Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 14 147 VASUNDHRA GHAZIABAD SECTOR 14 VASUNDHRA VASUNDHRA GHAZIABAD UTTAR PRADESH 201012 | GHAZIABAD | UTTAR PRADESH | 201012 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹24.1 L
EMD Value
₹24,070
Closing Date
19 Oct 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
16 NOS WORK STRENGTHENING OF 33 KV SUBSTATION UNDER EUDD I AND V AND VII NOIDA
2023_PVVNL_842985_1
46/EUDC-I/2023-24/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
UNDER EUDD-I/V/VII, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE, EUDD-I, NOIDA
₹24,070
20 Oct 2023
25 Sept 2023
19 Oct 2023
25 Sept 2023
19 Oct 2023
25 Sept 2023
Amount
Supply and Installation of following item / material in place of damaged item / material with providing and fixing of required galvanised clamps, nuts & bolts etc. by the contractor complete in all respect as per RESPO norms at various 33/11 KV Sub-stations in area of EUDD-I/V/VII, Noida as per following (MATERIAL SUPPLY FROM THE PVVNL APPROVED VENDORS AS PER GTP APPROVED) :-
33 KV Bus Isolator 800 A,
33 KV Lightening Arrestor.
33 KV post Isolator set (3 Nos.)
Structure for 33 KV post Isolator
Structure for 33 KV Bus Isolator
Nut & bolts off size, clamp etc.
Control Cable 4x2.5 Sq.mm.
Control Cable 2x2.5 Sq.mm.
33 KV Fuse set 10 MVA T/F
Wiring & Testing of 11 KV VCB
Water level pipe earthing 180 Feet of power T/F with M.S. earthing strips of best quality (ISI mark) as per RESPO norms. (all material will be provided by the contractor for Earthing).
Making plinth & foundation of 33 KV VCB.
WORK REPLACEMENT OF OLD & DAMAGED EXISTING 33 KV / 11 KV V.C.B. AND CONTROL PANEL WITH NEW V.C.B. AND CONTROL PANEL AT VARIOUS 33/11 KV S/S UNDER EUDD-I/V/VII, NOIDA:-
CARRIAGE OF NEW 33 KV Control & relay pannel for double T/F (01 No.), 11 KV VCB I/C CTR 600/300/5A, 350 MVA, 24 Volt (05 Nos.), 11 KV VCB O/G CTR 200/100/5A, 350 MVA, 24 Volt (09 Nos.), 11 KV VCB O/G CTR 400/200/5A (09 Nos.), 11 KV Bus Coupler 350 MVA (03 Nos.), 33 KV Control Pannel Double T/F (06 Nos.), 33 KV Control Pannel Single T/F (02 Nos.) FROM GHAZIABAD/ SHAHIBABAD/NOIDA/JE STORE TO SITE OF WORK WITH SAFE LOADING AND UNLOADING AT BOTH ENDS.
LABOUR CHARGES FOR REPLACEMENT OF 33 KV Control & relay pannel for double T/F (01 No.), 11 KV VCB I/C CTR 600/300/5A, 350 MVA, 24 Volt (05 Nos.), 11 KV VCB O/G CTR 200/100/5A, 350 MVA, 24 Volt (09 Nos.), 11 KV VCB O/G CTR 400/200/5A (09 Nos.), 11 KV Bus Coupler 350 MVA (03 Nos.), 33 KV Control Pannel Double T/F (06 Nos.), 33 KV Control Pannel Single T/F (02 Nos.) WITH ALL ACCESSORIES AND ERRECTION OF ABOVE NEW 33 KV Control & relay pannel for double T/F (01 No.), 11 KV VCB I/C CTR 600/300/5A, 350 MVA, 24 Volt (05 Nos.), 11 KV VCB O/G CTR 200/100/5A, 350 MVA, 24 Volt (09 Nos.), 11 KV VCB O/G CTR 400/200/5A (09 Nos.), 11 KV Bus Coupler 350 MVA (03 Nos.), 33 KV Control Pannel Double T/F (06 Nos.), 33 KV Control Pannel Single T/F (02 Nos.) WITH REMOVING AND RECONNECTING 33 KV / 11 KV INCOMING, OUTGOING, CONTROL PANNEL AND BUS COUPLER CABLES, REMOVING AND REFIXING OF EARTHING AND WIRING AS REQUIRED IN VCB, CONTROL PANNEL AND BUS COUPLER, ALL TESTING OF NEW VCB, CONTROL PANNEL AND BUS COUPLER ETC WITH PROPER SAFETY TO COMPLETE THE WORK ETC IN ALL RESPECT.
CARRIAGE OF 33 KV VCB with Double T/F Control Pannel and CT 200/100/1A FROM GHAZIABAD/ SHAHIBABAD/NOIDA/JE STORE TO SITE OF WORK WITH SAFE LOADING AND UNLOADING AT BOTH ENDS :- (i) 33 KV VCB. (ii) Control Pannel I/C for 33 KV Single T/F. (iii) CT 200/100/1-1/A. (iv) Steel Structure
LABOUR CHARGES FOR REPLACEMENT OF 33 KV VCB with Double T/F Control Pannel and CT 200/100/1A WITH ALL ACCESSORIES AND ERRECTION OF ABOVE NEW WITH REMOVING AND RECONNECTING 33 KV KV INCOMING/OUTGOING CABLES, REMOVING AND REFIXING OF EARTHING AND WIRING AS REQUIRED IN VCB ALL TESTING OF NEW VCB AND PANNEL ETC WITH PROPER SAFETY TO COMPLETE THE WORK ETC IN ALL RESPECT. (i) 33 KV VCB. (ii) Control Pannel I/C for 33 KV Single T/F. (iii) CT 200/100/1-1/A. (iv) Steel Structure
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR SWITCHGEAR / POWER T/F (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.) :-
Providing of earth elctrode for chemical earthing Pipe in pipe type proper hot deep galvanization dia 50 mm length 3 mtr - 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for SWITCHGEAR / POWER T/F installed at Above 33/11 KV Substation .
Providing and fixing of GI strip of size 32 mm x 6 mm suitable for SWITCHGEAR / POWER T/F installed at Above 33/11 KV Substation .
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
DISMANTLING & CARRIAGE OF DAMAGED ITEMS / MATERIAL FROM VARIOUS 33/11 KV S/S TO JE STORE / CENTRAL STORE & PROPER STACKING WITH LOADING & UNLOADING AS PER FOLLOWING.
Damaged 33 KV Bus Isolator
Damaged 33 KV Outdoor VCB
Damaged 33 KV Control & relay Pannel Damaged
33 KV Outdoor CT damaged
33 KV Control Pannel damaged
11 KV VCB (Old & Damaged)
Old & Damaged Bus Coupler
P R POWER SOLUTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .