Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹37.2 L+₹71,635 (1.96%)Rejected-AOC NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹37.7 L+₹1.2 L (3.25%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹38.1 L+₹1.6 L (4.44%)Rejected-Finance | L4 | Rejected-Finance Being L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
7 Oct 2019, 1:00 pmClosed
Exe Eng,Birbhum Elec Divn.
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Electrical Installation work of CMOH office at Rampurhat Health District, Birbhum.....SITC of AC Machine, SITC of D.G set and Glow Sign Board and allied EI work from balanced work.
2019_WBPWD_244787_1
BIRED/11/e-Q (1st call) of 2019-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
CMOH, Rampurhat
Please refer Tender documents.
8 documents required · 8 mandatory
₹73,000
Yes
office of the Exe. Eng,PWD,Birbhum Elec Divn
8 Jan 2020
17 Sept 2019
16 Oct 2019
17 Sept 2019
7 Oct 2019
24 Sept 2019
24 Sept 2019
Amount
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2x(4 sqmm)+1x (2.5 sqmm)
4x(16 sqmm)+2x(10 sqmm)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5 sq.mm [9i/F-5]
4 sq.mm [9ii/F-5]
10 sq.mm [9iv/F-5]
16 sq.mm [9v/F-5]
Supplying and fixing 6 Way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) [ 14 / D- 10 ]
Supplying and fixing 63 A FP, 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ]
Supplying and fixing 415V, 250A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc(L&T Make)
S &F AC machine timer DB for one no. Single phase split type machine febricated with following item as per instruction of EIC. i) 240 V, 32A DP MCB of breaking capacity 10 kA & ''C'' Charecteristic ( L&T) ------ 1 no ii) 25A 2 Pole Power Contractor with 220V coil voltage ( L&T) (Cat no. MU25-2P )------ 1 no iii) Digital Timer Switch (L&T) ( Cat no - 67DDTO)----- 1 no iv) Toggle switch for manual/auto operation --- 1 no. v) Double door 2+8 Way SPNDB as per L&T ( cat no- LTSDO8N ) ----- 1 no vi) Necessary connection by copper wire.
S &F AC machine timer DB for Two no. Single phase split type machine febricated with following item as per instruction of EIC. i) 240 V, 32A DP MCB of breaking capacity 10 kA & ''C'' Charecteristic ( L&T) ------ 1 no ii) 25A 2 Pole Power Contractor with 220V coil voltage ( L&T) (Cat no. MU25-2P )------ 2 nos iii) Digital Timer Switch (L&T) ( Cat no - 67DDTO)----- 1 no iv) Toggle switch for manual/auto operation --- 1 no. v) Double door 2 +10 Way SPNDB as per L&T ( cat no- LTSD12N ) ----- 1 no vi) Necessary connection by copper wire.
Supply & Fixing 240 V, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 17 /E-19 ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) /E-17 ]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections [ 5(b) /E-17 ]
SITC of 2.0 TR split type room Air Conditiner (Cooling only) having the following specification & features.:- a) Cooling capacity (Maximum) (BTU /HR): 25248; Cooling Capacity (Rated) Guaranteed (BTU/HR): 24907; b) Star Rating -4 star; c) Rated Voltage-230 V + / -5%, Frequency -50 Hz; d) Compressor type- Rotary; e) Mini. Room Discharge Air Flow Rate-1300CMH; f) Refrigrant: R- 410A; g) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing h) Out door operating Temperature:- 50˚ C (Minimum). (Model: Indoor :- SRK24CSS-S6/A/Similar Model, Out door :- SRC24CSS -S6/A /Similar Model) (Make: Mitsubishi Heavy/Daikin/O-General or As per choice of EIC) With 15A plug top, 2mt long input cord , & all other installation kit 3mtr 15.88mm&6.35mm mm copper pipe with keno foam insulation for indoor to out door unit connection , out door unit will be fixed on wall with heavy type wall base.Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor.
SITC of 2.2TR split type room Air Conditiner (Cooling only) having the following specification & features.:- a) Cooling capacity (Maximum) (BTU /HR): 26272; Cooling Capacity (Rated) Guaranteed (BTU/HR): 26017; b) Star Rating -5 star; c) Rated Voltage-230 V + / -5%, Frequency -50 Hz; d) Compressor type- Rotary; e) Mini. Room Discharge Air Flow Rate-1450CMH; f) Refrigrant: R- 410A; g) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing h) Out door operating Temperature:- 50˚ C (Minimum). (Model: Indoor :- SRK25CSS-S6/A/Similar Model, Out door :- SRC25CSS -S6/A /Similar Model) (Make: Mitsubishi Heavy/Daikin/O-General or As per choice of EIC) With 15A plug top, 2mt long input cord , & all other installation kit 3mtr 15.88mm&6.35mm copper pipe with keno foam insulation for indoor to out door unit connection , out door unit will be fixed on wall with heavy type wall base.Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor.
SITC of 1.6 TR split type room Air Conditiner (Cooling only) having the following specification & features.:- a) Cooling capacity (Maximum) (BTU /HR): 21000; Cooling Capacity (Rated) Guaranteed (BTU/HR): 18083; b) Star Rating -5 star; c) Rated Voltage-230 V + / -5%, Frequency -50 Hz; d) Compressor type- Rotary; e) Mini. Room Discharge Air Flow Rate-1100 CMH; f) Refrigrant: R- 410A; g) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing h) Out door operating Temperature:- 50˚ C (Minimum). (Model: Indoor :- SRK20CSS-S6/A/Similar Model, Out door :- SRC20CSS -S6/A /Similar Model) (Make: Mitsubishi Heavy/Daikin/O-General or As per choice of EIC) With 15A plug top, 2mt long input cord , & all other installation kit 3mtr 15.88mm&6.35mm copper pipe with keno foam insulation for indoor to out door unit connection , out door unit will be fixed on wall with heavy type wall base.Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor.
Supply & fixing of 18mm & 8mm heavy guage copper pipe line from indoor unit to outdoor unit including of keno foam insulation of electrical line from indoor unit to outdoor with 4 x 2.5sqmm copper wire cable.
Supply & fixing 19mm dia nylon reinforced PVC pipe for Drain out the water from cooling unit as per instruction of EIC.
Supplying and fixing 4 way, double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(Up to 250A)
Supplying and fixing 80 A, 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs /enclosure and necessary connection
Supplying and fixing 63 A TP, 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 4x126/0.4 (25 sqmm) + 2x80/0.4 (10 sqmm) as ECC. [E-9/1e1]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
25sqmm NS
16 sqmm [ 9 (v) / F- 5 ]
Designing, fabrication, supply, installation, testing & commissioning of outdoor type LED sinage (approx. size 10 ft X 6ft*2 = 120 sqft ) in Bengali or English (Letter given and approved by concerned Authority) for letter with following specification.(For Treasary office and SDO office) including Iron Structure for Installation of LED Sign Board
a) The box for sinage will be fabricated in all aluminium square tube of size of 25mm x 25mm 16 SWG gauge complete with necy. Priming & painting. The front of the box will be covered with 3 mm thick Al. composite Panel (ACP) sheet of the entire board. The board to be fixed in front of canopy by providing required support & angle bracketing. The composite installation will be water, vermin and dust insulated and protected.
b) Letter description approx. 30" x 15" size of letter made of acrylic sheet with male female attachment on router cut ACP sheet of front incl. all accessories as required.
c) LED illuminition High Bright wave length closed type water proof white LED module (1.2 W) mounted on interior side of female part of letter with power wire running back to central power area with 12V LED power transformer to adequately drive the whole LED module with flicker.
d) Internal electrical wiring will be done by Halogen free frame retardent HRFR compound insulated (unsheathed) 3 core 1.5 sq.mm copper flexible cable as required through interior conduit and electrical raceway.
Supply of 2 Core 10 Sq. mm 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Fort Gloster]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [2(a)/F-1]
Supplying and fixing compression type gland and finishing those for 2 Core 10 Sq. mm Core XLPE / PVC armoured cable as per GS. [7(c)/F4 & 8(b) /F5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 100 x 100 x 65 [11(a)/E-4]
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 100 x 100 x 65 [12(a)/E-4]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [1(b) / E- 9 ]
Supply & Delivery of new CPCB-II compliant 415V 160KVA/128KW 50 Hz 3 Ph P.F. 0.8 ( lag ) compromising of engine, Alternator, STD AMF panel, base frame, Fuel tank, Battery, CPCB approved acoustic enclosure including all inter connection between generator & panel etc. Engine should not derate to 50 deg C ambient temparature having following specification. ( Make- Jackson / VOLVO Group / FG willson / Ashok Leyland / Catterpiler/Cummins/ Mahindra / As per choice of EIC )
ENGINE- a) Make- Jackson / VOLVO Group / FG willson / Ashok Leyland / Catterpiler/Cummins/ Mahindra / As per choice of EIC b) MOEF certified power- min. 175 BHP, 6 Cylinder/EQ c) Aspiration - Turbocharged- Air cooled ( TCA ) d) No. of strke - 4 e) RPM- 1500 f) Battery- 1 x 12V, 180 AH Dry ( As per standard of OEM ) g) Type of cooling- Liquied cooled ( EG compleat 50:50 ) Radiator cooled with engine water pump and coolant along with first fill of coolant. h) Air intake system- Air intake manifold with dry type air filter system and vacuum indicator.
i) Exhaust system- provided with turbo charger and residential exhaust silencer with manifold flexible below and companion flanges. j) Coupling and fly wheel- coupling fly wheel and fly wheel housing. k) Lubricating system - Provided with oil pan, engine mounted lube oil pump and full flow lube oil filter, lube oil bypass filter along with first fill of lube oil. l)Fuel system- Comprising of fuel pump with Electronic Governor, fuel ionjector, 12V solenoid coil and replaceable fuel filter. m) Starting system- 2x12V DC electric starter and battery charging alternator. n) Safety control- Comprising of protection against- low lube oil pressure trip, High water temparature trip,High/Low Dc voltage trip, weak battery trip and over speed trip.
o) Power start control- provided with Micro processor based generator set monitoring and control system with LCD display designed to meet the demand of that's engine driven generator sets intuitive operator interface which includes LED backlight, LCD display with tactile feel softswitchs & generator set status LED lamps. Digital AVR shunt or PMG excitation with torque matching. Digital electronic governing with temparature compensation and smart starting. SAE J 1939 interface to Full Authority Electronic PAE Engine. Remote start stop.
Engine metering - Oil pressure, Coolant temparature,battery Voltage, Engine Speed. SE Alternator metering : L-L Voltage and L-N Voltage, Current (1 and 3 phase), Volt-amperes ( Phase and total ) and frequency. Engine Protection : Low lube oil pressure, High/Low coolent temparature, over speed, battery over/under/weak volts, Fall to crank/start, sensor failure. AC Alternator Protection : Over/Under voltage, Over/Under frequency, Over current, Short Circuit and loss of AC sensing.
Data logging:Engine hours,control hours,engine starts and upto 10 recent fault codes.Configurable glow plug control.configurable cycle cranking.12 and 24 v DC operation.Sleep Mode.programmable I/Os (4 inputes and outputes),expendable with AUX 101/102 modules. Modbus interface (RS85 RTU). In power Compatible (PC based service tool). Certification- Meets the requirement of relevant UL,NFPA,ISO,Mil,Std,CE and CSA standards.
i)Start/Stop key switch ii)Lube oil pressure indication iii)Water temperature indication iv)RPM indication v)Engine running indication vi)Low lube oil trip indication vii)High water temperature trip indication viii)Over speed indication ix)Battery charging indication,weak battery indication x)High/Low DC voltage xi) LED lamp indication for genset running remote start,shut down,warning,manual,auto & stop xii)Data log includes engine run time & controller on time xiii)Engine data display arrangement- Starting batter voltage,Engine running hour,Engine temperature & Engine oil pressure.
Alternator Make- Stamford /As per choice of EIC Rating- 160 KVA at 8 pf(lag) - 3 phase , 450V- 4 wire system. Voltage regulator - ± 1.0 %(max) in static condition. Brushless type screen protected,revolving field,safe excited alternator conforming to IS/IEC 60034 -1. 3Phase reconnectable winding with 12 terminals brought out for connection,Better motor starting capability,Best in class efficiency,Compact design with sealed bearings for longer life and lesser maintenance,Impregnation on all wound components for better mechanical strength type of alternator-Brushless,self excited and self regulated through AVR. Protection-IP-23 prtection with class H insulation having protection for under voltage,over voltage,over current,under/over frequency,loss of sensing,field overload,Over load-Permissible over load of 10% for one hour in 12 hours of operation. Metering Three phase voltage(L-L and L-N), three phase current,frequency,power factor KW Meter - with indicating lamp for load on & set running.
E. BASE FRAME : Containing the Engine and alternator mounted through AVM pads,on a common MS channel fabricated Base Frame,primer coated & painted with per - drilled holes. 5.. Fule Tank-Capacity 450 Lts.(or such a capacity that minimum 8 hours operation on full load) Made of 14 SWG sheet metal built inside base fame complete with drain valve, air vent, inlet and out let connection,fuel gauge. 6.. Acoustic enclosure- High quality Sound proof,wrather proof environmental friendly acoustic encloser fabricated from 14 SWG sheet steel & powder coated specially design to meet up CPCB - II standards to make noise level below prescribed limit ( 75 dB at distance of 1 meter from acquistic encloser under free field condition with hinged gasketted doors with suitable locking arrangement. 11 tank pretreatment process and UV resistent powdercoating of all parts to withstand extreme environment.
Making base for DG set with Brick wall (10inch brick work) 1mt bellow from GL & 900mm above GL. Of size. 6mt x 4mt with 3 inch thick CC (6:3:1) foundation below the wall and filling sand from ground level to top of wall and brick soling on top of size 6mt x 4mt and above brick soling 5 inch thick CC (6:3:1) foundation of size 6mt x 4mt incl. 3mm thick neat cement finish on all four sides & top of base as per instruction of EIC.
S & F exhaust pipe of 150 mm dia MS black pipe ( thickness 3mm) including connection with theexisting silincer attached with the flexible coupler and S & F flange,nut bolts & washer etc and necessary fixing materials etc. As required from 250 KVA DG set to nearest building with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangment and covering with alluminium clading for the following sizes of MS pipe/silencer as per direction of EIC.
a) 150mm dia exhaust pipe
b) Residential type silencer pipe
S & F rain protection canopy as per direction of EIC.
Supply & Delivery of 210 Ltr. Capacity heavy guage MS sheet bareel as per instruction of EIC.
Supply , transportation & pouring of HSD oil
Supply , transportation & pouring of Mobil oil
Supply & Delivery of best quality oil hand pump with 1'' dia PVC flxible pipe ( 12 mtr approx)
S & F straining 8mm dia. Steel stay wire rope including both side thimble bending with suitable size MS clamp. ( 8 mtr long approx ) long rope fixing on the top of 150mm dia. Black pipe on the building.
S & F of ducting for releasing the hot air from the DG Set to out side of the room. Ducting should be made by angle iron structure and covered by alluminium steel.
Supply of 2/4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Fort Gloster] 4 Core 185 Sq. mm [ NS ]
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed [1 (b)/F-2]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 185 Sq. mm [7(c)/F4 & 8(b(xvii) /F5]
Excavation of soil for installation of Earth Electrode and filling & ramming. [For Morrum Soil]
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level TATA-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F 25 X 6 mm GI (Hot Dip) flat iron on wall/floor with staples buried inside wall/floor as required and making connection to
Terms and conditions:- 1. Rates should be quoted in words as well as in figures Inclusive of all taxes, duties and delivery charges. 2. Manufacturer’s Test Certificate should be produced During delivery/ Commissioning. 3. All materials, equipments and accessories for the Genset must be as per the latest relevant I.S.S. 4. All equipments must be warranted for a period of 12(Twelve) months from the date of commissioning. 5. Price variation clause will not be accepted. 6. Terms of payment:- as per PWD norms. . 7. Conditional offer specially in deviation to the above clauses is liable to cancellation.
NOTE: 1.The Agency must procure the materials from the manufacture /OEM or from their authorised sales channel so that the standard warranty/support of the manufacture /OEM becomes applicable to the products to be delivered and installed by them 2.Documents that authenticates such procurement from the manufacture /OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture /OEM /authorised sales channel to the e mail of Engineer -in charge and hard copy of it to be submitted during execution of work/submission of Bill. 3. If any refurbished material is supplied and installed , Panel action will be will be takena as per existing rules. 4. 12% GST and 1% labour wellfare cess will be deduct from the bill.
MOON LIGHT
MODERN ENGINEERING ENTERPRISE
RIK ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .