| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC R O VIJHARA LOWDARA BANDIPORA KASHMIR J K 193502 | BANDIPORA | JAMMU AND KASHMIR | 193502 | L1 | Accepted-AOC Lowest bid found in order | |
| 2 | L2₹45.8 L+₹1.4 L (3.11%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest bid |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
26 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS C/O 56 APO
GE 874 EWS C/O 56 APO
PROVN OF CERTAIN RR SANCTIONED WORK UNDER AGE BR III
2023_MES_604112_2
GE 874/EWS-38/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kupwara
As per NIT and tender documents
7 documents required · 7 mandatory
₹500
GE 874 EWS
₹80,000
Yes
10 Nov 2023
31 Jul 2023
28 Aug 2023
31 Jul 2023
26 Aug 2023
7 Aug 2023
Amount
BR and EM Portion
M&L for excavation over area n.exc 1.50m deep and getting out in any type of soil.
M & L for Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil all as specified.
Removing excavated soil material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point used the same in embankment of soil for retaining wall all as specified and directed.
M & L for Brickwork with sub class 'B' Bricks built in CM 1:4, straight or curved on plan exc. 6m mean radius all as specified and directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces or other than fair face of brick work in CM 1:4 and finishing all as specified and directed by Engr In Charge.
M&L Prepartion of plasterd surfaces of wall and applying two coats of cement base paint on new surfaces as specified
M&L 50mm thick wall panel made 0.5mm thick hot dipped galvanised steel sheet on both side with 50 mm thick .layer of rigid cfc free closed cell polyurethane foam with tongue and groove joint incl camp lock system for interlocking fixed on based chanel 30 x65 x1.25 mm thick density of foam shall be 40 Kg /cum (+-2kg/cum) the panel shall be precoated as approved by AO all as specified and directed by Engr -In -Charge .
M & L 0.5 mm colour coated steel profile sheet ( for roof ) fixed with hot dipped Zink coat hexagonal washer head fasteners. The ridge shall be cover with same colour coated sheet upto bottom cord of truss projection shall be 450 mm wide all as specified and directed by Engr -In -Charge .
M & L 40 mm thick for ceiling puff insulated panel made of .5 mm thick hot dipped galvanised sheet both side with 40 mm thick rigid polyurethane with tounge and groov joint for interlocking to fixed with inverted crca tee section 50x50x5 mm thick and L section of 50 x50x5 mm thick to roof trusses all as specified and directed by Engr -In -Charge .
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S & F Butt hinges, 100 mm long cast brass, with mild steel hingepin, bright polished andfixed, type B-11.
S & F Aluminium anodised, 200 mm long barrel tower bolts of extruded section and fixed
S & F Aluminium anodised, 150 mm long barrel tower bolts of extruded section and fixed as specified
M & L for Roof trusses (framed), Fe 410 -W (Gde- E- 250) quality- A trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed by Engr In Charge
Mild steel Plates (plain or chequered) Fe 410 -W (Gde- E- 250) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as specified
M & L for two coat of painting on new surfaces of any discription over 10 cm in width or girth over a coat of pink primer as specified
M & L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long Ditto, but length of bolt exc 10cm and n exc 15cm long all as specified
M & L for Cement concrete type D2 1 :4 :8 (40 mm graded aggregate) in foundations, filling and mass concrete
M & L for Walling of squared rubble, built in CM 1:6 regular coursed, well bonded, bedded and solidly hearted, aas specified.
Providing, cement concrete in roof Type B1 1:2:4 20 mm graded aggregate kerbs or mud stops, rounded orchamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not providedfor in Item , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
Providing precast Type C 1 1:3:6 using 20 mm aggregate ce- ment concrete in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry),string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match as specified
M&L for RCC Nominal Mix 1:2:4 B1 (using 20 mm graded aggregate )Beams, cantilevers, bressummers, lintels over 1.5m span as specified
Formwork to sides of concrete Fair finished surfacr of concrete flate foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter as specified
Formwork to sides and soffits of Fair finished surfacr of concrete flate floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M & L Mild steel bars 10mm TMT bars dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as specified
M & L Mild steel bars 10mm TMT bars dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders as specified
S & F Pre-painted galvaniumealuminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L Moorum/red bajri filling in floors or paving, laid in layers n exc. 15 cm thick, spread, leveled and rammed including watering
M&L hard core of guge in exc. 63mm deposited spread and levelled in layersn.exc 15cm thick watered and rammed to a true surface complete all as specified.
M & L for Cement concrete D-2, 1:4:8 Type 40 mm graded aggregate , 75 mm thick as in sub base nover rammed earth all as specified
M & L for Cement concrete B-1, 1:2:4 Type 20 mm graded aggregate , 25 mm thick as in sub base over rammed earth all as specified
M & L for Screed bed or bedding layer of mortar 15 mm in CM 1 :4 under floor tiles thick for laying floor finishes
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) colour tiles area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface.
M & L for Plinth protection 75 mm thick in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth without using extra cement and providing joints through out the thickness of plinth protection, filled with mastic filling comprising one part of bituman 85/25 grade and three parts of sand by weight all as directed at site.
Mild steel sliding door bolts, 250 mm long plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed
S&F rotational moulded polythene water storage tank (Cylindrical vertical withclosed top)hoisted and fixed in position of 1000 ltrs capacity fixed with PVC tank nipples,complete all as specified in SSR Part I.
S&F rotational moulded polythene water storage tank (Cylindrical vertical withclosed top)hoisted and fixed in position of 500 ltrs capacity fixed with PVC tank nipples,complete all as specified in SSR Part I.
S&F tubing galvanized iron medium grade with all fitting laid in concealed , trenches, floors or fixed to walls or ceiling, in any length, bore of pipe 15mm.
M & L for Vitreous china wash basin, vertically mounted fancy bowl flat back size 550 x 400 m including waste pipe and coupling 32mm for basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including MS brackets& waste Pipe complete.
M&L for Vitreous china squatting Pan "Orrisa Pattern" size 580 x 440mm white with integral foot rests incl flush pipe of PVC 32mm dia for low level cistern fixed in repair complete all as specified
S&F PVC valve-less symphonic action type flushing cistern, low level white with inlet ball valve float and handle incl brackets (10 Ltr) capacity fixed in repair complete all as specified and directed.
S&F PVC connection 15mm dia and 600mm long with PTMT nuts and washer complete all as specified.
M & L for CP Pillar taps, with capstan head chromium plated 15 mm bore fancy type.
Bib tap cast copper alloy chromium plated fancy type with crutch of butterfly handle, screwed down, screwed for iron pipe of for brass ferrule of 15mm bore (ISI marked).
Grating doom 100mm dia of PTMT (Minimum weight 25gms
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete omplete with glazing bars, dove tailed or welded including one shop coat of zinc chromites primer complete all as specified and directed.
S&F Sheet glass ordinary quality 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, in repairs, complete all as specified and as directed.
Construction of On site LLDPE septic tank for 10 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete as specified
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth as specified
M & L Concrete bed to drain pipes including 150 mm packing under, and haunching against the sides of pipes after they are laid and tested; in all as specified
M & L for Sail-glazed stoneware drain pipes 150 mm laid in trenches and jointed as specified
M&L for PVC (SWR) vent cowl for 75 mm dia all as specified.
Returning and filling incl spreading leveling watering and well ramming in layers n.exc 25 cm in soft soil all as specified.
M&L RCC M-25 (Design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete
M&L RCC M-25 (Design mix) as in Columns, pillars, piers, posts and struts.
Damp proof course to horizontal or vertical surfaces in PCC 1:2:4 type Bo 40mm thick including necessary formwork all as specified and directed
Supply only Integral water proofing compound for damp proof course all as specified and directed.
M&L Brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in CM 1:6
Preparation of newly surfaces of steel over 10cm width or girth and applying two coats of synthetic enamel paint overa coat of red oxide primer all as specified and directed.
M&L Rendering 10mm thick plaster on internal face of wall in CM 1:6 finished even and smooth without using extra cement.
S&F 4mm thick plywood (03 Nos of ply),grade BWR type BB fixed with nails to timber frame work as in ceiling, complete all as specified.
S&F Plain fillets of exc. 3 & n exc. 6 Sqcm, square ,rectangular or triangular in section , clean swan, secured nails.
M&L Sand filling under floors or in foundation including watering and consolidation
Material and labour for PCC 1:2:4 type B1 40mm thick as in floor all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey on 15 mm thick screed bed in c:m 1:4 over 25mm thick PCC 1:2:4 type Bo (using 12.50 mm graded crushed stone agg)
M&L for Machine cut kota stone slab flooring 20-25 mm thick as on vertical surfaces such as skirting /dados over 15 mm rendering in CM 1:4.
S & F, MS works as in hold fast confirming to Fe 410-0 or Fe 310-0.
Material and labour for 2nd class soft wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
Flush shutters with particle board core 40mm thick , solid core construction, with block board core and plywood face panels, commercial type on both sides
Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
S&F But hinges, extruded aluminium alloy with galvanised mild steel hing pin, anodised and fixed100mm
M&L Aluminium handles, cast type, anodised 150mm
S&F Floor door stoper Aluminium 140 mm long
Material and labour for preparation of newly plastered surfaces of wall and applying three coats of white wash on wall.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Gradewith grey cement and pigment all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete
Rolling and consolidating formation surface in cutting with power roller exc 8 tonne and n exc 12 tonne complete all as specified.
M&L 150mm thick PCC 1:4:8 type D-2 as in sub base, floor complete all as specified
M & L PCC 100mm thick type B-2, 1:2:4 ( Using 20 mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement and making impressions of expanded metal, whilst the concrete is green.
M&L for form work to edges of concrete flats, treads, breaks in floors window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10cm but n exc 20cm wide.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound and filling with sealing compound grade A
Forming 12mm thick expansion joint filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade 'B'.(thickness of concrete slab 150mm)
M& L for 38mm thick aluminium dividing strips 5mm thick inserted in position confirmed to design as specified.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC (FR-LS-H) insulated un-sheathed copper conductor single core multi stranded flexible cable (green color) as earth lead in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/ fan point including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per item above but wiring with 1.5 sqmm copper wire ( FR-LS-H) and 1.5 sqmm earth wire for switch socket combination 3 pin 5 amps on independent board.
All as per item above but wiring with 1.5 sqmm copper wire ( FR-LS-H) and 1.5 sqmm earth wire for switch socket combination 3 pin 5 amps on the same board.
All as per item above but wiring with 2.5 sqmm copper wire ( FR-LS-H) and 1.5 sqmm earth wire for switch socket combination 6 pin 15 amps on independent board.
S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed.
S & F switch socket combination 5 pin 16A, flush type .
S & F switch socket combination 3 pin 5A, flush type .
S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 way incl blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed.
S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 4 way incl blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed.
S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, all as specified and as directed by Engr -in-Charge.
S & F of MCB SPN, 240volt, 40 to 63 Amp capacity, 10 KA, 'C' curve .all as specified and as directed by Engr -in-Charge.
S&F LED, 20 Watts, 4 ft, fittings complete with all accesories for mounting light fittings complete with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body.
Supply and fix ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body.
M & L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings
Supply and fix LED Bulb 9 Watt all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge lead of the platenot less than 1.5 mtr below normal ground level, connected galvanised earrth lead wire 4.0mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shoen in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
S&F 09W/10W Bulk head liminiares including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F Exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230v , 50HZ , RPM 1200, Copper winding of sweep 300mm, with 2 years warrenty.
Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with solid/multi-stranded aluminium conductor cable, of size 10 Sqmm 2 Core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following sizes:-Make: Havells,Polycab or equivalent make as approved by GE
Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with solid/multi-stranded aluminium conductor cable, of size 16 Sqmm 2 Core laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following sizes:-Make: Havells,Polycab or equivalent make as approved by GE
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation ,laying of cables/pipes/poles etc., and getting out in hard/densesoil complete all as specified and directed.
All as per item above but exc 1.50m but n.exc 3.0m deep complete all as specified and directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed by Engineer-in-charge. Note:-Punned thickness only shall be measured and paid.
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-charge.
Supplying and fixing, light grade, Galvanised mild steel pipe / tubing, of 40 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction of following sizes:-. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ):-
Supplying and fixing, light grade, Galvanised mild steel pipe / tubing, of 50 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction of following sizes:-. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ):-
Cutting,threading and joining of existing GI pipe line of 20mm dia and inserting suitable tee for taking branch connection all asspecified and directed by the Engr-in-charge
Supply and laid in trenches pipe galvanized 20 mm dia medium grade complete incl fitting such as bends, elbows, tees, short pieces, connectors, back nuts, caps, plugs and unions etc .
Supply and fixing 20 mm gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe suitable for 20 mm dia pipe.
Supply and fixing 15mm Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed all as specified and directed.
1100 volts grade heavy duty PVC Sheathed FLAT twin core cable of size 10 Sqmm, PVC insulated, aluminium multi-stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed by Engineer-In-Charge of make of Havells/ Polycab/ Finolex/ KEI.
M/S BEE AAY CONSTRUCTIONS
Bidder Name
M/S BEE AAY CONSTRUCTIONS
M/s Shamas Parwaiz Bhat
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .