Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹20.8 L+₹1.8 L (9.60%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹20.9 L+₹2.0 L (10.4%)Rejected-Finance DUNIYAGANJ DUNIYAGANJ PHULPUR PHULPUR ALLAHABAD UTTAR PRADESH 212402 | PRAYAGRAJ | UTTAR PRADESH | 212402 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹21.8 L+₹2.8 L (14.8%)Rejected-Finance 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹34,500
Closing Date
14 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) ADM AREA GWALIOR
AF Station Gwalior
PROVN OF CERTAIN BR AND EM WORKS FOR IMPROVEMENT TO ARC P60 AND PROVN OF SOKAGE WELL AND CONNECTED BR WORKS IN OTM DOMESTIC AREA CHAMBAL GATE AND PROVN OF RAILING IN SMQ AREA AT AF STATION MAHARAJPUR GWALIOR
2020_MES_376749_1
8960/E8
Open Tender
Civil Works
Item Rate
180 days
AF Station Gwalior
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF ADM AREA GWALIOR
₹34,500
Yes
24 Dec 2020
14 Sept 2020
16 Oct 2020
14 Sept 2020
14 Oct 2020
30 Sept 2020
14 Sept 2020 - 26 Sept 2020
60 days
Amount
Demolition of old PCC in ground floor & pavings (including floor tile ) n.exc 15 cm thickness below or above GL, including removing excavated material n exc 2.5 KM distance and depositing where as directed, complete all as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size, straight or curved on plan exc 6M mean radius built in Cement Mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size, curved on plan with mean radius not exc 6M built in Cement Mortar 1:4 complete all as specified and directed.
Cutting holes into or through brick wall built in cement mortar and making good in cement mortar 1:3 or in cement concrete 1:2:4, Type B1 as required, superficial area of cutting not exceeding 150 Sq Cm complete all as specified and directed.
M&L for brickwork with sub class 'B' brick in one brick thick honey comb work, curved on plan to any radius, built in CM 1:4 complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding & removing serviceable material to store and rubbish off the premises complete all as directed.
M&L for PCC 1:2:4 type B-0 (using 12.50 mm gradred stone aggregate) as in floor finished even and fair without using extra cement complete all as specified and directed.
M&L for granite of 18mm to 20mm thick (of any type) work (table rubbed/moulding and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20mm screed bed in Cement Mortar 1:4 all as specified.
M&L for vitrified ceramic coloued tiles 10 mm thick, (Light shade/ Double charged/ Ultra Charged) area of each tiles n. exc 0.36 sqm in floors, set and pointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement mortar 1 :6 complete all as specified.
M&L for premium quality non skid coloured ceramic floor tiles 7- 8 mm thick (square/ rectangular) area of each tiles exc. 0.11 sqm but not exc. 0.18 sqm, in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in Cement Mortar (1:6 ) complete all as specified .
M&L for glazed ceramic coloured tiles 450x300 x 6-7mm thick (In patches) on vertical surfaces such as skirting/dados etc, set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 10 mm thick in Cement Mortar 1:3 on wall complete all as specified .
M&L for premium quality glazed ceramic tiles 450x300 x 6-7mm thick (Coloured/ Designed/ Printed) on vertical surfaces such as skirting/dados etc, set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 10 mm thick in Cement Mortar 1:3 on wall complete all as specified .
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of size area exceeding 1.50 Sqm but not exceeding 4.0 Sqm complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of size area not exceeding 1.50 Sqm complete all as specified and directed.
Taking down ventilators area not exceeding 1.50 Sqm complete all as specified and directed.
S&F including fabricating of aluminium powder coated having minimum thickness of powder coating 50 micron for door / window/ ventilator frame, shutters & partition including necessary joining cleats, glazing clips, aluminium snap beading having minimum wt 100gm/RM, rubber neoprene gasket, screws, dash fasteners, rawel plug for fixing of screw in wall or floor etc., aluminium sections as approved by GE complete all as specified and directed. Note : - (i) Builders Hardware shall measured and paid separately under respective item of Schedule 'A' . (ii) Only weight of aluminium section shall be measured and paid. No claim what so ever shall be entertained by the Govt on this account. (iii) Thickness of section shall not be more than 2mm.
S&F drapery rod fancy type, made out of 25mm dia MS pipe having wall thickness 0.63mm bright finish, colour and pattern as approved by GE, over all dia 28-29mm complete all as specified and directed. Make: Aerolux/ MEC/ Vista.
S&F powder coted aluminium grills with aluminium frame including fixing with aluminium channel, 1mm thick with steel screw and tint match with existing complete all as specified and as directed.
S&F for 200 mm long aluminum powder coated barrel tower bolts of extruded section & fixed complete all as specified and directed.
S&F for 150 mm long powder coated aluminum handles fancy type complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Supply Only 6.3 mm thick sheet glass ordinary quality, frosted one side for aluminium doors and fully glass partitions exc 0.50 Sqm in each pane complete all as specified.
S&F 4.80 mm thick sheet glass ordinary quality for aluminium windows/ ventilators in square not exc 0.50 Sqm in each pane complete all as specified.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples etc. in wooden door / window, completed all as specified and directed.
S&F aluminium body door closer hydraulically regulated, designation No -1, universal type, suitable for door shutter up to 700 mm in width and of weight 35 Kg (ISI marked) complete all as specified and as directed.
S&F mortice lock (ISI marked) of stainless body, size 100mm, 2 lever, vertical type fixed to door complete all as specified and as directed.
S&F pressed steel door frames of size 105mmx60mm made out of mild steel sheet for doors with one or two rebate inluding necessary fixing lugs, hinges, lock strike plate complete all as specified and directed.
M&L for providing cement concrete 1:3:6 Mix, Type C0 (using 12.50 mm graded stone aggregate) as in back filling of door frames/ hold fast block including necessary fom work if required complete all as specified and directed.
Supply only mild steel butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F for solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube incl 75mm long MS screws for fixing to walls all as per specified in SSR complete all as specified and directed .
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel’ having a PVC sheet strip’ of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the fame at site as per specification & drawing. complete all as specified .
S&F powder coated aluminium sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of size 300 mm complete all as specified and directed.
S&F 150mm mild steel helical door springs for flyprrof doors complete complete all as specified and directed.
S&F for 200 mm long aluminum nodised barrel tower bolts of extruded section & fixed complete all as specified and directed.
S&F for 150 mm long anodised aluminum handles cast type complete all as specified and directed.
S&F for 100mm long butt hinge extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, Type C-21 complete all as specified and directed.
Taking down old cement plaster on brick or stone wall etc incl racking out joints hacking for key & scrubbing down with water etc and remove rubbish from site of work. complete all as directed.
M & L for 15 mm thick rendering on fair faces of brick wall with mixing WPC as per manufacture instructions . finished fair & even in Cement Mortar 1:6 complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick wall with mixing WPC as per manufacture instructions . finished fair & even in Cement Mortar 1:4 complete all as specified. (Note :- WPC will be measured and paid separately under relvant item of BOQ)
Supply only liquid water proofing compound (Liquid type) complete all as specified and directed.
Supply only integral water proofing compound (powder) complete all as specified and directed.
M & L for 10 mm thick rendering on concrete surfaces of ceiling finished even & smooth without using extra cement in Cement Mortar 1:3 complete all as specified .
M&L for preparation of newly plastered surfaces on walls and apply two coats of oil emulsion distemper over and including a thin layer of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint (Apex from Asian Paint or equivalent make as specified) over and including a thin layer of JK/ Birla wall care putty and a coat of suitable primer on plastered surface of brick or concrete surface after preparation of newly surfaces complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint (Apex from Asian Paint or equivalent make as specified) over and including a thin layer of JK/ Birla wall care putty and a coat of suitable primer on plastered surface of brick or concrete surface including removal of existing tratment complete all as specified and directed.
M&L for applying two coats of oil bound distemper over and including a thin layer of JK/ Birla wall care putty and a coat of suitable primer on plastered surface of brick or concrete surface including removal of existing tratment complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
S & F in repair Vitreous china wash basin , white , flat back, size 550 x 400 mm, excluding taps waste ,chain and plug and porcelain stopper but incluing brackets, waste pipe and PVC waste coupling and 15mm bore CP, brass mixer Tap fancy type and cutting for and pinning in ends of brackets or errecting stand, complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing of serviceable pipes and unserviceable pipe removal from site of work complete all as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing of serviceable pipes and unserviceable pipe removal from site of work complete all as directed.
M&L for cutting existing steel tubing for alterations or additions (Each cut measured) including screwing existing steel tubing done in position (without taking down) for 15 mm bore GI Pipe complete all as specified and directed.
S&F for GI tubing 15mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified.
S&F for GI tubing 20mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified.
S&F for GI tubing 25mm dia bore medium grade with and including all fittings ISI marked, laid in floor complete all as specified.
S&F 5mm thick beveled edge best quality looking mirror of size 600x450 mm with 30 mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 4mm thick AC bldg board, complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest and 'S' or 'P' traps(cast iron 100mm bore) (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc complete all as specified in SSR and complete all as specified.
Supply and fix in repairs of PVC flushing cistern 10 ltr capacity valve less symphonic action type low level with and incl ball valve float & handle, waste pipe & fixing accessories to wall complete all as specified.
Supply Only flush pipe of PVC, 32 mm bore complete all as specified and directed.
S&F chromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed.
S&F vitreous china urinal half stall type urinal complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm brass screws pointing around urinal back in cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe complete all as specified and directed.
S&F in repair 15 mm bore brass chromium plated shower rose 75mm size complete all as specified and as directed.
S & F in repair 15 mm dia Bib taps, cast copper alloy, fancy type with capstan heads ,chromium plated, screwed down , screwed for iron pipe or for brass ferrule and fixed, complete all as specified.
S & F 15 mm dia Bib taps, cast copper alloy, high pressure with crutch or butterfly handles, screwed down , screwed for iron pipe or for brass ferrule and fixed, complete all as specified.
S&F in repair 15 mm bore stop valves, fancy type, chromium plated, cast copper alloy, long shank and cup (concealed type) screwed down, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed.
S&F stop valve, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed of 25 mm bore complete all as specified and directed.
S & F in repair 15 mm dia fancy type angle/stop cock, cast copper alloy, with chromium plated, screwed down , high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, complete all as specified.
S&F in repairs PVC connections 15mm size of PTMT of 450mm long. complete all as specified.
M&L for POP ceiling by 15 mm thick plaster of paris finishing 10 mm thick lathing and 5 mm thick finishing on ceiling, 0.56 mm nominal dia and aperture 1.18 mm of wire mesh including dome or one step inside the ceiling designas approved by GE on GI frame work of grid size 605x605 mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding walls using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.90 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20 M length) of 0.55 thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hangers 6mm dia. GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40-x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long with and including two coats of plastic emulsion paint over a coat of primer complete all as specified and directed.
Excavating over areas, n exc 1.5m deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating over areas, exc 1.5m deep but n exc 3.0 M deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating over areas, exc 3.0 m deep but n exc 4.50 M deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating over areas, exc 4.0 m deep but n exc 6.0 M deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC 1:4:8 Mix, Type D2 (Using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for RCC 1:1.5:3 Mix, Type A1(using 20mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles, raft etc and mass concrete complete all as specified and directed.
M&L for formwork for rough finish to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for RCC 1:1.5:3 Mix, Type A1(using 20mm graded stone aggregates) as in seismic and other similar bands etc including necessary form work complete all as specified and directed.
M&L for loose filling with broken brick aggregate of gauge 80 to 150 mm in soakage pit/ soakage well complete all as specified and directed.
M&L for formwork for rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed.
M&L for RCC 1:1.5:3 Mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed.
M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for salt glazed stone ware (SGSW) pipe of 150 mm bore conforming to IS, laid in trenches and jointed in CM (1:1) complete all as specified and directed.
M&L concrete bed to pipes in PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for 150 mm bore sewer pipe line complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus spoil to a distance exc. 250 Mtr but not exc 500 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 Mix, type B1 complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in plinth protction, finished even and smooth without using extra cement complete all as specified and directed.
Cutting into existing steel tubing, screwing for addition to 25 mm bore tubing without taking down complete all as specified and directed.
Disconnecting existing tanks of capacity exc 500 litre but n. exc 1000 litre for repair work and refixing the same after repair work is over complete all as specified and directed.
M&L for framed work of stainless steel as in grill, railings for water tanks and similar work of design and section of stainless steel as approved by GE with ends of bar shouldered or rebated, or forged into spikes. The framework is to be secured in the existing RCC/ Brick work with necessary fastening arrangements as per manufacturers instructions to suit the site requirement complete all as specified and directed.
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor cable FR, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor cable FR single core. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE: (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering, Make of Laminated Sheet:-/Hylam/National)
All as per item No 93 hereinbefore but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
All as per item No 93 hereinbefore but point wiring for one 5 pin socket outlet, on same board .
All as per item No 93 hereinbefore but point wiring for one six pin socket outlet, 16/6 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
M & L for switch flush type single pole one way 5/6 Amps, 240 volts, white ivory finish complete all as specified. (Make :- Anchor(Panta)/ Cona/ Leader)
ReFixing Only retreaved against Sch. 'A' item switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified all as directed by Engineer-in-Charge.
M&L for socket outlet 2 in 1, 5 pin, 6 Amps 240 Volts flush type white ivory finish complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for switch socket combination multi purpose, 5 Pin 6 amps 240 Volts, flush type with Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
Refixing Only retreaved against Sch. 'A' item switch socket combination multi purpose, 5 Pin 6 amps, flush type complete all as specified and directed by Engineer-in-Charge.
S&F for switch socket combination multi purpose, 6 Pin 6/16 amps, 240 Volts flush type with Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
Refixing Only retreaved against Sch. 'A' item switch socket combination multi purpose, 6 Pin 6/16 amps, flush type complete all as specified and directed. by Engineer-in-Charge.
M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
M&L for lamp holder insulated body with back plate for batten fitting complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for step type electronic fan regulator single phase ,230 volt, 100/120 watt . Complete all as specified. (Size of PT switch ) Make:-Cat part No 3211 of cona or equivalent of Leader/ Anchor(Panta).
Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified. (Make-Havell's Cat Part No LUMILINEBS20WLED865SPCWH/Surya Cat No -SLEBT -20 /CG cat No -LCTL 18 CDL)
S&F in replacement 34W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 595x595x70mm complete with LED tube and all accessories specified. (Make : Havells cat part No PLUTONEO2X2PLR34WLED840S /Surya Cat No- SLEFP36R 22/ CG Cat Part No -LCTLSN36- CDL.)
S& F for Street light fittings 1x15watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washer. Complete all as specified. ( Make : Havells Cat part No - ENDURAPEARLSL15WLED757SASYTOPC /Surya Cat Part No -SLRUL 15W IP 66LXN/CG cart part No -LSTS-15CDL.)
Supply and fixing LED porch light IP55 surface mounted led porch light in engineering plastic housing with clear prismatic diffuser 6w LED complete with lamp etc and all accessories pre wired and incl. connecting up with twin core twisted flexible copper conductor cable with suitable size. upto the ceiling rose inclu taking out all as directed by Engineer-in-Charge.Make: C & S Cat Part No CG80B6WLED or equivalent of ,Havells / CG.
Dismaintling & Taking out MCB DBs any size , any type and capacity and remove materials from site of works. Complete all as directed.
S&F for sheet metal enclosure Double door for DB’s 12 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires. Complete all as specified. (Make;ABB,Schneider,Legrand)
S&F for MCB single pole 6 to 32 Amps, "C" Curve ,240 Volts complete all as specified (Make:Legrand/ABB/Schneider )
S&F for MCB Single pole and neutral 40 Amps 10 KA, 'C' series, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider )
S&F for MCB TPN 63 Amps, 10 KA, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider)
S&F for sheet metal enclosureDouble door for DB’s 4 way 415 volts, triple pole and neutral supply complete, fixed properly on MS strips and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified. (Make;.ABB/Schneider/Legrand)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 10.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including conceled PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor cable FR all as specified and directed including taking down old submain wiring with any type of conduit. Complete all as specified. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out old sub main wiring with any type of conduit.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as specified. (Make:ABB/Schneider/Legrand)
Taking down carefully ceiling fan/exhaust fanwall fan including electric connection complete from site to MES yard, scraping, cleaning, painting with two coats of super enammenled paint, greasing, oiling and re-fixing the same in existing position after civil work with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
M&L for earthing complete with MS Galvanised earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed.
Supplying and Lay Dry and clean fine sand for cable cushioning to under ground cable protection, complete all as specified. (Note :- only punned thickness shall be considered for measurement).
M&L for sub class B bricks, old size, kiln burnt, laid with axis of brick perpendicular to axis of cable for cover/protection of underground cable complete all as specified.
Dismantling and Taking out old us corroded GI water tubing and Supplying, laying & jointing GI water tubing 80 mm bore, light grade, ISI marked as in sleeving etc laid in trenches/ducts/wall/pole etc fixed with all accessories and as per site requirment as specified. (MAKE : TATA/JINDAL/ SWASTIK).
Supply, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to pole/ walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes. (Make :- Polycab/Havells/Finolex )
(a) LT aluminium conductor cable of size 50 Sqmm 4 core
NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise panel recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
M/S MAHAVIR SINGH
M/s Shubham Construction Co.
M/S M.D. CONSTRUCTION .CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .