| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.4 L+₹2.7 L (14.6%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹21.9 L+₹3.3 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹22.0 L+₹3.4 L (18.0%)Rejected-Finance | L4 | Rejected-Finance Being not L1 |
Tender Value
₹26.2 L
EMD Value
₹52,500
Closing Date
16 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WKS ENGRS
HQ 133 WKS ENGRS PIN 914133 C/O 56 APO
SPECIAL REPAIR TO BLDG NO. T-841, T-842 AND T-843 AT BB CANTT UNDER GE 864 EWS
2020_MES_340004_2
CWEK-02/2020-21
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE 864 EWS
Class D Category a (i)
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹52,500
Yes
HQ 133 WKS ENGRS
6 Jul 2020
19 May 2020
18 Jun 2020
19 May 2020
16 Jun 2020
2 Jun 2020
19 May 2020 - 26 May 2020
26 May 2020
60 days
Amount
Building And Other Works
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) not exc1.5 sqm each including cutting holes for taking out hold fasts or dismantling brick work / stone work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to the Govt.), complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc1.5 sqm but not exc 4 sqm each including cutting holes for taking out hold fasts or dismantling brick work / stone work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to the Govt.), complete all as specified and directed.
Supply and fixing for sheet glass 3mm thick, ordinary quality , in square not exceeding 0.5 Square metre each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, complete all as specified.
Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter ( wire and glass panes shall be measured and paid separately ) with side hung shutters with steel handle and steel peg stay dovetailed ot welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg No CESZ-TD/1018/2011 Sheet No. 1/3 to 3/3 welded to FI frame work , incl other fittings ,hinges ,handles tarred hold fasts PCC blocks etc.complete all as specified as shown on drg No CESZ-TD/1018/2011 Sheet No. 1/3 to 3/3.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed.
M & L Appling two coat of synthetic enamel paint on steel and iron surfaces of any description not otherwise describe over width or girth including preparation of new surfece and appling one coat of red oxide zinc chrome complete all as specified and directed.
Supply and fixing Factory made pressed steel frames for doors fabricated from 1.25 mm thick sheet, with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. and one shop coat of priming, frame size 125 x 60 mm, complete all as specified and directed.
PCC (1:3:6) type C-2 (20 mm graded aggregate) filling back of chowkats, complete all as specified and directed.
M&L for 35 mm 2nd class H/.W plain framed factory made, paneled shutter with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces .The size of rail and stile as per IS :1003(Part-I ) kiln seasoned and chemically pressure treated.
35mm thick 2nd class hard wood factory made Gauged and skeleton shutters open rebated & prepare to receive glass, gauge etc (without sash bars /edges of framing plain chamfered or rounded, fitted with cut and mitred beds for securing glass etc) size of members of shutters as spd in SSR Part-I section-8 clause 8.2 (A).
Preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as spd.
S&F 150mm long aluminium anodised barrel tower bolt .
S&F 150mm long aluminium anodised fabricated type door handle.
S & F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
S & F 200mm Helical door springs incl roller and roller plate complete. .
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Brick work with sub class `B` old size bricks straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as speecified and directed
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement all as specified.
Rendering 10mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement all as specified and directed.
Preparation of new plastered surface of wall by applying 2mm thick wall care and making the surface smooth and applying two coat of oil emulsion distemper complete all as specified & directed.
Preparation of new plastered surface of external wall surface applying two coat of cement base paint incl curing complete over a of alkali-resistant priming paint all as specified & directed.
Preparation of old plastered surface of wall by applying 2mm thick wall care and making the surface smooth and applying two coat of oil emulsion distemper complete all as specified & directed.
Preparation of old plastered surface of external wall surface applying two coat of cement base paint incl curing complete over a of alkali-resistant priming paint all as specified & directed.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed.
Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair incl making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified
Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed cement screed base laid and jointed with grey camant slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for tread of staircase after roughing surfaces of old concrete floor by picking sweeping down with water to remove dust etc
Machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for risers of staircase incl rendering 10mm thick in CM (1:4) and finished rough. all as spd and directed
M & L screed bed or bedding layers of mortars 15 mm thick in CM 1:6 for laying floor finishes.
Dismantling timber scantlings 40 sq cm & over in section, in any position in framed work
M & L for second classs soft wood tilmber framed and fixed clean sawn as in scantling all as specified.
Dismantling plain or corrugated asbestos sheeting, any gauge thickness, incl nainital or similar pattern roof covering, complete all as spd.
S&F 0.5 mm thick pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified
S&F 0.5 mm thick pre-painted galvatume aluminium zinc coating GI based plain steel sheet of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/blankets, any thickness, including cover fillets.
Suspended false ceiling system using E grid suspended ceiling grid system, Grid size 600mm x 600mm with and including G.I frame work of main runners 38mm x 24mm , cross Tee 28mm x 24mm and wall angle 24mm x 24mm hot diped galvanized steel with zinc coating not less than 120gm /sqm using 9mm thick high pressure stream cured fibre cement pre primered textured variant E board classic , ISI Marked IS- 14862-2000 to be placed in grid of E grid suspended ceiling grid system duly suspended by 8mm dia GI bar hangers from existing purlins to roof with butterfly clips complete all as spd & directed
M & L for 60 mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over 50 mm thick sand cushion over 75 mm th hardcore of gauge n.exc 63 mm broken boulder or stone agg complete all as specified.
Electrification work
Taking down carefully any type point wiring (light, fan, socket or power) complete with fittings such as switches ceiling roses, pendants, regulators, sockets tube light fitting with all accessories etc. removal of materials from site and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces complete, all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area) single core flame retardant low smoke (FRLS) PVC insulated and unsheathed stranded cable 1100 volts grade ISI-694 marked TEC and FIA approved in and including medium grade , ISI marked PVC casing caping not less than 32 mm width , 10 mm depth with accessories fixed on wall/ceiling surface incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke (FRLS) , 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with GI flush box , inner and outer plate as required for housing modular switch and socket as per module for one light/fan point controlled by one switch. Note :- GI flush box , inner and outer plate, Modular Switch, socket and fan regulators to be measured and paid for separately), complete, all as specified and directed. PVC Conduit confirming to IS 9537 part I & III
Description all as per Srl item No.2.02 here in before but for socket outlet point 5 Amp on same board.
Description all as per Srl item No.2.02 here in before but for socket outlet point 5 Amp on Independent board complete, all as specified and as directed.
All as per the description of Serial Item No 2.02 above, but with 2.50 Sq mm un-sheathed multistranded cable for one socket outlet 15 Amps independent including continuous copper earth wire, PVC insulated of 2.50 Sq mm size complete, all as specified and as directed . (Switch, Socket shall be measured and paid separately)
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, ISI Marked, complete all as specified and as directed.
Supplying and fixing the ceiling rose, three terminal ISI marked surface backlit, complete all as specified and as directed.
Supply and fixing switch 6 Amps, one way one module, 230 volt , AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing switch 16/20 Amps, one way 230 Volts, one module, 50 Hz , AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing socket 6/16 Amps 2 in 1, 6 pin, one way 230 volts, 2 module, complete all as specified and as directed.
Supply and fixing socket 3 Pin 5 Amp and 16 Amps 2 in 1, 6 pin, one way 230 volts, 2 module, complete all as specified and as directed.
Supply and fixing fan regulator electronic step type (0-4) two module, 120 watt, 230 Volts, 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed.
LED light fitting fixture 20W, 6500K, decorative ultra slim with extruded Al, heat sink, environmental friendly. energy efficient ready to use complete all as specified.
LED light fitting, 10 Watt bulk head luminaries with all accessories including connecting up with twin core twisted flexible copper cable, complete all as specified and directed.
10 watt LED having PF not less than 0.9 complete all as specified and directed. Make B22 of Havells or equivalent of approved make as approved by GE.
Supply and fixing sheet metal enclosures for distribution board for MCB's Load line, TPN, 4 ways,double door, 415 volts, with and including 200 amps rated bus bar, vertical type, IP 43, with MCB as incomer and MCB's as out going with suitable size of MS cabinet 2mm thick and making all type of connections with suitable size of gland for incomer cable complete , concealed on the wall surface, making good the disturbed portion with adjoining surfaces to match with existing finish and taking down the existing DB's and MCB's any type complete all as specified and as directed.
Supply and fixing sheet metal enclosures for distribution board for MCB's Load line, TPN, 4 ways,double door, 415 volts, with and including 200 amps rated bus bar, vertical type, IP 43, with MCB as incomer and MCB's as out going with suitable size of MS cabinet 2mm thick and making all type of connections with suitable size of gland for incomer cable complete , concealed on the wall surface, making good the disturbed portion with adjoining surfaces to match with existing finish and taking down the existing DB's and MCB's any type complete all as specified and as directed.
Supply and fixing MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, C curve, 6 to 32 Amps, ISI marked, complete all as specified and as directed.
Supply and fixing MCB single pole neutral , 240 volts, 50Hz , breaking capacity 10KA, C curve, 63 Amps, ISI marked complete all as specified and as directed.
Material and labour for sub main wiring with two single core flame retardant low smoke (FRLS) , PVC insulated unsheathed copper conductor cable 4.00 sqmm drawn through and including medium grade , ISI marked PVC casing caping not less than 32 mm width , 10 mm depth with accessories fixed on wall/ceiling surface with one additional PVC insulated , stranded copper conductor flame retardant low smoke (FRLS) of 2.5 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring complete, all as specified and directed. Note- 2 run of 4.00 sqmm and 1 run of 2.5.00 sqmm cable with casing caping shall be measured as 1 unit.
Wall mounting fan 400mm sweep single phase 230 Volts AC with regulator, fixed properly on wall surfaces and connecting/ testing, complete all specified and directed.
Excavation in trenches in not exceeding 1.5M wide and not exceeding 1.5M in depth for laying of cables including getting out in any type of soil complete as specified and directed..
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, Note :- 1. Dry fine sand of best available quality shall be used.2. Punned thickness shall be measured and paid.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
GI pipe light grade for road crossing /on wall/on pole for cable protection of size dia 40mm light grade, all as directed and specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq mm 3.5 core.
60 Watts LED building security light fitting including suitable bracket and nut bolts etc., all as directed and specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in gound (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earht strip protected by provision of GI light grade pipe 20 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for wetering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm/6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
M/S Ghulam Mohammad Shalla
M/S PARVEZ AHMAD LONE
M/S AKMAL CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .