement of spare parts complete all as specified and directed by Engr-in-Charge.
M&L for repair to Raw water pressure pump of rating upto 20 HP of discharge upto 15 Cum/Hr at 14.5 Kg square cm pressure, SS-304 impeller vertical centrifugal pipe all inclusive of replacement of spare parts complete all as specified and directed by Engr-in-Charge. (Note for item No 48 to 49:- Old U/s parts demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill.)
M&L Preventive maintenance of electric motor driven Chlorine dosing system any make including cleaning of electrode rod, HDPE/FRP tank of capacity up to 150 Ltr tank and checking functionality and performance of level gauge, Dosing pump, High pressure single head gear motor, pressure gauge, power pack including oiling and greasing of all moving parts complete all as specified and directed by Engr-in-Charge. (Note : Spare Parts required for replacement in maintenance work will be measured & paid separately).
M&L of Opening the motor of capacity 0.5HP, rewinding the motor with super enammeled copper wire of existing gauge,weight etc, reparing the same by replacing the unserviceable spare parts and re-assembling the motor in orignal position to make it functional complete all as specified and as directed. (Note:- (i) Old U/s copper winding wire shall be contractor's property and accordingly rate will be quoted by contractor against this item. (ii) New / fresh super enamelled copper winding wire will be deemed included in quoted unit rate.)
Supply Only of Gear Motor 230 volt 50 Hz suitable for decrin dosing pump Part No PM 682 CE complete all as specified and as directed.
Supply only of Rotor assembly with bearing brackets and tolerance rings Part No PMBR PL2 complete all as specified and as directed.
Supply only of Coil 250 volt, 50Hz Part No. MP 6 J222 complete all as specified and as directed.
Supply only of Single head feed rate control with shaft Part No FC 5040D complete all as specified and as directed.
Supply only of Pump head (Ferrules 1/4" including duckbill) Part No UCPH 7 FD complete all as specified and as directed.
Supply only of Roller assembly Part No. MC3ASYD complete all as specified and as directed.
Supply only of Pump tube Part No MCCP 207 complete all as specified and as directed.
Supply only of Injection check valve 3/8" Part No MCINJ 38 complete all as specified and as directed.
Supply only of Weighted suction line strainer 3/8" Part No. ST 138 complete all as specified and as directed.
Supply only of White suction/discharge tube Part No. MAL T002 complete all as specified and as directed.
Supply only of chloroscope for water testing range of 0.1 ppm to 2.0 ppm complete all as specified and as directed.
Supply only of ORTO-TOLUDINE regent solution in 500 ml bottle complete all as specified and as directed.
Supply only of first Aid kit (PVC container) as per the specification including first aid medical treatment materials complete all as specified and as directed. Make: Standard or equivalent make approved by the Engr-in-charge (Note : All the medicine and First Aid will be of latest date and should be having atlest 12 months expiry date from the date of actual supply)
Supply only Knob of speed/stroke complete all as specified and directed.
Supply only main indicator lamp assembly complete all as specified and as directed.
Supply only valve seat cap of suction/discharge complete.
Supply only fixing bolts made of stainless steel or supplied by OEM only complete all as specified and as directed.
Supply only main indicator lamp assembly complete all as specified and as directed.
Supply only Diaphragm seal complete all as specified and as directed.
Supply only Diaphragm complete all as specified and as directed.
Supply only Shaft(Diaphragm) complete all as specified and as directed.
Supply only strainer only(Foot valve) complete all as specified and as directed.
Supply only Pipe(Discharge/suction) of OEM recommended make complete all as specified and as directed.
Supply only Foot valve assembly as per sample (complete with ball,seal &spring) complete all as specified and as directed.
Supply only pulser circuits & speed potentiometer complete all as specified and as directed.
Supply only power transformer of OEM recommended make complete all as specified and as directed.
Supply only fuse assembly including fuse complete all as specified and as directed.
Supply and fixing in replacement of antisyphon valves (complete with ball, seal & Spring) complete all as specified and as directed. (Note for ser item No 52 to 79 :- Old U/s PVC & iron scrap demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply and fixing in replacement of FRP construction solution preparations cum settling Tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 100 Ltr complete all as specified and directed.
Supply and fixing in replacement of FRP construction solution preparations cum settling Tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 150 Ltr complete all as specified and directed.
Supply only of PVC/Rubber Hand glove suitable for handling of liquid Chlorine ISI marked complete all as specified and directed. (Note for ser item No 80 to 82 :- Old U/s FRP Tank demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in PVC scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
Excavation in trenches not exc 1.5 metres wide and not exc1.5 metres deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required level all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick all as specified and directed by Eng. In Charge
Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point as directed by Engr-in-Charge.
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-2 (with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface all as specified and directed.
Taking out old unserviceable LT cable of any size/make from trenches/wall/ducts/roof complete all as specified and directed by Engr-in-Charge. (Note:- (i) Old U/s aluminium LT cable demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of aluminium scrap in (KG) shall be taken into account and attach with RAR/F Bill. (ii) Excavation & earth work, sand cushioning & brick protection shall be measured and paid seperately under respective items.)
Supply, laying, testing & commissioning of LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade & laid in trenches/pipes or fixed on pole including of the following sizes:-
16 Sqmm x 4 Core
25 Sqmm x 3.5 Core
35 Sqmm x 3.5 Core
50 Sqmm x 3.5 Core
70 Sqmm x 3.5 Core
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches/ducts. (Note :- Punning thickness shall be measured & paid.)
M&L for laying of brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as speicifed and directed.
Supply and laying of galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore complete all as speicifed and directed.
M&L for taking out old and broken PCC pole of any size/height from the existing size by breaking the foundation and dismantlimg the cable connections complete all as specified and directed by Engr-in-Charge.
Excavating in post holes each not exceeding 0.5 cum in soft / loose soil, getting out, returning filling in and ramming earth or broken rubble mixed with around earth in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50 metre and making good surface
Supply and fix in replacement, errecting of steel tubular poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. (Note: (i) Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. (ii) Old unserviceable steel pole shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations filling mass concrete bed of pipe etc complete all as specified and directed by Engr-in-Charge.
M&L PCC (1:2:4) type B-1 using 20mm graded crushed sotne aggregate as in coping bed plate including weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement 60 watt LED street light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. (Note:- Old U/s GI pipe brackets demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply and fixing in replacement 90 watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. (Note:- Old U/s GI pipe brackets demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply and fixing in replacement 120 watt LED flood light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. (Note:- Old U/s GI pipe brackets demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply and fixing of poly carbonate junction box , weather and vermin proof of suitable size in replacement including provn of 2 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators , including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, earthing bolt, double washer and galvanised flat iron clamps of suitable size for taking connections and fixing on LT steel tubular poles complete with locking arrangement complete including cable gland of suitable size at entry and exit point of cable complete all as specified and directed. Note: (i) Box shall be provided at 1 metre above the pedastal of pole. (ii) Quoted rate shall be deemed to include bus bars, MCB and clamps. (iii) Old U/s aluminium bus bar & iron scrap clamp demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of (KG) shall be taken into account and attach with RAR/F Bill.)
M&L for carefully taking down old copper/aluminium point wiring (light, fan, bell,same board, independent or power) including complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surfaces of wall, floor & ceiling etc complete all as specified and directed. (Note :- Old u/s wiring copper / aluminium & fittings such as switch, socket, sunken boxes, ceiling rose etc.)
M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly for the following :-
(a) One light point controlled by one, one way switch .
(b) One Ceiling Fan/Exhaust fan point controlled by one, one way switch.
(C) One 3 pin socket outlet 5 Amps on the same board with other switches.
(d) One 3 pin socket outlet 5 Amps on the Independent board.
All as per item No- 103 here-in-before but power point with 2.5 Sq mm single core multi standard copper conductor FRLS type for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
Supply & fixing of Switch piano flush type single pole, one way 5A complete all as specified and directed.
Supply & fixing of Switch piano flush type single pole, one way 16 Amp complete all as specified and directed.
Supply & fixing of Socket outlet, 2 in 1, 3 pin 5A flush type complete all as specified and directed.
Supply & fixing of Socket outlet, 2 in 1, 5 pin 16A flush type complete all as specified and directed.
Supply & fixing of ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed.
S&F including testing & commissioning of Decorative ultra slim round profile LED lighting fixture 20W,6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed.
S&F of MCB Distribution 6 way, SPN, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
All as per item no 110 here in before but MCB DB SPN 8 way
S&F of MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
S&F of MCB SPN 40 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
S&F of MCB SP 6-32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed. (Note for ser item No 109 to 114 :- Old U/s MCB & light fitting demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in (KG) shall be taken into account and attach with RAR/F Bill.)
Supply and fixing of metal body in replacement exhaust Fan, heavy Duty 450 mm sweep, 1400 RPM Single pole 230V , 50Hz complete all as specified
Supply and fixing of metal body in replacementceilling fan 1200 mm sweep Single pole 230V , 50Hz complete with fan regulator and down rod connection complete all as specified and directed. (Note for ser item No 115 to 116 :- Old exhaust fan metal body & ceiling fan with down rod shall be deposited in MES store yard at contractor's own arrangement.)
S&F in replacement new generation post-top Gate Light, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source 25W, 5700K complete with provision and fixing of GI pipe with necessary civil works involved complete all as specified and directed.
Supply and fixing in replacement of LED Solar street light fitting 20 Watt with 24month warranty including providing 80mm dia galvanized steel pole 6 meter height heavy duty with in built lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Note:- Excavation & earth work PCC subbase (1:4:8) block shall be deemed included in quoted unit rate.)
Supply and fixing of LED Panel light 36W environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed. (Note for ser item No 117 to 119 :- Old steel iron pipe bracket & pole shall be taken on charge in 'KG' in demolition ledger / salvage register and shown in demolotion statement.)
CHOUDHARY ELECTRICAL (BID ID -3279197)
PRASAD ELECTRICALS (BID ID -3283808)
Surjit and Sons (BID ID -3278898)
GE WORLD (BID ID -3278883)
Deven Associates (BID ID -3283937)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .