RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Patient Bed (Fowler And Semi Fowler) ( 100 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Performance Parameters Type of bed Semifowler Semifowler Number of bed platform sections 2 for semi fowler bed 2 for semi fowler bed Availability of Backrest Yes * 1/10 section Backrest section linkage welded with MS CRCA tube (14 G) * Availability of Leg section NA for semifowler NA for semifowler Leg section linkage NA for semifowler NA for semifowler Mattress platform shall be perforated Yes * Screw mechanism welded with ERW MS tube (18 G) in M.S. cover made from (16 G) ERW tube * Manual adjustments Backrest through two screw systems with thrust bearings individually manouvred by handle for semifowler bed Backrest through two screw systems with thrust bearings individually manouvred by handle for semifowler bed Back rest - min 45 % of the frame length Yes * The bottom end of the H legs are provided with PVC shoes NA in case of bed with castors NA in case of bed with castors The bed has head & foot panels detachable by hand without need of any tool Yes * Saline rod provision four locations on the bed platform to hold stainless steel Telescopic Saline rod 12mm dia with 15.87 mm dia x 1.2 mm (18 G) stainless steel * Provision for mounting of syringe pump outer covering tube with a knob to mount syringe pump * Finishing & workmanship shall be of high standard Yes * All corners shall be rounded off so that there shall be no sharp corners and holes should be burr free Yes * Coating for metal parts M.S. tubular parts
Requiredlinkages
Requiredflats are to be In-house
Requiredpretreated shot blasted and Epoxy * 2/10 powder coated with coating thickness 50 to 100 microns Material of handle SS SS Number of detachable moulded PP with PVC insert head and foot side panels 4 * Provision of castors H' Type Legs with 600 mm Height with 125 mm(5") dia High Grade Synthetic Body Castors
Requiredtwo with brake
Requiredtwo w/o brake H' Type Legs with 600 mm Height with 125 mm(5") dia High Grade Synthetic Body Castors
Requiredtwo with brake
Requiredtwo w/o brake Number of hooks in Telescopic I V Pole 2 2 Urine Bag Holder Yes * Moulded Chart Holder Yes * Provision of mattress Yes * Number of sections in mattress 2 for semi fowler bed 2 for semi fowler bed Provision of collapsible Railing Yes Yes Material and Dimensional Parameters Overall Length of bed in mm with 5% tolerance 2050 to 2100 * Overall width of bed in mm with 5% tolerance 900 to 950 * Size of Buffer in mm 75 75 Bed Platform frame size with 5% tolerance 2070 mm L x 910 mm W * Mattress Platform size with 5% tolerance 1970 mm L x 790 mm W * Buffer to Handle Length with 5% tolerance 2275 mm * Fixed Height 600 mm * Material and size of section 1.2 mm (18 G) CRCA M.S perforated sheet top * Overall length of Back Rest 775-800 775-800 Overall width of back rest 750-775 * Overall length of Knee Rest NA for semifowler NA for semifowler Overall width of NA for semifowler NA for semifowler 3/10 Knee Rest Overall length of Leg Rest NA for semifowler * Overall width of Leg Rest NA for semifowler NA for semifowler Overall length of Fix Section 100-150 100-150 Overall width of fix section 750-775 750-775 Raised Backrest Angle 65⁰ * Raised Kneerest Angle NA for semifowler * Bed frame tube size 60 mm x 30 mm x 1.6 mm (16 G) Thick ERW tube * Dimensions for Fitting of frame ERW tubes diameter 31.75 mm x 1.2 mm (18 G) thick and diameter 22.22 mm x 1.2 mm (18 G) thick and MS sheet having thickness 3.0 mm (11 G) * Diameter of Four corner rubber buffers in mm 75 * Material of head and foot panels ABS Plastic * Diameter of MS tubular in mm 30 to 50 mm * Diameter of SS Laminated 30 to 50 mm * Patient Working Load 135 Kg * Safe Working Load 150 Kg * Thickness of PU foam of mattress in inch 4 * Density of PU foam of mattress in Kg/m3 40 * Material of mattress cover of mattress PVC * Colour of mattress cover Blue Blue Material of collapsing railing ABS ABS Types of collapsing railing Collapsable Collapsable Reports Manufacturer ISO 14001:2015 * 4/10 Certificates Details of manufacturer certificates such as number and date - * Availability of certificates of quality system ISO 13485 * Availability of test report from govt NABL/ILAC accredited lab covering all parameters Yes Yes Test report number
RequiredIncase test reports not availabble
Requiredput NA - * Test report date
RequiredIncase test reports not availabble
Requiredput NA - * Name of test lab
RequiredIncase test reports not availabble
Requiredput NA - * Address of test lab
RequiredIncase test reports not availabble
Requiredput NA - * Copies of all certifications and reports to be provided to buyer on demand at time of supplies Yes Yes * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.