Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-Finance OK | |
| 2 | L2₹28.7 L+₹2.9 L (11.4%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹30.5 L+₹4.7 L (18.2%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹45.8 L+₹20.0 L (77.5%)Accepted-Finance PTAEL NAGAR TELIPHONE EXCHANGE BIJROL ROAD BARAUT BAGPAT UTTAR PRADESH 250611 | BAGHPAT | UTTAR PRADESH | 250611 | L4 | Accepted-Finance OK |
Tender Value
₹52.7 L
EMD Value
₹53,000
Closing Date
14 Jul 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC NOIDA
22 KV SUBSTATION SECTOR-20 NOIDA
Construction of 220 kV AIS Bay and strengthening of 220 kV Main Bus Bar and transfer bus bar at 220 kV S/S Sector-62 Noida under ETD-II Noida
2023_UPTCL_815201_1
E-T-25/ETCN/2023-24
Open Tender
Electrical Works
Item Rate
90 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE ETD NOIDA
₹53,000
25 Aug 2023
24 Jun 2023
15 Jul 2023
24 Jun 2023
14 Jul 2023
24 Jun 2023
Amount
Earth Mat Wrok
Laying of 40mm dia MS round bar 700 mm below the ground level by the cutting straightening welding painting excavation of trench back filling of trench after laying of earth mat including shifting of M S round bar from store place at the Sub-Station to switchyard.
Fabrication of 3 Meter long electrodes with 40 mm dia MS round bar having 150 mm long conical shape by digging cutting, straightening etc. and then placing it vertical inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Station to switchyard.
Making a cross joint of above laid 40 mm dia MS round bar 700 mm below the ground level by due welding at all 4 corners including welding of suitable size 2 No MS angle pieces on opposite corners of the cross joint.
Making of end joint of above laid 40 mm dia MS round bar with Top of the already vertically pierced MS electrodes 700mm below the ground level by due welding.
Making of 300mm long lap joint of above already laid round bar to connecting existing earth mat of the Sub-Station.
Erection of Substation Structure
Sorting and stacking of structures
Erection of Main & Auxiliary structure lattic type ATM, BTM, BCT, ALP etc. consisting of coloumn, beam, peak, mast etc. and auxilary structure for installation of CTs, PTs, LAs, etc. The job consist of shifting of all material from store to site of erection, erection of structure as per drawing with the help of GI nut & bolt, flat & spring washer, matching the hole, cutting & matching of member if required including cost of all men and T & P excluding GI structure Nut & bolt to complete the work. Erection of Main & Auxiliary structure lattice type BCT, ALP etc. upon foundation and its proper tightening.
Erection of following Equipments/Panels as per technical specification, manual and instruction as per direction of supervising engineer.
245 KV SF-6 Circuit Breaker.
245 KV Current Transformer.
245 KV Bus Isolator
245 KV Line Isolator
245 KV Tandam Isolator.
245 KV Post Insulator for support.
198 KV Lighting Arrestors.
220 KV Control & Relay Panel of line feeder.
Earthing Work
Delta earthing of 198 KV LAs and neutral of Transformer by 40 mm dia 150 mm long conical shape its placing inside the ground in rectangular shape and connecting all 3/6 Nos electrodes with 75x10/50x6 mm MS flat laid on its edge and then this rectangle/tringle shape strictly as per drawing.
Earthing of equipments by cutting straightening, bending, laying 700 mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure equipments structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed, excavation of trenches, its back filling, to complete the work.
Laying MS Flat of size 75x10 mm
Laying MS Flat of size 50x6 mm
Laying MS Flat of size 25x6 mm
Cable Laying and Termination work. Laying & Termination of following size control cable in trench/cable trays from different control room equipments to 220/132/33 KV CB, CT, CVT and their junction boxes. Transformer marshalling box, isolator box and other outdoor equipements installed in 132 KV switchyard as per cable schedule including carriage of cable drum from store and all other associated work.
2 Core x 2.5mm2
4 Core x 2.5mm2
6 Core x 2.5mm2
10 Core x 2.5mm2
Termination of control cable at each end.
Bus Bar strenghtening & Jumpering work
Dismantling of Jumpering of equipment with specified conductor of various 220 KV bus isolator with main/Transfer of ACC Tarantulla / ACSR Zebra conductor, 220 KV equipments to equipments, The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work.
Dismantling of various Single Phase 220KV Main Bus/ Transfer Bus/ Jack Bus with different type conductor and different length of span as mentioned below. The work includes cutting & bending of conductor, opening of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from erection site to store site to and all other associated work to complete the work satisfactorily as per drawing and technical specification.
Complete cleaning of disc insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men, T & P to complete the work.
Stringing of various Single Phase 220KV Main/Transfer/Jack Bus with different type twin conductor and different length of span. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
Jumpering, interconnection of equipment with specified conductor of various 220 KV bus isolator with main/Transfer of ACC Tarantulla with twin ACSR Zebra/ Tarantulla conductor, jumpering of 220 KV bay equipment with twin zebra. The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work.
Hoisting of 220KV/132 KV string under Beam to pass the jumper including hanging of disc insulator and suspension fitting complete with all work.
Strengthening of section isolator:-
Providing and fixing of 220 KV arm assembly (male contact 2000 Amp) made of alumnium pipe -1320 mm , OD-60 mm, ID-38mm front side, mounting a copper contact OD-40 mm, length 120 mm, fitted in U shape. Copper housiing mounting upon arm along with hot dip galvanized nut & bolt & washer includind diismentalling of old 1250 amp 220 KV arm assembly and fiixing new 2000 amp assembly, proper checking alignment and adjustment as per technical specification.
Providing and fixing of 220 KV arm assembly (female contact 2000 Amp) made of alumnium pipe -1320 mm , OD-60 mm, ID-38mm front side, mounting a copper U shape housing fitted with 06 no. 30x5 mm copper figure along with hot dip galvanized nut & bolt & washer including dismentalling of old 1250 amp 220 KV arm assembly and fiixing new 2000 amp assembly, proper checking alignment and adjustment as per technical specification.
Rotary head assembly 220 KV isolator made of gun metal backside mounting upon polycone insulator and fitted with arm assembly top side mounting a plate size 80x80x12mm along with 04 no. 12 mm SS spring and hot dipped galvanized nut bolt & washer including dismentalling of old rotary head assembly and fixing of new rotary 2000 Amp proper checking alignment and adjustment as per technical specification.
Supply Portion:-
Bolted type single Tension fitting for Twin Tarantulla Conductor suitable for 1x16 Nos. Disc insulator witht turn buckle with hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Tarantulla Conductor suitable for 1x16 Nos. Disc insulator without turn buckle with hardware set as per techinical specification.
Bolted type single Suspension fitting for Twin Tarantulla Conductor suitable for 1x16 Nos. Disc insulator with hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Zebra Conductor suitable for 1x16 Nos. Disc insulator witht turn buckle with hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Zebra Conductor suitable for 1x16 Nos. Disc insulator without turn buckle with hardware set as per techinical specification.
Bolted type single Suspension fitting for Twin Zebra Conductor suitable for 1x16 Nos. Disc insulator with hardware set as per techinical specification.
4 Bolted Type PG clamp suitable for Tarantulla to Zebra Conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG clamp suitable for Zebra to Zebra Conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG clamp suitable forTarantulla to Tarantulla Conductor Complete with HDG nut bolt & washer as per technical specification.
Bimetallic 220 KV Bus Isolator clamp made of aluminum alloy LM-6 for Twin Tarantulla conductor with HDG nuts & bolts and washer as per technical specification .
Bimetallic 220 KV Bus Isolator clamp made of aluminum alloy LM-6 for Twin Zebra conductor with HDG nuts & bolts and washer as per technical specification .
Bimetallic 220 KV Circuit breaker clamp made of aluminum alloy LM-6 for Twin Zebra conductor with HDG nuts & bolts and washer as per technical specification .
Bimetallic 220 KV Current transformer clamp made of aluminum alloy LM-6 for Twin Zebra conductor with HDG nuts & bolts and washer as per technical specification .
220 KV Bus Post clamp made of aluminum alloy LM-6 suitable for Twin Zebra conductor complete with hot dip galvanized nut, bolts & washer as per technical specification.
Spacer for Twin Tarantulla conductor for 250 mm spacing as per technical specification.
Spacer for Twin Zebra conductor for 100 mm spacing as per technical specification.
Bimetallic 220 KV PT clamp suitable for Tarntulla conductor complete nut , bolts and washer . as per technical specification.
Supply of cable gland of different sizes
2C x 2.5 mm2 (16mm)
4C x 2.5 mm2 (19mm)
6C x 2.5 mm2 (22mm)
10C x 2.5 mm2 (25mm)
Supply of copper lug of different types.
Ring type of size 2.5 mm
Pin type of size 2.5 mm
Lighting Work
Provding and fixing of new generation energy saving and environment friendly long life versatile pressure die casting aluminium outdoor high beam flood light with hgh power 120 watt LED as light source and exclusively designed polycarbonate cover along with electronc drver complete fitting suitable for 220 volt input supply ISI mark makke CGL/ HAVELLS/ SURYA/ BAJAJ or equivalent electrical coneections also to be done by the contractor.
Providing & Fixing of juction box on gantry structure of size 200x200x150 mm made of MS sheet of 16 gauge duly powder coated in side fixing 01 no. 6 amp MCB, 01 no. TB of 04 no. terminal and 01 no. kitkat 16 amp fuse fixed up on mica and backsiide a half round MS clamp and along with PVC pipe fixing on junction box as per technical specification.
Supply and fixing of half round GI pipe OD 50 mm for mounting the 120 watt LED light upon gantry mountng of 02 no. bracket upon gantry and fixing GI pipe complete with GI nut bolt and washers as per techniical specifications.
BARKATI ENTERPRISES
Gupta Elect and Engg Works
M/S AJAY TOMAR CONTRACTOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .