| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Bring Lowest | |
| 2 | L2₹27.6 L+₹20,879.50 (0.76%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹28.6 L+₹1.2 L (4.41%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹33.8 L+₹6.3 L (23.1%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents not fulfilling MES criteria. |
Tender Value
₹33.2 L
EMD Value
₹66,400
Closing Date
7 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-32/2022-2023 ADDN / ALTN TO EXISTING SEWAGE LINE IN SECTOR D1 AND OTHER SANCTIONED WORKS AT CHANDIMANDIR
2022_MES_529559_4
GE/CHM-32/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer
₹66,400
Yes
13 Dec 2022
17 Oct 2022
14 Nov 2022
17 Oct 2022
7 Nov 2022
24 Oct 2022
Amount
Demolition of plain cement concrete in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware/RCC pipe) internal dia of pipe 150mm, set in cement mortar including PCC haunching complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware/RCC pipe) internal dia of pipe 200mm, set in cement mortar including PCC haunching complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware/RCC pipe) internal dia of pipe 300mm, set in cement mortar including PCC haunching complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately.
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified.
Excavation in trenches in any type of soil exceeding 1.5 metre but not exceeding 3 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified and directed.
Excavation in trenches in any type of soil exceeding 3 metre but not exceeding 4.50 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified and directed.
Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in any position like haunching,benching, coping,kerbs, mud stops etc, complete all as specified & directed.
Material and labour for brick work with sub class ‘B’ bricks of class designation 7.5, all as per IS-1077-1992 (minimum compressive strength of brick 75 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 , complete all as specified & directed.
All as per serial item No. 14 here-in-before but except bricks. (using old serviceable bricks)
Rendering 15mm thick in cement plaster in cement and sand mortar 1:4 over brick work or concrete surfaces , mixing of mortar with water proofing compound, finished even and smooth without using extra cement , complete all as specified and directed. NOTE : WPC shall be mixed as per manufacturer instructions and WPC shall be measured and paid separately as “Supply only”
Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after the pipe are laid and tested , complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipes after the pipe are laid and tested , complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in bed to drain pipes of 300mm bore including packing under and haunching against the sides of pipes after the pipe are laid and tested , complete all as specified and directed.
RCC pipes class NP-2 of 150mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested , complete all as specified and directed.
RCC pipes class NP-2 of 200mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested , complete all as specified and directed.
RCC pipes class NP-2 of 300mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested , complete all as specified and directed.
Salt glazed stoneware drain pipe, grade ‘A’ 100mm bore, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade ,complete all as specified and directed.
Salt glazed stoneware drain pipe, grade ‘A’ 150mm bore, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade ,complete all as specified and directed.
Salt glazed stoneware drain pipe, grade ‘A’ 200mm bore, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade ,complete all as specified and directed.
Salt glazed stoneware drain pipe, grade ‘A’ 300mm bore, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade ,complete all as specified and directed.
PVC (SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors / fixed to walls etc including necessary fittings,sealant etc ,complete all as specified and directed.
PVC (SWR) pipe, 75mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors / fixed to walls etc including necessary fittings,sealant etc ,complete all as specified and directed.
110mm bore PVC (SWR) bend any radius, complete all as specified and directed.
75mm bore PVC (SWR) bend any radius, complete all as specified and directed.
110mm bore PVC (SWR) junction single, (Single T) equal or unequal, all as specified and directed.
75mm bore PVC (SWR) junction single, (Single T) equal or unequal, all as specified and directed.
PVC (SWR) reducer 125mm x 110mm, all as specified and directed.
Providing precast reinforced cement concrete (type B1 , 1:2:4 using 20mm graded aggregate) set in cement mortar (1:4) as in manhole covers, all as specified.
MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia all as directed and specified and directed.
Cutting into existing manholes for connecting new drain pipe of 150mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required, all as specified and directed.
Cutting into existing manholes for connecting new drain pipe of 200mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required, all as specified and directed.
Cutting into existing manholes for connecting new drain pipe of 300mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required, all as specified and directed.
Salt glazed stone ware gully trap, square or round mouthed, type ‘P’ 100mmX 100mm, including provision of C.I grating over the trap and embedding the trap in PCC 1:3:6 type C-2 block of size 30cm x 30cm x 45cm deep ,fixed as in repairs, complete all as specified and directed.
Salt glazed stoneware gully traps, square or round mouthed, any type of size 150mm x 100mm, all as specified and directed.
Cleaning and clearing of underground sewage line upto 200 mm bore pipe including manholes by taking off manhole covers and re-fixing the same after cleaning of any description, at any depth below ground level , removing any type of blockage including de-silting and de-chocking manually by rodding and flushing after cleaning ,clearing of manholes and all as directed by Engineer-in-Charge.
All as per serial item No 41 herein before but 200 mm to 300mm bore pipe.
Bands, rungs, straps, supports or stays for rainwater, ventilating pipes including bolts if required, hooks (stay), heavy for large gates,hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts,wall ties, hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165, all as specified and directed.
Extra for forming fair finished drain or channel n. exc 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mi tred/stopped ends etc, all as specified and directed.
Dewatering of septic tank and manholes of any size and cleaning by taking out mud/sludge from septic tanks and manholes of any depth, in foul conditions and confined places, getting out and removing the sludge to a distance exc 250 m and n.exc 500 m and deposited where directed in and including borrow pits and covering the borrow pits with 10 cms thick layer of soil, sprinkling with lime powder, complete all as specified and directed. Note : Net contents of sludge shall be measured at the time of removal and paid. Quoted rate of tenderer is deemed to be inclusive of dewatering as required and nothing extra shall be admissible to the contractor on this account.
Two coats of white wash on wall surfaces including preparation of new surfaces ,complete all as specified and directed
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade , with grey cement and no pigment laid over and including 25 cms thick layer of sand, all as specified and directed.
75mm thick PCC 1:4:8 type D-2 (using 40m graded crushed stone aggregate) as in sub base flooring, finished even and fair, all as specified and directed.
Supply only Integral water proofing compound, ISI marked, complete all as specified and directed.
Cutting holes in brick walls exc. one brick but n.exc. two bricks, built in cement mortar and making good the surfaces by cement mortar (1:3) or PCC (1:2:4) type B-1, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 , complete all as specified & directed by Engineer-in-Charge.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified , fixed in repairs, all as specified.
Non skid ceramic coloured tiles, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 Square metre but not exceeding 0.36 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Roughening surface of old concrete floor by picking, seeping clean and washing down with water to remove dust etc incuding brushing neat cement slurry with 3.0kg of cement per Sqm, complete all as specified and directed.
Rendering 15mm thick in cement plaster in cement and sand mortar 1:4 over on irregular faces of wall or concrete surfaces , finished even and smooth without using extra cement , complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Material and Labour two coats of synthetic enameled paint on steel and iron surfaces over 10 cm width or girth over a coat of red oxide including preparation of new surfaces complete all as specified & directed.
Supply, install, testing and commissioning of grid of minimum 3 Sealed maintenance free chemical earthing electrode, each individual earthing electrode having following specification :- (a) Diameter of the pipe-80 mm, thickness of the pipe-3.9 mm, Length of the pipe- 3000mm, Galvanised thickness- 80-100 micron, Type of galvanising- Hot dipped , Chemical used in the pipe- High conductive and crystalline conductive mixture ( CCM) , Chemical approx weight 12 Kg. (b) Ground back filled compound 50 kg as conforming to IS 3043 properly mixed the after all around the electrode. (c) Necessary boring in ground in any type of strata/soil and connecting to test point. (d) Construction of brick masonry earth pit of internal size 30cm x 30cm and 30cm deep including finishing work and fixing of CI cover as manufacturer specification complete all as specified and directed (e) Testing for proper working. NOTE- Earth resistance at each grid should be less than 1 ohm at test point .
Supply and fix copper strip of size 20mm x 3.15mm laid on wall / floor complete all as specified and directed.
Supply and laying 40mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Pt II with Anti Rodent and non flame propagating properties of approved color with fitting for cable protection complete all as specified and directed. Make : FINOLEX/SFMC/ SUPREME/ DUTRON
Supply and installed hi wall split units indoor/ outdoor, AC single phase 230 volts, 50 hz complete with cordless remort control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR including making provision for hoisting outdoor unit and making rain protection complete all as specified and directed.
Supply and installed hi wall split units indoor/ outdoor, AC single phase 230 volts, 50 hz complete with cordless remort control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2 TR including making provision for hoisting outdoor unit and making rain protection complete all as specified and directed.
Supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5.0 KVA complete all as specified and directed.
Supply and fix sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces after taking out old unserviceable sub main wiring complete by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 4 sqmm and one single core of 04 sqmm cable along with PVC conduit shall be considered as 1 running metre. (ii) cutting chases and PVC conduit will be measured and paid separtely
Supply and fixing Single pole and neutral enclosure (industrial type) with a two pin and earth plugm socket complete with one single pole MCB 20 Amp,240V flush type complet all as specified and directed
MS GURENDER SINGH
M/S CHOPRA & COMPANY
M/s Krishan Aggarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .