Loading…
Loading…
Tender Value
₹3.0 L
EMD Value
₹6,000
Closing Date
18 Jul 2026, 3:00 pm
DY.C.E(S and D)
Office of The Dy.C.E(M)/(S and D) 5, S.N Banerjee Road, Kolkata-700013
Repairing of switching and protective accessories, installation of LED luminaries, etc. of sector-I and III quarters with allied electrical Works under PBPS(Drg)/S and D.
2026_KMC_1030725_1
KMC/DR/PBPS/E/08/2026-2027
Open Tender
MISC ELECTRICAL WORKS
14 days
6/1 Palmar bazaar road, Kolkata-700015
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹6,000
Office of The Ex. Engr.(M)/PBPS(Drg)/S and D.
8 Jul 2026
8 Jul 2026
20 Jul 2026
9 Jul 2026
18 Jul 2026
9 Jul 2026
9 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. (RATE IN RS. PER MTR), 3 CORE 6 SQ. MM
SHEDULE OF IRRIGATION & WATERWAYS DEPT. 2022 PAGE NO.101, SL. NO. 5.3 | - | METER | 125 | - |
| 2 | Laying through Floor/ Pavement/Wall.Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.iiAbove 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.Laying on Wall / surface with Saddles / clamps.(b)Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting | - | RUNNING METER | 60 | - |
| 3 | SUPPLY AND FIXING OF GREENLINE V2 STREET LIGHT(115 WATT) COMPLETE WITH ALL ACCESSORIES TO BE FIXED/PROJECTED FROM THE WALL OF THE BUILDING OR ON
POLE INCL. MAKING HOLES/PROVIDING CLAMPING ARRANGEMENT & NECY. GI REDUCER AS REQUIRED. S&F 40MM GI PIPE (ISI-MEDIUM) QUALITY 1.5 MTS. AVERAGE LENGTH HAVING SUITABLE BEND S&F NECY. LENGTH OF 1.5 SQMM PVC INSULATED SINGLE CORE STRANDED ANNEALED COPPER WIRE AND MAKING CONNECTIONS AS REQUIRED
AND MENDING GOOD DAMAGES TO WALL INCL. PAINTING ETC.
SHEDULE OF IRRIGATION & WATERWAYS DEPT. 2022 PAGE NO.112 ITEM NO. 5.3 F.11.0.1 MAKE : PHILIPS,115 WATT | - | EACH | 9,284 | - |
| 4 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 16. Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal
with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (a) 200 x 150 x 100mm | - | EACH | 498 | - |
| 5 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13
mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(b)By TATA(Medium GI pipe | - | SET | 1,524 | - |
| 6 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision FOR earthing
attachment .Legrand 2+12 way Enclosure (607712) | - | EACH | 1,757 | - |
| 7 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 63 A FP | - | EACH | 1,830 | - |
| 8 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP | - | EACH | 190 | - |
| 9 | Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp.1. Supplying & Erection of 40x40x6x300 mm long Galv. (HOT Dip) angle iron crossarm FOR carrying insulators incl. painting | - | EACH | 304 | - |
| 10 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 36/0.3 (2.5 sqmm) | - | RUNNING METER | 74 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
TENDERFORM.pdf
Tender Documents • 1.29 MB
BOQ_2530951.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid