ARC for maintenance of Substation equipments of Udaipur municipal Corporation. (e_03 / Light_02)
2024_DLB_413882_1
E_03_2024-25_Light_02
Open Tender
Electrical Works
Item Rate
365 days
udaipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Commissioner, Municipal Corporation Udaipur
₹15,000
5 Sept 2024
17 Aug 2024
27 Aug 2024
17 Aug 2024
25 Aug 2024
17 Aug 2024
Amount
Service inspection call charges for visiting the substation within 2 Hrs of call.This includes clearing any minor problem associated with substation equipments such as blown HT fuse,loose connections etc.
Repairing and Maintenance of Transformers of following rating including labour for oil filling, cleaning and other maintenance work as per direction of concerned engineer. 63 KVA
Providing and filling of transformer oil top up in the transformer where the oil value are within the permissible limit.
Providing and replacing of damaged L.T. Side bushing rod made of brass on the following rating transformer. 63 KVA
Providing and fixing of silica gel breather with coupling on the following rating transformer 63 KVA
Providing and replacement of damaged rubberized crok gasket bushing on the following rating transformer 63 KVA
Providing and replacing of damaged H.T. Side bushing rod made rod brass on the following rating transformer. 63 KVA
Repairing and Maintenance of following rating DG set at Nagar Nigam sub-station which Includes labour for oil filling and other maintenance work as per direction of concerned engineer. 30 KVA
Supply and Fixing of Diesel filter 30 kva DG set
Supply and Fixing of Diesel filter for 62.5/125 kva DG set
Supply and Fixing of Oil Filter 30 kva DG set
Supply and Fixing of Oil Filter for 62.5/125 kva DG set
Supply and Fixing of Coolant for 62.5/125/250 kva DG set
Supply and Fixing of Turbo oil for 62.5/125/250 kva DG set
Supply and fixing of 62.5 KVA DG set feed pump
Supply and fixing of 62.5 KVA DG set AVR
Supply and Fixing of Battery 12 volt 100 Ah for Diesel Generator
Supply and Fixing of Battery charger 24 volt 100 Ah for Diesel Generator
Supply and Fixing of Battery charger 12 volt 100 Ah for Diesel Generator
Supply and Fixing of Element LUB oil filter
Supply and Fixing of fuel filter item 3973232
Supply and Fixing of fuel filter item 3973233
Supply and Fixing of resistor corrosion 4058965
Supply and Fixing of Element air filter A041R273
Supply and Fixing of Element filter A041R279
Supply and Fixing of Inhibitor Corrosion 10 liters
Supply and Fixing of Valvoline premium blue 7800 Plus 1/20 ltr
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .11 KV End Termination Kit Outdoor type 3 core 120/150/185 Sq.mm
11 KV Straight Through Joint Kit 3 core 120/150/185 Sq.mm
LT Straight Through Joint Kit 3.5 core 50/70/95 Sq.mm
11 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4 pole Power contactors with following AC 1 Rating 100 Amp
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. Armoured Cable 70.0 Sq. mm 3.5 core
95.0 Sq. mm 3.5 core
185.0 Sq. mm 3.5 core
Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for qualit y assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 core 185.0 Sq.mm
3 core 120.0 Sq.mm
Supplying and making one end termination with heavy duty brasscompression gland (as per IS 12943- 1990) SIBG type, heavy dutyaluminium lugs (as per IS 8309 -1993 & IS 8337-1976 ) duly crimpedwith crimping tool, PVC tape as per PWD specification for electricalWorks etc for following size of Armoured PVC insulated & PVCsheathed/ XLPE aluminium conductor cable of 1100 volt grade asrequired of size. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3.5 x 25.0 sq.mm
3.5 x 35.0 sq.mm
3.5 x 50.0 sq.mm
3.5 x 70.0 sq.mm
3.5 x 185.0 sq.mm
Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With sheet steel enclosure made out from CRCA sheet door 1.2mm & body 1.6mm, powder quoted, door locking system allow opening of door in off position only with 2 external earthing point 63 A
Supplying and making end termination with heavy aluminium lugs Pin / ring type (as per IS 8309 -1993 & IS 8337-1976 ) duly crimpedwith crimping tool, PVC tape as per PWD specification for electricalWorks etc of following size. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 185.0 Sq.mm
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2 / IEC 60947- 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push (test) to trip , including making connections with lugs / spreaders etc. as required With Thermal Magnetic Release up to 100 Amp , 16/25 kA, adjustable O/L & fixed S/C setting
200 Amp, 25/35 kA, adjustable O/L & fixed S/C setting
250 Amp , 35/40kA, adjustable O/L & fixed S/C setting
S&F off load change over switch four pole/2 pole, 230/ 415 V ,conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in the following rating: Four pole 63 A
Service inspection call charges for visiting the cable testing and magering within 2 Hrs of call as per instruction from engineer in charge
Service inspection call charges for visiting the transformer testing and magering within 2 Hrs of call as per instruction from engineer in charge
P&F of 63 KVA DG Set Digital Procom AMF Controller Set DS6D
Penal Relay
Contractor 80 Amp 4 Pole
Indication Light
Wiring and cliping
Repairing Labour for DG Set
Providing & Laying P.V.C. / XLPE insulated & P.V.C. copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity >99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer 25.0 Sq. mm 1 core
35.0 Sq. mm 1 core
Providing and fixing of DG set fan belt 30 KVA to 125 KVA as per the directions recived from engineer in charge.
S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3/3.5/4 x 185.0 sq.mm-300 sq.mm
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .