| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC | ₹4.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹4.1 Cr+₹6.1 L (1.50%)Rejected-Finance | ₹4.1 Cr+₹6.1 L (1.50%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹4.1 Cr+₹9.4 L (2.31%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹4.1 Cr+₹9.4 L (2.31%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹4.2 Cr+₹16.6 L (4.10%)Rejected-Finance | ₹4.2 Cr+₹16.6 L (4.10%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹4.3 Cr+₹21.4 L (5.30%)Rejected-Finance | ₹4.3 Cr+₹21.4 L (5.30%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹4.7 Cr
EMD Value
₹5.4 L
Closing Date
16 Nov 2024, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
PROVISION OF INFRASTRUCTURE FOR GROUND SYSTEM AND PARKING HEAVY VEHICLE WIH ANNEXURE FOR AKASH-NG PROJECT AT DRDL UNDER GE I RND KANCHANBAGH HYDERABAD
2024_MES_675722_1
84012
Open Tender
Civil Works
Lump-sum
450 days
Kanchanbagh Hyderabad
Class A
Category a (i)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I RND KANCHANBAGH HYDERABAD
₹5.4 L
Yes
18 Dec 2024
20 Sept 2024
23 Nov 2024
20 Sept 2024
16 Nov 2024
2 Nov 2024
Amount
SCHEDULE 'A' PART-I (BUILDINGS & STRUCTURES) Construction of Heavy Vehicle Parking with Annexure double storey with RCC M-30 grade (Design mix) framed structure,connecting passage, VDF flooring, PU WPT etc complete all as specified and as shown on drawings.
Lump sum price worked out by the Contractor for “EARTH WORK EXCAVATION & SITE CLEARANCE" as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of `1,22,522.90 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `68,331.00 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹8,97,804.00 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `6,060.30 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for "EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VI representing _______ % ________________ percent Above / Below the lump sum price of `2,06,298.00 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “REFRIGERATION & AC” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `60,088.00 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT” as listed in Schedule ‘A’ Part - VIII representing _________ % __________________ percent Above / Below the lump sum price of `23,31,068.80 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of ₹6,81,090.50 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of ₹1,83,880.08 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “HIGH BAY LIGHTING, LAN & TELEPHONE AND LIGHTENING PROTECTION” as listed in Schedule ‘A’ Part - XI representing _______ % _______________ percent Above / Below the lump sum price of `3,42,796.00 inserted by the MES in Schedule ‘A’ Part - XII
Schedule 'A' Part-XII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 12.00 to 55.00.
EARTH WORK EXCAVATION & SITE CLEARANCE Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes or for removal/laying of cables etc not exceeding 10 sqm on plan and not exceeding 1.5 metre in depth and getting out in hard/dense soil includig trimming of foundations and forming bottom surface to required level complete all as specified and directed
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
INTERNAL WATER SUPPLY S&F two way bib cokc, cast copper alloy, chromium plated for size 15mm dia with crutch or butter handle, screwed down for iron pipe complete all as specified and directed.
S&F health faucet cast copper alloy, chromium plated including 1 metre pipe and all lfittings to fix screwed down for iron pipe complete all as specified and directed.
INTERNAL ELECTRIFICATION Point wiring with 1.5 sqmm copper conductor FRLS (Multistranded) PVC insulated ISI marked unsheathed cable of any length drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia ISI makred with all fitting and other accessories and also including PVC insulated ISI makred unsheathed FRLS cable size 1.5 sqmm copper conductor as earth wire to common earth dolly including galvanised terminal boxes ISI marked fxing into the wall of size as required at site and modular plates and frame suitable for fixing switches/sockets/fan regulators etc and making good the disturbed surfaces matching to the existing surface for one light point/fan/exhaust point/bell point controlled by one way modular switch 5 Amps 240 volts complete all as specified and directed.
One 3 pin 5Amps switch socket outlet point in independent board.
One 3 pin socket outlet 5 Amps on the same board with other switches.
For one light point controlled by two way switch 6 Amps 240 volts.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size.
M&L in door bell AC 230 volts single phase multi music type complete all as specified and directed.
S&F 1 x 20W, 230V, 6500K, CCT surface mounted integral LED batten with extruded aluminium housing with inbuilt electronic driver, polycarbonate diffuser including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to filling complete all as specified and directed.
S&F 1 x 10W, 230V, 6500K, CCT surface mounted integral LED batten with extruded aluminium housing with inbuilt electronic driver, polycarbonate diffuser including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to filling complete all as specified and directed.
Supply and fix security light LED 35W IP-66 protection, color temp (cool white) pressure die cost aluminium body with high power LEDs at light source and transparent diffuser, inbuilt electronic driver and luminous efficacy of 120lm/watt fixing on the GI bracket of not less than 25mm dia bend to shape as required at site and fixing with necessary GI clamps on the all including connecting up with three core copper cable complete all as specified and directed.
S&F for fixing the heavy duty exhaust fan of sweep 300mm, single phase, 240V, 900 RPM including aluminium louvers and necessary fastner fixing accessories to fix on any type of wall complete all as specified and directed. Note:- All necessary civil work like making hole inside the wall for installation of exhaust fan also included in quoted rate.
S&F for fixing the heavy duty exhaust fan of sweep 450mm, single phase, 240V, 900 RPM including aluminium louvers and necessary fastner fixing accessories to fix on any type of wall complete all as specified and directed. Note:- All necessary civil work like making hole inside the wall for installation of exhaust fan also included in quoted rate.
Supply and fixing of MCCB 160 Amps, TPN, 415V, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 36KA adjustable overload 3 min 80-100% complete all as specified and directed.
Supply and fixing 415V, 10 KA 'C' curve miniature circuit breaker (MCB) triple pole and current carrying capacity 63 Amp in the DB complete with connection, testing and commissioning complete all as specified and directed.
M&L for earth continuity conductor of main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to poles or any other indicated location for loop earthing etc as required of size 4mm GI wire complete all as specified and directed.
M&L for earth continuity conductor of main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to poles or any other indicated location for loop earthing etc as required of size 20 x 3mm copper strip complete including the porcealin/PVC insulators necessary for fixing the strip complete all as specified and directed.
Supply and laying GI pipe light grade of 20mm dia including on any type surface/wall/ground with necessary fixing spares complete all as specified and directed.
Supply & fix bell push flush type 5 Amps 230 volts switch complete all as specified and directed.
Supply & Fix recess mounted LED luminaire 36W 2' x 2', 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Grid ceiling or similar mounting system with concealed or exposed 'T' sections, glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete all as specified and directed.
S&F industrial interlocked switched sockets surface/wall mounting socket 63 Amp 3P+N+E4 pole with straight plug 63 Amp 3P+N+E, IP 66 protection and sockets enclosure DX3 cabinet IP 66 protection 5 module fixed on wall/surface with including incoming MCB TPN 63 Amp, 4P, FP complete all as specified and directed.
S&F industrial interlocked switched sockets surface/wall mounting socket 32 Amp 3P+N+E4 pole with straight plug 32 Amp 3P+N+E, IP 66 protection and sockets enclosure DX3 cabinet IP 66 protection 5 module fixed on wall/surface with including incoming MCB TPN 32 Amp, 4P, FP complete all as specified and directed.
Removing excavated material to a distance not excedding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
EXTERNAL WATER SUPPLY Material and labour for steel tubing, medium grade, ISI marked, galvanised including short lengths, laid in trenches complete with all fittings (such as bends, elbows, tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) 25mm bore of pipe complete all as specified and directed. Note:- Excavation and earth work required for above item shall be measured and paid separately.
EXTERNAL ELECTRIFICATION Supply and laying synthetic rubber insulated mats 2mm thick for voltage upto 3.3 KV for electrical purpose asper IS-15652-2006 (superseding IS-5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand filling shall only be measured and paid.
Supply and laying un-reinforced precast concrete cable cover, class LV, Type-I, flat size 250mm x 150mm x 40mm complete all as specified and directed.
S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty), ISI marked, IS:7098 Part-I with aluminium conductor ], LT 1100 volts grade of cross sectional area 3.5 core 120 sqmm, laid in trenches/on poles/walls including provision of suitable hardware accessories connecting up, testing on completion and commissioning complete all as specified and directed. Note:- Excavation and earth work required for above item shall be measured and paid separately.
All as per item No 38 above but of size 35 sqmm 3.5 core complete all as specified and directed.
Supply, installing, testing & commission of LT panel outdoor type, cubicle type asper IEC-61439-1 & 2 for 415 v, 50 Hz, rated fault current : 50 KA for 0.5 sec with internal arc containment dust, varmin proof, weather proof, IP-54 grade of protection, providing aluminium bus bar of capacity 400 Amps rating including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable alongwith ferouls. The panel shall be painted with anti corrosive coating and finely powder coated of flint gray shade (RAL-7032), the panel should be provided with multifunction meters, volt meter, 3 phase indicators lamps and the panel should be mounted on 'C' channel base of required size duly coated with anit corrosive paint the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (where necessary) complete all as specified and directed with following :-
Material and labour for cutting existing road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type C1 using 20mm grade aggregate complete all as specified and directed.
M&L for modification the existing LT panel board at sub station with 2.0mm thick CRCA sheet factory made in door type totally enclosed weather dust and vermin proof as per IS, CPRI approved with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 400 Amps with necessary supporting insulators so as to match with existing LT panel board/distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel/bus bar including necessary supporting frame/channel fix through existing cable trench form ground with MCCB 250 Amp, 36 KA, Ics=100% with spreader- 01 Nos complete all as specified and directed. Note; Provision for incoming and outgoing cable of size as per the site requirement from the extended portion LT distribution panel.
Material and labour for removal and re-laying of LT/HT UG cables laid in site in trenches including excavation, refilling sand cushioning for rerouting complete all as specified and directed.
REFRIGERATION & AC Supply, installation, testing and commissioning of storage type water cooler, stainless steel, electric driven single phase 230 volts having approximately 80 litres storage capacity and nominal cooling capacity 40 litres per hour complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed.
Supply, install, testing and commissioning inverter type Hi-wall split type air conditioner of capacity 2.0 TR, 5 star rated complete with indoor and outdoor units complete with all accessories, twin rotary compressor, copper condenser, wide air flow blade, auto clean, auto restart, operating model, cool, dry, fan, suitable for working on 240 volts, single phase, AC, 50 Hz with cordless remote control unit, anti bacterial dust filter, refrigerant copper piping, control cable, water drain pipe of adequate length and size including initial filling of suitable refrigerant gas upto required quantity and AC should be latest current year model of manufacturers and including providing voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type, external wall mounting and designed for input variation between 170V to 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% and making all connections complete all as specified and directed.
Note :- (i) 5 star rating and EER rating of manufacturer model should be of latest current year. (ii) Pipings with best insulation of required size drain out PVC pipe and control cable of suitable rating upto 3 metre be included in the quoted rate beyond 3 metre shall be measured and paid separately. (iii) The quoted rate is inclusive for taking out existing wooden panelling/ceiling etc as existing on site making good in all respects to match with the adjacent surfaces complete all as specified and directed.
SEWAGE DISPOSAL Providing DWCPE (SN8) 200(OD)/175(ID)mm dia metre pipes, laying and jointing with stiff mixture adhesive of cement mortar in the proportion of 1:1 (1 cement : 1 find sand) including testing of joint etc complete all as specified and directed.
M&L for Conventional LLDPE septic tank for 30 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Venft shaft, connection etc comlete all as specified and directed
M&L for Soakage wells of size 2.40 m dia and 4.50 m effective depth with excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and directed
HIGH BAY LIGHTING, LAN & TELEPHONE AND LIGHTENING PROTECTION Supply and fix aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
Providing and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8 mm dia hex head screw complete all as specified and directed.
Material and labour single pointed air termination, single pointed aluminium rod 12mm dia and 300mm long including nuts, bolts, clamps etc complete all as specified and directed.
S&F LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of luminious efficacy 150lm/wat 120W, 240V, 5000K CCT, aluminium heat sink alogwith inbuilt electronic driver, wide beam angle including hanging the fitting with required hook arrangement required at site complete all as specified and directed.
Supply and fixing RJ 45 jack with gang box and outer plate for LAN connection complete all as specified and directed.
Supply and fixing RJ 11 jack with gang box and outer plate for Telephone connection complete all as specified and directed.
HTE INFRA LLP (BID ID -3161292)
M/S GDR CONSTRUCTIONS (BID ID -3161141)
R. Wadhumal and Sons (BID ID -3156342)
CHARAN ELECTRICALS (BID ID -3160074)
R K GOEL ABHEY KUMAR JAIN (BID ID -3165524)
INDGUARD ENGINEERS (BID ID -3161498)
Sai construction & services (BID ID -3167119)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.rar
Tender Documents • 23.13 MB
Tenderdocument.pdf
Tender Documents • 1.90 MB
Tenderdocument_2.pdf
Tender Documents • 0.29 MB
BOQ.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .