| 1 | L1₹14.2 LAccepted-AOC 02 SIDDHANT RESIDENCY NEAR AMBAD POLICE STATION SINHASTHA NAGAR CIDCO NASHIK MAHARASHTRA 422009 UDYAM MH 23 0069304 | NASHIK | MAHARASHTRA | 422009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.1 L+₹3.6 L (25.2%)Rejected-Finance HARIPUSHPA APARTMENT BUILDING NO E 1 FLAT NO 01 REST CAMP ROAD DEOLALI CAMP 422 401 | DEOLALI CAMP | NASHIK | MAHARASHTRA | 422401 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹20.1 L+₹5.6 L (38.3%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹21.9 L+₹7.4 L (51.1%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
REPAAIR REPLACEMENT AND MAINT OF EXTERNAL WATER SUPPLY AND CONNECTED ITEMS AT AIR FORCE STATION DEOLALI
2021_MES_496816_1
8837/E8
Open Tender
Civil Works
Item Rate
335 days
DEOLALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹40,000
Yes
23 Feb 2022
23 Dec 2021
27 Jan 2022
24 Dec 2021
25 Jan 2022
13 Jan 2022
60 days
Amount
Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr depth in any type of soil (soft/loose/hard/dense soil) for laying / taiking up/ taking down of water pipes of any size and type including levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge
All as per item No. 1 above but in hard/dense soill.
Returning filling in trenches including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material from site to a distance n. exc. 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr avove the starting point all as specified and directed by Engineer-in-Charge.
Taking up or down galvanised steel tubing and connections including cleaning for refixing or removal for 15mm bore
All as per item No. 5 above but 20mm bore
All as per item No. 5 above but 25mm bore
All as per item No. 5 above but 40mm bore
All as per item No. 5 above but 50mm bore
Supply and lay galvanised steel water tubing medium grade including all fittings such as bends, elbows, tees, reducers, sockets, union etc and laid in trenches complete all as specified and drected of 15mm bore Note : Excavation & earthwork will be measured & paid sperately
All as per item No. 10 above but 20mm bore
All as per item No. 10 above but 25mm bore
All as per item No. 10 above but 40mm bore
All as per item No. 10 above but 50mm bore
Supply and fix galvanised steel water tubing medium grade including all fittings such as bends, elbows, tees, reducers, sockets, union etc and laid in floor fixed on wall and ceiling complete all as specified and drected of 15 bore.
All as per item No. 15 above but 20mm bore
All as per item No. 15 above but 25mm bore
Material and labour for Cutting and screwing existing steel tubing or alterations or additions of 15mm
All as per item No. 18 above but 20mm bore
All as per item No. 18 above but 25mm bore
All as per item No. 18 above but 40 or 50 mm bore
S&F Bib taps, standard of PTMT any colour high pressure screwed for iron pipe and fixed to 15 mm bore pipe.
Supply and Fix for GI Nut nipple 15 mm for day to day complaints
All as per item No. 23 above but GI Nut nipple 20 mm
All as per item No. 23 above but GI Nut nipple 25 mm
All as per item No. 23 above but GI Barel nipple 15 mm 6 inches long both end screwed
All as per item No. 23 above but GI Barel nipple 15 mm 4 inches long. both end screwed
GI Barel nipple 20 mm 6 inches long. both end screwed
All as per item No. 23 above but GI Barel nipple 20 mm 4 inches long both end screwed
All as per item No. 23 above but GI Barel nipple 25 mm 6 inches long both end screwed
All as per item No. 23 above butGI Barel nipple 25 mm 4 inches long both end screwed
All as per item No. 23 above butGI screwed Plug 15 mm
All as per item No. 23 above but GI screwed Plug 20 mm
All as per item No. 23 above but GI screwed Plug 25 mm
All as per item No. 23 above but Union GI 50 mm
All as per item No. 23 above but Union GI 40 mm
All as per item No. 23 above but Union GI 25 mm
All as per item No. 23 above but Union GI 20 mm
All as per item No. 23 above but Union GI 15 mm
Taking up cast iron water main (including all fittings, with spigot, and socket ends and lead joints including burning out joints and recovering lead for the100 mm bore of pipe
All as per item No. 40 above but 150 mm bore of pipe
All as per item No. 40 above but 250 mm bore of pipe
Supply, laying, jointing and testing cast iron pipes with spigot and socket ends cetrifugally cast class LA in any length, suitable for tyton joint, laid in trenches for the 100 mm bore of pipe all as specified and directed
All as per item No. 43 above but 150 mm bore of pipe
All as per item No. 43 above but 250 mm bore of pipe
Supply,laying, jointing and testing Ductile iron (DI) pipes with spigot and socket ends cetrifugally cast class K 9 in any length, and including suitable tyton joint, laid in trenches & walls as per site requirment for the 100 mm bore of pipe all as specigied and directed Note : Rates are included for rubber gaskets for jointing DI pipe of 100 mm dia.
All as per item No. 46 above but 150 mm bore of pipe
All as per item No. 46 above but 250 mm bore of pipe
M&L for jointing cast iron/DI pipe spigot and socket and fittings with run lead joint complete all as specified and directed by Engr-in-charge for 80 mm bore of pipe.
All as per item No. 49 above but 100 mm bore of pipe
All as per item No. 49 above but 150 mm bore of pipe
All as per item No. 49 above but 250 mm bore of pipe
M&L for CI Bends (any type, radius and angle) tappers any type,(straight, bend, increasing, decreasing, or double socket etc). Tee pieces, single branch, Y junction double branch, cross (all socket or socket and spigot) collars, caps, caps, and plugs) upto 150 mm bore of pipe .
Supply and Fix Gun metal gate valve, ISI marked, with iron wheel head screwed both ends for iron pipe, fixed in repairs complete of the 15mm bore
All as per item No. 54 above but 20mm bore
All as per item No. 54 above but 25mm bore
All as per item No. 54 above but 40mm bore
All as per item No. 54 above but 50mm bore
S&F in repair Sluice valve with flanged ends cast iron body flanged and drilled for sizes as per IS- 14846 hand wheel operated, stainless steel stem with gun metal parts including all joints with rubber for fibre board bolts nuts and washers, also including the necessary pre-drilled flange according to site condition for adjustment in existing pipes to fit the sluice valve tightly with stainless steel wedge nut and Brass spindle class PN 1.6 with operating wheel complete 80mm dia.
S&F in repair Sluice valve with flanged ends cast iron body flanged and drilled for sizes as per IS- 14846 including all joints with rubber for fibre board bolts nuts and washers, also including the necessary pre-drilled flange according to site condition for adjustment in existing pipes to fit the sluice valve tightly with stainless steel wedge nut and Brass spindle class PN 1.6 with operating wheel complete 100mm dia.
S&F in repair Sluice valve with flanged ends cast iron body flanged and drilled for sizes as per IS- 14846 including all joints with rubber for fibre board bolts nuts and washers, also including the necessary pre-drilled flange according to site condition for adjustment in existing pipes to fit the sluice valve tightly with stainless steel wedge nut and Brass spindle class PN 1.6 with operating wheel complete 150mm dia at any height in a vertical position on main raising pipe line at top of RCC OH Reservoir stagging 60 feet height or in any type of valve pit chammber complete including with providing a scaffolding on top at RCC OH tank as prevention to human safety complete as all directed .
S&F in repair Sluice valve with flanged ends cast iron body flanged and drilled for sizes as including all joints with rubber for fibre board bolts nuts and washers, also including the necessary pre-drilled flange according to site condition for adjustment in existing pipes to fit the sluice valve tightly with stainless steel wedge nut and Brass spindle class PN 1.6 with operating wheel complete 250 mm dia.
S&F in repair Cast iron Air Valves with two air Outlets, 150mm dia bore and fixing up in cast iron water supply mains.
S&F Rubber Gasket Packing for different sizes of Sluice/foot valves of 6 mm thickness and all as specified and directed by Engineer -in-charge .
M&L for Dismantling the old damaged valve chamber complete and removing the debries of demolished material to a distance not exc 50 mtr for disposal, cleaning the site and Construction of valve chamber of size 1200mm x 1200mm x1200mm internal dimensions complete of brick masonry of 23cm thick in cement mortar 1:6 on PCC 1:4:8 fountation 75 mm thick using 40 mm graded stone aggregate, coping in concrete 1:3:6 for 10 cm thick at the top of brick wall using 20 mm graded stone aggregate and 10 mm thick plastering in 1:4 cement mortar on exposed MS cover of 3.15 mm thickness including 40mm x40mm x6mm angle iron frame fixed with the same size of angle iron hold fast, handle with locking arrangement, two coats of synthetic enamel paint over coat of red oxide primer on steel surfaces and two coat of white wash on the plasterd / concrete surfaces. complete all as specified and directed.
All as per item No. 65 but for size 600 x 600 x 600.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 15 mm
M&L for Straight plain brass ferrules (or connecting screws ) screwed both ends and fixed to water mains for tapping branch connection of size 15 mm bore
M&L for cutting of grass, vegitation, bushes and small tree branches by manually or machine and depositing where dircted n exc 100 mtr away and cleaning the area in installation or along the pipe line complete all as directed.
M& Labour for Washing out overhead reservoir of capacity 1,25,000 gallons of 18 mtr stagging,removing of algae, cleaning the internal portions with mechanical scrappers wire brush, brooms etc cleaning internal portion with high pressure water jet and using pressure jet pumps. Cleaning with clear water and removing the sediments applying suitable bleaching powder solution. After washing clearly with clear water drying in open and applying two coats of white wash in containor portion compleate including incomming and outgoing pipes, wash out pipe etc complete all as directed by Engineer-in-Charge.
All as per item No 70 above but for capacity of 50,000 gallons capacity Note for Ser Item No 70 & 71 i) The rate quoted by the cotractor is deemed to be included the cost of staging, bleaching powder, wire brush, mechanical scrapper etc.ii) Contractor is responsible for sefty of his men while climbing on overhead tank and working inside. He is also resposible to provide the sefty equipment to the worker without any extra cost to the department. iii) The contractor is fully responsible for any blockege or depositing sludge to the delivery lines. He will rectify all such defects on his own expense. iv) Contractor is also responsible to write cleaned date on board with paint. v) Contractor shall inform in writing 10 days before for cleaning of over head reservoir.
Labour only to locate the any kind of fault in water pipe line GI/CI upto 80 mm dia and any type by digging only along the lenth of water pipe line and upto the depth of water pipe line bottom to locate the exact pin point location of fault including rectification of fault with the help of plumber, returning filling of same by tightening the union, replacing of elbows, sockets, tees, nipple, check nuts etc complete all as directed. Note: i) The excavation beyond the length of 2 mtr along the pipe line shall be consider complete excavation in trenches and measured under the respective items of excvation of this shedule. ii) The items required to replace shall be measured and paid seperately under the relevent items of this schedule. iii) The quoted rate is deemed to be included the rate of Plumber & labour for digging.
Labour only to locate the any kind of fault in water pipe line CI/DI 80 mm to 250 mm dia and any type by digging only along the lenth of water pipe line and upto the depth of water pipe line bottom to locate the exact pin point location of fault including rectification & NOTE:-Contractor will submitt his registered Email ID within 15 days of acceptance to this office for intimating to complaint. b) Complaint or instruction not followed by the contractor will infrom by Email and contractor is libile to attained the same within 8Hrs after receiving the First mail. c) If contractor fails to attaind and rectify the complaint withing 8 Hrs he is liabale to penalty of Rs 200 per Hrs till the completeion/ rectification of complaint/ instruction. i) The quoted rate is deemed to be included the rate of Plumber & labour for digging ii) The excavation beyond the length of 4 mtr along the pipe line shall be consider complete excavation in trenches and measured under the respective items of excvation of this shedule
Supply and fix in repairs fully atutomatic star delta starter suitable to VT pumpset motor, 3 Phase, 415 volt 50 Hz, 20 HP capactiy with single phase prevention protection feature, timer, contactor of suitable capacity, relays for overload protection and short circuit complete, totaly enclosed in sheet metal enclouser and to be fix on wall including making connections to the motor complete all as directed.
M & L for mechanical joints CI/DI of dia 80 mm complete all as specified & as directed by Engineer-in-charge.
M & L for mechanical joints CI/DI of dia 100 mm complete all as specified & as directed by Engineer-in-charge.
M & L for mechanical joints for CI/DI pipe of dia 150mm complete all as specified & as directed by Engineer-in-charge.
M & L for mechanical joints CI/DI of dia 250mm complete all as specified & as directed by Engineer-in-charge.
supply and laying in repairs MS pipe of size 100mm heavy grade with MS flanged all fittings laid in floor or fixed to wall or at any height at top of RCC OH Reservoir stagging 60 feet height complete including with providing a scaffolding on top at RCC OH tank as prevention to human safety complete as all directed .
Material & labour for daily cleaning of storage water tanks 02 Nos of capacity 60000 Gallon each and sedimentation tanks 02 Nos of capacity 22x22x30 feet including drain out of water and complete removing sludge and funkage with wire brush and back wash both the filter bed daily at filtration plant of pumphouse all as specified and directed by Engr -in charge. Note : 1 ) Contractor is responisble to provide all cleaning material and saftey eqpt to workers . 2) Contractor is fully responsible for any damages and saftey of men power 3) Contractor will shift the sludge at minimum distance as directed by Engineer-in-charge.
Vinod Enterprises
MAHIMA CONSTRUCTION
M/s.NIKI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .