Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest L1 | |
| 2 | L2₹30.7 L+₹2.1 L (7.18%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹31.5 L+₹2.8 L (9.85%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹34.4 L+₹5.8 L (20.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.4 L+₹5.8 L (20.3%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Apr 2022, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR/MAINT OF CENTRAL AND PACKAGE TYPE AC PLANTS, ACs WATER COOLER, REFRIGERATOR, DEEP FREEZER AND OTHER MISC COOLING APPLIANCES INCLUDING CONNECTED ITEMS AT AIR FORCE STATION PATHANKOT
2022_MES_513865_1
8420/GE/PAF-75/2021-22
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹90,000
1 Jun 2022
15 Mar 2022
14 Apr 2022
15 Mar 2022
12 Apr 2022
29 Mar 2022
Amount
Comprehensive/preventive maintenance of the following Window / Split ACs / Water cooler / Refrigerator /Deep Freezer of different capacities by carrying out periodically maintenance of equipments including cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injection required for cleaning condenser/cooling coils complete and attending complaints all as specified and as directed by Engr-In-Charge for following (a) 1.5/2.0 Ton capacity Split AC.
(b) 1.5/2.0 Ton capacity window type AC
( C) Water cooler of any capacity
(d) Refrigerator of any capacity
(e) Deep freezer of any capacity Note: for items No 1 to 1.03 (i) Window / Split ACs / Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis, (ii) Window/ Split Acs are to be maintained for heating as well as cooling mode all as specified and directed.A1 (iii) The contractor shall ensure and assesed at the site any initial maintenance required, to make the all Window/Split ACs/Water cooler / Refrigerator /Deep Freezer/Desert cooler in fully proper working condition. (iv) The date of periodical check will start from the date of commencement of work. (v) After completion of contract, contractor shall hand over the all " handed over Window / Split ACs / Water cooler / Refrigerator /Deep Freezer/Desert cooler" in perfect running/functioning condition to the department. (vi) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. (vii) Penalty for not rectifying the defect in time(within 24 hrs)will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (viii) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M. (ix) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made. (x) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule. (xi) Cost of minor spares i.e, insulation to copper tubes, soldering, internal wiring to cooling appliances are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately, Refrigerant gas will only be measured when major items i.e, Comperessor, Condensing coil, Cooling coils are replaced, else cost of refrigerant gas required for less cooling, due to leakage etc will be deemed to be included in quoted rates. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor. (xii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates.
Supply only following items 2.00 to 2.29 to be fixed under Item No. 1.00 (a) to 1.03 (e) above :- Running capacitor of capacity 1.5 to 2.5 MFD as per existing sample and requirement
Running capacitor of capacity 4 to 8 MFD as per existing sample and requirement
Running capacitor of capacity 10 MFD as per existing sample and requirement
Running capacitor of capacity 30 to 42 MFD as per existing sample and requirement.
Running capacitor of capacity 45 to 60 MFD as per existing sample and requirement.
Starting capacitor, 40/60 MFD to 80/100 MFD as per existing sample and requirement.
Starting capacitor, 100/120 MFD to 120/150 MFD as per existing sample and requirement.
Thermostat switch for cooling appliances as per existing sample
Overload relay for cooling appliances as per existing sample
Starting relay for cooling appliances as per existing sample
Capillary tube special annealed double wound copper tubing as per existing sample
Copper tubing for cooling appliances of required size as per existing sample
Condensor Fan blade for cooling appliances of any size as per existing sample
Blower Fan blade for cooling appliances of any size as per existing sample
Blower Motor for cooling applinaces of any size as per existing sample
Condensor Motor for cooling appliances of any size as per existing sample
PCB card for refrigerator as per existing sample
PCB card for Air conditioner including remote as per existing sample
Push cock stainless steel as per existing sample for water cooler
Float valve as per existing sample
Plastic drain pipe for water cooler as per existing sample
Plastic drain pipe for Air conditioner as per existing sample
Swing motor for Air conditioner as per existing sample
PVC connection as per existing sample
Display unit of Split/Window AC
Strainer/Filter for cooling appliances as per existing sample
Gasket, suitable for magnetic door of Refrigerator of any make and capacity and as per sample
Chilling tray, suitable for Refrigerator of any make and capacity as per existing sample
Vegetable tray, suitable for Refrigerator of any make and capacity as per existing sample
Freezer chamber for refrigerator of any make and capacity as per existing sample
M&L for replacement of condensing coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge.
All as per item No 3.00 above here in before but for Water cooler/refrigerator/deep freezer of any capacity complete all as specified and directed by Engr-in-Charge.
Material and labour for replacement of cooling coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge.
All as per item no 5.00 above but for refrigerator/ water cooler/ Deep freezer of any capacity as per sample complete all as specified and directed by Engr-In-Charge.
Taking out of desert cooler from the site, de-assembling, cleaning of distribution pipe for proper water spray on pads, oiling and greasing the fan motor and tullu pump, checking of electrical circuit, fixing broken parts with the help of nut bolts, welding if required etc complete all as specified and directed by Engr-In-Charge.
Material and labour for shifting of window/Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to Copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units if required including testing after shifting complete all as specifed and directed by Engr-In-Charge.
Supply and fixing in Replacement of electrical lead from main connection 3 core PVC insulated copper conductor of size 2.5 Sqmm in PVC conduit concealed/recessed as required at site complete all as specified and directed by Engr-In-Charge.
All as per item No 9.00 above but of size 4 sqmm complete all as specified and directed by Engr-In-Charge.
Supply and filling of Gas R-22 for charging to window/Split Air conditioner/Deep freezer and water cooler to maintain adequate gas pressure complete all as specified and directed by Engr-in-Charge.
All as per item No 11.00 above but for gas R-407/410 complete all as specified and directed by Engr-In-Charge
All as per item No 11.00 above but for gas R-134A complete all as specified and directed by Engr-In-Charge
Material and labour for replacement of blower motor for Desert cooler as per sample complete all as specified and directed by Engr-In-Charge.
Material and labour for replacement of blower fan blade suitable for Desert cooler as per sample complete all as specified and directed by Engr-In-Charge.
Material and labour for replacement of submersible tullu pump suitable for desert cooler complete all as specified and directed by Engr-In-Charge.
Dismantling and taking out old unserviceable indoor unit and S&F in replacement indoor type unit of split type air conditioner 1.5 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
Dismantling and taking out old unserviceable outdoor unit and S&F in replacement outdoor unit of split type air conditioner 1.5 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
Dismantling and taking out old unserviceable indoor unit and S&F in replacement indoor type unit of split type air conditioner 2.0 TR of existing make complete including blower, controller card, cooling coils remote control etc including testing and connection with outdoor unit complete all as specifed and directed by Engr-In-Charge.
Dismantling and taking out old unserviceable outdoor unit and S&F in replacement outdoor unit of split type air conditioner 2.0 TR of existing make including condensing coil, condensor motor and fan blade, hermetically sealed compressor suitable for Non CFC based Refrigerant gas, inlet outlet copper valves to connect with indoor unit and other accessories as required including testing and connection with indoor unit complete all as specifed and directed by Engr-In-Charge.
Material and labour for replacement of rusted desert cooler body of desert cooler capacity upto 4000 cum/hr with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size matching with existing fabricated out of 20 gauge mild steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water, electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min 3 mtr in length). External surface shall be spray painted over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as per sample and specified and directed by the Engr- in- Charge.
Material and labour for replacement of rusted louver suitable for desert cooler of capacity upto 4000 cum/hr as per sample complete all as specified and directed by Engr-In-Charge.
Material and labour for replacement of front grill including control panel prewired for desert cooler of capacity upto 4000 cum/hr as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of wood wool pads different sizes as required with fixing accessories of superior quality /high density for desert cooler complete and all as specified and directed by Engr-In-Charge
Supply and fixing in replacement front show grill of window AC 1.5 Ton capacity of any make as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engr-In-Charge.
Material and labour for providing locking arrangement in water cooler tank for provisioning of padlock including hinges, fixing clamp, welding/nut bolts/rivetting as required complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement water collector rack in water cooler for safe flow of unused water as per existing sample complete all as specified and directed by Engr-In-Charge.
Material and labour for repair to broken gates of deep freezer/water cooler/Refrigerators by providing proper hinges at ends and to ensure complete compactness of the equipment to arrest cooling inside complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement 13 mm thick nitrile rubber insulation to metallic portion of room i.e gates/windows etc duly pasted using proper glue complete all as specified and directed by Engr-In-Charge.
Material and labour for removing the old unserviceable hermatically sealed compressor unit from Water cooler of 40/80 ltrs capacity and supply & fixing new sealed unit reciprocating type hermatically sealed compressor unit as per sample including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.
Material and labour for removing the old unserviceable hermatically sealed compressor unit from Water cooler of 160/120 ltrs capacity and supply & fixing new sealed unit reciprocating type hermatically sealed compressor unit as per sample including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.
All as per item No 32.00 above but for 1.5 TR split/window type AC complete all as specified and directed by Engr-In-Charge
All as per item No 32.00 above but for 2.0 TR split type AC complete all as specified and directed by Engr-In-Charge
All as per item No 32.00 above but for upto 185 ltrs refrigerator complete all as specified and directed by Engr-In-Charge
All as per item No 32.00 above but for refrigerator above 185 ltrs but upto 320 ltrs refrigerator complete all as specified and directed by Engr-In-Charge
All as per item No 32.00 above but for Deep freezer of capacity above 185 ltrs upto 320 Ltrs complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Plug Top 5 Amps, 230 volts AC complete all as specified and directed by Engr-In-Charge.
All as per item No 38.00 above but for 15 Amps complete all as specified and directed by Engr-In-Charge.
Supply & fixing in replacement of potential correction unit, with digital display and designed for input variation between 180 V to 250 V with output voltage stabilized at 230 V within tolerance limit and suitable for AC of capacity 2.0 Ton not less than 5 KVA complete all as specified and directed by Engr-In-Charge.
Material and labour for taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including reassembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed.
Supply and fixing in replacement MCB SP,upto 32 Amps, 10kA, 240 Volts complete all as specified and directed by Engr- In-Charge.
Supply and fixing in replacement MCB SP,upto 40 Amps, 10kA, 240 Volts complete all as specified and directed by Engr- In-Charge.
Supply and fixing Gate valve of size 15 mm dia with ISI marked complete all as specified and directed by Engr-In-Charge.
Supply and fixing Gate valve of size 20 mm dia with ISI marked complete all as specified and directed by Engr-In-Charge.
Material and labour for servicing of AC plant any type and any capacity up to 39TR including, cleaning/descaling of cooling coil, insulation of suction and discharge line, oiling, greasing of blower motor, checking of electrical circuit supply and and replacement of defective filter, relay, capacitor over load protector etc as required, rewiring and cleaning of condensor coils with Acid/Scale removal compound for removal of scales deposited in condenser coils using suitable size iron rods/brush/water circulating pump etc.complete all as specified and directed by Engr-in-charge. Note: Acid/Scale removal compound and required T&P should be provided by contractor without any extra cost. Note: Items to be replaced needs to be checked only for serviceability and will be measured and paid seperately under respective item of schedule
Material and labour for Servicing, testing and cleaning of hot water gererator including replacement of minor item and checking of heating strip .complete all as specified and directed by Engr-in-charge.
Supply and fixing Filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement strip heaters 3.0 kilowatt suitable for mounting in AC Plant ducts or as required complete all as specified and directed
M&L for taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including reassembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed.
Material and labour for replacement of PVC honey comb fins suitable for cooling Tower of any capacity upto 3x39 TR complete as per sample all as specified and directed by Engr-in-Charge
Material and labour for replacement of water distribution flaps of cooling tower of AC Plant of any capacity upto 3x39 TR as per sample complete all as specified and directed by Engr-In-Charge.
Material and labour in replacement of air filter of AHU as per sample made of suiable filter with efficiency not less then 90% class 1 to 10 micron, matching with existing sample complete all as specified and directed by Engr-in-Charge.
Material and labour for cleaning of Cooling tower of any capacity by draining out water from inside, and including descaling of base tank and sprinkler including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
Material and labour for cleaning of base tank of Air cooling plant having blower motor of 15 HP capacity by draining out water from inside and including descaling of tank and water sprinklers including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
Supply and changing/top up of compressor oil N-68 to AC Plant compressor upto adequate level complete all as specified and directed by Engr-in-Charge.
Repair/servicing of air handling unit, cleaning of all duct from A.H.U.to supply air grill and cleaning/descaling of cooling coil, water pressure meter, greasing to bearings and taking out the dust and mud complete all as specified and directed by Engr-In-Charge
Material and labour in replacement for duct insulation with 25 mm thick fiber glasss and covered with polythene sheet & chicken wire mesh or with 9 mm thick nitrile sheet to duct where ever exposed to unconditioned space complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement for MS pipe insulation with nitrile rubber insulation and then cladded with Aluminum foil or plastered using sand cement plaster over chicken wire mesh matching with existing packing complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement water spray nozzles 32mm dia of Air cooling plant as per sample complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement air grills/diffusers fabricated out of powder coated extruded aluminum sections including bird screen/VCD etc as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of by pass safety valve for AC plant of capacity upto 39 TR as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement water pressure gauge assembly complete with connection pipe to the existing pipe line complete with matching with existing sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement temperature gauge assembly able to display temperature in degree celsius and fahrenhiet complete including connection to the existing pipe line matching with existing sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement HP/LP cutout complete all as specified and directed by Engr-In-Charge.
Supply and fixing of thermostatic expansion valve suitable for central AC plant of capacity 5.5 to 39 TR, complete and all as specified and directed by Engr-in-Charge.
Material and labour for Replacement pilot control solenoid coil suitable for AC plant matching with existing sample complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement oil failure switch matching with existing sample complete and all as specified and directed by Engr-in-Charge.
Supply and fix in replacement MCCB 63 Amps, 3/4 Pole, complete all as specified and directed by Engr-In-Charge.
All as per item No 70.00 above here in before but of capacity 100 Amps complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement MCB TPN, 63 Amps 415 volts complete all as specifeid and directed by Engr-In-Charge.
Supply and fixing in replacement of Power contactor suitable for hot water generator 80 Amps rating three pole, 415 volts complete all as specfied and directed by Engr-In-Charge.
All as per item No 32.00 above but for 18 Amps complete all as specified and directed.
All as per item No 32.00 above but for 40 Amps complete all as specified and directed.
Supply and fixing in replacement V belt of any size matching with existing sample complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement Controller circuit board for AC chiller of capacity 39 TR as per sample complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement Controller circuit board for Package type AC plant of capacity upto 16.5 TR as per existing sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of LCD display cum operating unit for package type AC plant of capacity upto 16.5 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed.
Supply and fixing in replacement of LCD display cum operating unit for hot water generator suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed.
Supply and fixing in replacement hermatically sealed reciprocating type compressor unit of capacity 5.5 TR of make and model as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement thermal overload relay suitable for upto 7.5 HP three phase induction motor as per existing sample complete all as specified and directed by Engr-In-Charge.
Material and labour for replacement of MS pipes 80 mm dia including all accessories or welding at site complete all as specified and directed by Engr-In-Charge
Material and labour for replacement of GI pipes 15 mm dia including all accessories or welding at site complete all as specified and directed by Engr-In-Charge
Supply and fixing Gate valve of size 25mm dia with ISI marked complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement gate valve suitable for 80mm dia MS Pipe complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of single phase preventer complete in all aspects matching with existing sample complete all as specified and directed by Engr-in-Charge.
Supply and charging of gas R407 to Package type/Central AC Plants to maintain adequate gas pressure and seal the leakage of the unit if found leakage before charging the gas complete all as specified and directed by Engr-in-Charge.
All as per item No 88.00 above but gas R22 complete all as specified and directed by Engr-In-Charge
JYOTI ENTERPRISES
KALSI CONSTRUCTION CO
PAWAN KUMAR GOVT. CONTRACTORS
R K BUILDERS
VIRAT CONSTRUCTIONS
M/S BR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .