BARMER
MILITARY ENGINEER SERVICES GARRISON ENGINEER ARMY JALIPA MIL STN POST BOX NO 53 BARMER 344001
REPAIR/MAINTENANCE OF DG SETS AMF PANELS, SOLAR WATER HEATERS AND ITS CONNECTED ITEMS AT JALIPA MIL STATION UNDER GE ARMY BARMER
2022_MES_506776_2
GE (A)/BMR-57 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹10,000
31 Aug 2022
17 Mar 2022
7 Apr 2022
17 Mar 2022
6 Apr 2022
24 Mar 2022
Amount
M&L for maintanence and servicing of 250 KVA Diesel genarator sets installed at 81 Armd Pump house Make : cummins including connected Alternator and carryng out routine 'A' check of the engine and servicing works as listed below for smooth functioning all as per manufactures instructions and as directed. (a) To check (every 50hrs/1 month wichever is earlier) (1) Lubrication greasing to all parts (ii) Check all engine level (b) Fuel system : Drain sediment from fuel tanks. (c) Air System: every 50hrs/1 month wichever is earlier (i) Clean pre Cleaner dustpan weekly (ii) Check Air cleaner restriction clean/change cleaner element if required. (d) Cooling system: Check coolent level OTHER MAINTENANCE: (i) Drainer tank (ii) Check and correct leaks (iii) Drain fuel filter.Water separator. (iv) Check belts & adjust if required Note: Engine oil/Radiator coolent oil top up will be measured and paid separately.
All as per item No.1 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House
All as per item No.1 here in before but 82.5 KVA installed at 13 Grd Pump house
All as per item No.1 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre,22 grd and jalipa Pump House
All as per item No-1 but 20 KVA at 22 Grd Pump house
All as per item No-1 but 30 KVA installed at Bde Pump House
M&L for carring out following periodical maintanence on 250 KVA Diesel genaratorsets installeed at 81Armd Pump House (a) To check (every 250 Hrs/Every 6 month) (i) Repeat 'A' Lubrication (ii) Changing Engine Oil (iii) Record oil pressure. (b) Fuel system : (i) Check Hydrulic Governor oil. (ii) Check throttle linkage.(iii) Lubricant Ball joints of the throttle linkage of Hydrulic Governor. (iv) Change of Fuel filter. (v) Clean fuel tank breather.. (c) Air System: (i) Clean / Change cranckcase Breather. (ii) Check Air Pipings/durettes (d) COOLING SYSTEM: (i) Check coolant in radiator.(ii) Add coolant concentrate if required(maintaining pH value in between 7.5 to10.5) (iii) Check heat exchanger zinc (sacrificial Anode) plugs. Note: (i) Coolant oil, Engine oil utilised will be measured and paid separatly. (ii) The rate quoted must be inclusive of the necessary oil filter, fuel filter , air filter units and the gaskets, O rings and clips required for changing of the filter elements
All as per item No.07 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House
All as per item No.07 here in before but 82.5 KVA installed at 13 Grd Pump house
All as per item No.07 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre, 22 Grd and jalipa Pump House
All as per item No-07 but 20 KVA at 22 Grd Pump House.
All as per item No-07 but 30 KVA installed at Bde Pump House
M&L for Removing the unserviceable display unit from the control panel and supply and fix in repair display unit (LCD) in the control panel of 100 KVA DG set including connecting with the necessary wiring with soldering and testing after fixing complete all as specified and as directed.
M&L for servicing of Self Starter assy by disconnecting from engine and dismantling the same cleaning all accessories , replace the wornout parts like :- brushes, bushes , contact plates, jumping leads and seals, revarnishing the field coil , armature and reassembling the same , refitting the engine and testing of 250 KVA DG set complete all as directed
All as per item No.14 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House
All as per item No.14 here in before but 82.5 KVA installed at 13 Grd Pump house
All as per item No.14 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre, 22 Grd and jalipa Pump House
All as per item No-14 but 20 KVA at 22 Grd Pump House.
All as per item No-14 but 30 KVA installed at Bde Pump House
M&L for Removing the U/S battery and supply and fix moulded PVC body low maintanence lead acid battery 12 volts 180 AH Make: Exide.
M&L for Removing the U/S battery and supply and fix moulded PVC body low maintanence lead acid battery 12 volts 130 AH Make: Exide.
Supply and filling/top up engine oil SAE 15 W - 40 [CH grade) [Make : VOLVOLINE ]
Supply and filling/top up Radiator coolant [Make : VOLVOLINE ]
M&L for Removing the unserviceable battery charger and supply and fix in repair external battery charger 12 V DC at DG set room at Jalipa main pump house including necessary connections and testing complete all as directed .
M&L for Overhauling of radiator assy of DG set 250 KVA by disconnecting and removing from eingine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion ..etc by means of acid cleanig and high pressure water washing , air cleaning , re assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hoses ,clips as reqd
All as per item No.25 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House
All as per item No.25 here in before but 82.5 KVA installed at 13 Grd Pump house
All as per item No.25 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre
All as per item No-25 but 20 KVA at 22 Grd Pump House.
All as per item No-25 but 30 KVA installed at Bde Pump House
Supply only fan belts as per exisiting make for 250 KVA capacities of DG Sets.
All as per item No-31 here in before but 100 KVA .
All as per item No-31 here in before but 82.5/62.5 KVA .
All as per item No-31 here in before but 20/30 KVA .
Supply only Solenoid switch, 24 Volts, Suitable for 100 KVA DG SET
Supply only Engine control Unit [ IN-NT-PLUS] 24 Volts, Suitable for 100 KVA DG SET
M & L for sevicing and calibration of governor unit in-si-tu including replacement of worn out parts if any and testing it for a maximum droop of 20% complete all as specified and as directed for 250 KVA DG set
All as per item No-37 here in before but 100 KVA .
All as per item No-37 here in before but 82.5/62.5 KVA .
All as per item No-37 here in before but 20/30 KVA .
Supply and fix Tacho drive meter including cable assembly 1.5 mtr length [0.200]RPM [Make : KOEL/VDO]
Supply and replace Brass, Battery terminals
M&L for Repair and servicing of 250 KVA PT pump assembly and injectors by replacing the unserviceable parts like centre shaft, loading spring, relief valve-2 Nos bearings.governor barrels & plunger-1Set O-ring kits,gasket kit,injector plunger & barrel -6Nos,ball check -6Nos and calibration and phasing of injectors and FIP in test bench and reassembling etc as required.
All as per item No-43 here in before but 100 KVA .
All as per item No-43 here in before but 62.5 KVA .
All as per item No-43 here in before but 30/20 KVA .
M&L for Taking down Geyser of any capacity/type from existing position for repair /cleaning/ descaling of inner tank with descaling solution/wire brush, sand paper and refixing the same after repair complete all as specified and as directed. (Spares will be measured and paid separately under relevant items)
M&L for Taking out the unserviceable heating element and supply and fix in repair heating element 2000 W round Type complete all as specified and as directed.
M&L for Taking out the unserviceable heating element and supply and fixing in repair heating element 2000 W triangular type complete all as specified and as directed.
M&L for Taking out the unserviceable thermostat and supply and fixing in repair thermostat for 25/50 Ltr cap geyser and making connection complete all as specified and as directed.
M&L for Taking out the unserviceable red/green indicator lamps and supply and fixing in repair indicator lamp any type/size 230 Volt complete all as specified and as directed.
M&L for Taking out the unserviceable safety valve and supply and fixing safety valve ISI maked for any type geyser complete all as specified and as directed.
M&L for Taking out the unserviceable non return valve and supply and fixing inrepair non return valve vertical type chrome plated ISI marked in suction line of geyser complete all as specified and as directed.
M&L for Taking out the old toggle bolts and supply & fix in repair ground toggle bolts (tower/anchor), 4" long along with washers and nuts for fixing geysers 25/50 ltrs capacity.
M&L for Taking out the unserviceable PVC connection pipes and supply & fix in repair PVC metal braided connection pipes for hot water supply with brass adopters 450mm long.
M&L for Taking out the unserviceable PVC connection pipes and supply & fix in repair PVC metal braided connection pipes for hot water supply with brass adopters 600mm long.
M&L for Taking out the unserviceable plug tops and supply & fix in repair plug top 3 pin 15A ISI marked
M&L for Taking out the unserviceable connecting cable and supply & fix in repair copper cable flexible 3 core PVC insulated of size 50/0.25 (2.5 Sq mm)
Comprehensive maintenance and repairs of Solar Water Heating System consisting of Solar Water Heater Tank with Stand, Flat Plate Collector (Copper based), Electircal Coil (for backup), Non Return Valve at Inlet and Outlet, Pressure Release Valve etc complete of 10 Nos of 200 LPD capacities with electric back up (Cost of any minor spares shall be borne by the contractor):-
National Rewinding Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .