Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance KOTHAR MAJALI SADASHIVGAD KARWAR UTTARA KANNADA 581360 | KARWAR | UTTARA KANNADA | KARNATAKA | 581360 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
12 Feb 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(SB) Karwar
GE(SB) Karwar Naval Base Karwar Karnataka 581308
MANNING AND OPERATION OF MAIN RECEIVING DISTRIBUTION SUBSTATION DSS 16 AT NK BAIL SITE E UNDER GESB KARWAR
2021_MES_418678_1
3002/42/E3 dt 02 Feb 2021
Limited
Job Works
Works
30 days
GE(SB) Karwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
16 Feb 2021
3 Feb 2021
16 Feb 2021
3 Feb 2021
12 Feb 2021
3 Feb 2021
45 days
Amount
Manning and Operation of Main Receiving cum Distribution Sub Station (DSS - 16), 33 KV HT supply including 2 x 625 KVA D.G. set of make: Cummins installed at site 'E', NAD Karwar for 03 (three) shifts of 8 hours each round the clock on all days including Sundays and holidays including minor daily maintenance/checks, attending breakdown at Distribution Sub Station No DSS 16 all as specified and as directed. The installation comprises of following equipments :-
(a) 33 KV,indoor type HT VCBs - 3 Nos
(b) Indoor type Power transformer 2 MVA, 33 KV / 433 V - 2 Nos.
(c) Main LT Panel board 415 V with ACBs & main switches, MCCBs etc with Bus couplers & power factor improvement capacitor bank.
(d) Battery bank for auxillary supply.
(e) D.G. Set 415V, 625KVA with connected accessories-2Nos
(f) D.G. Set control panel
(g) 110 Volts battery bank with charging panel.
NOTES for item No 1 :-
(a) Contractor has to employ minimum following staff for Manning and operation of the DSS - 16 in all 3 shifts of 8 hours each round the clock :-
(i) One skilled electrician / operator per shift of 08 hours (Total 03 shifts per day) having minimum ITI qualificaiton in Electrician trade from Govt recognised institute with adequate knowledge for HT & LT electrical installation / DG Set installation. The operator shall be competent to carryout the routine maintenance of Main distribution sub station all as directed
(ii) One helper per shift of 08 hours (Total 03 shifts per day) having minimum 10th class pass.
General Note applicale for item No 1
(a) The operator employed by the contractor shall be capable of carrying out minor repair maintenance & should have well experience in electrical pump set & DG set field
(b) Each shift duration shall be 8 hours & duty timing will be decided by Engr-in-Charge.
(c) The unit rate quoted shall be deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation.
(d) Checking / Rectification of leakage of water.
(e) Checking/Rectification of loose electrical/fule/water connections.
(f) Maintaining the general cleainliness and upkeep of the installation.
(g) In case of any abnormal noise/ complaint the plant should be put off and same should be brought to the notice of Engineer-in-Charge.
(h) The operator shall check oil level, fuel and inform Engineer-in-charge/JE regularly.
(j) The operator shall check the water / coolant level in radiator daily & top up as and when required.
(k) The operator check level of electrolyte and distilled water in battery & top as and when required, maintain the record of specific gravity.
(l) Check battery terminals, if found loose, tighten it properly. Battery terminals shall be cleaned regurlarly
(m) The quoted rate is deemed to be inclusive of cotton waste, cleaning material etc & operator will ensure general area cleanliness and upkeep of the installation on daily basis.
(n) The contractor shall pay the wages to the Skilled operators through e payment i.e Aadhar linked bank accounts(Credit to their bank account). Engr-in-Charge shall ensure that e-payment made to Skilled operators and their wages shall not be less than minimum wages fixed by state Govt or central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engineer-in-Charge and the same shall be kept in record duly verified.
(o) It is responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailing scales as laid down by the Ministry of labour for all Electrician/operator/helper (as applicable) and necessay proof to this regard shall be submitted to Engr-in-charge for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, he shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding.
POPULAR ENTERPRISES
PEGASOS ENGINEER TRADERS
Bidder Name
JAI SHREE GOPAL ELECTRICALS
PEGASOS ENGINEER TRADERS
POPULAR ENTERPRISES
stage.html
html • 0.02 MB
finance_467566.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .