| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.7 L+₹21,732 (1.74%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹12.8 L+₹25,358 (2.03%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹12.8 L+₹28,578 (2.28%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹12.8 L+₹28,668 (2.29%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
1 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIRS/MAINTENANCE OF MISCELLANEOUS E/M EQUIPMENT AND COOLING APPLIANCES AND ALLIED WORKS AT PEDONG, ALGARAH, DALAPCHAND, AP ALGARAH, RHENOCK, RONGLI AND TEESTA TCP UNDER GE 867 EWS
2021_MES_451451_6
CA NO GE / 867 / TOKEN / 26 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Pedong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹23,000
Yes
13 Feb 2022
11 Jan 2022
2 Feb 2022
11 Jan 2022
1 Feb 2022
20 Jan 2022
11 Jan 2022 - 17 Jan 2022
60 days
Amount
Comprehensive annual maintenance for Central Heating System of Variable Refrigerent Volume 62 HP OUTDOOR UNIT including preventive maintanance, repair as required for smooth and efficient functioning of the following units including four routine services at the intervel of 3 months at Pedong Military Station:- (a) List of Outdoor Units :- (i) VRV Outdoor Unit 6 HP Model/Sr. No. RXYQ6ARY6 (611)- 01 No. (ii) VRV Outdoor Unit 12 HP Model/Sr. No. RXYQ12ARY6 (1215, 1216) - 02 Nos. (iii) VRV Outdoor Unit 14 HP Model/ Sr. No. RXYQ14ARY6 (864)- 01 No. (iv) VRV Outdoor Unit 18 HP Model/Sr. No. RXYQ18ARY6 (1274)- 01 No. The following Spare Parts shall be replaced free of cost in case of any breakdown during AMC period. (i) Compressor. (ii) Fan motor. (iii) P.C.B. (iv) Magnetic switch. (v) Transformer. (vi) Other electrical parts of AC units.
Material and Labour for complete periodical servicing and routine maintenance of Variable Refrigerent Volume INDOOR UNIT of given capacity alongwith all its allied accessories in all respects including dismantling of unserviceable spare parts for replacement of the same, vacuuming, leak testing, brazing the suction / discharge tubes where required, cleaning of Air Filter, Oiling of Blower, replacement of Bushes 2 Nos. for fan motor, cleaning of condensor coil by high pressure water and liquid cleaner with and including installation of Air conditioner at location where directed after proper repair and testing at site as per the satisfaction of executives complete all as specified and directed. NOTE: - The servicing work shall be carried out by engaging a team of well trained skilled tradesman duly equipped with complete tool and plants and good quality descaling chemical as required at site. Replacement of major spare parts and filling of Gas as detailed hereinafter in this schedule shall be measured and paid seperately. Note : Serving shall be done once in three months.
Hi Wall indoor unit 1.06 TR Model/Ser No FXAQ32PVE6 ( E017330) -01 No.
Hi Wall indoor unit 1.32 TR Model/Ser No FXAQ50PVE6 (E029005, E029006) -02 Nos .
Hi Wall indoor unit 1.65 TR Model/Ser No FXAQ40ARVE6 (285, 290), FXAQ50PVE6 (E029008) -03 Nos
Hi Wall indoor unit 2.08 TR Model/Ser No FXAQ63ARVE6 (495, 504) -02 Nos.
Ductable indoor unit 1.65 TR Model/Ser No FXMQ50ARV16 (2390, 2434, 2435, 2438). - 04 Nos.
Ductable indoor unit 2.08 TR Model/Ser No FXMQ63ARV16 (3868) -01 No.
Ductable indoor unit 2.65 TR Model/Ser No FXMQ80ARV16 (3005,3160, 3161)- 03 Nos.
Ductable indoor unit 3.3 TR Model/Ser No FXMQ100ARV16 (1266)- 01 No.
Ductable indoor unit 4.12 TR Model/Ser No FXMQ125PVB36 (1253)- 01 No.
Ductable indoor unit 5.5 TR Model/Ser No FXMQ170NVE6 (972, 973, 975, 977)- 04 Nos.
NOTES FOR ITEM NO. 1 & 2:- (i) The above comprehensive maintenance shall be carried out only through OEM i.e. M/s Daikin Airconditioning India Pvt Ltd. The contractor shall have to submit MOU as per proforma specified here-in-after from M/s Voltas Ltd and copy of Annual Maint Contract from OEM within ten days of acceptance of tender through GE duly verified, failing which the contract will be liable to be cancelled and work shall be executed at risk & cost of the contractor. (ii) No payment will be made to contractor without submission of valid AMC agreement. (iii) The extent of work/services to be carried out in annual comprehensive maintenance as specified in particular specifications. (iv) The plant maintenance include complete maintenance by regular and systematically examining for smooth and efficient functioning of the plants. (v) Replacement of all major or minor spares parts and/or defective spares parts (if damaged during AMC period) and maintenance items required during AMC period are deemed to be included in the quoted rates except which are specifically specified in AMC provided by OEM. (vi) The quoted rates are deemed to be included for replacement of spares / material by OEM free of charge without extra cost of material. (vii) The contractor shall arrange to attend to the unit for any problems regularly. (viii) In case of any defect to existing compressor, the contractor shall repair the same within time as directed by GE and/or as specified in PS and in case of failure of compressor, the contractor will replace the same with new compressor of same specification/make and the contractor’s quoted rates are deemed to be included for above provisions. (ix) The retrieved defective/unservicable minor/major parts shall be the property of contractor and shall be removed from site as directed. (x) Penalty Rs 1000/- per day shall be imposed on account of non rectification of defects or not carrying out the repair work within 3 days.
Material and Labour for complete periodical servicing and routine maintenance of Split type, Air Conditioners of any type and capacity alongwith all its allied accessories in all respects including dismantling of unserviceable spare parts for replacement of the same, vacuuming, leak testing, brazing the suction / discharge tubes where required, cleaning of Air Filter, Oiling of Blower, Condensor Fan Motors, replacement of Bushes 2 Nos. for fan motor, cleaning of condensor coil by high pressure water and liquid cleaner with and including installation of Air conditioner at location where directed after proper repair and testing at site as per the satisfaction of executives complete all as specified and directed. NOTE: - The servicing work shall be carried out by engaging a team of well trained skilled tradesman duly equipped with complete tool and plants and good quality descaling chemical as required at site. Replacement of major spare parts and filling of Gas as detailed hereinafter in this schedule shall be measured and paid seperately.
S & F as in replacement rotary type compressor (sealed unit) suitable for 1.50 Ton capacity split type Air Conditioner with and including its allied accessories, first filling of refrigrant gas, necessary cutting, brazing and testing complete all as specified and directed. MAKE- Tecumesh, LG, Samsung, Carrier, Emerson, Bluestar, Hitachi.
S & F of capacitor 10 MFD, 230 volts, 50 Hz complete all as specified and directed. MAKE- Epcos, Havells, Usha.
Repair and maintenance of electronic PCB card including repair to relay, driver, transformer diodes, BDR, IC, resistance etc. suitable for 1.50 Ton capacity Air Conditioner any type complete all as specified and directed.
Supply and filling of Refrigerant gas R-32 compressor of 1.5 and 2 TR capacity (Hot and cool ) Split Type Air conditioners complete all as specified and directed.
Material and labour for Communication cabling between ODU and IDU as per OEM Specification of size 2core x 0.72 sqmm complete all as specified and as directed.
Supply and fixing of power contactor 4 pole 200 Amps all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
S&F RCCB four pole 300mA, 25 Amp 240 Volt including taking down existing RCCB complete all as specified and directed by the Engr-in-Charge. Make: LEGRAND /SIEMENS/SCHNEIDER.
S&F RCCB four pole 300mA, 40 Amp 240 Volt including taking down existing RCCB complete all as specified and directed by the Engr-in-Charge. Make: LEGRAND /SIEMENS/SCHNEIDER.
S & F MCCB four pole 160 Amp, 415 Volts, 'C' Curve, 36 KA breaking capacity, Ics=100% Icu with thermal magnetic protection including taking down old MCCB complete all as specified and directed by Engr-in-Charge. Make: LEGRAND /SIEMENS/SCHNEIDER.
S & F MCCB four pole 200 Amp, 415 Volts, 'C' Curve, 36 KA breaking capacity, Ics=100% Icu with thermal magnetic protection including taking down old MCCB complete all as specified and directed by Engr-in-Charge. Make: LEGRAND /SIEMENS/SCHNEIDER.
Comprehensive maintenance/Servicing of Refrigerator/Deep Freezer of any make any model installed at various locations, including oiling/greasing the blower motor, bearings etc, evaporator, condensor externally to remove the dust, replacement of defective parts all as directed by Engr-in-charge. (Comprehensive maintenance also includes transportation of Refrigerator (if required) to workshop for repair after repairing the same will be re-installed properly to same location).complete all as directed by Engineer-in-Chare. . Note:- Accessories / spares/ Gas charging required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Thermostat switch three speed
Supply only door gasket
Supply only Over load realy
Supply only Cooling coil motor single phase 230 volts
Supply only Vegetabe tray
Supply only Racks of suitable size
Supply only Inner lamp of refrigerator
Supply only Biometer for double door refrigerator
Supply only Heater for double door refrigerator
Charging of refrigerant gas
Supply only Starting capacitor of existing type
Supply only Running capacitor of existing type
Supply only Expansion valve of existing type
S & F in replacement 'R' compressor for Refrigerator of capacity 160-210 ltrs from authorized dealer including connected works like cutting and brazing the refrigerant pipe complete including gas charging all as specified and directed by Engr-in-charge. Make : Copeland/Shri Ram/ Carrier/ LG/ Bluestar
All as per Item No 29 above but for deep freezer of 210 Ltrs to 320 Ltrs
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 7,475.00 B/F from Ser page No. 26 NOTE: Bidder shall insert credit amount as rate Rs. 7,475.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
G K SUTHAR
MS MAYA PRAKASH GOEL AND SONS
MANOJ JINDAL
SANJAY SAW MILL
PRASAD PRADHAN AND SON
MS BRAHMA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .