Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAccepted-AOC | ₹6.1 Cr | L1 | Accepted-AOC Being reasonable and accepted |
| 2 | L2₹6.4 Cr+₹27.0 L (4.42%)Rejected-AOC 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹6.4 Cr+₹27.0 L (4.42%) | L2 | Rejected-AOC Other Than L1 |
| 3 | L3₹7.1 Cr+₹97.9 L (16.0%)Rejected-AOC BHAPKAR PATIL PLOT NO 24 GURHSHIP HOUSING SOCIETY SATBHAL MALA DEHIGATE AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | ₹7.1 Cr+₹97.9 L (16.0%) | L3 | Rejected-AOC Other Than L1 |
| 4 | L4₹7.1 Cr+₹1.0 Cr (16.7%)Rejected-AOC NOT SPECIFIED | ₹7.1 Cr+₹1.0 Cr (16.7%) | L4 | Rejected-AOC Other Than L1 |
| 5 | L5₹7.4 Cr+₹1.2 Cr (20.2%)Rejected-AOC STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹7.4 Cr+₹1.2 Cr (20.2%) | L5 | Rejected-AOC Other Than L1 |
| Sl No | Description | Qty | Unit | S.T.Biradar Engineers & Contractors Pvt.Ltd. L7 | United Sales Corporation L4 | Horizon Construction L6 | M/s S. R. Constructions L3 | Mehta Construction Co. L2 | KISHORE INFRASTRUCTURES PVT LTD L1 | r.s.jain & sons L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCH 'A PART-I: BUILDING AND STRUCTURES Note: This schedule is pre-priced by MES and the rate indicated as under Col 5 signifies this fact only | ||||||||||
| 2.00 | Total amount of Sch ‘A’ Part I (Building & Structures) | 1 | LUMP SUM | 6,25,00,100 ₹6,25,00,100 | 5,45,00,000 ₹5,45,00,000 | 6,18,32,031.5 ₹6,18,32,031.5 | 5,33,00,000 ₹5,33,00,000 | 4,67,00,000 ₹4,67,00,000 | 4,51,21,925.6 ₹4,51,21,925.6 Lowest | 5,60,00,000 ₹5,60,00,000 |
| 3.00 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork) | 1 | LUMP SUM | 91,00,000 ₹91,00,000 | 15,00,000 ₹15,00,000 | 9,95,213 ₹9,95,213 | 15,00,000 ₹15,00,000 | 10,00,000 ₹10,00,000 | 9,49,014.3 ₹9,49,014.3 Lowest | 10,50,000 ₹10,50,000 |
| 4.00 | Total amount of Sch ‘A’ Part III (Internal Water supply) | 1 | LUMP SUM | 7,25,000 ₹7,25,000 | 50,000 ₹50,000 | 62,450 ₹62,450 | 60,000 ₹60,000 | 55,000 ₹55,000 | 32,292.66 ₹32,292.66 Lowest | 62,750 ₹62,750 |
| 5.00 | Total amount of Sch ‘A’ Part IV (Internal Electric Supply) | 1 | LUMP SUM | 62,00,000 ₹62,00,000 | 30,00,000 ₹30,00,000 | 29,00,000 ₹29,00,000 | 35,00,000 ₹35,00,000 | 28,50,000 ₹28,50,000 | 23,02,108.1 ₹23,02,108.1 Lowest | 30,00,000 ₹30,00,000 |
| 6.00 | Total amount of Sch ‘A’ Part V (Road, Path and Culverts) | 1 | LUMP SUM | 32,00,000 ₹32,00,000 | 17,00,000 ₹17,00,000 | 14,89,544 ₹14,89,544 | 16,00,000 ₹16,00,000 | 19,00,000 ₹19,00,000 | 14,87,768.25 ₹14,87,768.25 Lowest | 16,50,000 ₹16,50,000 |
| 7.00 | Total amount of Sch ‘A’ Part VI (Area Drainage) | 1 | LUMP SUM | 9,00,000 ₹9,00,000 | 3,95,000 ₹3,95,000 | 4,21,000 ₹4,21,000 | 4,30,000 ₹4,30,000 | 3,97,000 ₹3,97,000 | 4,29,540.79 ₹4,29,540.79 | 3,85,000 ₹3,85,000 Lowest |
| 8.00 | Total amount of Sch ‘A’ Part VII (Sewage Disposal) | 1 | LUMP SUM | 9,00,000 ₹9,00,000 | 1,85,000 ₹1,85,000 | 1,56,479 ₹1,56,479 Lowest | 2,00,000 ₹2,00,000 | 1,65,000 ₹1,65,000 | 1,61,722.28 ₹1,61,722.28 | 2,05,000 ₹2,05,000 |
| 9.00 | Total amount of Sch ‘A’ Part VIII (External Water Supply) | 1 | LUMP SUM | 7,00,000 ₹7,00,000 | 35,000 ₹35,000 | 39,050 ₹39,050 | 30,000 ₹30,000 | 45,000 ₹45,000 | 18,174.37 ₹18,174.37 Lowest | 55,000 ₹55,000 |
| 10.00 | Total amount of Sch 'A' Part-IX (External Electric Supply) | 1 | LUMP SUM | 31,00,000 ₹31,00,000 | 15,00,000 ₹15,00,000 | 19,90,000 ₹19,90,000 | 15,00,000 ₹15,00,000 | 20,00,000 ₹20,00,000 | 10,94,256.4 ₹10,94,256.4 Lowest | 18,00,000 ₹18,00,000 |
Tender Value
₹7.5 Cr
EMD Value
₹7 L
Closing Date
28 Nov 2025, 6:00 pmClosed
Chief Engineer Pune Zone
HQ Chief Engineer Pune Zone Camp, Pune 411001
PROVISION OF OTM ACCOMODATION FOR CENTRE UNDER GE (C) KHADKI
2025_MES_736621_1
84604
Open Tender
Civil Works
Lump-sum
365 days
Garrison Engineer (Central) Khadki
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
Garrison Engineer (Central) Khadki
₹7 L
Yes
8 Jan 2026
24 Oct 2025
5 Dec 2025
24 Oct 2025
28 Nov 2025
21 Nov 2025
25 Oct 2025 - 1 Nov 2025
Amount
SCH 'A PART-I: BUILDING AND STRUCTURES Note: This schedule is pre-priced by MES and the rate indicated as under Col 5 signifies this fact only
Total amount of Sch ‘A’ Part I (Building & Structures)
Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork)
Total amount of Sch ‘A’ Part III (Internal Water supply)
Total amount of Sch ‘A’ Part IV (Internal Electric Supply)
Total amount of Sch ‘A’ Part V (Road, Path and Culverts)
Total amount of Sch ‘A’ Part VI (Area Drainage)
Total amount of Sch ‘A’ Part VII (Sewage Disposal)
Total amount of Sch ‘A’ Part VIII (External Water Supply)
Total amount of Sch 'A' Part-IX (External Electric Supply)
Total amount of Sch 'A' Part-X (Rain Water Harvesting)
Total amount of Sch 'A' Part-XI (Lightening Protection)
Total amount of Sch 'A' Part-XII (Wiring for Equipment Load )
Total amount of Sch 'A' Part-XIII (Retaining Wall)
SCHEDULE 'A' PART-XIV (MISC B/R AND E/M WORKS) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only.
M&L Excavation over areas in any kind of soil not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) complete and all as specified and directed.
All as per item No. 15.10 but for depth exceeding 1.5 m but not exceeding 3.0 m by manual means or mechanical means (hydraulic excavator) including lift upto depth of 3.0 m in any kind of soil complete and all as specified and directed.
M&L Excavation in trenches in any kind of soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 Sq.M on plan, including dressing of sides and ramming of bottoms, inlcuding lift upto 1.5 m and getting out the excavated soil, complete all as specified and directed.
M&L Excavation in trenches in any kind of Ordinary rock not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 Sq.M on plan, including dressing of sides and ramming of bottoms, inlcuding lift upto 1.5 m and getting out the excavated rock, complete all as specified and directed.
All as per item No. 15.40 but for depth exceeding 1.5 m but not exceeding 3.0 m by manual means or mechanical means (hydraulic excavator) including lift upto depth of 3.0 m and getting out the excavated rock, complete all as specified and directed.
M&L Excavation in trenches in any kind of Hard rock (without blasting) not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 Sq.M on plan, including dressing of sides and ramming of bottoms, inlcuding lift upto 1.5 m and getting out the excavated hard rock, complete all as specified and directed.
S&F LED bulb 9 W complete all as specified and directed.
S&F Street light bracket made out of 25 mm dia GI tubing, medium grade ISI marked including MS clamp duly painted with two coats of synthetic paint over a coat of red oxide primer, tightening nuts, bolts, washers and taking out existing unserviceable rusted GI bracket complete all as specified and directed.
S&F Vertical Distribution Board Iron clad double door with IP-43, 1K-09 protection suitable for MCCB incomer and MCB SPN as outgoing 415Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link confirming to cat pt No. 607790 of legrand or equivalent of make Hager / Merlin Gerin multi-9 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
S&F SPN AFDD, 40A offering protections for overload, short circuit, Residual current characteristics TYPE A, Over Voltage protection above 270 AC plus minus 5% & series parallel arc fault. AFDD must be dual test button for AFDD and earth leakage functions along with single diagnostic LED with blinking patterns for continuous ON, series Arc, Parallel arc and overvoltage protection complete all as specified and directed.
M&L Cable route indicator duly embossed 11KV for HT UG cable of 11000 volts 80 mm dia CI plate marked on HT cable bolted with 40 x 5mm flat iron of hight 0.4mtr embedded in PCC 1:3:6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.
Supply & install, testing and commissioning step down transformer, out door type and conforming to IS 1180:2014, level -2 plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minimum 7.5% to plus7.5% in steps of 2.5 % continuous rating of capacity 250 KVA including bushing on HT end cable box on LT side the transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and compression of the following accessories :- (a) primary HV side suitable for OH Conductor (consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washer. (b) one cable box on secondary (LV) side consisting of 4Nos porcelain busing with GM bushing roads complete with GH nuts and washer with one Nos cable bland suitable for reception of out going LT armoured cables of suitable size. (c) oil conservator tank with filter type, drain valve and oil level gauge. (d) dehydrating breather with first fill of dehydrating Agent. (e) thermometer pocket on tank cover (f) one Nos100mm dia dial type thermometer vapour pressure type having range 0-120 degree centrigrade with temp reading pointer.
Supply and install automatic power factor correction (APFC) panel out door type factory made of capacity 100 KVAR ready to use design confirming to relevant IS rated for short circuit rating of 100 KA front openable and lockable by keys having louver and air vent, gasket and totally verming proof and suitable for 415/440 Volts, 3 phase 50 HZ AC and housed in elegant enclosure fabricated from minimum 3.15mm thick CRCA sheet, anti corrosive coated to achieve power factor from 0.9 t0 0.99 and finally powder coated in texture siemens Gray RAL 7032 & as a directed by Engineer -in- charge comprising of and including following suitable size and length of copper cable from main panel to APFC panel for connections as approved complete all as specified and directed :- (a) 100 A capacity for phase and 63 A neutral aluminium bush bar duly insulated with colour coated heat shrinkable sleeves and mounted on suitable DMC/epoxy insulator. (b) MCCB 160 Amp 25 KA TP TM based O/C and S/C Rel -01 Nos incoming (c) 6A FPMCB 10 KA -03 Nos (d ) 10 Amp TP MCB 10 KA -02 Nos (e) 20 A TP MCB 10 KA -01 Nos (f) 25 Amp TP MCB 10 KA -03 Nos (g) power contactor 9.7 KVAR TP cap duty, 230 Volt AC - 03 Nos (h) power contractor 12.5 KVAR TP cap duly 230 VAC -03 Nos. (j) Auxillary contact- 4 NC-01 Nos 230 VAC. (k) Add on Auxillary contact- 4NC-01 Nos
Note: (i) Panel should be CPRI approved as per authorised manufacturer workshop and panel drawing to get approval from GE before placing of order (ii) Quoted rate shall be deemed to include suitable PCC work, excavation and removal of soil for fixing of APFC panel any type.
M&L ACSR conductor jumper including alkathin pipe 20mm dia for sleeve purpose and fixing material like as lugs, nut bolt & washer etc. all as specified and directed. Note :- jumper length of minimum 0.6 mtr and maximum 1.5 Mtr.
S&F LED street light fitting 36 watt Each with cast aluminium housing, toughened glass, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and wired with accessories complete all as specified and directed.
S&F Sheet moulding compound junction Each (SMC) suitable for terminating 2 Nos 2 x 6 Sqmm UG cable including cable glandes- 2 Nos, and two way connector 1 No, size 6" x6" including MCB SP 10 Amps10 KA complete all as specified and directed.
S&F GI pipe bracket with suitable clamps on existing pole made of MS flat 40x5mm and 40mm GI pipe (light grade) bend to 1.5 mtr in length& in any shape with all fixing arrangement, nuts, bolts and washers etc and including 2.5M copper conductor cable multistranded of 2.5Sqmm PVC cable from overhead line to fitting connecting box etc complete and all as directed by Engr-in-Charge and including dismantling the rusted/ broken U/S old one.
M&L Platform for installation of transformer size 2m x 2m x 1.50m by brick work with subclass B brick construction in cement motor 1:6, hardcore of gauge not exc. 63mm, filling Moorum/Red bajri in foundation, PCC 1:2:4 type B2 as in floor and 15mm thick on fair faces of brick work or concrete surfaces and Earth work in getting any type of soil including two coated of antifungal paint (apex) over plaster surface complete all as specified and directed.
M&L Chain link fencing of Each Job size 09 x 11 x 2.15 Mtr rolled mild steel work of angle iron fixed independently for fencing post and others confirming to Grade Fe 410-A including cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts including TMT steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete for support of chain link fencing all as specified and as directed.
Note (i) Panel should be CPRI approved as per authorised manufacturer workshop and panel drawing to get approval from GE before placing of order (ii) Quoted rate shall be deemed to include suitable PCC work, excavation and removal of soil for fixing of LT panel any type.
Supply, install, testing and commissioning of Silent Diesel Engine Generating Set, 250 KVA/225 KW (3-Ph), water cooled, powered with Engine developing minimum 126.5 BHP at 1500 RPM, coupled with 415 V, 50 Hz, 3 phase, 0.8 p.f. suitable alternator, 12V Battery with ARAI approved acoustic enclosure & compliance to CPCB-IV norms along with MCCB based AMF logic control panel & SMPS battery charger, tools and spares complete all as specified and directed and comprising of the following:- (a) Engine: Diesel engine, 4 cylinder engine developing required minimum 126.5 BHP 1500 RPM for prime rating of suitable for 250 KVA alternator confirming to BS 5514/180 3046 and revised editions as applicable standard Totally enclosed, electric star, compression ignition, 4 stroke. The engine shall consists of following specifications:- 1.Mechanical FIP 2.Mechanical governor 3.Turbocharger, exhaust manifold, stainless steel exhaust flexible connection 4.Radiator cooled with after cooled 5.Plate type lube oil cooler Filter-fuel, lube oil 6.Dry type replaceable paper element air cleaner 7.Flywheel housing and flywheel to suit single bearing alternator 8.Starting motor- Electric, battery charging alternator 9.First fill lube oil and coolant (b) Alternator: Alternator rated 250KVA, 0.8 PF, 415 V, 3 Phase 4 Wire 4 pole, 50HZ with standard design band of voltage regulation +/-1% from no load to full load and comprising of following specifications:- 1.Brushless alternator
2.Self-excited, self regulated 3.Class 'H' insulation 4.Sallent pole revolving field 5.Single bearing sealed type 6.Automatic voltage regulator (c) Acoustic enclosure: Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound emission standards as laid down by MOEF/CPCB. Base rail with draw-out type fuel tank with capacity 250 Ltr is provided with a drain plug air vent inlet and outlet connections, level indicator, manhole etc. Sub-base fuel tank with 13 hours capacity at 75% load. 12 V 180 AH dry, batteries with connecting leads and terminals complete. (d) Control panel: Powder coated control panel manufactured with CRCA sheet provides: 1.MCCB of suitable rating with overload and short circuit protection 2.Controller which displays voltage, current, KW, PF, Frequency, KWh. 3.Indicating lamps for "Load On" and "Set Running" 4.Current transformers of suitable ratings 5.Copper cable of suitable capacity with incoming and 6.Outgoing terminations 7.Control fuses duly wired and ferruled. (e) Power cables: Uninyvin copper conductor cables between Alternator & Control panel inside the canopy (f) Electrical Systems: Alternator Space Heater/Higher Rating Battery: Battery Charger/Copper Bus Bar/Sealable kWh/Earth Fault Relay/Remote Annunciator/Remote monitoring/Type RTD/BTD Temperature Scanner
g) Exhaust Silencer - Hospital/Residential grade, stainless steel, flexible pipe. Fuel System: Flexible Fuel Lines/SS fuel lines/Fuel Pressure Gauge Enclosed Unit Sound Enclosure - Super silent/External 990 Lt Fuel Tank. Miscellaneous: Air Cleaner (Heavy Duty)/Air Cleaner Restriction Indicator Digital/Closed crankcase ventilation. (h) AMF & Synchronizing System: AMF panel/AMF with Auto-synchronization with all necessary control units, MCCBs/contactors, MCBs etc complete set ready to operate including necessary cable connections. (j) Generator control: The generator control consists of 1.Display parameters: Engine oil pressure, coolant temperature, fuel level indication%, battery voltage, Engine RPM, DG set running hours, Generator volts Ph to N, Ph to Ph, Current, PF, KWHR, KW 2.Audio visual warning: Low Oil pressure, High coolant temperature, Low battery voltage, Low fuel level 3.Shut down with audio visual annunciation: Low Oil pressure. High coolant temp, Engine over speed, engine under speed, low fuel, under voltage, overvoltage, over and under frequency4. Other features Compact and microprocessor based fully configurable control unit with all necessary wirings, MCBs etc, graphic display Note: Quoted rate shall be deemed to include any other technical requirement items & PCC foundation, excavation, removal of soil if any shall be included and quoted in this item only.
Supply, install, testing and commissioning of Silent Diesel Engine Generating Set, 40 KVA/36 KW (3-Ph). water cooled, powered with Engine developing minimum 56 BHP at 1500 RPM, coupled with 415 V, 50 Hz, 3 phase, 0.8 p.f. suitable alternator, 12V Battery with ARAI approved acoustic enclosure & compliance to CPCB-IV+ norms along with MCCB based AMF logic control panel & SMPS battery charger, tools and spares complete all as specified and directed and comprising of the following: (a) Engine: Diesel engine 4 cylinder engine developing required minimum 56 BHP @ 1500 RPM for prime rating of suitable for 40 KVA alternator confirming to BS 5514/ISO 3046 and revised editions as applicable standard Totally enclosed, electric start, compression ignition, 4 stroke. The engine shall consists of following specifications 1.Mechanical FIP 2.Mechanical governor 3.Turbocharger, exhaust manifold, stainless steel exhaust flexible connection 4.Radiator cooled with after cooled 5.Plate type lube oil cooler 6.Filter-fuel, lube oil 7.Dry type replaceable paper element air cleaner 8.Flywheel housing and flywheel to suit single bearing alternator 9.Starting motor- Electric, battery charging alternator 10.First fill lube oil and coolant. (b) Alternator: Alternator rated 260KVA, 0.8 PF, 415 V, 2 Phase 4 Wire 4 pole, 50HZ with standard design band of voltage regulation from no load to full load and comprising of following specifications:-
1.Brushless alternator 2.Self-excited, self regulated 3.Class F Insulation 4.Salient pole revolving field 5.Single bearing sealed type 6.Automatic voltage regulator (c) Acoustic enclosure: Engine alternator assembly mounted on AVM with Silencer and SS Bellows suitably optimized to meet stringent sound emission standards as laid down by MOEF/CPCB. Base frame with draw-out type fuel tank with capacity 200 Ltr is provided with a drain plug, air Vent, inlet and outlet connections, level indicator, manhole etc. Sub-base fuel tank with 13 hours capacity at 75% load 12V 180 AH dry, batteries with connecting leads and terminals complete. (d) Control panel: Powder coated control panel manufactured with CRCA sheet provided 1.MCCB of suitable rating with overload and short circuit protection 2.Controller which displays voltage, current, KW, PF, Frequency, KWH Indicating lamps for "Load On" and "Set Running" 3.Current transformers of suitable ratings 4.Copper cable of suitable capacity with incoming and 5.Outgoing terminations 6.Control fuses duly wired and ferruled. (e) Power cables: Unarmour copper conductor cables between Alternator & Control panel inside the canopy (f) Electrical Systems: Alternator Space Heater / Higher Rating Battery / Battery Charger / Copper Bus Bar / Sealable KWh / Earth Fault Relay / Remote Annunciator/Remote monitoring / Type RTD / BTD Temperature Scanner
(g) Exhaust Silencer - Hospital / Residential grade, stainless steel, flexible pipe. Fuel System: Flexible Fuel Lines / SS fuel lines / Fuel Pressure Gauge. Enclosure Unit: Sound Enclosure - Super silent / External 800 Lt Fuel Tank. Miscellaneous: Air Cleaner (Heavy Duty) Air Cleaner Restriction Indicator Digital / Closed crankcase Ventilation. (h) AMF & Synchronizing System: AMF panel / AMF with Auto-synchronization with all necessary control units, MCCBs/ contactors, MCBs etc complete set ready to operate including necessary cable connections. (i) Generator control: The generator control consists of the 1.Display parameters: Engine oil pressure, coolant temperature, fuel level indicator, battery voltage, Engine RPM, DG set running hours, Generator volts Ph-N, Ph-Ph, Current, PF, KWHR, KVA 2.Audio visual warning: Low Oil pressure, High coolant temperature, Low battery voltage, Low fuel level 3.Shut down with audio visual annunciation: Low Oil pressure, High coolant temp, Engine over speed, engine under speed, low fuel, under voltage, overvoltage, over and under frequency. Other features: Compact and microprocessor based fully configurable control unit with all necessary wirings, MCBs etc, graphic display. Note: Quoted rate shall be deemed to include any other technical requirement items & PCC foundation excavation, removal of soil if any shall be included and quoted in this item only.
S&F Water cooler electric driven (single phase), having approximately storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour. (1X 02Nos for TB2 and 1 x 01Nos for CIW) Complete all as specified and directed.
M&L for laying double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & 14930 (Part-1 and II) Type 450N, for protection of underground cable of size 40mm outer dia with all fittings such as clamps, coupler, bend etc. laid in trenches/roads/nallah or fixed along wall/ poles or laid under floor (including cutting floor/road and making to match with existing adjouning surface etc. for cable protection all as specified. Note : Excavatoin and earth work shall be measured and paid separately.
All as per Item No. 17.70 here-in-before but of size 63mm Outer Dia, complete all as specified and directed.
All as per Item No. 17.70 here-in-before but of size 120mm Outer Dia, complete all as specified and directed.
All as per Item No. 17.70 here-in-before but of size 160mm Outer Dia, complete all as specified and directed.
Mehta Construction Co. (BID ID -3485080)
M/s S. R. Constructions (BID ID -3484904)
United Sales Corporation (BID ID -3484279)
r.s.jain & sons (BID ID -3484693)
Horizon Construction (BID ID -3484707)
S.T.Biradar Engineers & Contractors Pvt.Ltd. (BID ID -3484042)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.72 MB
TD1.rar
Additional Documents • 20.03 MB
TD2.rar
Additional Documents • 19.07 MB
MainDrg.rar
Additional Documents • 21.67 MB
84604-TENDER-UPLOAD.pdf
Tender Documents • 4.65 MB
BOQ_824791.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .