| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹42.4 L+₹3.4 L (8.81%)Rejected-Finance D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.1 L+₹6.1 L (15.7%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹47.8 L+₹8.9 L (22.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 Jan 2024, 5:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINT OF SOLAR WATER HEATER AND CERTAIN MISC WORK AND REPAIR OF CERTAIN WATER SUPPLY MAINT INCL CLEANING REPAIR/ REPLACEMENT OF PVC SERVICE TANK, U/S OLD INLET AND OUTLET PIPE OF PVC/RCC SERVICE TANK ALLIED WORK UNDER GE (WEST) JABALPUR
2023_MES_635090_1
8668/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
7 documents required · 7 mandatory
₹500
GE (West) Jabalpur
₹98,000
19 Feb 2024
1 Jan 2024
3 Feb 2024
2 Jan 2024
29 Jan 2024
15 Jan 2024
2 Jan 2024 - 9 Jan 2024
Amount
Mechanized cleaning and disinfection of Water Storage Tank : 1. Mechanized Dewatering of water storage tank. 2.Removal of sludge lying on the bottom of water storage tank through special sludge pumps. 3.Cleaning of internal walls of water storage tank through High Pressure rotary Jets. 4.Vaccum cleaning of the floor of water storage tank through industrial vaccum cleaners. 5.Spray of H2 O2 inside the tanks as an antibecterial agent. 6. UV radiation of the tank. 7.Spray of bleaching powder in prescribed quantity after final cleaning of the tank. 8.All inlet & out let pipe line should be found no leakage , if any found that should be change at site by the contractor without any extra cost to Govt. Note :- 1. writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete all as specified and directed. 2. Cleaning agency daily take the site from Engineer authority for cleaning of PVC tank of different area/Colony and site clear before evening Supply. 3. Daily feed back given to Engr Authority by cleaning agency. 4. Any tank/ pipe leakage, float valve overflow complaint found by user after tank cleaning, contractor should rectified the defect using serviceable material to satisfaction of users. 5. One day before intimation to users for cleaning of tank.
(a) 500 ltr capacity
(b)1000 ltr capacity
(c) 2000 ltr capacity
(d) 5000 ltr capacity
Dismantling water tanks of capacity 500 Ltr of any description and removing from site all as specified and directed.
Dismantling water tanks of capacity 1000 Ltr of any description and removing from site all as specified and directed.
Dismantling water tanks of capacity 2000 Ltr of any description and removing from site all as specified and directed.
Dismantling water tanks of capacity 5000 Ltr of any description and removing from site all as specified and directed.
Supply, fix & Hoisting and fixing in position and connecting, 500 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. Make :- Prayag/ Sintex /Polycon/ Astral
Supplying , fixing & Hoisting and fixing in position and connecting, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. Make :- Prayag/ Sintex /Polycon/ Astral
Supplying , fixing & Hoisting and fixing in position and connecting, 2000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. Make :- Prayag/ Sintex /Polycon/ Astral
Supplying , fixing & Hoisting and fixing in position and connecting, 5000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. Make :- Prayag/ Sintex /Polycon/ Astral
S&F in repair of 20mm bore Float/ ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for GI pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms) Make :- Prayag / Wilson/ Pearl
S&F in repair of 25mm bore,Float/ ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -690 Gms) Make :- Prayag / Wilson/ Pearl
S&F in repair of 40mm bore,Float/ ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -690 Gms) Make :- Prayag / Wilson/ Pearl
S&F in repair of 15mm bore,Float/ ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -142 Gms) Make :- Prayag / Wilson/ Pearl
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 500 litres capacity tank complete all as specified and directed.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 1000 litres capacity tank complete all as specified and directed.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 2000/5000 litres capacity tank complete all as specified and directed.
Taking down or taking up steel water tubing , galvanised from trenches / walls / floors including all fittings, segregatting and stacking the serviceable pipes and fittings properly at site for re-use all as specified and directed for following bore of pipe :
(a) 15mm dia
(b) 20mm dia
(c) 25mm dia
(d) 40/50mm dia
Re-laying/refixing only old serviceable steel water tubing, galvanised and connections in new or old situation / allignment including all new fittings (on Walls, floors etc, ) of pipe as recovered , including de-scaling /cleaning of pipe (internally and externally) cutting and threading of tubing ends all as specified and directed. of following size :-
(a) 15mm dia
(b) 20mm dia
(c) 25mm dia
(d) 40mm dia
S & F steel water tubing galvanised ,medium grade with all fittings and fixed complete to walls or in floors , trenches (Make : TATA/JINDAL/ Swastik) for bore of pipe following sizes: -
(a) 15mm dia
(b) 20mm dia
(c) 25mm dia
(d) 40mm dia
(e) 50mm dia
S & F in repair gate / globe valves cast copper alloy screwed both end down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed bore of following size : -
( a ) 15 mm bore.
( b ) 20 mm bore.
( c ) 25 mm bore.
(d ) 40 mm bore
(e) 50 mm bore
S&F in replacement tank connector GI 15mm bore complete all as specified and directed.
S&F in replacement tank connector 20 mm bore complete all as specified and directed.
S&F in replacement tank connector 25mm bore complete all as specified and directed.
S&F in replacement tank Connector 40mm bore complete all as specified and directed.
S&F in replcement tank connector 50mm bore complete all as specified and directed.
S&F in repair 20mm bore bib tap cast copper alloywith crutch/buterfly handle screwed for iron pipe complete all as specified. Make - Prayag/Polytuff./ Jaguar
S&F in repair socket, elbow, reducer, nipple, Tee etc of any size or type suitable for GI pipe of bore 15mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair socket, elbow, reducer, nipple, Tee etc of any size or type suitable for GI pipe of bore 20mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair socket, elbow, reducer, nipple, Tee etc of any size or type suitable for GI pipe of bore 25mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair socket, elbow, reducer, nipple, Tee etc of any size or type suitable for GI pipe of bore 40mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair socket, elbow, reducer, nipple, Tee etc of any size or type suitable for GI pipe of bore 50mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair Union of any type suitable for GI pipe of bore 15mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair Union of any type suitable for GI pipe of bore 20mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair Union of any type suitable for GI pipe of bore 25mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair Union of any type suitable for GI pipe of bore 40mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
S&F in repair Union of any type suitable for GI pipe of bore 50mm as per requirement including cutting and threading of GI tubing all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in any type of soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified & directed.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of excavated materials (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
S&F in repair Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 4 Sqmm cable shall be measured as one unit run.
S&F in repairs Sub main wiring with two single core FRLSH PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
S&F in repair Sub main wiring with two single core FRLSH PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 10 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 10 Sqmm & one run of 10 Sqmm cable shall be measured as one unit run.
S&F in replacement non return valve of 15mm size of brass for geyser (weight of valve shall not be less than 400 grams) complete.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make: Legrand cat no :5078 11 or eq in SEIMENS /GE
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand /Seimens/GE
S&F in replacement MCB Single Pole and Neutral 240Volt, 20-40 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand cat no :4086 18 or eq in SEIMENS /GE
S&F in replacement MCB Single Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand /Schneider / Semens
S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified & directed..Make: Legrand cat no :4086 90/92/93/94/95/96 or eq in SEIMENS /GE
S & F in repair steel water tubing galvanised ,medium grade with all fittings and fixed complete to walls or in floors , trenches (Make : TATA/JINDAL/ Swastik) for bore of pipe following sizes: -
(a) 15mm dia
(b) 20mm dia
(c) 25mm dia
S & F in repair gate / globe valves cast copper alloy screwed both end down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed bore of following size : -
( a ) 20 mm bore.
( b ) 25 mm bore.
S&F in repair 20mm bore bib tap cast copper alloywith crutch/buterfly handle screwed for iron pipe complete all as specified.
S & F in repairs hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore
All as described in serial item No. 79 above, but for 20 mm bore
All as described in serial item No. 79 above, but 25 mm bore
Disconnecting electrical connection of solar heating device carefully, dismantling solar panel with water tube (copper) assembly, rubber gas kit, nut bolt biding, aluminum channel and glass carefully and servicing/cleaning with acid & water circulation and wire brush. After servicing reassemble the same and testing. Note:- Minimum servicing period 06 months only complete all a specified and directed.
Supply and fix in replacement of heating elements such as O Ring, Packing any type , flange Nipples for solar water heating system 03/05 KW with rubber gasket for any type of geyser Make : Thita/Teletac or equivalent ISI marked
Supply and fix in replacement thermostat for Solar water heater, AC, SP 250 volts including making necessary connection, ISI marked, complete all as specified and as directed.
Supply & fix in replacement of brass non-return valve 20/15mm dia horizontal/verticle type ISI marked complete all as specified and as directed as per site rquirement. Make : Uttam/Sant/BIR
S & F in repairs Regid non-metallic PVC conduit not less than 20 dia (external ) ISI marked for passing through submains etc of size 20mm dia including of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed
S&F in repairs for fabrication of angle iron frame stand with equal angle of size 50x50x 6 mm suitable for solar water heater and fixing arrangement complete all as specified and as directed.
Supply and fix in replacement of temparature gauge for water heating system ISI marked, complete all as specified and as directed.
Material and labour in replacement of solar water heater glass Tube any size and any type Suitable for 100 to 500 Ltr Capacity of Solar Heater type & Size complete all as specified and directed including collant quiet, absorbing plates ,flow tube , insulation coolant outlet certificate for transmissibly will be provided from approved company (E-In-C Branch make approved list.
Material and labour in replacement of solar glass panel complete all as specified and directed including collant quiet, absorbing plates , flow tube , insulation coolant outlet certificate for transmissibly will be provided from approved company (E-In-C Branch make approved list.
Repair to hot water storage tank of solar water heating system including detecting the leakage, cleaning of inner tank, bracing to leakage portion testing for leakage etc for any type, capacity of solar water heating hot water tank including removing, diamantling, assembling refixing and making water and electric connections complete all as specified and as directed.
Supply & fix in repair XLPE insulated armoured heavy duty electric cable with aluninium conductor 1100 volt grade cross section area 2 core 16 sqmm complete all as specified and as directed.
RP ANAND
Sachdeva Enterprises
mandeka constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .