Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹13.9 L+₹23,295 (1.70%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹14.0 L+₹26,245 (1.92%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹14.8 L+₹1.1 L (8.01%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹15.1 L+₹1.4 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
10 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
PROVN OF CERTAIN REVENUE AND MINOR WORKS AT LGJ MIL STN
2024_MES_637309_1
8934-54/ge/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender doucments
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹39,000
Yes
14 Mar 2024
13 Jan 2024
12 Feb 2024
13 Jan 2024
10 Feb 2024
27 Jan 2024
Amount
Demoliton of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) all as specified
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles all as directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) all as specified & directed.
Dismantling of Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed by Engr-in-charge.
M&L for 40mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 complete all as specified & directed by Engr-in-Charge.
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen/ M/S TORCHTAR MEMBRANE Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
M&L 40mm thick brick tiles laid flat joints grouted flush in cement mortar (1:3) bedded in 15mm th cement morter (1:6) mixed with 5% of curde oil by weight of cement complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster or cement lime plaster /terrazoo on brick / stone walls including raking out joints, hacking for key, scrubbing down with water all as directed
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 on wall finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finishedeven and smooth without using extra cement complete all as specified & directed.
M&L for two coats of acrylic distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty over a coat of primer including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
M&L for three coats of white wash on newly plastered surfaces of wall incl preparation etc. complete all as specified and directed by Engr-in-charge.
M&L for three coats of white wash on newly plastered surfaces of Ceiling incl preparation etc. complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surface of walls and applying two coats of cement base paint complete all as specified & directed
M&L for preparation of Old plastered surface of walls and applying one coats of cement base paint complete all as specified & directed
M&L for complete removal of existing treatment and two coats of white wash on including preparation of old surfaces of wall complete all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment and applying two coats acrylic distemper over a coats of primer over 3 mm thick wall care putty and including preparation of surface complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick cement concrete 1:2:4 type B-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar complete all as specified and as directed.
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bedding in cement mortar 1:6, all as specified and directed.
M & L Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed.
M & L for rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting of other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel handing door fitttings (exclusive or steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing confirming to Fe-410 W (Gde-E-250) complete all as specified and directed by Engr-in-charge.
S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for 35 mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
S & F for Aluminium anodised (Powder coated) Three track sliding window frame with shutters (two glazed and one gauged shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for frame (i) Top and verticals 92 x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) 'A' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick(iii) 'H' section 41 x 20 x 1.10 mm thick Make: Jindal or equivalent sections of Hindalco.
S&F for 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and directed.
S&F for 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed.
S&F for 100 mm long butt hinge, medium weight, cold rolled mild steel all as specified and directed.
S&F for 300 mm long mild steel sliding door bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F for 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed.
S&F for stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as directed.
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or Fe 165 complete all as specified and as directed
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of read oxide & finish with two coats of synthetic enamel paint ordinary tint all as spefified and directed by Engr-in-Charge.
S&F in repairs stainless steel curtain rods, standrad quality, not less than 28mm dia with heads , etc. complete all as specified and directed by Engr-in-Charge.
M & L for precast cement concrete louvres and jallies of type (1:2:4) B0 using 12.50 mm graded stone aggregate, 25 mm thick (measured solid) including all mouldings complete all as specified & directed
M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in sub base below floors and paving etc all specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with oversand cushion all as specified and directed.
Dismantling of water tank exc 500 but n. exc. 1000 litre capacity any type and remove from site complete all as specified and directed by Engineer-in-Charge.
S&F for Rotational moulded polythene water storage tank 1000 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I including 20 mm bore PTMT float valve, connection nipple 2 Nos complete all as specified and directed by Engineer-in-Charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per srl item No 47 above but 20mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in dado/skirting over and including 10 mm thick rendering on vertical surface in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed.
Dismantling asbestos cement (corrugated / semi corrugated) sheets including ridges as in roof covering all as specified & directed.
S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Make : JSW & equivalent.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping & benching to main holes, drains etc all specified and directed.
Supply, installation, testing and commissioning of maintenance free earth grid (grounding) interconnected two earth electrode of size 85 mm dia x 3 mtr long each. Metal conductor of electrode shall be Cu bounded MS strip of 50x6mm. Cu bounding of MS rod/strip should be min 250 microns. Earth electrode 85mm dia x 3 mtr long shall be placed in augured bore hole and embadding of interconnected strip shall be cast in high purity electrically conductive granuler material having ultra low resistive value of 0.001 Ohm-m. resulting in increase of the effective surface area of the earth grid to lower the earth resistance. Conductive earth enhancing material mixed with cement in the ratio 3:1 which should not leach chemicals into the adjacent soil or or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal components of the earthing system, All hardware like nuts, bolts and washers should be of stainless steel. Electrode should withstand fault current upto 35 KA for 1 second. Electrodes top terminal be sealed permanently packed with conductive concrete and test link of Cu bonded MS/copper of size 50mm x 6mm x 200mm shall be taken out to connect the equipment. Test certificate of NABL laboratory shall be submitted by the contractor. Making RCC pit and cover including brazzing of all the joints upto the test point complete including taking out/dismantling old unserviceable conventional earthing accessories, strip, pipe, test point etc complete all as specified and and as directed by Engineer-in-charge Make :- Elancrete/ Vasconite/ Electroguide Note :- (i) Test certificate of earthing material for fault current, rohhs compliance, resistivity value from NABL Certified/ CPRI lab is must and shall be submitted by the contractor and it has to be verified by GE. (ii) Test Reports should not be more than 5 years old. (iii) No pre cast electrodes to be used. (iv) Earth testing arrangement at site should be done by the contractor as per direction of Engineer-in-charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good distrubed surfaces of walls and floors etc to match with the existing all as specifided and directed.
M&L for concealed Point wiring for One Light point controlled by one, one way switch with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS sunken sheet metal box with modular sheet top cover of required module for mounting switches, sockets etc complete all as specified. complete all as specified and directed by Engr-in-Charge. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour complete all as specified and directed by Engr-in-Charge. .
,--ditto--- all as per Serial item No 61 above, but for One 3 pin 5 amps switch socket on same board with other switches complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 61 above, but for One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engr-in-Charge.
,---ditto-- all as per item No. 61 above but point wiring with 4 sqmm multi stranded conductor cable and 4 sqmm unsheathed copper conductor earth wire for two in one 5 pin 15 Amp socket outlet on indep board.
Supply & fixing switch piano type flush button single pole one way 5/6 Amps, 230 volts all as specified & directed.
Supply and fix piano socket 2 in 1, 2/3 pin 5 amp flush type 240 volts AC complet all as specified and as directed
Supply and fix socket 2 in 1, 3 pin 5 amp and 15 amp flush type 240 volts AC complet all as specified and as directed
Supply and fix piano swith 15 amp flush type 240 Volts AC complet all as specified and as directed
Supply & fix batton integrated LED light fitting 1 x20 integral sleek polycarbonate LED channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVCblocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete all as specified and directed. Note : (i) with lumen efficiency in excess of 100 Lumans per watt and driver effeciency >85% (withpf>0.95) (ii) CRI >80 (iii) The warranty of LED fittings is 02 years after completion of the liability period
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge.
S & F in repair factory made sheet metal distribution boards, SPN, 4 way double door; protection class IP-30 suitable for mounting MCB/ conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed.
S & F MCBs 10 KA confirm to IS-8828 : 1996, IEC 898 : 1995 ruputing capacity of SP 6-32 Amp all as specified and directed by Engineer-in-Charge
S & F MCBs DP SPN 240 volt 40 amp 10 KA all as specified and directed by Engineer-in-Charge
Supply & Fix in repair exhaust fan, steel body AC single phase 230V of size 300 mm sweep with blades and frame and louvers all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
M & L for Sub main wiring with two single core PVC sheathed insulated cable of 6 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including PVC rigid conduit of adequate size of conduit and junction boxes,terminal boxs,terminal 6 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor. (Two run of single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length) complete all as specified and directed.
S & F LED building security light fitting 45 watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one complete all as specified and directed
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
KHANNA CONSTRUCTIONS
PAREEK AND COMPANY
M/s Karan Builders
GOYAL ENTERPRISES
THAKURJI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .