RequiredOEM Authorization Certificate Bid to RA enabled Yes Analog Transceiver-Handheld ( 725 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) PERFORMANCE FEATURES Frequency Range (MHz) 136-174 136-174 Types of Bandwidth VHF Full Band VHF Full Band Channel Capacity 128 128 Channel Spacing 12.5 * Frequency Spread without degradation in Tx/Rx Specification 5 * Frequency Stability (± ) 2.5 * 1/7 Antenna Impedance 50 * TRANSMITTER RF Power output setting of transmitter Programmable * RF Power output Range 1 to 5 Watts (VHF) 1 to 5 Watts (VHF) Type of Emission 11K0F3 * Frequency deviation ± 2.5Khz max. for 100% at 1KHz * Modulation Sensitivity 1 to 10mV at 1 KHz at mic. Input for +/- 1.5 KHz standard deviation * Modulation Distortion 5 * Modulation Fidelity +1
Required-3 dB of 6dB octave pre-emphasis charactrestics from 350 Hz to 2700 Hz with 1KHz as reference * Spurious & Harmonics Suppression (dB) 60 * VSWR 1.5 * RECEIVERS Sensitivity at 12 dB SINAD 0.25 * Squelch Sensitivity of receiver 0.25 * Adjacent Channel Selectivity (dB) 70 * Image Rejection (dB) 65 * Audio Output
Required(with less than 5 % distortion at 1 KHz reference measured at specified AF output) 500 * Audio Response +1
Required-3 dB of 6dB octave de- emphasis charactrestics from 350 Hz to 2700 Hz with 1KHz as reference * ACCESSORIES Antenna Helical Antenna * Programming kit No * Technical repairing & maintenance manual with complete block diagram
Requiredcircuit layout etc in soft as well as hard copy No * Battery charger Yes * 2/7 Output voltage of the charger - * Battery charger suitable for Lithium-ion * Charging time for standard mode 6 to 14hrs * Charging time for rapid mode 1 tO 3 hrs * Number of spare batteries with each Radio Set 1 1 POWER SOURCE/BATTERY Chemistry of Battery Li-ion * Voltage rating of the Battery 7.4 * capacity of Battery (milli AH) 2550 * VARIOUS FEATURES Simple Press to talk yes * Protection against high VSWR yes * Low Battery Alert yes * CTCSS or DCS yes * Capable of VOX for hands-free operation Yes * PTT ID Encode Yes * Busy Channel Lockout Yes * Channel Scanning with call quieting facility Yes * Selective Call Decode Yes * Capable of being Killed Unkilled Yes * Emergency SOS/SIREN Yes * LCD Display (Min 4 characters) Yes * Automatic Number Identification (ANI) Yes * Talk-around Yes * DTMF Keypad Yes * DTMF Microphone No * Keypad Lock Yes * Built-in GPS No * Battery Strength Bar Indicator or Digital Voltage read out Yes * 3/7 Signaling 2Tone
Required5Tone
RequiredDTMF * GENERIC Internal Speaker impedance 8 * External Speaker impedance 4 * Output Termination BNC female socket * Weight of Transceiver with Battery 380 * Other features - * SAFETY Protections Reverse polarity protection & short circuit protection * SERVICE Warranty 1 1.0 OPERATING CONDITION Minimum Operating temperature -10 * Maximum Operating temperature 55 * Minimum Storage temperature -40 * Maximum Storage temperature 70 * Humidity non- condensing (at +40 oC ) 95 * CERTIFICATION BIS registration under CRS of Meity for the battery - * BIS registration Number and Date for the Battery - * TEST REPORT DETAILS conformity to Dry Heat for 16 hrs at a maximum temp in accordance with IS:9 000/part-3/section-5 1977 latest Yes Yes conformity to Cold Test for 4 hrs at a minimum temp in accordance with IS:9 000/part-2/section-4 1977 latest Yes Yes conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH in accordance with I Yes Yes 4/7 S:9000/part-5/sectio n-1/1991 latest Drop Test (in packed condition): IS 9000 Part VII/SEC
Required3/1979 (reaffirmed 2004): Six drops one on each face
RequiredHeight of fall 1000 mm incase of handheld items and 500 mm in case of other items Yes Yes Vibration Test: IS 9000 Part VIII/1981 (reaffirmed 2006): 12 hours
Required4 hours along with each axis
Requiredat 15-150 Hz and with amplitude of 0-15 mm/2g Yes Yes Storage Test: IS 9000 Part III/SEC 5/1977 & Part II/SEC 4/1977 (reaffirmed 2004): -40 deg C for 5 hours
Requiredthen raise the temperature to 70 deg C for 16 hours Yes Yes Bump Test: IS 9000 Part VII/SEC 2/1979 (reaffirmed 2004): 4000 bumps at peak acceleration of 400 m/s sq Yes Yes Availability of the test report from Central Govt/NABL ILAC accredited lab to prove conformity to the specification No No If yes test report to furnished
Requiredto the buyer on demand No * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. 5/7 Additional Specification Documents