| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | ₹4.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.9 L+₹65,120 (15.4%)Rejected-Finance 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | ₹4.9 L+₹65,120 (15.4%) | L2 | Rejected-Finance L2 |
Tender Value
₹4.5 L
EMD Value
₹9,014
Closing Date
6 Apr 2021, 5:00 pmClosed
EXECUTIVE ENGINEER ELECT DIV. PWD B AND R BR HISAR
EXECUTIVE ENGINEER ELECT DIV. PWD B AND R BR HISAR
CONSTRUCTION OF NEW BUILDING OF GOVT. INDUSTRIAL TRAINING INSTITUTE AT SUREWALA IN DISTT. HISAR (PDG. ADDITIONAL POINT OF POWER WIRING ONLY)
2021_HRY_165467_2
WD/Elect-GGN/Elect-HSR/100133
Open Tender
Electrical Works
Works
120 days
HISAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹9,014
23 Jun 2021
31 Mar 2021
7 Apr 2021
31 Mar 2021
6 Apr 2021
31 Mar 2021
Amount
a) Main Switches: Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. HSR 31.12 v) Double pole switch 32 amp. 415 Volts Cat-B,
xiv) Triple pole switch with neutral link 32 amp. 415 Volts.Cat-B
xv) Triple pole switch with neutral link 63 amp. 415 Volts Cat-B
c) Molded case Circuit breakers: Supply and erection of molded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. HSR 31.12 i) 15 amp. to 63amp. 415 V ,10 KA 3-phase.
ii) 100 amp.to 220 amp.415 V,10 KA 3-phase.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. HSR 31.13 ii) Size 40 mm x 40 mm x 6 mm.
M.S.Sheet . HSR 31.14: i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
L) Miniature Circuit Breaker and Isolator: Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. HSR 31.17 a) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
ii) TP MCB 6 amp. to 32 amp.
ix) TP MCB 40 amp. to 63 amp.
P) Pipe Laying: Supply and erection of PVC pipe of 6 kg. pressure laid 1 meter below ground level complete including digging refilling of the trench with jointing etc. HSR 31.21 c) PVC pipe 65 mm dia.
(Q) Earthing HSR 31.22: i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
iii) Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt ) complete as equired.
v) Extra for charcoal or coke and salt for GI. Plate or copper plate earth electrode.
xv) Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
xi) Pdg. and fixing 25 mm x 5 mm GI. strip in 40 mm dia GI. pipe from earth electrode as required .
xix) Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. staples of same size.
S) Under Ground Cables: Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. HSR 31.25 xxvii) 70 Sq. mm 3.5 Core Ard. Cable .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. HSR 31.26 xxviii) 70 Sq. mm 3.5 Core Ard. Cable.
xxxix) 10 Sq. mm 4 Core ard. Cable .
xI) 16 Sq. mm 4 Core Ard. Cable.
Supply and erection of suitable compression type brass cable glands for underground Cable. HSR 31.28 i) Upto 6 sqmm Cable 2 to 4 core.
ii) 10 Sqmm 2 to 4 Core .
iv) 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core .
Supply and erection of MS stand made of 50mmx50mmx6mm angle iron frame and 150cm long, 30cm wide with MS sheet covering size 30cmx30cm 3.15mm thick fixed on the top of board & legs duly embedded in 1:2:4 cement concrete block 30cm below ground level including cost of cement sand welding, painting & fabrication charges etc upto the entire satisfaction of Engineer-in-Charge of the work. HSR 31.51
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. HSR 31.69 vi) 4 Pole MCCB 200 amp
Non Schedule Item :Supply and erection of Double door sheet, steel loadline/ Powerline Vertical distribution boards are titled with bus bars, netrual link, and blanking plate (but without cost of MCCBs) suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 125 amp as incomer complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (Make: Havell's/ IndoAsian) 12 Way vertical TPN Distribution board
Dhamija Power Constructions
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .