Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC | ₹6.4 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹7.1 Cr+₹70.2 L (11.0%)Rejected-AOC NOT SPECIFIED | ₹7.1 Cr+₹70.2 L (11.0%) | L2 | Rejected-AOC Not Being Lowest |
| 3 | L3₹7.8 Cr+₹1.5 Cr (22.9%)Rejected-AOC D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | ₹7.8 Cr+₹1.5 Cr (22.9%) | L3 | Rejected-AOC Not Being Lowest |
| 4 | Rejected-Technical BRICHGUNJ JUNGLIGHAT PO SRI VIJAYA PURAM 744103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | - | - | Rejected-Technical Not Enlisted in Eligible Category b (ii) |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
29 Nov 2021, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer (Navy) Visakhapatnam Station Road Visakhapatnam-530 004
PROVISION OF INFRASTRUCTURE FOR TECHNICAL ESTABLISHMENT AT INS RAJALI ARAKKONAM
2021_MES_479072_1
88739
Open Tender
Civil Works
Lump-sum
730 days
INS Rajali Arakkonam
Please refer Tender documents.
12 documents required · 12 mandatory
₹3,000
GE M NAS Arakkonam
₹6.8 L
Yes
1 Jan 2022
1 Oct 2021
1 Dec 2021
1 Oct 2021
29 Nov 2021
17 Nov 2021
Amount
PHASE-I:
SCHEDULE 'A' PART-I Note: Schedule 'A' Part-I. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Construction of Sub Station-1 Building in RCC framed structure complete all as specified and shown on drawings and as directed.
Construction of Sub Station-2 Building in RCC framed structure complete all as specified and shown on drawings and as directed.
Notes for SCHEDULE 'A' PART-I: (i) Earth work, excavation, returning filling in, disposal of surplus soil to a distance as specified, filling under floors with reference to NGL as shown in the drawings for building portion is deemed to be included in the scope of lump sum quoted against these items. (ii) The cost of RCC duct as shown in the drawings is deemed to be included in quoted lumpsum.
SCHEDULE 'A' PART-II to SCHEDULE 'A' PART-XIII INCLUDING PART-II A & II B: Note: Schedule 'A' Part-II to Part-XIII (Including Part-II A & II B) are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for 'Upgradation & Additions/Alterations Civil Works', as listed in Schedule 'A' Part-II A
Lump Sum price worked out by the contractor for 'Upgradation & Additions/Alterations E/M Works', as listed in Schedule 'A' Part-II B
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-III
Lump Sum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-IV
Lump Sum price worked out by the contractor for 'Internal Electrification', as listed in Schedule 'A' Part-V
Lump Sum price worked out by the contractor for 'External Water Supply', as listed in Schedule 'A' Part-VI
Lumpsum price worked out by the contractor for 'External Electrification', as listed in Schedule 'A' Part-VII
Lump Sum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-VIII
Lump Sum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-IX
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-X
Lump Sum price worked out by the contractor for 'Fencing and Gate', as listed in Schedule 'A' Part-XI
Lump Sum price worked out by the contractor for 'Rain Water Harvesting', as listed in Schedule 'A' Part-XII
Lump Sum price worked out by the contractor for 'Demolition and Dismantling', as listed in Schedule 'A' Part-XIII
SCHEDULE 'A' PART-XIV: (MISCELLANEOUS ITEMS): (Upgradation & Additions/Alterations Civil & E/M Works, Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Sewage Disposal, Road/Path/Culvert, Air Conditioning, Lightening Protection and Demolition and Dismantling):
UPGRADATION & ADDITIONS/ALTERATIONS CIVIL WORKS:
M&L preparation of new plastered surfaces and applying two coats of weather proof paint over one coat of weather proof primer complete all as specified and as directed.
M&L water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top: (i) Screed bed or bedding layer of 10mm thick in CM 1:3 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (ii) After setting & drying of screed bed, the entire surface of roof slab shall be cleaned thoroughly to remove all loose particles, dust/dust particles and applied with hot blown grade bitumen 85/25, @ 1.20 Kg/Sq.m. over bituminous primer @ 0.5 Ltr./Sq.m. (iii) Over hot blown grade bitumen 85/25, polymeric water proofing membrane 3 Kg/Sq.m. shall be laid over entire roof surface and on vertical surface up to grooves as applicable with overlaps of 100mm. The overlaps shall be sealed by flames or as per manufacturer instructions. Water proofing membrane shall be tucked in wall to a depth of 25mm (minimum) where applicable. Groove made in wall shall be filled with bitumen mastic filling and hot blown bitumen applied below membrane should be compatible with membrane all as per recommendation of manufacturers. (iv) A coat of hot blown bitumen 85/25 grade @ 1.2 Kg/Sq.m. shall be applied over water proofing membrane and final a coat of aluminium primer @ 0.10 Kg/Sqm. Notes: 1. WPC shall be measured and paid for separately. 2. Proper care shall be taken to provide similar treatment near junction of roof and parapet to avoid any leakage through junction.
UPGRADATION & ADDITIONS/ALTERATIONS E/M WORKS:
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor single core multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly complete all as specified and directed for One light point controlled by one switch or One fan (Ceiling fan/Exhaust fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps on independent board.
All as per item No.18 here-in-before but One 3 Pin socket outlet 5 Amps on the same board complete all as specified and directed.
All as per item No.18 here-in-before but One 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity complete all as specified and directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 32 mm dia. with accessories complete with four runs of 6 Sq.mm. cable and two runs of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. Note: Four runs of cable, two runs of earth wire and one run of conduit will be measured as one unit.
S&F moulded case circute breaker (MCCB) adjustable, thermal and fixed magnetic setting four pole, 125 Amps rating, ICS 100% ICU, breaking capacity 36 KA including MCCB enclosure, cable glands, lugs and termination box of suitable rating/size complete all as specified and as directed.
S&F high efficiency wall mounted LED batten 18 Watts [minimum 100 lumens per watts] with integrated electronic driver, long with slim and sleek locks with all accessories internally prewired complete all as specified and as directed.
S&F exhaust fan 380mm sweep, 1400 RPM metallic body (Heavy duty), complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
S&F air circulator fan 450mm sweep,1440 RPM speed, single phase, 230 Volts suitable for wall mounting including necessary hardware complete all as specified and as directed.
S&F rectangular GI perforated cable tray made out of GI sheet not less than 2mm thick of size 300 mm wide and depth not less than 50 mm including necessary hardware complete all as specified and as directed.
INTERNAL WATER SUPPLY:
S&F angle stop valve 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed.
S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed.
S&F bib taps 15mm dia., long body, cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed.
INTERNAL ELECTRIFICATION:
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor single core multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly complete all as specified and directed for One light point controlled by one switch or One fan (Ceiling fan/Exhaust fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps on independent board.
All as per item No.30 here-in-before but One 3 Pin socket outlet 5 Amps on the same board complete all as specified and directed.
All as per item No.30 here-in-before but One 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity complete all as specified and directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 2.5 Sq.mm. cable and one run of 2.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. Note for Item Nos.33 & 34: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
S&F energy efficient LED tube light fitting with tube 9/10 Watts [minimum 100 lumens per watts], 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and directed.
S&F energy efficient LED tube light fitting with tube 20 Watts [minimum 100 lumens per watts] , 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and directed.
S&F LED security light fitting with tube 30 Watt [minimum 100 lumens per watts] new generation energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq.mm. copper conductor cable up to connector including 1.5m long GI tubing light grade of 32mm dia. bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed.
S&F ceiling fans AC single phase 240 Volts of size 1200mm sweep with minimum delivery 210 cfm with service value, 6.00 BEE five star rated brushless direct current motor [BLDC] complete set with fixtures, metallic body complete all as specified and as directed.
S&F exhaust fan 250mm sweep 1350 RPM plastic body, complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
S&F exhaust fan 300mm sweep 1400 RPM metallic body (Heavy duty), complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip 25x4mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40 mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed. Note: Rate quoted deemed to be include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
EXTERNAL WATER SUPPLY:
M&L brick masonry valve chamber of size 750mmx750mx750mm (Internal size) by providing PCC 1:4:8 type D2 foundation 100mm thick, brick work in CM 1:4, plastering 15mm thick in CM 1:4 internal surfaces completely and external surfaces up to 150mm below GL, 75mm thick PCC 1:2:4 type B1 as in coping, valve chamber cover made up of 40x40x5mm size angle iron frame and 3mm thick MS sheet cover complete with locking arrangements and handle including painting steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
EXTERNAL ELECTRIFICATION:
Supply, fixing, installation, testing and commissioning of 11 KV VCB line up 05 (Five) panels indoor type switch board consisting of 400 Amps, VCB 11 KV-02 Nos. as incomer with bus coupler cum bus riser VCB 400 Amps 11 KV -01 No. with 400 Amps VCB 11 KV-02 Nos. as outgoing. indoor metal clad air insulated switchgear suitable for SCADA compatible rating 11 KV 3 Phase 50 cycles 400 Amps, 250 MVA 26.3 KA for 3 sec type with copper bus bars/jumpers with floor mounted, horizontal draw out type vacuum circuit breaker with motor and manual operated spring charge stored energy mechanism complete all as specified and as directed in and including with the following components: Make: ABB, Siemens, Schneider, Crompton Greaves Two Nos. of Incoming panels shall include the below items: (a) Current Tranformers 26.3 KA /1 Sec, Epoxy cast resin type single phase CTs dual ratio i.e 100-50 /1-1 A or as per site requirement as specified and directed by Deptt, CORE 1, CL 1.0, 15 VA, Core 2-CL 5P10, 15 VA-03 Nos. (b) Single phase 11 KV cast resin potential transformer (Draw out type) 11 KV/Route 3/110V/Route 3- core 1; 50 VA CL 1.0-03 No., MCB with add on contact for PT Secondary-02 Nos. (c) Breaker discrepancy switch (TNC)-01 No., Emergency push button-01 No., L/R Switch-01 No., LED Indication lamps -01 Set, 8 window alarm annunciator with RS 485 PORT-01 No., Bell/Hooter-01 No., MCB for Panel AC-01 No., MCB for Panel DC-01 No., MCB for spring charging motor-01 No., Anticondensation space heater/thermostat-01 No., 3 pin socket + switch-01 No., Test/service limit switch for VCB-01 No., Surge Arrestrer-03 Nos. Power pack-01 No.
(d) Microprocessor controlled numeric relay with RS-485 port comprising of three over current, one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply-1 No. (e) Master Trip Relay. (f) Trip Circuit Supervision relay-2 Nos. (g) Digital Multifunction meter with RS-485 port with class 1.0 Two Nos. of outgoing panels shall include the below items: (a) Current tranformers 26.3 KA/1 sec, Epoxy cast resin type single phase CTs dual ratio i.e 100-50 /1- 1 A or as per site requirement as specified and directed by Dept., CORE 1, CL 1.0, 15 VA, Core 2-CL 5P10,15 VA-03 Nos. (b) MCB with add on contact for PT Secondary-02 Nos. (c) Breaker discrepancy switch (TNC)-01 No., Emergency push button-01 No., L/R Switch-01 No., LED Indication lamps-01 Set, 8 window alarm annunciator with RS 485 PORT-01 No., Bell/Hooter-01 No., MCB for Panel A-01 No., MCB for Panel DC-01 No., MCB for spring charging motor-01 No., Anticondensation space heater/thermostat-01 No., 3 pin socket + switch-01 No., Test/Service limit switch for VCB-01 No., Surge Arrestrer-03 Nos. Power pack-01 No. (d) Microprocessor controlled numeric relay with RS-485 port comprising of three over current, one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply-1 No. (e) Master Trip Relay. (f) Trip Circuit Supervision relay
(g) Auxiliary relay for transformer faults to be provided in panel for transformer outgoing (h) Digital multifunction meter with RS-485 port with Class 1.0 Note: The panels shall be made of CRCA power coated steel sheet of 2mm thickness, dust and vermin proof, locking arrangement, totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, back entry type complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections with the following protective and control devices as specified below. The switchgear panels shall be of the fully arc proof (As per IS/IEC-62271-200), up to 26.3 KA for 1 Sec (Type test reports shall be submitted). Vacuum interrupters of the circuit breakers shall not be openly exposed design and shall be completely encapsulated in epoxy housing . The manufacturer of circuit breaker shall also be the manufacturer of the VI used in the breaker. The circuit breaker shall be suitable for E2, M2 duty. The circuit breaker should have valid type tests to support the afore-mentioned duty class. Tripping and/or release coils shall be continuous rated to ensure longer life. Integral spring charging handle to be provided in the VCB.
Supply, fixing, installation, testing and commissioning of standalone ICOG panel outdoor metal clad air insulated switchgear suitable for SCADA compatible rating 11 KV 3 Phase 50 cycles 400 Amps, up to 250 MVA, 26.3 KA for 3 sec type with Copper bus bars/jumpers with horizontal draw out type vacuum circuit breaker with motor and manual operated spring charge stored energy mechanism complete and including with the following components: Makes: ABB, Siemens, Schneider, Crompton Greaves (a) Current transformers 26.3 KA/1 sec, epoxy cast resin type single phase CTs dual ratio i.e. 100-50/1-1 Amp ,Core 1, CL 1.0, 15 VA, Core 2-CL 5P10,15 VA-03 Nos. (b) Single phase 11 KV Cast resin potential transformer (Draw out type) 11 KV/Route 3/110 V/Route 3-core 1; 50 VA CL 1.0-03 Nos., MCB with add on contact for PT Secondary-02 Nos. (c) Breaker discrepancy switch (TNC)-01 No., emergency push button-01 No., L/R Switch-01 No., LED Indication lamps-01 Set, 8 window alarm enunciator with RS 485 PORT-01 No., Bell/Hooter-01 No., MCB for Panel AC-01 No., MCB for Panel DC- 01 No., MCB for spring charging motor-01 No., Anti-condensation space heater/thermostat-01 No., 3 pin socket + switch-01 No., Test/Service limit switch for VCB-01 No., Surge Arrestrer-03 Nos. Power pack-01 No. (d) Microprocessor controlled numeric relay with RS-485 port comprising of three over current, one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxiliary supply-1 No. (e) Master Trip Relay
(f) Trip Circuit Supervision relay-2 Nos. (g) Digital multifunction meter with RS-485 port with Class 1.0 Note: ICOG Panel shall be made of CRCA powder coated steel sheet of minimum 3 mm thickness, dust and vermin proof, locking arrangement, totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, back entry type complete VCB panel confirming to IEC 62271-200 standards and IP of protection comprising necessary bus bars extension and connections with the following protective and control devices as specified below, vacuum interrupters of the circuit breakers shall not be openly exposed design and shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the VI used in the breaker. The circuit breaker shall be suitable for E2, M2 duty. The circuit breaker should have valid type tests to support the afore-mentioned duty class. Tripping and/or release coils shall be continuous rated to ensure longer life. Integral spring charging handle to be provided in the VCB. The ICOG in and including necessary PCC platform of appropriate size for installation of VCB.
Fabricate, supply, install, testing and commissioning of self supporting totally enclosed floor mounted on Base channel of size 75mmx75mm and thickness not less than 5mm Indoor type LT Panel fabricated from CPRI certified Panel builder factory fabricated made out of CRCA sheet not less than 2 mm thick, dust and vermin proof, with hinged smoothly openable front and rear door, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip 32x6mm for connecting provision-02 Nos., including ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, necessary tapping using aluminium strip from bus bar for MCCBs etc. complete panel board suitable for 3 phase 4 wire, 415 Volts 50 Hz, including comprising of the following items and connecting all outgoing feeder cables using suitable size lugs of any type complete all as specified and as directed: (i) ACB rating 1000 Amps, 415 Volts, 4P, 50 KA (ICU=ICS=ICW=100%) (1 sec) Manual draw out type ACB with microprocessor based trip unit with over load, short circuit, instantaneous earth fault protection, with CTs complete-01 No. (ii) Aluminium bus bar of 1500 Amp rating supported in suitable size porcelain strand/insulator lock with suitable size brass nut, bolt and washers with heat shrinkable colour coded PVC sleaving for three phase and neutral-01 Set. (iii) MCCB 500 Amps 3P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA (ICU=ICS=ICW=100%)-01 Nos. (iv) MCCB 350 Amps 3P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA (ICU=ICS=ICW=100%) (Outgoing feeders)-01 No.
Design, manufacturing, supply, installation, testing and commissioning of 150 KVAR, automatic/manual APFC panel 12 stage 440 Volts 50 Hz, with metal clad APFC, indoor type made out of 2mm thick CRCA sheet steel with dust and vermin proof hinged front opening double door shutters with neoprene rubber gasket powder coated including danger plate earth bar with GI strip 32x6mm-02 Nos. ventilation louvers bottom detachable gland plate complete including 75x75x6mm angle iron base frame and legs including locking arrangements and complete panels board manufactured by CPRI certified factory/firm and including the following with TPN aluminium bus bars complete with bus bar connection internal wiring ,incomer circuit breaker (Including MCCB) shall be mounted in a separate, louvers etc. requiring manual operations. The operational height of panel shall be at height not less than 300mm and shall not exceed 1850mm from the floor level with following complete all as specified and as directed: (i) Individual control panel MCB up to 30 KVAR 440 Volts 50 HZ-12 Nos. (ii) Heavy duty cylindrical type capacitor (5x4+10x4+20x3+30x1) fixed-150 KVAR 3 phase (iii) APFC relay with auto and manual mode-01 No. (iv) On/Off indication lamps (v) Cooling fan with filter SP-230 Volts-01 No. (vi) Multifunctional meter-01 No.
Design, manufacturing, supply, installation, testing and commissioning of 50 KVAR, automatic/manual APFC panel, 8 stage 440 Volts 50 Hz APFC shall be metal clad, indoor type made out of 2mm thick CRCA sheet steel with dust and vermin proof hinged front opening double door shutters with neoprene rubber gasket powder coated including danger plate earth bar with GI strip 32x6 mm-02 Nos. ventilation louvers bottom detachable gland plate complete including 50x50x6mm angle iron base frame and legs including locking arrangements and complete panels board manufactured by CPRI certified factory/firm and including the following with TPN aluminium bus bars complete with bus bar connection internal wiring, incomer circuit breaker (Including MCCB) shall be mounted in a separate, louvers etc. requiring manual operations. The operational height of panel shall be at height not less than 300mm and shall not exceed 1850mm from the floor level with following complete all as specified and as directed: (i) Individual control panel MCB up to 7.5 KVAR 440 Volts 50 Hz-08 Nos. (ii) Heavy duty cylindrical type capacitor (5x4 Nos,+7.5x4 Nos.) fixed-50 KVAR 3 Phase (iii) APFC relay with auto and manual mode-01 No. (iv) On/Off indication lamps (v) Cooling fan with filter SP-230 Volts-01 No. (vi) Multifunctional meter-01 No.
Fabricate, supply, install, testing and commissioning of self supporting totally enclosed floor mounted on Base channel of size 75mmx75mm and thickness not less than 5mm Indoor type LT Panel fabricated from CPRI certified Panel builder factory fabricated made out of CRCA sheet not less than 2mm thick, dust and vermin proof, with hinged smoothly openable front and rear door, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip 32x6mm for connecting provision-02 Nos., including ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, necessary tapping using aluminium strip from bus bar for MCCBs etc. complete panel board suitable for 3 phase 4 wire, 415 Volts 50 Hz including comprising of the following items and connecting all outgoing feeder cables using suitable size lugs of any type complete all as specified and as directed: (i) MCCB 400 Amps 3P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA (ICU=ICS=ICW=100%)-01 No. (Incoming) (ii) MCCB 350 Amps 3P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA (ICU=ICS=ICW=100%)-01 No. (Outgoing feeder) (iii) Panel mounting on load changeover switch 400 Amps, 4 Pole, 415 Volts, 50 Hz-01 No.
Supply, install, testing and commissioning of step down transformer dry type, HT 11 KV 3 Phase, LT 433 Volts, 3 Phase 4 wire, copper wound, air cooled indoor type of capacity 630 KVA with on load tap changers and with standard fittings/fixtures complete including temp gauge, HT/LT side cable box to be fitted with suitable size of cable gland complete as per IS all as specified and as directed.
Supply, install, testing and commissioning of step down transformer dry type, HT 11 KV 3 Phase, LT 433 Volts, 3 Phase 4 wire, copper wound, air cooled indoor type of capacity 200 KVA with on load tap changers and with standard fittings/fixtures complete including temp gauge, HT/LT side cable box to be fitted with suitable size of cable gland complete as per IS all as specified and as directed.
Supply, installation, testing and commissioning of servo controlled oil cooled voltage stabilizer for automatic operation three phase naturally oil cooled indoor type designed for input variation between 300 to 480 Volts with output voltage stabilized at 415 Volts with accuracy + 2.5% and speed of correction 8 Volt per second and of capacity 630 KVA including first fill of oil with desired dielectric strength filled up to appropriate level complete all as specified and as directed.
Supply, installation, testing and commissioning of servo controlled oil cooled voltage stabilizer for automatic operation three phase naturally oil cooled indoor type designed for input variation between 300 to 480 Volts with output voltage stabilized at 415 Volts with accuracy + 2.5% and speed of correction 8 Volt per second and of capacity 200 KVA including first fill of oil with desired dielectric strength filled up to appropriate level complete all as specified and as directed.
Supply, installation, testing and commissioning of isolation transformer three phase indoor type designed for 415 V/415 V fixed ratio copper wound of capacity 200 KVA complete all as specified and as directed.
Supply, installation, testing and commissioning of isolation transformer three phase indoor type designed for 415 V/415 V fixed ratio copper wound of capacity 630 KVA complete all as specified and as directed.
Supply, installation, testing and commissioning of UPS 2 KVA, 24 Volts indoor type, single phase AC input 160 V to 260 V and output 230 V + 1% including maintenance free batteries not less than 150 Ah-02 Nos. complete all as specified and as directed.
S&F HT adopter box made out of CRCA sheet steel, powder coated outdoor type 3mm thick with fixing arrangement, consisting of extension of existing HT bus bars with suitable size of copper bus bar with all jointing materials, insulators etc. for taping from existing RMU/HT VCB panel to the proposed out door type VCB panel complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, earthed 11000 Volts grade, of size 3 core 120 Sq.mm. complete all as specified and as directed. Notes: [a] The unit rate is deemed to include the cost of cable route indicator as per PS clause No.25.11. [b] Cables shall be tested at manufacturer's permises in the presence of representative of Accepting officer before dispatch.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) earthed 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed:
3½ core 300 Sq.mm.
3½ core 185 Sq.mm.
3½ core 150 Sq.mm.
3½ core 70 Sq.mm.
4 core 10 Sq.mm.
Taking up existing old under ground cable of the following sizes from the existing positions/trenches etc., and relaying in old/ new trench all as directed. Notes: (i) Excavation/earth work shall be measured and paid seprately under relavent schedule. (ii) Retrived serviceable bricks from site shall be properly stacked and reused as protection to UG cable and shall be measured and paid separetely under relevent item.
3½ core 120-185 Sq.mm.
3½ core up to 70 Sq.mm.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sq.mm. complete all as specified and as directed.
S&F cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 120-185 Sq.mm. complete all as specified and as directed.
S&F cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 25-70 Sq.mm. complete all as specified and as directed.
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40 mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed.
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia. by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed. Note for Item Nos.64 & 65: Rate quoted deemed to be include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
S&F earth continuity conductor GI strip 32mmx6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles complete all as specified and as directed.
Relaying common burnt clay bricks of sub class 'B', standard size for cable protection in trenches complete all as specified and as directed.
Boring of holes under road, pavement, hard standing etc. by trenchess technology using ultra sounding technique and necessary machine including HDPE pipe 160mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed.
M&L for Riddle earth cushioning over and around the cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall only be measured for payment.
M&L for Reinforced Pre-cast concrete cable covers, Class HV, Type-I, flat of size 300x180x40 mm complete all as specified and as directed.
SEWAGE DISPOSAL:
M&L Hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent haft, connection etc. for 10 Users. complete all as specified and as directed.
M&L soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2mx3.0m effective depth complete all as specified and as directed.
M&L for 150 mm dia DWC HDPE pipe single socketed in any length with rubber ring joints laid in trenches or under floors complete all as specified and as directed.
ROAD/PATH/CULVERT:
Preparation of WMM surface by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M&L 150mm thick (Compacted thickness) wet mix macadam (WMM) laid in two layers of 75mm thick each compacted separately with mechanical paver rolled consolidated to required gradient and camber as specified complete all as specified and as as directed by the Engineer-in-Charge.
M&L applying 2.5mm thick retro reflective painting of specified shade/ colour etc., either continuous or broken lines, to the required width and length over the existing painted surface/new bituminous surface with solvent based road marking paint (Retro reflective paint) of brand Road King or equivalent brand approved by MORTH, IRC and AAI including supply of paint material at the rate of 5 Kg per Sq.m. and glass beads at the of 0.35 Kg per Sq.m. (Reflective Index 1.5) using semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass bead dispenser, propane tank heater and profile shoe heater driven by experienced operator on road including all materials, labour, T&P and cleaning the road surface of dirt, seals, oil, gease and foreign materials etc., complete all as specified and as directed. Note: Retro reflective paint shall be applied as per manufacturers instructions along with MORTH technology and speciality.
S&F reflective cats eye with ABS material, body of size 100mmx100mm, with honeycomb patterned base, twin moulded shanks and two way retroreflective lenses, fixed with suitable adhesives on roads complete all as specified and as directed. Make: Series 290 OF 3M or equivalent approved by GE
AIR CONDITIONING:
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
Supply and fix air cooled split unit air conditioner electric driven single phase of capacity of 2 TR with copper condenser coil, green gas, mounting stand with all accessories as per BEE 5 Star inverter complete all as specified and as directed. Make: Carrier/Bluestar /Voltas Note: Extra length of copper tubing,as per site requirement is deemed to be included in the rate quoted.
Supply and install 5 KVA wall mounted voltage stabilizer for automatic operation single phase nautrally air cooled indoor type and designed for input variation between 130 Volt to 280 Volt with output voltage stabilised at 230 Volt with accuracy +2.5% including provision of volt meter for monitoring input and output voltage and bypass cut out switch complete all as specified and directed. Make: V-Guard/Purevolt/Voltas/Krykard
Supply and fix plug and socket SPN enclosure with a two pin and earth complete with one MCB SP 32 Amps 'C' curve 10 KA breaking capacity of 240 Volts complete all as specified and directed.
LIGHTNING PROTECTION:
S&F single pointed air termination aluminium rod, 12mm dia., 300mm long complete all as specified and as directed.
S&F aluminium strip 25x3.15mm complete with saddles porcelain cleats of suitable size and fixing screws for fixing the strip complete all as specified and as directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws complete all as specified and as directed.
S&F for GI earth strip of size 32x6mm with saddles and fixing screws etc. for roof/wall complete all as specified and as directed.
Supply and lay pipe galvanised iron tubing light grade 40mm dia. with all fittings and fixed to wall/pole/under road/culvert/drain or laid in floors complete all as specified and as directed.
S&F epoxy insulator of suitable size for fixing of aluminium strip on wall/roof/pole etc. complete all as specified and as directed.
DEMOLITION & DISMANTLING:
Taking down existing split type air conditioners (Indoor and outdoor units complete) including copper tubes and stabilizers from DME/DVOR, localizer and glide path buildings safely, shifting and hand over to MES stores all as specified and as directed.
Disconnecting the existing DG sets DME/DVOR-12.5 KVA capacity complete from its all electrical connections (Including AMF panel connection) and removing the complete DG set from its foundations, shifting the DG set safely and hand over to MES stores yard all as specified and as directed.
Disconnecting the existing DG sets Localizer-10 KVA capacity complete from its all electrical connections (Including AMF panel connection) and removing the complete DG set from its foundations, shifting the DG set safely and hand over to MES stores yard all as specified and as directed.
Disconnecting the existing DG sets Glide Path-15 KVA capacity complete from its all electrical connections (Including AMF panel connection) and removing the complete DG set from its foundations, shifting the DG set safely and hand over to MES stores yard all as specified and as directed.
Taking down the existing distribution boards complete including MCBs and MCCBs all as specified and as directed.
Disconnecting the existing 100 KVA transformer and LT panels from its all electrical connections (HT & LTconnections) and removing the transformer from its foundations, shifting the transformer, HT & LT cables and LT panels safely from localizer substation and hand over to MES stores all as specified and as directed.
United Sales Corporation
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .