Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.7 L+₹3.3 L (7.11%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹50.0 L+₹3.6 L (7.72%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹50.9 L+₹4.5 L (9.74%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹51.4 L+₹5.0 L (10.9%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
14 Dec 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minnie bay Port Blair 744103
REPAIR AND MAINT OF DRAINS FOOTPATH FENCING COMPOUND WALL CLEANING OF SEPTIC TANKS SEWAGE LINES ETC FOR AJAY BAUGH AND DAY TO DAY B/R MAINT WORKS AT ASHWINI NAGAR JAYANT PARK INHS DHANVANTARI AND OTHER ALLIED WORKS UNDER AGE B/R-I AT GE MINNIE BA
2023_MES_626515_2
8316/E8
Open Tender
Civil Works
Item Rate
270 days
Minniebay Port Blait
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹96,000
Yes
18 Jan 2024
24 Nov 2023
16 Dec 2023
24 Nov 2023
14 Dec 2023
8 Dec 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation and getting out as in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches exceeding 1.5 m wide and not exceeding 3 m in depth for foundation and getting out as in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Excavating over areas, n exc 1.5m deep & getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soils n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Removing & cleaning of blockage WC including WC trap of any description and in any position by removing sand/sludge/silt and other forein material deposited in it (either manually or mechanically) upto first manhole and making the sewage system functional complete all as specified and as directed by Engineer-in-Charge.
Removing & cleaning of blockage from traps of bath rooms/ kitchen sink/ wash basin/ Urinal point and gully traps of any description and in any position by removing sand/sludge/silt and other forein material deposited in it (either manually or mechanically) upto first manhole and making the seweage system functional complete all as specified and as directed by Engineer-in-Charge.
Taking out carefully the cover slab of gully traps of any size and shape, depth and cleaning the block by removing the scum/sludge / any material to a distance exc. 250m and n.exc.500m and cleaning with fresh water placing the cover slab/ Grating in position complete all as specified and as directed by Engineer-in-Charge.
Cleaning of sewage lines using passing rubber ball through line to ensure all blockage perfectly clear or split bamboo with a gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage lines of dia 100 mm and up to 200 mm through manhole/gully trap clear flow of sewage is observed in sewage pipe complete all as specified and as directed by Engineer-in-Charge.
Pumping out/dewatering of soakage wells septic tanks etc of any size and depth by machanical means i.e. pumping sets etc and removing the muddy water in liquid or semi-liquid/solid state to a distance exc. 250m and n.exc. 500m complete all as specified and as directed by Engineer-in-Charge.
Taking out and removing waste materials/foreign materials from septic tank by manual labour or mechanical means of any size and burying the entire sludge under ground in a pit of suitable size and covering the pit with earth or earth mixed rubbish and removing surplus soil to a distance n.exc 50m including necessary earth work in pit complete all as specified and as directed by Engineer-in-Charge.
Cleaning manhole and taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size outside MD land and clearing the sludge and ensure the sludge is drain out completely and depth of manhole n. exc. 1 meter each complete all as specified and as directed by Engineer-in-Charge.
Cleaning manhole and taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size outside MD land and clearing the sludge and ensure the sludge is drain out completely and depth of manhole exc 1m and n. exc. 2m each complete all as specified and as directed by Engineer-in-Charge.
Cleaning manhole and taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size outside MD land and clearing the sludge and ensure the sludge is drain out completely and depth of manhole exc 2m and n. exc. 3m each complete all as specified and as directed by Engineer-in-Charge.
Making arrangement of scaffolding height exc 3m and n exc 13m in the shafts / spot/ location of weed growth removing the weed including its root, making good with CM 1:3 or PCC 1:2:4 (12.5mm graded aggregate)including two coats of acrylic paint with primer complete all as specified and as directed by Engineer-in-Charge.
Making arrangement of scaffolding height n exc 3 m in the shafts / spot/ location of weed growth removing the weed including its root, making good with CM 1:3 or PCC 1:2:4 (12.5mm graded aggregate)including two coats of acrylic paint with primer complete all as specified and as directed by Engineer-in-Charge.
M & L for clearing vegetation /Shrubs along with all the debris of leaf from roof slab and making surface clean ,making the surface good if any crack observed with CM 1:3 or PCC 1:2:4 (12.5mm graded aggregate) as per the requirement complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable PVC Pipe of size 75mm & 110mm and 150 mm from trenches and walls with all fitting incl. necessary excavation RFR and removal upto 250 mtrs complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary clamps as required complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary clamps as required complete all as specified and as directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
S& F, 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches floor or wall and similar works complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain cement concrete bed (1:3:6) type C1 to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in 150mm dia pipe complete all as specified and as directed by Engr-in-Charge.
M&L for Plain cement concrete bed (1:3:6) type C1 to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in 100mm dia pipe complete all as specified and as directed by Engr-in-Charge.
S&F 75mm dia PVC (SWR) bend with or without oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bend with or without oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) branch piece (single Y) equal or unequal with or without oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) branch piece (single Y) equal or unequal with or without oval access door complete all as specified and as directed by Engineer-in-Charge.
S & F 75 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed by Engineer-in-Charge.
S & F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed by Engineer-in-Charge.
S & F 110 mm dia PVC (SWR) vent cowl complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs vitreous China Wash down water closet pan pedastel pattern (EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe complete all as specified & directed by Eng-in-Charge.
Supply and fixing in repair vitreous China squatting pan Orissa pattern, size 580x440mm, white with integral foot rest (excluding flusing cistern and flsh pipe) including provision of lime concrete bedding and making good to the floor, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PVC low level flushing cistern 10 Ltrs capacity with inlet ball valve, float and handles including brackets all as specified and directed by Eng-in-Charge.
S & F in repairs Plastic Water Closet Seat cover, White, Closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous China ware wash hand basin, white flat back of size 550mmx440mm including 15mm bore chromium plated copper alloy pillar tap 32mm brass chromium plated waste fittings with long screw shanks and fly nuts flange end bedded in red led cement and other end fixed rubber plug with rings including CI Brackets cutting for and pinning in ends of brackets or erecting strand etc complete all as specified & directed by Engineer-in Charge.
S&F in repair SS Grating round with or without hole of 100mm size complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PVC flexible connections 15mm dia 600mm long with brass checknuts complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs brass chromium plated Hand shower (Health Faucet)(ABS Body) with 1 Meter long Easy Flex Tube in Chrome Finish& wall Hook complete all as specified and as directed by Engineer-in-Charge.
M&L in repair 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PVC flexible waste pipe 32/40 mm mm dia for wash hand basin/kitchen sink complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs stainless steel sink with drainage board made out of 1.00 mm thick sheet with plug, washers, Ms angle cantilever brackets for suitable size and connecting union to pipe of overall size 915 mm x 460 mm and bowl size 410mm x 330 mm x 160 mm complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs two way bib tap 15 mm bore cast copper alloy Chromium plated with capstan head, screwed down, screwed for iron pipes complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 32mm waste fittings of brass chromium plated and waste coupling of PTMT glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 40 mm waste fittings of brass chromium plated and waste coupling of PTMT glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and as directed by Engineer-in-Charge.
Demolition of precast concrete work/ precast concrete block built in cement mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer-in-Charge.
M&L for laying Plain Cement Concrete (1:4:8) type D2 Nominal mix (using 40mm graded aggregate) for sub base in foundation including formwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 75mm thick Plain Cement Concrete (1:3:6) type C2 using 40mm graded aggregate as in plinth protection including finishing even and smooth with using extra cement, including formwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Plain Cement Concrete (1:3:6) type C2 Nominal mix using 40mm graded aggregate as in surface channels and drain, including formwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for extra for forming finished drain or channel 30 to 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped ends etc. complete all as specified and as directed by Engineer-in-Charge.
Material and labour for setting coat 3mm thick in CM 1:2 ,trowelled to even and smooth finish complete all as specified and as directed by Engineer-in-Charge.
M&L for 40mm thick Plain cement concrete type B1 1:2:4 Nominal mix (20 mm graded stone aggregate) in wearing course/padding concrete including formwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and simillar work horizontal or sloping etc complete all as specified and as directed by Engineer-in-Charge.
M&L for CRS TMT Fe-550 grade bars 10mm dia and over cut to length, bent to shape required incl cranking and hooking ends and binding with MS wire (annealed) of dia not less than 0.90mm complete all as specified and as directed by Engineer-in-Charge.
M & L for Reinforced Cement Concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in slab supported on walls, beams and columns in floors, roofs, landings, deck slab, shelves and like complete all as specified and as directed by Engineer-in-Charge.
M & L for providing Precast cement concrete type B1 1:2:4 (20 mm graded aggregate) and set in cement mortar 1:6 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, hangers, shelves and similar articles with plain faces including form work complete all as specified and as directed by Engineer-in-Charge.
M& L for precast cement concrete block masonary using PCC 1:3:6 type C-1 soild block exceeding 10 cm in width and settng in cement mortar 1:6 straight or curved on plan exceeding 6m mean radius complete all as specified and as directed by Engineer-in-Charge.
M & L for 10 mm thick cement plaster in CM 1:6 on concrete surfaces finished even and smooth complete all as specified and as directed by Engineer-in-Charge.
M & L for applying a coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm over a coat of bituminous primer @ .3 Kg/Sqm complete all as specified and as directed.
Taking down cement plaster on brick or stone wall in any description
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6(Total 15 mm thick) on concrete or brick/block masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only Integral water proofing compound.
M & L for rendering to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, 10mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiles including cement mortar bedding (but not backing) removing serviceable to store and rubbish of the premises, complete all as directed by Engr-in-charge.
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick exc. 0.06 sqm but n.exc 0.11sqm area of each tiles in floor/ steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer-in-Charge.
M&L glazed ceramic coloured tiles 300 X250 X 7mm / 450mm X 300mmx8 thick as in dado / skirting set and and jointed in neat cement slurry and pointed in coloured cement to match as in floor over 10mm thick screed bed in CM (1:4) complete all as specified and as directed by Engineer-in-Charge.
M&L for chequred cement concrete tiles mixed with grey cement and no pigment of size 300x300 x22-25 mm thick set jointed and pointed in neat cement slurry in floors incl 20 mm thick screed in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M& L for Machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and as directed by Engineer-in-Charge.
M & L crushed stone sand cushioning for paver tiles including watering and consolidation complete all as specified and as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-Charge.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
Dismantling posts of any description , including taking out embedded portion and making good disturbed ground complete all as specified and as directed by Engineer-in-Charge.
Excavating in post holes in hard/dense soil n.exc. 0.5 cum and getting out returning, filling in and ramming in layers n.exc. 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good the surface complete all as specified and as directed by Engineer-in-Charge.
M&L Plain Cement Concrete 1:3:6 type C2 Nominal mix (40mm graded aggregate) as in foundation, filling & mass concrete including formwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Mild Steel framed work such as fencing post including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
M&L PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts including dismantling of fencing and fencing post complete all as specified and as directed by Engineer-in-Charge. Note :Mild Steel rod,flat iron and bolts will be measured and paid seperately.
Supply only mild steel screw bolts 10mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing complete all as specified and as directed by Engineer-in-Charge.
Supply only Mild Steel bars for support to chain link fencing complete all as specified and as directed by Engineer-in-Charge.
Supply only Mild Steel Flat iron as in fillets for securing wire mesh including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-410-0 to Fe-310-0 complete all as specified and as directed by Engineer-in-Charge.
M&L for two coats of synthetic enamel paint over a coat of Red oxide primer including preparation of new steel/iron surface of any description n.exc10 cm in width or girth complete all as specified and as directed by Engineer-in-Charge.
M&L Painting two coats of synthetic enamel paint over a coat of red oxide including preparation of new steel surfaces of any description over 10cm in width or grith not other wise complete all as specified and as directed by Engineer-in-Charge.
M&L for Painting one coats of synthetic enamel paint including preparation of old steel surfaces of any description over 10cm in width or grith not other wise described complete all as specified and as directed by Engineer-in-Charge.
M&L preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer-in-Charge.
M&L preparing newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer-in-Charge.
M & L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed by Engineer-in-Charge.
M & L for preparation of surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as directed by the Engineer-in-charge and as per manufacturers instructions.
M & L for Preparation of old painted wall surfaces and applying one coat of acrylic emulsion based premium quality finish exterior antifungal paint all as per manufacturer's instructions complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. all as directed by the Engineer-in-charge and as per manufacturers instructions
Taking down chowkats or frames not exceeding 1.5 Sqm ( without taking off shutters from the frame) including iron mongeries complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm (with shutters and grill (if fixed) without taking off shutters from the frame) including iron mongeries complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any description n. exc. 1 Sqm including builder hardware complete all as specified and as directed by Engineer-in-Charge.
Taking down Shutters of any description exc 1.0 sq. m but not exc 2.00 sqm each including builders hardware complete all as specified and as directed by Engineer-in-Charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engineer-in-Charge.
M&L for Anodised aluminium frame for doors, windows, ventilators and partition with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
S & F in Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge. Note:- (i) Weight of various aluminium sections and handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. (ii) Glass panels, prelaminated particle boards and glass as required shall be measured and paid separately in relevant item of this schedule as "supply only".
Supply only 4 mm Plain sheet glass ordinary quality, in square not exc 0.5 sqm each complete all as specified and directed by Engineer-in-Charge.
Supply only 4 mm figured glass ordinary quality, in square exc 0.5 sqm each complete all as specified and directed by Engineer-in-Charge.
Supply only 12mm thick Prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination fixed as in panels of Aluminium door shutters, partition etc complete all as specified and directed by Engineer-in-Charge.
Allied Trading Company
bansal construction
M/s Pooja Enterprises
M/s Ramesh Lal
DEEPAK AGENCIES
Nirman Construction Company
M/s Sriya Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .