| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹51.0 L+₹1.8 L (3.65%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹51.8 L+₹2.6 L (5.25%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹52.2 L+₹3.0 L (6.06%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹53.3 L+₹4.2 L (8.46%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
6 Oct 2020, 6:55 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR REPLACEMENT OF SUBMAIN WIRING, MAIN DB S ENERGY METER UNSV MCB S BLDG EARTHING AND OTHER MISC E M WORKS AT AF STN SULUR
2020_MES_378125_1
8359
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
26 Oct 2020
16 Sept 2020
7 Oct 2020
16 Sept 2020
6 Oct 2020
30 Sept 2020
16 Sept 2020 - 29 Sept 2020
Amount
SCHEDULE A BOQ
Material and Labour for Insulation resistance testing of internal electric wiring in administrative, technical building and building containing explosives all as specified here under and as directed by Engineer-in-Charge :-
(a) The resistance of the earth continuity conductor shall be tested between the main switch and any part of the wiring outlet.
(b) The insulation resistance between conductors.
(c) The insulation resistance between conductors and earth lead at main switch.
(d) Earth resistance of each electrode point by detaching the earth continuity conductor (ECC) at test point or ECC detached from main switch .
(e) All above testing are to be done in accordance with IS-732-1963 and results are to be recorded in a prescribed format for following :-
Single phase sub main outlet
Three phase four wire sub main outlet
DB contains single phase circuit not exceeding 2 circuits
DB contains single phase circuit exceeding 4 circuits and not exceeding 6 circuits
DB contains single phase circuit exceeding 8 circuits and not exceeding 10 circuits
DB contains three phase 4 wire circuit outlet
Earth resistance test of individual earth points as specified in Srl No.6 (d) above.
Note :- (i) The contractor shall arrange necessary testing instruments of suitable range and cost for the same shall deem to be included in the quoted rate.
(ii) Test to be conducted in the presence of MES rep and concerned users.
(iii) In case, any minor defect found at the site, same shall be rectified by using suitable size of nut, bolts, washer etc.
(iv) Any major item require to rectify the defect shall be measured and paid separately.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 6 sqmm cable along with two run of 4 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size and all as specified. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Factory made powder coated distribution board SP & N 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and conforming to IS: 8623 . Make/Model : Cat No 607711 of Legrand or equivalent of Schnieder & L & T .
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/Schnieder / Legrand
Distribution board MCCB four pole, 125 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 including taking down old one complete all as specified. Make : Legrand Cat No 420016 or equivalent in Schnieder or L & T.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). Make of Cable : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No. 25 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 or equivalent in Siemens/ Schnieder.
S&F IP 66 LED bulkhead luminaire, consuming a power of 9W. Lumen output not less than 800 lumens with a system efficacy > 115 lm/W, translucent UV stabilised poly carbonate anti-glare diffuser, colour temp not less than 6500K, PF > 0.95 shall have 50,000 burning hours as per L70 criteria, with surge protection device minimum 2KV, LED driver with constant output voltage and current at input voltage of 110 Volt to 270 Volt AC at 50 Hz,. The bulkhead body base should have inbuilt provision for easy mounting on wall/ ceiling with PVC insulated copper conductor 3 core cable of 0.5 sqmm. The body of luminaire should be dust, water and all weather proof for out side mounting . The luminaire shall be BIS certified. Make :- Philips/ Bajaj/ CG Notes:- 1. The Contractor shall submit test report from manufacturer of LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item. 2. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 3. The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Electronic energy meter 3 Phase 30 to 60Amps range capacity with SCADA compatibility port . Make : BENTEC / L&T/ABB Note : Old electric Meter shall be deposited to E/M store yard.
Bed side light 2W LED grey, PF˃ 0.9, CRI not less than 80 including taking down existing one all as directed . Makes Philips model No. 30975 or equivlent in Bajaj or CG
Excavation in trenches not exceeding 1.5m depth and not exceeding 1.5 mtr in wide in hard/dense soil and getting out.
Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 sq mm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
Distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 including taking down old one complete all as specified. Make : Legrand Cat No 420015 or equivalent of Schnieder or L & T.
Factory made powder coated distribution board SP & N 12 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar including taking down old one complete all as specified and conforming to IS: 8623 . Make/Model : Cat No 607712 of Legrand or equivalent of Schnieder or L&T
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land including taking down existing one all as specified and directed by Engineer-in-Charge. Make / Model of Light fitting : Athena 2 Prismatic of Havells Cat Part No : LHDC12115099 or equivalent in Wipro or CG.
Replacement of convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no. LBLSN-10-CDL or Bajaj Cat Part No. BGBOS 600 9W LED /philips.
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately.
(c) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(d) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(e) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Galvanised Earth Strip of size 25x6mm as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 61 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 61 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 61 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Modi/ Presto Plast/ Polycab Make of Wire : Plaza/ Polycab/ Havells Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 66 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 66 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 66 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted; Test Certificate to be submitted; Certification : LM 79 for luminaire & LM 80 for LED source. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Electronic energy meter single Phase 5 to 30Amps range capacity with SCADA compatibility port. Make : BENTEC / L&T/ABB Note : Old electric Meter shall be deposited to E/M store yard.
Supply and fix in replacement pole/ wall LED Flood Light luminaire of capacity 160 Watt,system lumen efficacy not less than 90 lumen per watt, total system lumens not less than 16000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV, colour temp 5700 k to 6500k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,luminaire IP 65 Class -I all as specified and directedMake : Bajaj Cat No. 169642 BARFEG 160W LED or Equivalent of Philips Cat Part No : BVP 410 LED 172 CW HE MB FG S3 XT/ wipro. Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 16 sqmm to 35 sqmm Make : Reychems, Densons, M Seal
S&F in replacement factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Legrand / Schnieder /siemens
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make : Philips Cat Part No BN308 LED20S 6500 L120 PSU WH or equivalent in Bajaj or wipro
Note for item No 79 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Wire : Plaza/ Polycab/ Havells Make of Casing Capping : Polycab/Modi/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 81 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 81 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 81 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Avon Plast/ Supreme/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No.86 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 86 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 86 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Shuttered socket outlet 3 pin 5 amps, flush type
Shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Supply only modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix bell push, flush type
Supply and Fix bell push, modular type, 1 way
Supply and Fix ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked.
Supply and Fixing lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply and Fixing electronic fan regulator modular type 230 volts, step type socket type, hum free 100/240 watt Make : Havells / Schnieder/crabtree
Supply and Fixing Electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt. Make : Havells / Schnieder/ crabtree
Supply and Fixing electric bell Ding Dong , AC 230 volt, single pole complete all as specified and directed. Make : Anchor/ cona/ Plaza
S&F in replacement of all in one integrated solar street light of less than 18W with 3000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70. Make : Philips Cat No BRP 710 LED 30 CW MR HY FDIM 50 SOLAR or equivalent in Wipro/ Bajaj.
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long MS/ GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 including taking down old one complete all as specified. Make : Legrand Cat No 420013 or equivalent of Schnieder or L & T
High power LED street light fittings energy saving luminaire with lens , capacity 20 watt with system efficacy (lm/w) not less than 90 lumens per watt, total system lumen not less than 2000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K TO 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specified.. Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent in Bajaj/Wipro.
Note :- (a) The contractor shall submit to Engineer-in-Charge photo Biological safety Norms as per IS 16108. (b) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (c) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (d) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (e) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Replacement of convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.Make/cat part No. CG cat no. LPTO-40-CDL or Bajaj Cat Part No. BRIL 45 W LED NW /philips.
Supply and fix in replacement of high power LED street light fittings energy saving luminaire with lens , capacity 36 watt with system efficacy (lm/w) shall be 100 lumen per watt or more lumens per watt, total system lumen not less than 3600 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specified.. Make : Philips Cat No. BRP409 LED CW 036 MR FG S1 PSU GR or Equivalent of Bajaj/Wipro. Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. Make : Model HTSP 3I7 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply, install, testing and commissioning of energy conversion digital grounding apparatus three phase 4 wire 240 KA with inbuilt 100% lighting surge protection, noises, ESD, EPR and abnormal electrical characteristics which enter power and other service lines and ensuring clear bonding potential (Earth to neutral voltage) less than 1.0 volt to be connected in parallel to the circuit, conforming to IE, tested and certified as per latest certification (IEC 61643-1, IEC-61000-4-5, IEC-61000-6-1, IEC-61000-6-3, MIL-STD-810-G, ISO 14001-2004) in prewired metal enclosure with pulverulent body painting all accessories required for installation etc complete all as specified and as directed. Make : Ground Co ltd Model No eca 3 G LP-34-40 or its equivalent as approved by GE
T C KARUNANITHI
rvelectricals
NAVEEN ENTERPRISES
KUMAR AGENCIES
SUPER COOL
Lucky Enterprises
Neptune Engineers and Builders
devan enterprises
A.GOVINDARAJ
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .