Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹27.5 L+₹910 (0.03%)Rejected-Finance SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹27.9 L+₹39,450 (1.44%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹28.8 L+₹1.3 L (4.64%)Rejected-Finance MEHAN P O CHANDPUR CHANDPUR BILASPUR HIMACHAL PRADESH 174004 | BILASPUR | HIMACHAL PRADESH | 174004 | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹29.0 L+₹1.5 L (5.49%)Rejected-Finance 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
24 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE 865 EWS Pin 913865
REPAIR REPLACEMENT OF EXTERNAL WATER DISTRIBUTION NETWORK ALONGWITH CONNECTED ACCESSORIES AT TRANSIT CAMP UNDER AGE EMI OF GE 865 EWS
2025_MES_705594_1
865/EWS(NIT-58)/2025-26
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹86,000
Yes
7 Jul 2025
26 Apr 2025
26 May 2025
26 Apr 2025
24 May 2025
11 May 2025
Amount
Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and directed.
M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.(Surplus soil if any shall not be removed but left over the trench)
M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
S & F in replacement of 100 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S & F in replacement of 80 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S & F in replacement of 50 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S & F in replacement of 25 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S & F in replacement of gun metal globe or gate valve of 80mm complete, all as speceifed and as directed.
S & F in replacement of gun metal globe or gate valve of 50mm complete, all as speceifed and as directed.
S & F in replacement of gun metal globe or gate valve of 25mm complete, all as speceifed and as directed.
S & F in replacement of Non Return Sluice Valve of size 80 mm (2”) dia.
S & F in replacement of 40 mm bore MS pipe heavy grade with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S & F in replacement of 25 mm bore MS pipe heavy grade with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S & F in replacement of PP-R Pipe PN-20/SDR 11,3 layer 50 mm dia bore with all fittings conforming to IS -15801 and fixed complete to walls and ceiling or laid in floors or trenches all as specified and directed by Engr-in-Charge.
S & F in replacement of PP-R Pipe PN-20/SDR 11,3 layer 40 mm dia bore with all fittings conforming to IS -15801 and fixed complete to walls and ceiling or laid in floors or trenches all as specified and directed by Engr-in-Charge.
S & F in replacement of PP-R Pipe PN-20/SDR 11,3 layer 32 mm dia bore with all fittings conforming to IS -15801 and fixed complete to walls and ceiling or laid in floors or trenches all as specified and directed by Engr-in-Charge.
S & F in replacement of PP-R Pipe PN-20/SDR 11,3 layer 25 mm dia bore with all fittings conforming to IS -15801 and fixed complete to walls and ceiling or laid in floors or trenches all as specified and directed by Engr-in-Charge.
S & F in replacement of PP-R Pipe PN-20/SDR 11,3 layer 20 mm dia bore with all fittings conforming to IS -15801 and fixed complete to walls and ceiling or laid in floors or trenches all as specified and directed by Engr-in-Charge.
S & F in replacement gate valve conforming to ISO 9001- 2000 conforming ISO- 15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PP-R pipes or for union and fixed completely as spd for the size 50 mm dia bore.
S & F in replacement gun gate valve conforming to ISO 9001- 2000 conforming ISO- 15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PP-R pipes or for union and fixed completely as spd for the size 40 mm dia bore.
S & F in replacement gun gate valve conforming to ISO 9001- 2000 conforming ISO- 15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PP-R pipes or for union and fixed completely as spd for the size 32 mm dia bore.
S & F in replacement gun gate valve conforming to ISO 9001- 2000 conforming ISO- 15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PP-R pipes or for union and fixed completely as spd for the size 25 mm dia bore.
S & F in replacement gun gate valve conforming to ISO 9001- 2000 conforming ISO- 15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PP-R pipes or for union and fixed completely as spd for the size 20 mm dia bore.
Supply & laying in of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 50 Sqmm 3.5 Core including taking down old unserviceable cable, complete all as specified and directed.
Supply & laying in of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 35 Sqmm 3.5 Core including taking down old unserviceable cable, complete all as specified and directed.
Supply & laying in of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 10 Sqmm 3 Core including taking down old unserviceable cable, complete all as specified and directed.
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of 40 mm dia MS pipep complete all as specified and directed.
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of 25 mm dia MS pipep complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised strip 25 mm x 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel of size 600x600x6 mm, supplying and laying charcoal stone aggregate) chamber and mild steel angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade all as shown in drawing. Note : (a) GI earth Strip will be measured and paid separately beyond 7.5 Mtr length, the rates of funnel with GI pipe for watering is deemed to be included in this item.
Taking down old unserviceable PVC water tank and supply, installation, testing and commissioning PVC TANK, two layers black color, ISI marked (Cylindrical, vertical ) with closed top hoisted with threaded cap and fixed in position all as specified of capacity 10000 ltrs each including all accessories (i.e GI nipples etc) including provn of inlet 50/80mm dia inlet, outlet, overflow and washout pipes complete alongwith staging of stone masonary appropriate size as specified and directed,
Material and labour for construction of stone masnory valve pit size 120 x 120 x 150 cm (internal dimension) built in cement mortar 1:4 incl plastering 20mm thick internally and externally in CM 1:4 PCC 1:4:8 TYPE D-2 15 CM thick in foundation extending 10CM beyond external faces of wall around PCC flooring 1:1:4 type B-1 40 mm thick cover made out of 3.15mm thck MS round bar and locking arrangement with lock 2 keys. MS sheet cover should be painted with two coats of enmalled paint over a coat of ed oxide primer all as specified and directed by Engr-in-charge.
M&L for de-watering, cleaning of water reservoir/UG sump of 25000 Gallon capacity with high pressure jet complete all as specified and directed in six stages cleaining process as under :- (a) De watering the tank with portable sub mersible pump of suitable capacity (b) Cleaning of wall, ceiling and floor with high pressure rotary water jet and bleaching powder/liquid (c) Spraying of non toxic bio de-gradable echo friendly anti bacterial agent certified by Govt approved lab to disinfect the tank from harmful pathogens. The dose utilized should be as per OECD guide No.432. (d) Treatment of inside tank exposing UV radiation to kill the suspended or floating bacterial material remaining in the tank.
M & L for checking of line leakage at various places including labour for excavation,welding work,returning filling including required material (e.g. lead jointing,rubber gasket,flange etc.) for DI/CI/GI/PP-R 100-20 mm dia pipe complete all as specified and directed.
Deduct Schedule of Credit of Rs (-) 88565.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
PADMA ENTERPRISES (BID ID -3304512)
Amar Singh (BID ID -3304516)
TIRUPATI ENGINEERS CORPORATION (BID ID -3303904)
Sona Enterprises (BID ID -3295255)
M/s Ranpat Dev Infrastructure pvt ltd (BID ID -3304409)
M/S NANCY ENTERPRISES (BID ID -3299231)
M/S MUNEER HASSAN AKHON (BID ID -3304214)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .